  142   Thu Nov 29 18:10:13 2007 AlbertoHowToComputer Scripts / ProgramsGPIB ScriptsI've spent a lot of time trying to configurate
the GPIB-USB interface for the HP4195. After
installing 1) the Agilent libraries, 2) the
  
  141   Thu Nov 29 15:17:53 2007 robConfigurationPSLISS
I put some ISS beam on the diode on the PSL
table.  In the previous layout, this was
  
  140   Thu Nov 29 14:29:22 2007 tobinConfigurationComputerslinux1 httpd/conlogger fixedI think I fixed the [url=http://linux1/cgi-bin/conlog_web.pl]conlogger
web interface on linux1[/url].
  
  139   Thu Nov 29 11:10:54 2007 robOmnistructureVACRGAlogger sleepingWithout the RGA controller responding, the
RGAlogger script just hangs.  Rather than
fix it, I just put it to sleep by commenting
  
  138   Thu Nov 29 10:36:47 2007 albertoConfigurationComputer Scripts / ProgramsAgilent 82357B GPIB to USB Interface Installation ProcedeureTo run the Agilent Automation-Ready CD provided
with the interface is only the first step
of the installation. Apparently there should
  
  137   Wed Nov 28 21:51:52 2007 tobinConfigurationPSLISSI replaced the front-end differential receivers
for the ISS's "inner-loop" sensor and monitor
diode inputs with lower-noise [url=http://focus.ti.com/docs/prod/folders/print/ths4131.html]THS4131[/url]'s
  
  136   Wed Nov 28 19:44:18 2007 tobinUpdatePSLHEPAI found the HEPA turned off completely.  I
turned it on.
  
  135   Wed Nov 28 19:02:41 2007 AndreyBureaucracyWIKI-40M UpdateNew WIKI-40M page describing Matlab Suspension Modeling
I created the WIKI-40m page with some details
about my today's talk on the 40-m lab meeting.
  
  134   Wed Nov 28 17:41:34 2007 robUpdatePSLFSS againI investigated the FSS a bit more today. 
I looked at the signals coming out of the
FSS frequency reference, and saw that both
  
  133   Wed Nov 28 17:15:26 2007 ranaConfigurationSUSETMY damping / watchdogsSteve has noted that ETMY was often tripping
its watchdog. I saw this again today.
  
  132   Wed Nov 28 16:46:28 2007 ranaConfigurationComputersscientific linux 5.0I tried installing Scientific Linux on Tiramisu.
The installation process was so bad (really)
that I quit after 15 minutes. Its back to
  
  131   Wed Nov 28 16:18:15 2007 AlbertoMetaphysicsEnvironmentso clean you can eat on itI tidied up the desks in the lab, brought
the Spectrum Analyzers back to the Salumeria
(you don't want to know about that), sorted
 DSC_0180.JPGDSC_0181.JPG 
  130   Wed Nov 28 12:43:53 2007 AndreyBureaucracy Here was the PDF-file of my presentation
I was  making a report with powerpoint presentation
during that Wednesday's 40-m meeting.
  
  129   Wed Nov 28 08:47:29 2007 steveOmnistructureVACrga is out of orderThe rga is not working since Nov 10
The controller is broken.
pd65-m-d23
 pd65d23.jpg 
  128   Wed Nov 28 04:21:46 2007 ranaUpdatePSLFSS[quote]Rana, Tobin
[SIZE=1]
We looked at the RF PD signal to the FSS
  
  127   Tue Nov 27 20:47:00 2007 tobinUpdatePSLFSSRana, Tobin

We looked at the RF PD signal to the FSS
 fss-tf0001.pdf 
  126   Tue Nov 27 16:18:58 2007 robConfigurationIOOMC loopReduced the common gain to 22dB in the [COLOR=blue]mcup[/COLOR]
script, so that the WFS would not blow the
lock.  The above measure of the OLG was done
  
  125   Tue Nov 27 15:47:17 2007 robConfigurationIOOMC loopAfter the FSS running pretty quick, I checked
the MC loop.  I used TPA 1&2.
 MCsmall.jpg 
  124   Tue Nov 27 15:45:08 2007 robConfigurationPSLFSS loop
It's unclear (to me, at least) what was the
end result of the FSS path tweaking before
 FSSsmall.jpg 
  122   Mon Nov 26 10:17:31 2007 steveOmnistructureSUSetmy sus damping restored20 days plot is showing etmy loosing damping
4 times.
I zoomed in with each event. Three of them
 etmyrms20d.jpgetmyrmseq.jpg 
  121   Wed Nov 21 14:31:41 2007 robUpdatePSLFSS twiddle
I `tweaked' the FSS path today.  Here's what
I did:
  
  120   Tue Nov 20 18:35:20 2007 JohnHowToComputersMatLab in EmacsIf you can't get MatLab to run in emacs try
adding the following to the .emacs file
  
  119   Tue Nov 20 18:02:54 2007 JohnSummaryComputersPSL_Main screenI've updated the PSL_MAIN screen. The old
version may be found in cvs/cds/caltech/medm/old/medm/psl.
 PSL_Screen.tif 
  118   Tue Nov 20 13:06:57 2007 tobinConfigurationComputerslinux1 has new diskAlex put the new hard disk into linux1 along
with a fresh install of linux (CentOS). 
The old disk was too damaged to copy.
  
