    Reply  Thu Jul 22 07:19:56 2010, Alberto, Update, Treasure, Monsters, LNVR, and Phase noise 


    
        
            Quote:
        
        
            
            On Picasa
    Reply  Thu Jul 22 15:59:29 2010, Alberto, Update, PSL, PSL front end machine 


    
        
            Quote:
        
        
            
            It looks like something wrong happened around the PSL front end.  One
    Reply  Thu Jul 22 18:18:54 2010, Alberto, Update, PSL, Problem Solved 


    
        
            Quote:
        
        
            
            
            
  
Entry  Sat Jul 24 14:03:19 2010, Alberto, Update, Electronics, FSS Oscilaltor Phase Noise Measurement FSScrystalPhaseNoiseHigherGain.pdf
[Rana, Alberto]
Today we measured the phase noise of the oscillator used for the FSS.
The source is a Wenzel crystal at about 21.5MHz that Peter Kalmus built some time ago.
Entry  Sun Jul 25 18:47:23 2010, Alberto, Update, SVN, Optickle 40mUpgrade model updated to include short cavity length corrections 
I uploaded an updated optickle model of the upgrade to the SVN directory with the optickle models (here).
Entry  Thu Jul 29 22:08:32 2010, Alberto, Update, SUS, More optics installed on the BS table 
[Koji, Steve, Kiwamu, Alberto]
- This afternoon we installed a few new optics on the BS table: GR_PBS, GRY_SM2, GRY_SM1.
- We pulled up the cables so that we had more freedom to move one of the cable towers farther South.
Entry  Tue Aug 17 09:06:08 2010, Alberto, Update, elog, elog was down 
I just restarted the elog after I found it down a few minutes ago.
Entry  Fri Aug 20 16:41:43 2010, Alberto, Update, Electronics, Frequency Generation Box Assembly Completed 7x
I finished assembling the frequency generation unit for the upgrade. I tested it through to check that the power levels are as expected at the various
connection (see attached png, showing in black the design power values, and in red the measured ones).
Because of some modifications made on the design along the construction, I have to recalculate the SNR along the lines.
Entry  Tue Aug 31 17:58:38 2010, Alberto, Update, Electronics, FSS Frequency Generation Box - Phase Noise 2010-08-31_FSSPhaseNoise04modified.png
A few weeks ago, on Jul 24, Rana and I measured the phase noise of the FSS frequency box (aka the 'Kalmus Box'). See elog entry 3286.
That time, for some reason, we measured a phase noise higher than we expected; higher than that of the Marconi.
I repeated the measurement today using the SR785 spectrum analyzer. Here is the result:
Entry  Wed Sep 1 07:52:27 2010, Alberto, Configuration, Electronics, PMC board unplugged, turned on Sorensen switches on 1Y1 rack 
Today I put the FSS frequency box back into the 1Y1 rack.
To power it on, I turned on the 24V and 15V Sorensen switches in the same rack.
The PMC crystal board in the same rack should not be affected (it runs with 10V), but, to make sure it was not powered, I disconnected it from
    Reply  Wed Sep 1 08:40:28 2010, Alberto, Configuration, Electronics, PMC board unplugged, turned on Sorensen switches on 1Y1 rack 


    
        
            Quote:
        
        
            
            Today I put the FSS frequency box back into the 1Y1 rack.
Entry  Wed Sep 1 11:34:39 2010, Alberto, Update, Electronics, FSS Box Phase Noise from DAQ 2010-09-01_FSSPhaseNoise.png2010-09-01_FSSphaseNoiseMeasurementSetup.png
I measured the phase noise of the LO output of the FSS box from the DAQ. I'm attaching the results.
As we expected, the measurement is limited by the internal phase noise of the Marconi.
    Reply  Wed Sep 1 16:29:28 2010, Alberto, Update, Electronics, FSS Box Phase Noise from DAQ - Measurement setup modified 2010-09-01_FSSPhaseNoise_DAQ_00-02_comparison.png2010-09-01_FSSPhaseNoise_DAQ_02.pngFSSphaseNoiseMeasurementSetup02.png


    
        
            Quote:
        
        
            
