    Reply  Tue Feb 19 08:06:02 2013, yuta, Update, Electronics, POP path set up but AS55 is broken 
I didn't use LED flash light. We learned from the past (elog #7355). I checked that POP55 and
REFL55/165/33/11 are clearly responding to flash flight, but I didn't expect that much difference in DC gain.
I wonder why we could align AS beam to AS55 in Feb 8 (elog #8030), but not in Feb 15 (
    Reply  Tue Feb 19 19:55:52 2013, yuta, Update, IOO, MC yaw input tuned MCdecenter_19Feb2013.png
[Jenne, Manasa, Yuta]

Since we levelled IMC stack, we had to center beam spots on MC mirrors again.
    Reply  Wed Feb 20 03:13:10 2013, yuta, Update, Alignment, clipping centering checklist ClippingCenteringChecklist.pdf
I attached clipping/centering checklist for the alignment.
Blue ones are the ones we checked today. Red ones
should be checked tomorrow. Circles indicate centering on the optics, rectangles indicate clipping check, and arrows indicate retro-reflecting
    Reply  Wed Feb 20 10:13:41 2013, yuta, Update, Alignment, PRC flashing brighter than last week 
After in-vac alignment work last night, PRC is flashing brighter than PRMI alignment last week.
My hypothesis is that "we aligned PRM to junk MI fringe last week". Possibly, we used MI fringe caused by AR reflection of ITMs, or MI
fringe reflected from SRM.
    Reply  Wed Feb 20 19:48:16 2013, yuta, Update, Alignment, BS table oplev re-arranged IFOALIGN_QPDs_OSEMs.png
[Sendhil, Yuta]

After aligning IFO and putting the access connector on, we also centered IPANG/IPPOS and all oplevs (except SRM).
    Reply  Wed Feb 20 20:15:29 2013, yuta, Update, Alignment, SRM oplev status 
Currently, SRM is misaligned in pitch so that SRM reflected beam hits on the top edge of SR3 (not on the mirror, but on the cage holding the mirror).
We also confirmed that SRM oplev beam is coming out from the chamber unclipped, and centered on QPD when SRM is "aligned".
    Reply  Wed Feb 20 20:58:37 2013, yuta, Update, Alignment, clipping centering checklist ClippingCenteringChecklist.pdf
Blue ones are the ones we checked yesterday.
Green ones are the ones we checked today.
Red ones are the ones we couldn't check.
    Reply  Wed Feb 20 21:56:08 2013, yuta, Update, Alignment, clipping centering checklist 
I'm not sure about the OMC situation at 40m. I think there are no direct beam reflected back into IFO from OMC path. There must be some backscatter,
but we have to open OMC chamber again to put a beam dump.
I don't think we want to put one in OMC path for this pump-down, but we can put a beam dump to dump reflected beam from mis-aligned SRM tomorrow,
Entry  Thu Feb 21 15:21:07 2013, yuta, Update, VAC, all heavy doors on, started pumping down annulus 
[Steve, Manasa, Jenne, Sendhil, Evan, Yuta]

We put heavy doors on ITMX/ITMY/BS chamber and started pumping down from annulus.
Entry  Sat Feb 23 00:34:28 2013, yuta, Update, Computers, crontab in op340m deleted and restored (maybe) 
I accidentally overwrote crontab in op340m with an empty file.
By checking /var/cron in op340m, I think I restored it.
But somehow, autolockMCmain40m does not work in cron job, so it is currently running by nohup.
Entry  Sat Feb 23 07:14:58 2013, yuta, Update, LSC, can't lock Y arm TRYPOY.png
I tried to align and lock Y arm for the first time after pumping.
But I couldn't lock Y arm for more than ~1 sec. Why?
    Reply  Sat Feb 23 15:26:26 2013, yuta, Update, Computers, crontab in op340m updated 
I found some daily cron jobs for op340m I missed last night. Also, I edited timings of hourly jobs to maintain consistency with the past. Some of them
looks old, but I will leave as it is for now.
At least, burt, FSSSlowServo and autolockMCmain40m seems like they are working now.
    Reply  Sat Feb 23 17:14:59 2013, yuta, Update, LSC, can't lock Y arm 
Jenne found that;
  0. If all mirrors are "aligned," Yarm flashes.
  1. If SRM is misaligned, Yarm doesn't flash.
Entry  Mon Feb 25 15:30:29 2013, yuta, Update, Alignment, Y arm locked, both colors 
[Koji, Yuta]

