  7708   Tue Nov 13 21:05:35 2012 DenUpdateAdaptive Filteringonline and simulationFor a last few days I've been working on
oaf and simulink model to simulate it. First
I did online subtraction from MC when MC_L
 8x 
  7764   Fri Nov 30 02:40:44 2012 DenUpdateAdaptive FilteringYARMI've applied FIR adaptive filter to YARM
control. Feedback signal of the closed loop
was used as adaptive filter error signal
 yarm_oaf.png 
  7767   Fri Nov 30 11:49:24 2012 KojiUpdateAdaptive FilteringYARMThis is interesting. I suppose you are
acting on the ETMY.
Can you construct the compensation
  
  7769   Fri Nov 30 22:11:50 2012 DenUpdateAdaptive FilteringARMS

    

       
            
 arms_oaf.pdf 
  7771   Sat Dec 1 00:13:16 2012 DenUpdateAdaptive FilteringARMS and MC

    

       
            
 arms_mcl_oaf.pdf 
  14010   Sat Jun 23 13:08:41 2018 JonUpdateAUXFirst Coherent AUX Scan of PRC Using AM Sidebands[Jon, Keerthana, Sandrine]

Thu.-Fri. we continued with PRC
scans using the AUX laser, but now the "scanned"
 IMG_2695.jpegIMG_2698.jpegIMG_2699.jpeg 
  14011   Sat Jun 23 20:54:35 2018 KojiUpdateAUXFirst Coherent AUX Scan of PRC Using AM SidebandsHow much was the osc freq of the marconi?
And then how much was the resulting freq
offset between PSL and AUX?
  
  14017   Tue Jun 26 10:06:39 2018 keerthanaUpdateAUXFirst Coherent AUX Scan of PRC Using AM Sidebands(Jon, Keerthana, Sandrine)

I am attaching the plots of the
Reflected and transmitted AUX beam. In the
 TRANS.pdfREFL.pdf 
  14035   Tue Jul 3 11:59:10 2018 JonUpdateAUXAUX Carrier Scan of Y-Arm CavityI made the first successful AUX laser scan
of a 40m cavity last night.

Attachment #1 shows the measured
 yarm_carrier_trans.pdfAG4395A_02-07-2018_185504.txt 
  14036   Wed Jul 4 19:11:49 2018 JonUpdateAUXMore Testing of AUX-Laser Mode ScanningMore progress on the AUX-laser cavity scans.

Changes to the Setup


For
scans, the Agilent is now being used as a
 yarm_trans_70uW.pdfprc_trans_9mW.pdfyarm_carrier_trans_70uW.tar.gzprc_carrier_trans_9mW.tar.gz 
  14044   Sun Jul 8 12:20:12 2018 JonSummaryAUXGouy Phase Measurements from AUX-Laser ScansThis note reports analysis of cavity scans
made by directly sweeping the AUX laser carrier
frequency (no sidebands). The measurement
 yarm_aux_carrier_trans.pdfprmi_aux_carrier_trans.pdfdrmi_aux_carrier_trans.pdf 
  Draft   Wed Jul 11 18:13:19 2018 keerthanaSummaryAUXGouy Phase Measurements from AUX-Laser ScansFrom the Measurement Jon made, FSR is 3.967
MHz and the Gouy phase is 52 degrees. From
this, the length of the Y-arm cavity
  
  14062   Fri Jul 13 00:15:13 2018 Annalisa, TerraConfigurationAUXY arm cavity scan [Annalisa, Terra, Koji, Gautam]

Summary: We
find a configuration for arm scans which
 IMG_6492.JPGIMG_6494.JPG 
  14091   Fri Jul 20 18:30:47 2018 JonConfigurationAUXRecommend to install AUX PZT driverI recently realized that the PLL is only
using about 20% of the available actuation
range of the AUX PZT. The +/-10 V control
  
  14501   Fri Mar 29 15:47:58 2019 gautamUpdateAUXAUX laser fiber moved from AS table to PSL table[anjali, gautam]

To facilitate the 1um MZ frequency
stabilization project, I decided that the
  
  14504   Sun Mar 31 18:39:45 2019 AnjaliUpdateAUXAUX laser fiber moved from AS table to PSL table

Attachment #1 shows the schematic
of the experimental setup for the frequency
noise measurement of 1 um laser source.
 Schematic_of_experimental_setup_for_frequency_stabilisation_of_1_micron_source.png1_micron_setup_for_frequency_noise_measurement.JPG1_micron_setup_for_frequency_noise_measurement_power_levels.png 
  16194   Wed Jun 9 11:46:01 2021 Anchal, PacoSummaryAUXXend Green Laser PDH OLTF measurementWe measured the Xend green laser PDH Open
loop transfer function by following method:


