40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 338 of 341  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Date Authorup Type Category Subject Text Attachments
  8028   Thu Feb 7 19:25:22 2013 yutaUpdateCDSC1ALS filters reloadedFilters for C1ALS were all gone. So, I
copied /opt/rtcds/caltech/c1/chans/C1GCV.txt
and renamed it as 
  
  8034   Fri Feb 8 12:39:32 2013 yutaUpdateLockingPRMI workHalf-PRC at this time already have two
changes from the previous half-PRC; PR2 replaced/flipped
and different TM before BS.
  
  8036   Fri Feb 8 12:43:26 2013 yutaUpdateComputersvideocapture.py now supports movie capturingI updated /opt/rtcds/caltech/c1/scripts/general/videoscripts.py
so that it supports 
  
  8041   Fri Feb 8 19:29:44 2013 yutaSummaryGeneralarbcav of half PRC with flipped PR2We need expected finesse and g-factor to
compare with mode-scan measurement. Can you
give us the g-factor of the half-PRC and
  
  8049   Fri Feb 8 23:59:42 2013 yutaUpdateLockingPR2-flipped half-PRC mode scanI did mode scan of PR2-flipped half-PRC
to see if it behaves as we expect.
Measured
 halfPRCmodescan.png 
  8052   Sun Feb 10 17:30:39 2013 yutaUpdateLockingPR2-flipped half-PRC mode scanI redid half-PRC mode scan by applying
mislignment to PRM.
Half-PRC's
 modescan_pitmisalign.pngmodescan_yawmisalign.png 
  8053   Sun Feb 10 18:00:13 2013 yutaSummaryLSCPR2-flipped half-PRC spectra/OLTFTo compare with future PRMI locking, I
measured spectra of POPDC and feedback signal.
I also measured openloop transfer function
 POPDCLSCPRM.pngLSCPRCLOLTF.png 
  8056   Mon Feb 11 13:15:16 2013 yutaUpdateLockingPR2-flipped half-PRC mode scanI found a mistake in my code (thanks Jamie!).
I forgot to square the g-factor.
I corrected the following elogs;
  
  8064   Mon Feb 11 21:03:15 2013 yutaUpdateLockingPR2-flipped half-PRC mode scanTo estimate the systematic effects to the
g-factor measurement, I changed how to analyze
the data in multiple ways.
 modespacing_pit.pngmodespacing_yaw.png 
  8065   Tue Feb 12 00:14:00 2013 yutaUpdateLockingPRM coil balancingWe tried to lock half-PRC tonight, but
we couldn't. Why?? I could lock yesterday.
It locks for ~ 1 sec, but it beam
  
  8066   Tue Feb 12 00:50:08 2013 yutaUpdateLockingPR2 oplev spectraI wanted to see if PR2 motion makes PRC
beam motion or not, using temporary oplev
to PR2.
 PR2oplev.png 
  8073   Tue Feb 12 23:24:17 2013 yutaUpdateAlignmentIFO alignment in prep for in-air PRMI[Manasa, Yuta]

Lot's of alignment work, 
  
  8074   Wed Feb 13 01:26:08 2013 yutaSummaryGeneralrough analysis of aligned PRM-PR2 mode scanKoji was correct.

When you estimate the variance of
 unbiased.png 
  8078   Wed Feb 13 19:09:32 2013 yutaSummaryGeneralpossible explanations to oval REFL beam[Jenne, Manasa, Jamie, Yuta]

The shape of the REFL beam reflected
 REFL_1044844506.bmp 
  8080   Wed Feb 13 19:41:07 2013 yutaSummaryGeneralpossible explanations to oval REFL beamWe checked that REFL beam is already oval
in the vacuum. We also centered in-air optics,
including lens, in the REFL path, but REFL
  