We aligned Y arm to Y green and tweaked TT1/TT2 to get IR locked in Y arm.
    Reply  Mon Feb 25 21:25:14 2013, yuta, Update, Alignment, both arms locked in IR QUAD1_1045890588.png
[Jenne, Evan, Yuta]

After Y alignment, X arm is aligned to IR and we got both arms locked in IR.
    Reply  Mon Feb 25 22:42:32 2013, yuta, Summary, Alignment, current IFO situation IPANGdrift.png
[Jenne,Yuta]

Both arms are aligned starting from Y green.
    Reply  Wed Feb 27 01:09:53 2013, yuta, Update, Locking, PRMI sideband/carrier locked 6x
[Jenne,Yuta]

We succeeded in locking PRMI in sideband and carrier.
    Reply  Wed Feb 27 11:22:54 2013, yuta, Update, Computers, backup crontab 
I made a simple script to backup crontab (/opt/rtcds/caltech/c1/scripts/crontab/backupCrontab).

#!/bin/bash
    Reply  Wed Feb 27 11:59:43 2013, yuta, Update, SUS, PRM/BS coil re-balanced PRM_f2a20130227.pngBS_f2a20130227.png
I re-adjusted coil gains and f2a filters for PRM and BS.
I'm not sure what happened to PRM since I balanced on Feb 16(elog #8093).
Let's see if it helps PRMI locking or not.
Entry  Thu Feb 28 02:43:49 2013, yuta, Update, LSC, some qualitative evidence of PRMI sideband lock PRMIsideband.png
[Manasa, Yuta]

Since we have setup POP22 PD now(elog #8192), we could confirm that sideband power builds
    Reply  Thu Feb 28 03:25:27 2013, yuta, Update, LSC, PR gain ~ 25 from PRMI carrier lock PRMIcarrier.png
[Manasa, Yuta]

We locked PRMI in carrier. Measured power recycling gain was ~25.
    Reply  Thu Feb 28 05:54:54 2013, yuta, Update, RF System, phase tracker: calibration ALS-BEATX_FINE_PHASE_OUT.pngALS-BEATY_FINE_PHASE_OUT.png
I swept the frequency of RF input to the beatbox to calibrate and check linearity range of phase tracker.
Calibration factors are;
  C1:ALS-BEATX_FINE_PHASE_OUT    52.1643 +/- 0.0003 deg/MHz
    Reply  Thu Feb 28 06:51:17 2013, yuta, Update, RF System, phase tracker: noise level frequencynoise.png
I measured noise level of the phase tracker by inputting constant frequency RF signal from marconi.
Measured frequency noise was ~2 Hz/rtHz @ 100 Hz. It's not so good.
    Reply  Fri Mar 1 16:58:37 2013, yuta, Update, LSC, Xarm oscillation stopped POX11_630Hz.png
POX11 oscillation at 630 Hz was stopped by installing 630 Hz resonant gain to LSC_XARM.
After few hours, oscillation stopped. So I removed the resonant gain.
Our guess is that 630 Hz peak is some violin mode or something, and it was excited somehow, and didn't stopped for very long time because of its
    Reply  Sat Mar 2 05:53:15 2013, yuta, Update, LSC, stable lock of PRMI LSCMICHOLTF_PRMI.pngLSCPRCLOLTF_PRMI.pngPRMtoAS55REFL55.png
I tuned alignment, gains and filters to achieve stable lock of PRMI.
It now locks quite stably with UGF of ~100 Hz. Measured power recycling gain at maximum is ~ 25.
    Reply  Sat Mar 2 20:09:12 2013, yuta, Update, RF System, phase tracker: DAQ noise limited frequencynoisewhitening.png
[Koji, Yuta]

We found that our phase tracker noise is currently limited by the noise introduced in DAQ. 
Entry  Mon Mar 4 16:46:31 2013, yuta, Update, SUS, oplev calibration for PRM PRM_PIT.pngPRM_YAW.png
[Manasa, Sendhil, Yuta]

We calibrated oplev for PRM. Calibration factor for C1:SUS-PRM_OL(PIT|YAW)_IN1 are;
Entry  Mon Mar 4 17:32:26 2013, yuta, Bureaucracy, General, flowchart for PRMI g-factor measurement PRMIgfactorPlan.png
I made a very useful flowchart for the week. Our goal for the week is to measure g-factor of PRC in PRMI.