            The differences between this setup and the one used previously is the lack of the 50 Ohm terminator in the mixer output
Entry  Fri Sep 3 11:03:41 2010, Alberto, Frogs, Electronics, Cable cutting tools 
I found this very interesting German maker of cool cable cutting tools. It's called Jokari.
We should keep it as a reference for the future if we want to buy something like that, ie RF coax cable cutting knives.
http://www.jokari.de/en.htm
Entry  Mon Sep 6 10:08:10 2010, Alberto, Configuration, Computers, Netgear Network Switch fan broken. 
The Netgear Network Switch in the top shelf of Nodus' rack has a broken fan. It is the one interfaced to the Martian network.
The fan must have broken and it is has now started to produce a loud noise. It's like a truck was parked in the room with the engine running.
Also the other network switch, just below the Netgear, has one of its two fans broken. It is the one interfaced with the General Computer Side.
Entry  Mon Sep 6 22:09:11 2010, Alberto, Update, Electronics, RF Frequency Generation Box heat sink installed and tested DSC_2467.JPG2010-09-06_FreqBoxAmplifierTemperatureTrend.pngDSC_2433.JPG
Last week I noticed that the high power amplifiers in the Frequency Generation Box became hot after 2 hours of continuous operation with the lid of the
box closed. When I measured their temperature it was 57C, and it was still slowly increasing (~< 1K/hr).
According to the data sheet, their maximum recommended temperature is 65C. Above that their performances are not guaranteed anymore.
Entry  Tue Sep 7 08:56:00 2010, Alberto, Update, Electronics, Frequency Generation Box Assembly - Phase Noise Measurements 2010-09-03_FreqBoxPhaseNoise_AllOutputsComparison_smooth.png2010-09-03_FreqBoxPhaseNoise_AllOutputsComparison_smooth.pdf
Here are the results of my phase noise measurements on the 7 outputs of the Frequency Generation Box. (BIN=95L applied by DTT). See attached pdf for
a higher definition picture.
Entry  Tue Sep 7 13:31:49 2010, Alberto, Update, Electronics, RF System - Frequency Distribution Box - Priority Plan Visio-RFsystem_plan_distributiont.pngRFsystem_plant_distribution_priority.png
We need a distribution unit in the LSC rack to: 1) collect the demod signals coming from the Frequency Generation Box 2) adjust the power level 3) generate
2nd harmonics (for POP) 4) distribute the demod signals to the single demodulation boards.
The base line plan is the following:
Entry  Tue Sep 7 15:57:07 2010, Alberto, Configuration, Computers, Nodus connection not working. Fixed 
[Joe, Alberto]
The Nodus connection to the Martian network stopped working after someone switched cables on the Netgear router. Apparently that router doesn't
like to have the 23 and 24 ports connected at the same time.
Entry  Tue Sep 7 22:21:17 2010, Alberto, Configuration, Computers, elog restarted 
 
Entry  Thu Sep 9 12:02:03 2010, Alberto, Update, Electronics, Frequency Generation Box - Amplitude Noise Measurements FreqBoxAmplitudeNoiseMeasurementSetup.pngFreqBoxAmplitudeNoise_BusbyBox_AllChannels.png
I measured the amplitude noise of the source outputs and the EOM outputs of the Frequency Generation box.
the setup I used is shown in this diagram:
Entry  Thu Sep 9 18:53:56 2010, Alberto, Configuration, Electronics, Busby Box, Rai's Box, SR554 in the RF cabinet 
I stored the Busby Box, the Rai's Box and the SR554 preamp in the RF cabinet down the Y arm.
Entry  Mon Sep 13 11:40:50 2010, Alberto, Update, Electronics, Frequency Box Documentation Added to the SVN freqBoxSVNdierctoryStructure.png
I uploaded all the material about the RF frequency Generation Box  into the SVN under the path:
https://nodus.ligo.caltech.edu:30889/svn/trunk/docs/upgrade08/RFsystem/frequencyGenerationBox/
I structured the directory as shown in this tree:
    Reply  Tue Sep 14 18:07:41 2010, Alberto, Update, Electronics, Frequency Box Documentation Added to the SVN 
I completed a LIGO document describing design, construction and characterization of the RF System for the 40m upgrade.
It is available on the SVN under https://nodus.ligo.caltech.edu:30889/svn/trunk/docs/upgrade08/RFsystem/RFsystemDocument/
It can also be found on the 40m wiki (http://lhocds.ligo-wa.caltech.edu:8000/40m/Upgrade_09/RF_System#preview), and DCC under the number T1000461.
    Reply  Fri Oct 22 18:22:27 2010, Alberto, Update, Electronics, Epic Takeover 


    
        
            Quote:
        
        
            
            As the suspension work winds down (we'll be completely done once the ETMs arrive, are suspended, and then are placed
    Reply  Tue Oct 26 07:02:05 2010, Alberto, Configuration, elog, ELOG 2.8.0 -> ELOG 2.7.5 


    
        
            Quote:
        
        
            
            ELOG reverted to 2.7.5 due to editing difficulties
    Reply  Thu Nov 11 07:26:03 2010, Alberto, Update, Electronics, REFL11 Photodiode Not Working 


    
        
            Quote:
        
        
            
            [Koji and Kevin]
Entry  Mon Mar 25 18:58:09 2013, Albert Yang, Update, optical tables, Optical Table Toolboxes 
For those of you who spend annoying amounts of time looking for tools, fear no more. Toolboxes for each optical table are coming!
They will probably have:
IR Viewer (a few optical tables will have IR viewers, these specific tables will be labeled in the diagram coming out later)
Entry  Mon Apr 1 16:16:16 2013, Albert, Update, optical tables, Optical Table Toolboxes Update 
A heavy duty plastic box is the likeliest candidate for the optical table toolbox. It measures 5 9/16 in. x 11 5/8 in. x 4 5/8 in. and fits all the tools
comfortably. ( http://www.mcmaster.com/#plastic-bin-boxes/=m4yh4m  ,  under
Heavy Duty Plastic Bin Boxes)
    Reply  Mon Apr 1 16:35:42 2013, Albert, Update, optical tables, Optical Table Toolboxes Update 


