  7751   Tue Nov 27 01:03:42 2012 AyakaUpdateWienerFilteringSound on PSL Last Thursday, I put the speaker
and my laptop in the PSL table, and make
triangular wave sound with the basic frequency
 gauss_psdcoh_mcf.pngtri40_psdcoh_mcf.pnggauss_filters_mcf.pngGauss_estimatefilters_mcf.png 
  7760   Wed Nov 28 23:55:13 2012 AyakaUpdateWienerFilteringSound on PSL I have been searching for the way
we can subtract signal better since I could
see the acoustic coupling signal remains
 tri40_psdcoh_mcf_varioust.pnggauss_psdcoh_mcf_varioust.png 
  7789   Wed Dec 5 01:06:22 2012 AyakaUpdateWienerFilteringThe microphones and the speaker on the AP table In order to see the acoustic coupling
on arm signals, I set 6 microphones and the
speaker on the AP table. The microphones
 DSC_4956.JPGDSC_4961.JPGAPsig.pdf 
  7792   Wed Dec 5 09:53:01 2012 ranaUpdateWienerFilteringThe microphones and the speaker on the AP table  Don't
try to re-invent the mic mount: just copy
the LIGO mic mount for the first version.
  
  7824   Thu Dec 13 18:06:59 2012 AyakaUpdateWienerFilteringNew microphone mounts Yesterday, I made new mounts for
microphones.
 IMG_0129.JPGIMG_0130.JPG 
  8563   Mon May 13 17:24:38 2013 JenneUpdateWienerFilteringPRM YAW Wiener filteringI have done a quicky offline Wiener filter
to check how much PRM yaw motion we can subtract
using a seismometer in the corner station. 
 PRM_SUSYAW_subtractUsing_GUR1_xyz.png 
  11485   Thu Aug 6 21:03:45 2015 IgnacioHowToWienerFilteringHow to do online static IIR Wiener filteringIn order to do online static IIR Wiener
filtering one needs to do the following,

1) Get data for FIR Wiener filter
 iir.png 
  11552   Tue Sep 1 06:58:11 2015 IgnacioUpdateWienerFilteringMCL FF => WFS1 and WFS2 FF => ARMS FFI took some
training data during Sunday night/Monday
morning while the MCL MISO FF was turned
 6x 
  11880   Mon Dec 14 16:46:42 2015 ericqUpdateWienerFilteringNoise Subtraction PuzzlerHere's something to ponder.

Our online MCL feedforward uses
perpendicular vertex T240 seismometer signals
 subpuzz.pdf 
  11918   Thu Jan 7 15:29:54 2016 ericqUpdateWienerFilteringNoise Subtraction PuzzlerThe puzzle continues...

I found some reference for computing
"multicoherence," which should
 subpuzz2.pdfpuzzle.zip 
  11933   Thu Jan 14 15:08:37 2016 ericqUpdateWienerFilteringNoise Subtraction PuzzlerThe anticlimatic resolution to my subtraction
confusion: Spectral leakage around 1Hz. Increasing the
FFT length to 256 sec now shows that the
 subpuzz_resolved.pdf 
  11934   Thu Jan 14 18:41:36 2016 ranaUpdateWienerFilteringNoise Subtraction PuzzlerJust not just pedagogical !  Freq
domain MISO coherence based subtraction estimation
is much faster than calculating MISO WF.
  
  12059   Fri Apr 1 13:11:26 2016 ericqUpdateWienerFilteringBilinear Noise TestingI've been banging my head against bilinear
noise subtraction, and figured I needed to
test things on some real hardware to see
 bilinear_drive.pdf40m_bilin.pdf 
  10019   Tue Jun 10 11:54:36 2014 ZachConfigurationWikiDokuWikis are still downNot sure if someone is already on this,
but the nodus DokuWikis are still down (AIC,
ATF, Cryo, etc.)
  
  10021   Tue Jun 10 19:11:27 2014 EvanConfigurationWikiDokuWikis are back upAs of this writing, the DokuWiki   
  10022   Wed Jun 11 05:16:14 2014 ZachConfigurationWikiDokuWikis are back upIt looks like auth is broken on the AIC
wiki (though working fine on ATF and Cryo).
  
  10024   Wed Jun 11 10:15:15 2014 EvanConfigurationWikiDokuWikis are back up

    

       
            
  
  10029   Wed Jun 11 20:09:37 2014 ZachConfigurationWikiDokuWiki situationI have been looking into the DokuWiki
situation, with no great progress so far.
The problem is with authentication.
  
  10355   Fri Aug 8 16:45:40 2014 NichinUpdateWikiPDFR wiki updated The PDFR system has been documented
in the 40m wiki and all the relevant information
about making changes and keeping it updated
  
  10366   Mon Aug 11 23:50:38 2014 ranaConfigurationWikiDokuWikis are back up

    

       
            
  
  10393   Thu Aug 14 20:52:36 2014 ranaUpdateWikiViolin Mode table added to WikiMech
Resonance Wiki
I've updated the wiki by trawling
  
  12935   Mon Apr 10 15:22:46 2017 ranaConfigurationWikiDokuWikis are back upAIC Wiki updated
to latest stable version of DokuWiki: 
  
  13767   Thu Apr 19 09:57:03 2018 gautamUpdateWikiAP and ETMX tables uploaded to wikiThe most up to date pictures of the AP
table and ETMX table that Steve took have
been uploaded to the relevant
  
  13776   Fri Apr 20 16:25:08 2018 SteveUpdateWiki ETMX table layout uploaded to wikiETMX
table layout uploaded with beam paths
to the wiki.   
  