  8082   Thu Feb 14 00:10:12 2013 yutaSummaryAlignmentREFL is not clippedLet's wait for astigmatism calculation.

In either case(clipping or astigmatism),
  
  8091   Fri Feb 15 20:07:28 2013 yutaUpdateAlignmentPOP path set up but AS55 is broken[Manasa, Yuta]

We set up POP camera and POPDC PD,
  
  8092   Fri Feb 15 21:22:29 2013 yutaUpdateElectronicsAS55 replaced with POP55 PDI temporarily replaced AS55 PD with PD
labeled "POP55(POY55)".
I think POP55 is working because I
  
  8093   Sat Feb 16 17:27:26 2013 yutaUpdateSUSPRM coil balancedPRM coil gains and f2a filters are adjusted
for PRMI work.
It seems like 
 PRM_f2a.png 
  8094   Sat Feb 16 18:32:01 2013 yutaSummaryRF Systemphase tracker: OLTFI measured openloop transfer function of
the phase tracking loop for the first characterization
of phase tracker.
 BEATXFINEPHASE_OLTF.pngBEATYFINEPHASE_OLTF.pngphasetracker.png 
  8095   Sat Feb 16 19:23:17 2013 yutaUpdateLSCPR2 flipped PRMI lockedIt is my pleasure to announce that the
first lock of PR2 flipped PRMI was succeeded.
  
  8099   Mon Feb 18 18:28:01 2013 yutaBureaucracyAlignmentwe are going to pump downWe
will start preparing for pumping down. Main
goal for this is to demonstrate PRFPMI using
  
  8102   Tue Feb 19 00:21:09 2013 yutaUpdateElectronicsPOP path set up but AS55 is brokenHmm......  
I thought AS55 is broken because it
was not responding to the AS beam nor flashlight
  
  8103   Tue Feb 19 02:23:40 2013 yutaBureaucracyGeneralaction items for PRFPMIThese are things need to be done for demonstrating
PRFPMI using ALS.
All of these should be done before
  
  8105   Tue Feb 19 08:06:02 2013 yutaUpdateElectronicsPOP path set up but AS55 is brokenI didn't use LED flash light. We learned
from the past (elog
#7355). I checked that POP55 and REFL55/165/33/11
  
  8112   Tue Feb 19 19:55:52 2013 yutaUpdateIOOMC yaw input tuned[Jenne, Manasa, Yuta]

Since we levelled IMC stack, we had
 MCdecenter_19Feb2013.png 
  8114   Wed Feb 20 03:13:10 2013 yutaUpdateAlignmentclipping centering checklistI attached clipping/centering checklist
for the alignment.
Blue
 ClippingCenteringChecklist.pdf 
  8115   Wed Feb 20 10:13:41 2013 yutaUpdateAlignmentPRC flashing brighter than last weekAfter in-vac alignment work last night,
PRC is flashing brighter than PRMI alignment
last week.
  
  8119   Wed Feb 20 19:48:16 2013 yutaUpdateAlignmentBS table oplev re-arranged[Sendhil, Yuta]

After aligning IFO and putting the
 IFOALIGN_QPDs_OSEMs.png 
  8121   Wed Feb 20 20:15:29 2013 yutaUpdateAlignmentSRM oplev statusCurrently, SRM is misaligned in pitch so
that SRM reflected beam hits on the top edge
of SR3 (not on the mirror, but on the cage
  
  8122   Wed Feb 20 20:58:37 2013 yutaUpdateAlignmentclipping centering checklistBlue
ones are the ones we checked yesterday.
Green
 ClippingCenteringChecklist.pdf 
  8124   Wed Feb 20 21:56:08 2013 yutaUpdateAlignmentclipping centering checklistI'm not sure about the OMC situation at
40m. I think there are no direct beam reflected
back into IFO from OMC path. There must be
  
  8129   Thu Feb 21 15:21:07 2013 yutaUpdateVACall heavy doors on, started pumping down annulus[Steve, Manasa, Jenne, Sendhil, Evan,
Yuta]
  
  8141   Sat Feb 23 00:34:28 2013 yutaUpdateComputerscrontab in op340m deleted and restored (maybe)I
accidentally overwrote crontab in op340m
with an empty file.
  