    
        
            Quote:
        
        
            

           A heavy duty plastic box is the likeliest candidate for the optical table toolbox. It measures 5 9/16 in. x 11 5/8 in. x 4 5/8 in. and fits
    Reply  Wed Apr 3 19:01:06 2013, Albert, Update, optical tables, Optical Table Toolboxes Update 


    
        
            Quote:
        
        
            

           
            
                
           
    Reply  Thu Apr 11 16:29:23 2013, Albert, Update, optical tables, Optical Table Toolboxes Update Diagram.png


    
        
            Quote:
        
        
            

            There are some tips for how to appy nail polish on YouTube from MKNails and MissJenFABULOUS. Their tips on how to prepare the site
    Reply  Mon Apr 15 17:44:28 2013, Albert, Update, optical tables, Optical Table Toolboxes Update photo.JPG
I decided to go see what the electrical tape looks like on the other tools.
These are the tools I felt were necessary to label with tape: (the others don't seem to be terribly important in terms of not interchanging between
boxes)
    Reply  Mon Apr 29 08:17:40 2013, Albert, Update, optical tables, Optical Table Toolboxes Update 


    
        
            Quote:
        
        
            

           I decided to go see what the electrical tape looks like on the other tools.
    Reply  Mon Apr 29 15:53:49 2013, Albert, Update, optical tables, Optical Table Boxes 7x


    
        
            Quote:
        
        
            

            
    Reply  Fri Jul 30 19:20:15 2010, Alastair, Configuration, General, Jacket 


    
        
            Quote:
        
        
            
            Jenne and I need our jackets. We removed them from the Rb clock.
Entry  Thu Aug 5 16:18:37 2010, Alastair, Update, General, clocks still not locked fully - hut removed 
The rubidium clocks are still not quite locked together, though it is clear that the beat frequency has dropped a lot since yesterday.
I checked on the clocks and the 1pps sync light is on.  The clocks are really hot again though despite the gap left at the bottom of the igloo. 
The side of the clocks were hot enough to not be touchable.
Entry  Wed Aug 18 12:02:29 2010, Alastair, Configuration, Computers, elog had crashed again... 
...I restarted it.
Entry  Thu Aug 19 09:52:51 2010, Alastair, Update, Computers, Elog down 
 I restarted it using start-elog-nodus and this worked out fine - even though I did it from Pete's on my phone ;-)
Entry  Thu Aug 19 11:38:48 2010, Alastair, Update, Computers, ATF wiki 
The ATF wiki page doesn't seem to be working any more.  Does anyone know where this is held so we can try to get it back online?  Thanks 
    Reply  Thu Aug 19 12:06:07 2010, Alastair, Update, Computers, ATF wiki 


    
        
            Quote:
        
        
            
            The ATF wiki page doesn't seem to be working any more.  Does anyone know where this is held so we can try to get
Entry  Fri Aug 20 20:36:05 2010, Alastair, Update, General, Elog 
 Elog was down, I restarted it.
Entry  Tue Aug 24 06:34:01 2010, Alastair, Update, General, Elog... 
...was down.  Have restarted it.
Entry  Fri Aug 27 07:21:13 2010, Alastair, Update, General, elog... 
 was down.  I restarted the version in the 2.7.5 folder.  It went down again almost immediately but stayed up after the second restart.
Entry  Mon Apr 25 11:23:41 2011, Alastair, Bureaucracy, Computers, wiki? 119427.strip.gif
40m wiki seems to have been down for quite a while now but I can't see any info in the elog about it.  Is there some ongoing problem?
    Reply  Mon Apr 25 12:55:35 2011, Alastair, Bureaucracy, Computers, wiki? 


    
        
            Quote:
        
        
            
            
            
    
Entry  Tue Jun 28 11:25:56 2011, Alastair, Bureaucracy, Computers, restarted elog 
The manual instructions on the 40m wiki for restarting wouldn't work.  I killed the process okay, but then I got an error saying it "couldn't
bind to port 8080, please try again using -p to select port".  The automated script worked though.
    Reply  Sun Feb 10 20:47:01 2008, Alan, Summary, SUS, All watchdogs tripped 
A moderate earthquake occurred at 11:12:06 PM (PST) on Friday, February 8, 2008.
The magnitude 5.1 event occurred 21 km (13 miles) NW of Guadalupe Victoria, Baja California, Mexico.
http://quake.wr.usgs.gov/recenteqs/Quakes/ci14346868.html
    Reply  Mon Oct 20 12:18:38 2008, Alan, Update, Computer Scripts / Programs, burtwb missing on Solaris but installed on linux64 
[quote]c1lsc stalled this evening, so I powercycled it.
After that, I tried to lock arms to confirm the computer is working.
Then I realized that the restore alignment buttons do not work from any control room computer.
    Reply  Mon Oct 20 16:18:00 2008, Alan, Configuration, Computers, /cvs/cds restored 
[quote]I moved missing files in /cvs/cds restored by Alan and Stuart to the original locations.
I confirmed autoburt runs, and dtt, which had also been having trouble running, runs ok now.