  939   Wed Sep 10 13:28:25 2008 YoichiSummaryElectronicsIOO rack lost -24V (recovered)Alberto, Yoichi

This morning, the MC suddenly started to
  
  938   Wed Sep 10 08:57:03 2008 steveUpdateGeneraletmy illuminator turned offThe ETMY illuminator was left on yesterday.
I just turned it off.
  
  937   Mon Sep 8 15:38:57 2008 YoichiConfigurationPSLPOY RF amp is back to its original taskI temporarily fixed the busted ZHL-32A RF
amplifier's power connector by simply soldering
a cable to the internal circuit and pulling
  
  936   Mon Sep 8 13:47:35 2008 steveUpdatePEMthermostate setting changed[quote][quote]Some one changed the thermostat
(old control room ) setting behind 1Y6 from
73 to 79F
  
  935   Mon Sep 8 10:57:49 2008 steveUpdateIOOthe psl and mc are back to normalThe alarm handler is silent this morning.
This is almost unbelievably pleasant after
two mount of harassment.
 fss.pngpmcbrick.pngbrick.jpg 
  934   Fri Sep 5 15:09:50 2008 ranaUpdatePEMthermostate setting changed[quote]Some one changed the thermostat (old
control room ) setting behind 1Y6 from 73
to 79F
  
  933   Fri Sep 5 10:36:34 2008 steveUpdatePEMthermostate setting changedSome one changed the thermostat (old control
room ) setting behind 1Y6 from 73 to 79F
It should be in the elog.
  
  932   Fri Sep 5 09:56:14 2008 josephb, EricConfigurationComputersFunny channels, reboots, and ethernet connections1) Apparently the I00-ICS type channels had
gotten into a funny state last night, where
they were showing just noise, exactly when
  
  931   Fri Sep 5 08:34:03 2008 steveUpdatePSLMZ lockedThe MC is happy.
The MZ can be locked if you move the slider
by hand.
 mzhv.jpg 
  930   Thu Sep 4 18:02:34 2008 rana, josephbConfigurationPEMAccelerometer gains increased by 10[COLOR=chocolate][SIZE=3]We increased the
Accelerometer gains by 10 by modifying the
C1ADCU_PEM.ini file.[/SIZE][/COLOR]
 acc.png 
  929   Thu Sep 4 17:44:27 2008 YoichiUpdatePSLFSS error signal spectrumAttached is a spectrum of the FSS error signal.
There are a lot of sharp peaks above 100kHz
(the UGF of the servo is about 200kHz).
 FSS-Error-Spe.png 
  928   Thu Sep 4 17:17:03 2008 YoichiUpdateIOOMC open loop TFI measured open loop transfer functions of
the MC servo.
The UGF was about 30kHz. Since there was
 MC-OPLTF.png 
  927   Thu Sep 4 17:12:57 2008 YoichiUpdatePSLFSS open loop TFI changed the gain settings of the FSS servo.
Now the Common Gain is 5dB (the last night
it was 2dB) and the Fast Gain is 12dB (formerly
 FSS-OPLTFs.png 
  926   Thu Sep 4 17:03:25 2008 YoichiUpdatePSLRF oscillator noise comparisonI measured current spectra of the RF signal
going to the FSS EOM.
The attachment compares the spectra between
 RFSpectra.png 
  925   Thu Sep 4 16:24:56 2008 ranaConfigurationComputersAttempt to increase gain for C1:PSL-ISS_INMONPD_F via 110B[quote]We were attempting to increase the
gain on the channel C1:PSL-ISS_INMONPD_F
in preparation to do a scan of the PMC at
  