  8143   Sat Feb 23 07:14:58 2013 yutaUpdateLSCcan't lock Y armI tried to align and lock Y arm for the
first time after pumping.
But I couldn't lock Y arm for more
 TRYPOY.png 
  8146   Sat Feb 23 15:26:26 2013 yutaUpdateComputerscrontab in op340m updatedI found some daily cron jobs for op340m
I missed last night. Also, I edited timings
of hourly jobs to maintain consistency with
  
  8150   Sat Feb 23 17:14:59 2013 yutaUpdateLSCcan't lock Y armJenne found that;
  0. If all mirrors are "aligned,"
Yarm flashes.
  
  8157   Mon Feb 25 15:30:29 2013 yutaUpdateAlignmentY arm locked, both colors[Koji, Yuta]

We aligned Y arm to Y green and tweaked
  
  8162   Mon Feb 25 21:25:14 2013 yutaUpdateAlignmentboth arms locked in IR[Jenne, Evan, Yuta]

After Y alignment, X arm is aligned
 QUAD1_1045890588.png 
  8164   Mon Feb 25 22:42:32 2013 yutaSummaryAlignmentcurrent IFO situation[Jenne,Yuta]

Both arms are aligned starting from
 IPANGdrift.png 
  8177   Wed Feb 27 01:09:53 2013 yutaUpdateLockingPRMI sideband/carrier locked[Jenne,Yuta]

We succeeded in locking PRMI in sideband
 6x 
  8181   Wed Feb 27 11:22:54 2013 yutaUpdateComputersbackup crontabI made a simple script to backup crontab
(/opt/rtcds/caltech/c1/scripts/crontab/backupCrontab).
  
  8182   Wed Feb 27 11:59:43 2013 yutaUpdateSUSPRM/BS coil re-balancedI re-adjusted coil gains and f2a filters
for PRM and BS.
I'm not sure what happened to PRM
 PRM_f2a20130227.pngBS_f2a20130227.png 
  8196   Thu Feb 28 02:43:49 2013 yutaUpdateLSCsome qualitative evidence of PRMI sideband lock[Manasa, Yuta]

Since we have setup POP22 PD now(
 PRMIsideband.png 
  8197   Thu Feb 28 03:25:27 2013 yutaUpdateLSCPR gain ~ 25 from PRMI carrier lock[Manasa, Yuta]

We locked PRMI in carrier. 
 PRMIcarrier.png 
  8199   Thu Feb 28 05:54:54 2013 yutaUpdateRF Systemphase tracker: calibrationI swept the frequency of RF input to the
beatbox to calibrate and check linearity
range of phase tracker.
 ALS-BEATX_FINE_PHASE_OUT.pngALS-BEATY_FINE_PHASE_OUT.png 
  8200   Thu Feb 28 06:51:17 2013 yutaUpdateRF Systemphase tracker: noise levelI measured noise level of the phase tracker
by inputting constant frequency RF signal
from marconi.
 frequencynoise.png 
  8208   Fri Mar 1 16:58:37 2013 yutaUpdateLSCXarm oscillation stoppedPOX11 oscillation at 630 Hz was stopped
by installing 630 Hz resonant gain to LSC_XARM.
After few hours, oscillation stopped.
 POX11_630Hz.png 
  8212   Sat Mar 2 05:53:15 2013 yutaUpdateLSCstable lock of PRMII tuned alignment, gains and filters to
achieve stable lock of PRMI.
It now locks quite stably with UGF
 LSCMICHOLTF_PRMI.pngLSCPRCLOLTF_PRMI.pngPRMtoAS55REFL55.png 
  8214   Sat Mar 2 20:09:12 2013 yutaUpdateRF Systemphase tracker: DAQ noise limited[Koji, Yuta]

We found that our phase tracker noise
 frequencynoisewhitening.png 
ELOG V3.1.3-