We first measured the feedback
 image-6f2923a3-01ce-4d04-bc53-d8db0238e195.jpgimage-72223f4b-3b74-4574-a7ad-de6628a2c5e9.jpgX_Green_ARM_PDH_OLTF.pdf 
  16197   Thu Jun 10 14:01:36 2021 AnchalSummaryAUXXend Green Laser PDH OLTF measurement loop algebraAttachment 1 shows the closed loop of Xend
Green laser Arm PDH lock loop. Free running
laser noise gets injected at laser head after
 AUX_PDH_LOOP.pdf 
  16200   Mon Jun 14 18:57:49 2021 AnchalUpdateAUXXend is unbearably hot. Green laser is loosing lock in 10's of secondsWorking in Xend with mask on has become
unbearable. It is very hot there and I would
really like if we fix this issue.
 XAUX_PDH_Err_In_ASD.pdfXAUX_PZT_Out_Mon_ASD.pdf 
  16202   Tue Jun 15 15:26:43 2021 Anchal, PacoSummaryAUXXend Green Laser PDH OLTF measurement loop algebra, excitation at control pointAttachment 1 shows the case when excitation
is sent at control point i.e. the PZT output.
As before, free running laser noise 
 AuxPDHloop.pdf 
  16213   Fri Jun 18 10:07:23 2021 Anchal, PacoSummaryAUXXend Green Laser PDH OLTF with coherenceWe did the measurement of OLTF for Xend
green laser PDH loop with excitation added
at control point using a SR560 as shown in
 XEND_PDH_OLTF_with_Coherence.pdfBeta_Amp.pdf 
  17243   Tue Nov 8 11:18:39 2022 RadhikaUpdateAUXAUX PZT transfer function fitting + filteringHere I describe efforts to cancel the AUX
laser PZT mechanical resonances from ~200
kHz-400kHz. While these may not be the resonances
 AUX_PZT_TF_vectfit.pdfAUX_PZT_TF_filtered.pdf 
  17244   Tue Nov 8 16:56:33 2022 ranaUpdateAUXAUX PZT transfer function fitting + filteringThis looks really good to me. Rather than
fully invert the plant, what we would like
to do is now design a filter which allow
  
  17759   Mon Aug 7 14:02:52 2023 RadhikaUpdateAUXxend AUX fully locking with Moku:GoMoku:Go
used for full locking of green laser - OLTF
to come

Picking up from
 IMG_5619.JPGIMG_5620.JPGIMG_5615.JPG 
  17773   Thu Aug 10 14:35:13 2023 RadhikaUpdateAUXXAUX out of loop error[Radhika, Yuta, Hiroki, Paco]

During YAUX noise measurements,
we also locked IR and green lasers in xarm
 ALS_X_outOfLoop_MokuGo_minus12dB.pdfALS_X_outOfLoop_MokuGo_minus14dB.pdf 
  387   Thu Mar 20 17:45:36 2008 ranaSummaryASSAdaptive Filtering in the ASS systemOver the past couple weeks we (Matt, Alex,
Rob, me) have worked on getting an adaptive
filter
  
  428   Fri Apr 18 19:46:08 2008 ranaUpdateASScheck adaptiveI restarted the adaptive code today using
'startass' and 'upass'. 
I moved them into the scripts/ASS/ subdirectory.
 0052_xray_thm45.jpg 
  432   Mon Apr 21 12:58:42 2008 robUpdateASScheck adaptive[quote]