  924   Thu Sep 4 14:43:58 2008 JenneUpdatePSLPMC Open Loop GainI have measured the PMC's open loop gain.
 [SIZE=3][COLOR=green]UGF is 629.7Hz, with
a phase margin of 53 degrees.
 OpenLoopTF04Sept2008.png 
  923   Thu Sep 4 13:48:50 2008 YoichiUpdatePSLFSS modulation depthI scanned the reference cavity with the NPRO
temperature (see the attached plot).
The power ratio between the carrier and the
 RCScan.png 
  922   Thu Sep 4 11:33:25 2008 josephb, Eric, JenneConfigurationComputersAttempt to increase gain for C1:PSL-ISS_INMONPD_F via 110BWe were attempting to increase the gain on
the channel C1:PSL-ISS_INMONPD_F in preparation
to do a scan of the PMC at very low input
  
  921   Thu Sep 4 10:13:48 2008 JenneUpdateIOOWe unlocked the MC temporarily[Joe, Eric, Jenne]

While trying to diagnose some DAQ/PD problems
  
  920   Thu Sep 4 07:46:10 2008 YoichiUpdateIOOMC is now happyThe MC has been locked for more than 12 hours
continuously now !
Changes I made yesterday were:
 MC-lock.png 
  919   Thu Sep 4 07:29:52 2008 YoichiUpdatePSLc1iovme power cycled[quote]Entry 663 has a plot of this using
the PSL/FSS/SLOWscan script. It shows that
the SB's were ~8x smaller than the carrier.
  
  918   Thu Sep 4 00:38:14 2008 ranaUpdatePSLc1iovme power cycledEntry 663 has a plot of this using the PSL/FSS/SLOWscan
script. It shows that the SB's were ~8x smaller
than the carrier.
  
  917   Wed Sep 3 19:09:56 2008 YoichiDAQComputersc1iovme power cycledWhen I tried to measure the sideband power
of the FSS using the scan of the reference
cavity, I noticed that the RC trans. PD signal
  
  916   Wed Sep 3 18:45:01 2008 AlbertoConfiguration PD3 gainAlberto, Yoichi,

We found that the PD3 servo was unstable
  
  915   Wed Sep 3 18:43:19 2008 YoichiConfigurationElectronicsTwo more active probesI found two active probes, an HP41800A and
a Tektronix P6201.
Thanks John for telling me you saw them before.
 Tektronix-P6201-active-probe.pdf 
  914   Wed Sep 3 12:26:49 2008 EricSummaryCamerasWeekly SummaryFinished up simulating the end mirror error
in order to test the whether the fitting
code still provides reasonable answers despite
 SimulatedErrorComparison.png 
  913   Tue Sep 2 22:43:16 2008 YoichiConfigurationPSLUpdated FSS open loop TFSince the LO level of the FSS servo was too
low, I replaced the RF oscillator board with
a combination of
 OPLTF.png 
  912   Tue Sep 2 14:28:41 2008 YoichiUpdatePSLFSS EOM driving signal spectraRich advised me to change the +10V input of
the FSS crystal frequency reference board
from whatever voltage supply we use now to
 RFDrive1.pngRFDrive2.png 
  911   Tue Sep 2 10:09:03 2008 steveUpdatePSLhead temp is cooling downThe chiller was over flowing this morning.
800 cc of water was removed.
PSL-126MOPA_HTEMP peaked at 20.7 C (normal
  
  910   Tue Sep 2 09:58:42 2008 YoichiConfigurationPSLFSS on an auxiliary loop[quote]Summary: The FSS is now temporarily
disabled. Naturally, the MC won't lock. I
will fix it tomorrow morning.
  
  909   Tue Sep 2 07:58:34 2008 ranaSummaryPSLFSS & PMC LO trends for 2 yearsThe attached plot is a 2 year minute trend
of the EPICS readback of the PMC & FSS LO
Monitors (FSS_LODET & PMC_LODET).
 psl-lo-trend.png 
  908   Mon Sep 1 19:23:17 2008 YoichiConfigurationPSLFSS on an auxiliary loopSummary: The FSS is now temporarily disabled.
Naturally, the MC won't lock. I will fix
it tomorrow morning.
  