  13785   Tue Apr 24 15:59:23 2018 SteveUpdateWiki AP table layout 20180328


Quote:


 DSC00668AP20180328.png 
  14173   Tue Aug 21 09:16:23 2018 SteveUpdateWiki AP table layout 20180821 

 
 20180821.JPG 
  15429   Wed Jun 24 22:47:21 2020 YehonathanUpdateWikiUpdated phase maps webpageI uploaded the new phase maps measurements
made by GariLynn to nodus and updated the
optics phase maps page.

I
  
  15614   Tue Oct 6 07:37:20 2020 yehonathanUpdateWikiNew TIS measurements of 40m OpticsLiYuan has kindly done some Total Integrating
Sphere (TIS) measurements on ITMU01 and ITMU02.
A summary of the measurement is attached.
 ITMU_sn01-02_tis_1.pdf 
  16614   Mon Jan 24 12:33:41 2022 ranaConfigurationWikiAIC Wiki: txz files allowedI updated the mime.local.conf file for
the AIC Wiki so as to allow attachments with
the .txz
  
  17035   Mon Jul 25 18:22:30 2022 DeekshaSummaryWikiMeasured the PZT TF Successfully Measured the PZT beatnote using the setup
mentioned in elog post 17031. Attached is
the data taken from 10kHz to 1MHz, decadewise
 6x 
  1199   Sun Dec 21 13:00:06 2008 steveUpdateall down cond.vac and laser back onThere was a power outage sometimes early Saturday.

All things are down.
  
  2025   Tue Sep 29 23:43:49 2009 ranaAoGall down cond.Cosmic   Actel1.jpg 
  2344   Sun Nov 29 16:56:56 2009 robAoGall down cond.sea of redCame in, found all front-ends down.
 
Keyed a bunch of crates, no luck:
  
  2345   Mon Nov 30 10:28:47 2009 AlbertoAoGall down cond.sea of red

    
        
  
  2346   Mon Nov 30 11:29:40 2009 AlbertoAoGall down cond.sea of red

    
        
  
  2355   Sat Dec 5 14:41:07 2009 robAoGall down cond.sea of red, againTaking  a cue from entry 2346,
I immediately went for the nuclear
option and powered off fb40m.  Someone
  
  2356   Sat Dec 5 15:20:10 2009 JenneAoGall down cond.sea of red, again


   
        
            
  
  4011   Sun Dec 5 22:28:39 2010 ranaSummaryall down cond.power outageLooks like there was a power outage.
The control room workstations
were all off (except for op440m). Rosalba
  
  4012   Mon Dec 6 11:53:20 2010 josephb, kiwamuSummaryall down cond.power outageThe monitors for allegra and rossa's seemed
to be in a weird state after the power outage. 
I turned allegra and rossa on, but didn't
  
  4013   Mon Dec 6 11:57:21 2010 KojiSummaryall down cond.power outageI checked the vacuum system and judged
there is no apparent issue.
The chambers and annulus had been
  
  6039   Tue Nov 29 17:10:39 2011 DenUpdatedigital noiseSOS creationOne of the possibilities that we see a
large low-frequency digital noise is due
to Foton. I've checked the SOS coefficients
  
  6041   Tue Nov 29 18:31:40 2011 DenUpdatedigital noiseFoton error In the previous elog we've compared
Matlab and Foton SOS representations using
low-order filter. Now we move on to high
  
  6045   Tue Nov 29 22:19:26 2011 DenUpdatedigital noisestraight line I tried to understand what part of
the signal is corrupted while passing through
a digital straight line without any filters.
 real_coherence.jpgfloat_coherence.jpgdouble_coherence.jpg 
  6046   Tue Nov 29 22:54:49 2011 DenUpdatedigital noisesingle precision In the previous elog we've proved
that signals C1:SUS-MC3_LSC_EXCMON and  C1:SUS-MC3_LSC_OUTMON
are in single precision. Now we try to understand
 filter_coherence.jpgchby1_coherence.jpgbutter8_coherence.jpgbutter2_coherence.jpg 
  6061   Thu Dec 1 18:30:39 2011 Vladimir, DenUpdatedigital noiseFoton errorFoton Matlab Error 
   
We investigated
some more the discrepancy between Matlab
  
  6062   Fri Dec 2 17:43:46 2011 ranaUpdatedigital noiseFoton errorIt would be useful to see some plots so
we could figure out exactly what magnitude
and phase error correspond to "gross"
  
  6063   Fri Dec 2 20:16:41 2011 DenUpdatedigital noisefirst order transitionIn order to verify our theory about coherence
corruption in linear systems due to the line
 freqz.pdftrans.pdf 
  6083   Wed Dec 7 20:55:44 2011 Vladimir, DenUpdatedigital noiseMatlab error

    

       
            
 gain_cmp.png 
  7021   Tue Jul 24 21:16:55 2012 DenUpdatedigital noisequantization testI'm trying to get some intuition how digital
noise due to quantization shows up in iir
filters. I decided to do tests in C using
 iir_2.pngiir_8.png 
  7031   Wed Jul 25 16:55:01 2012 DenUpdatedigital noisenotch, lowpass filters Direct Form 2 is noisy in the first
test. This is the one similar to Matt's in
his presentation. Input signal was a sine
 6x 