Caryn Palatchi (a Caltech undergrad who just
  
  579   Thu Jun 26 21:07:11 2008 ranaConfigurationASSdust & MC1I realized today, that yesterday while we
were trying to debug the adaptive noise canceler,
I turned
 Screenshot-2.png 
  981   Mon Sep 22 21:54:05 2008 ranaUpdateASSNew Wiener result with x10 gain in ACCThe 2 attached PDF files show the performance
of the Wiener filter code on 2 hours of data
with a 4000 tap filter on 64 Hz data. All
 f.pdf 
  1105   Sun Nov 2 20:44:58 2008 ranaUpdateASSWiener Filter performance over 5 hoursI took one 2 hour stretch of data to calculate
a MISO Wiener filter to subtract the Ranger
seismometer
 f.pngf1.png 
  1111   Mon Nov 3 22:35:40 2008 ranaUpdateASSWiener Filter performance over 5 hours[FONT=Comic Sans MS]To speed up the Wiener
filter work I defined a 256 Hz version of
the original 16kHz IOO-MC_L signal. The
 DAQ.pdf 
  1112   Tue Nov 4 00:47:53 2008 ranaUpdateASSWiener Filter performance over 5 hoursSame as before, but now with a working Ranger
seismometer.
 f2.pngf.png 
  1985   Fri Sep 11 17:11:15 2009 SanjitUpdateASSOAF: progress made[Jenne & Sanjit]
Good news: We could successfully
send filtered output to MC1 @ SUS.
  
  2434   Sun Dec 20 21:39:40 2009 rana, jenne, kiwamuUpdateASSOAF Model update and build instructionsAfter a lot of headache, I
got the OAF working again - read on for details.....................
  
  2437   Mon Dec 21 02:22:31 2009 rana, jenne, kiwamuUpdateASSOAF Model update and build instructionsThis allowed measuring the MC1 -> MCL
TF finally. Its mostly flat. Data saved as
Templates/OAF/OAF-MCLTF.xml
 Untitled.png 
  2438   Mon Dec 21 07:30:58 2009 ???UpdateASSOAF Model update and build instructions What does OAF stand for? The entry
doesn't say that. Also the acronym is not
in the abbreviation page of the wiki.
  
  2440   Mon Dec 21 10:09:06 2009 jenneUpdateASSOAF Model update and build instructionsOAF stands for Online Adaptive Filtering.
 We use the same computer which was once
the ASS. One of these days, we'd like to
  
  2441   Mon Dec 21 19:24:29 2009 ranaUpdateASSOAF Model update and build instructionsI fit the MC1 -> MCL TF using vectfit4.m
(from mDV). The wrapper file is mDV/extra/C1/
fitMC12MCL.m.
 mc12mcl.png 
  2442   Tue Dec 22 02:50:09 2009 rana, kiwamu, jenneUpdateASSOAF Feedaround ON and doing something goodKiwamu made the OAF screen functional today
- screenshot attached.
After this, I used the measured TF
 oaf.pngoaf.png 
  2449   Wed Dec 23 17:33:14 2009 ranaUpdateASSOAF Feedaround ON and doing something goodThe Rai box ran out of batteries a couple
of days ago and so the data is no good. I've
put the Ranger back on the SR560 for now
  
  4696   Wed May 11 23:02:52 2011 valeraUpdateASSDither angular stabilizitaion system updateThis is what was done in past two days:
- The ETMY and ITMY pitch and yaw
dofs are modulated at 40, 44, 42, 46 Hz respectively
  
  4709   Fri May 13 00:39:53 2011 valeraUpdateASSc1ass updateHere the status of the dither alignment
or c1ass:
- Both pitch and yaw centering on
 c1assqpds.jpg 
  4726   Mon May 16 11:47:59 2011 kiwamuUpdateASSc1ass update part IIThe medm screen for c1ass started being
modified to be more user-friendly.
The modification is still 
 c1ass.png 
  4795   Wed Jun 8 16:41:48 2011 valeraUpdateASSX and Y arm dither alignment status   BeamPositionIndicators.png 
  6723   Thu May 31 01:20:41 2012 JenneUpdateASSASS filter outputs are non-zero with no inputI was looking a little at ASS, while Yuta
was doing some Green transmitted DC PD work,
and I find that the output of some filters
 ASS_Yarm_crazyOutputs_30May2012.png 
  6980   Tue Jul 17 11:28:29 2012 JenneUpdateASSNames of DoF filters in ASS wrongThe names of the DoF filters in the ASS
loop were wrong.  The filters themselves
were correct (low pass filters at super low
  
  7017   Tue Jul 24 03:14:13 2012 JenneUpdateASSCalibration of MC ASS lockinsI wanted to check that the calibration
of the MC ASS lockins was sensible, before
trusting them forevermore.
  
  7074   Wed Aug 1 22:37:21 2012 JenneUpdateASSFilters installed in the ASSAs part of trying to figure out what is
going on with the ASS, I wanted to figure
out what filters are installed on which lockins.
 ASS_lockin_filters_1Aug2012.pdf 
  7075   Thu Aug 2 00:43:55 2012 JenneUpdateASSMajor cleanup of the ASS model[Jamie, Jenne]