  907   Mon Sep 1 04:34:00 2008 ranaUpdatePSLFSS loop transfer functionsI started from 6th item in Yoichi's todo list.

1) Increased the setpoint of the thermostat
 n.pdfFSSLO.PNGFSSLO-Spec.pngPC25.pngpc.pdf 
  906   Sat Aug 30 13:28:01 2008 ranaConfigurationPSLPMC: List of changesThis is a list of changes made to the PMC
board while we had it out for modifying the
notch:
  
  905   Fri Aug 29 22:57:48 2008 YoichiUpdatePSLFSS loop transfer functionsI've been measuring a bunch of transfer functions
of the FSS related stuffs.
There are a lot to be analyzed yet, but here
 OPLTFs.pdfOPLTFsScaled.pdf 
  904   Fri Aug 29 18:24:48 2008 ranaHowToPSLPMC: PZT CalibrationI calibrated the PMC PZT at DC by using 'trianglewave'
to drive the DC offset slider
and reading back PMC_PZT and PMC_TRANSPD_F
 pmc-pzt-cal.pdfmcf.png 
  903   Fri Aug 29 17:39:25 2008 ranaConfigurationPSLPMC: ADC ChannelsThe attached PNG shows the PMC error and controls
signals with no calibration.
 mcf.png 
  902   Fri Aug 29 16:35:18 2008 YoichiConfigurationPSLbeam block distorted[quote]There was a beam block after the Mach
Zender. Who or what put this there?
  
  901   Fri Aug 29 15:01:45 2008 steveUpdatePSLMOPA_HTEMP in increasingThe laser chiller temp is 21.9C ( it should
be 20.0C )
Control room temp 73F ok, no obvious block
 htcl.jpg 
  900   Fri Aug 29 12:43:44 2008 josephbSummaryComputersc1susvme1 downAround noon today, c1susvme was having problems.
 The C0DAQ_RFMNETWORK light was red.  The
status light was off, the sig det light was
  
  899   Fri Aug 29 12:41:26 2008 josephb, EricConfigurationComputersMore front ends moved to new networkUsed Cat6 cables to finish moving all the
front ends in 1Y4 and 1Y5 over to the new
GigE network switches, specifically to the
  
  898   Fri Aug 29 11:05:11 2008 josephbSummaryComputersc1asc was down this morningI had to manually reboot c1asc this morning,
as for some unknown reason its status was
red, and the fiber lights on the board were
  
  897   Fri Aug 29 11:01:49 2008 josephbConfigurationComputersAttempt to change a channel gain in ICS-110BAs noted earlier by Rana, I was playing around
with the /cvs/cds/caltech/chans/daq/C1IOOF.ini
file with help from Rob.  I had made a backup
  
  896   Fri Aug 29 10:20:32 2008 YoichiConfigurationPSLbeam block distorted[quote]There was a beam block after the Mach
Zender. Who or what put this there?
  
  895   Fri Aug 29 02:40:43 2008 rana,jenneUpdatePSLPMC Servo Board[quote]Board is back in. PMC is locked.
[/quote]
 pmclp-07.pdfpmclp_40m_080824.mpmclp.m 
  894   Thu Aug 28 19:02:25 2008 rana, josephb, robSummaryComputersbig bootThis afternoon Joe did something with an .ini
file (look for his detailed elog entry) and
the computers went bad.
  
  893   Thu Aug 28 18:56:14 2008 ranaConfigurationPSLbeam block distortedThere was a beam block after the Mach Zender.
Who or what put this there?
  
  892   Wed Aug 27 13:55:43 2008 rana,jenneUpdatePSLPMC Servo BoardBoard is back in. PMC is locked.

Nominal gain is now 15 dB with brick. We
  
  891   Wed Aug 27 12:09:10 2008 EricSummaryCamerasWeekly SummaryI added a configuration file parser to the
Snap code.  This allows all command line
parameters (like exposure time, etc.) to
 originalETMX.pngrotatedETMX.png 
  890   Wed Aug 27 10:55:35 2008 YoichiHowToComputersAnnoying behavior of the touch pads of the lab. laptops is fixedI was sick of the stupid touch pad behavior
of the lab. laptops, i.e. firefox goes back
and forth in the history when the cursor
  