  117   Tue Nov 20 11:10:07 2007 tobinUpdateComputersepics access from matlabI installed "[url=http://www.slac.stanford.edu/~strauman/labca/]labca[/url]",
which allows [b]direct access to EPICS channels
from within Matlab[/b].  It comes with both
  
  116   Tue Nov 20 10:11:33 2007 JohnSummaryPSLPMC pole measurementsWe measured the PMC pole in the following
way.
 FittedPMCPeak.jpg 
  115   Mon Nov 19 14:32:10 2007 steveBureaucracySAFETYgrad student safety trainingJohn Miller and Alberto Stochino has received
the 40m safety bible.
 They still have to read the laser operation
  
  114   Mon Nov 19 14:19:25 2007 steveOmnistructurePEMjackhammerThe construction personal successfully jackhemmered
a fence around the "Drever's parking slot"
There is no parking space available close
 jackhammer.jpgjackhammer2.jpg 
  113   Fri Nov 16 18:46:49 2007 steveBureaucracyPSL MOPA was turned off & onThe "Mohana" boys scouts and their parents
visited the 40m lab today.
The laser was turned off for their safety.
  
  112   Fri Nov 16 14:31:43 2007 tobinUpdateComputersop140 disksPhil Ehrens stopped by and took op140's disks.  DSC_0173.JPG 
  111   Fri Nov 16 14:11:26 2007 tobinUpdateComputersop140Alan called to say that Phil Ehrens will be
coming by to take [b]op140[/b] off our hands.
  
  110   Fri Nov 16 11:27:18 2007 tobinUpdateComputersscript fixI added a tidbit of code to "LIGOio.pm" that
fixes a [url=http://lhocds.ligo-wa.caltech.edu:8000/40m/EZCA]problem
with ezcastep on Linux[/url].  Scripts such
  
  109   Thu Nov 15 18:37:06 2007 tobinUpdateComputerspossible replacement for linux1's diskIt looks like the existing disk in linux1
is a Seagate ST380013A (this can be found
either via the smartctl utility or by looking
  
  108   Thu Nov 15 18:36:48 2007 JohnSummary PSL table workI've rotated the lambda/2 plate to 340deg
(from 6 deg) and blocked one arm of the Mach-Zender.
Undo both if you need to.
  
  107   Thu Nov 15 18:23:55 2007 JohnHowToComputersSwap CAPS and CTRL on a Windows 2000/XP machineI've swapped ctrl and caps on the four control
room Windows machines. Right ctrl is unchanged.
  
  106   Thu Nov 15 18:06:06 2007 tobinUpdateComputersalex: linux1 root file system hard disk's dyingI just noticed that Alex made [url=http://www.ldas-sw.ligo.caltech.edu/ilog/pub/ilog.cgi?group=40m&date_to_view=11/14/2007&anchor_to_scroll_to=2007:11:14:20:00:29-aivanov]an
entry in the old ilog[/url] yesterday, saying:
"[color=red][b]Looks like linux1 root filesystem
  
  105   Thu Nov 15 17:09:37 2007 pkpUpdateOMCVertical Transfer functions with no cables attached.[Norna Pinkesh]

The cables connecting all the electronics
 VerticaltransferfuncnocablesattachedNov152007.pdf 
  104   Thu Nov 15 04:18:11 2007 JohnSummaryPSLPMC cavity pole measurementsIn connection with our work on the ISS I attempted
to measure the PMC cavity pole.
 Peaks.jpg 
  103   Wed Nov 14 17:50:00 2007 tobinUpdatePSLISSHere's the current wiring between the ISS
and its PDs:
  
  102   Wed Nov 14 16:54:54 2007 pkpUpdateOMCMuch better looking vertical transfer functions[Norna Pinkesh]

So after Chub did his wonderful mini-surgery
 VerticalTransPreampwireremovedNov142007.pdfVerticalTranswiresclampedNov142007.pdf 
  101   Wed Nov 14 12:47:19 2007 tobinUpdatePSLISSJohn, Tobin

With John's notch filter installed and the
  
  100   Wed Nov 14 12:33:35 2007 tobinAoGEnvironmentconstructionThe construction crews are running a jack-hammer
right outside of the control room.
 DSC_0172.JPG 
  99   Wed Nov 14 07:48:38 2007 nornaOmnistructureOMCOMC Cable dressing[Snipped from an email]

1) Last Friday Pinkesh and I set the OMC
 OMC-11-13-07_011.jpgVerticalTrans.pdf 
  98   Tue Nov 13 14:33:40 2007 JohnUpdatePSLISS filterThe transfer function from 'In Loop Error
Point Monitor' to TP3 the filter out test
point on the ISS board.
 PB130035.JPGDSC_0165.JPG 
  97   Mon Nov 12 23:44:19 2007 JohnUpdatePSLISS[quote]
After John soldered a 3.7 MHz notch filter
onto the ISS board, I took a quick TF and
 ISSfilter.jpg 
  96   Mon Nov 12 15:18:34 2007 robUpdatePSLISS
After John soldered a 3.7 MHz notch filter
onto the ISS board, I took a quick TF and
 ISS.png 
  95   Mon Nov 12 15:05:49 2007 robConfigurationPSLFSS
Spent a bit of time fiddling with the FSS
again today.  In a not-particularly-systematic
  
  94   Mon Nov 12 14:09:19 2007 robDAQGeneraltpman dead on fb40mThe testpoint manager was dead on fb40m. 
I know I re-started it sometime after the
power outage, so something must have killed
  
  93   Mon Nov 12 10:53:58 2007 pkpUpdateOMCVertical Transfer functions[Norna Sam Pinkesh]

These plots were created by injected white
 VerticalTrans.pdf 
  92   Sun Nov 11 21:21:04 2007 ranaHowToComputersNew DVTo use the new ligoDV (previously GEO DV)
to look at 40m data, open up a matlab, set
up for mDV as usual,
 Screenshot-1.png 
ELOG V3.1.3-