Entry  Tue Mar 5 06:27:14 2013, yuta, Update, LSC, intra-cavity power dependence on mirror misalignment PRM_PIT_20130305a.pngPRM_YAW_20130305b.pngITMX_YAW_20130305.pngITMY_YAW_20130305.png
I measured intra-cavity power dependance on mirror misalignment.
Intra-cavity power of PRC in PRMI degrates roughly 20 % when there's 0.5 mrad 5 urad
misalignment. (edited by YM)
    Reply  Tue Mar 5 17:09:30 2013, yuta, Update, SUS, oplev calibration for ITMY ITMY_PIT.pngITMY_YAW.png
[Manasa, Sendhil, Yuta]

We calibrated oplev for ITMY. Calibration factor for C1:SUS-ITMY_OL(PIT|YAW)_IN1 are;
    Reply  Tue Mar 5 23:00:08 2013, yuta, Update, LSC, Yarm and PRC g-factor from misalignment measurement ITMY_YAW_20130305_DC.pngPRM_PIT_20130305a_DC.pngPRM_YAW_20130305b_DC.png
I fitted intra-cavity power dependance on mirror misalignment plot with parabola to get the g-factor.

  Y arm (tangential) g = 0.44 +0.01 -0.01  (measured value before was 0.3765 +/-
    Reply  Tue Mar 5 23:37:11 2013, yuta, Update, SUS, PRM angular motion spectra PRMangularmotion.png
I measured PRM angular motion spectra (in daytime today).
PRM angular motion is ~ 10 urad in RMS when undamped and ~1 urad in RMS when damped.
If PR2/PR3 angular motions are something like this, and their motion are not enhanced when PRC is locked, measured g-factor of PRC looks OK. But
    Reply  Thu Mar 7 01:43:35 2013, yuta, Update, LSC, calibrated MI differential length spectra LSCMICHOLTF_MI.pngMImotion.png
Free swing MI differential length is 86 nm RMS and residual length when locked is 0.045 nm RMS(in-loop).
Looks very quiet. Comparison with PRMI is the next step.
Entry  Thu Mar 7 18:12:03 2013, yuta, Update, Alignment, Input beam drift ~ 0.1 mrad/h in pitch IPangulardrift.png
[Jenne, Manasa, Yuta]

We temporarily centered the beam on IPANG to see input pointing drift. From eyeball, drift was ~ 0.1 mrad/h
Entry  Thu Mar 7 18:48:43 2013, yuta, Update, Computer Scripts / Programs, releasing my secret scripts 
I released/updated my secret scripts to real scripts directory.
I checked they run correctly (but maybe not working correctly).
    Reply  Fri Mar 8 02:17:04 2013, yuta, Update, LSC, calibration of PRM actuator calibREFL55Q.pngactcalibPRM.pngOLTF_PRCL.png
[Manasa, Yuta]

We measured AC response of PRM actuator using PRM-ITMY cavity.
    Reply  Fri Mar 8 03:07:19 2013, yuta, Update, LSC, calibrated PRM-ITMY length spectra LSCPRCLOLTF_PRITMY.pngPRITMYmotion.png
Measured free swing PRM-ITMY length was 230 nm RMS.
MI differential length was 85 nm RMS(elog #8248). This tells you that PR2, PR3 are not so noisy compared with usual suspensions.
Entry  Fri Mar 8 15:27:42 2013, yuta, Update, Green Locking, PSL green shutter installed 
[Manasa, Yuta]

Mechanical shutter for PSL green is installed right in front of PSL doubling crystal.
    Reply  Fri Mar 8 16:05:56 2013, yuta, Bureaucracy, General, action items for PRMI / ALS-FPMI 
We should focus our work both on PRMI and ALS-FPMI (elog #8250).

CDS:
    Reply  Wed Mar 13 08:34:33 2013, yuta, Update, Locking, TWO arms TWO colors 
- I took the shutter from AS table to use it for the PSL green. It was sitting near MC REFL path unused (elog
#8259).
Entry  Tue May 3 21:05:23 2022, yuta, Update, BHD, AS path alignment, removing a lot of green stuff 7x
[Tega, Yehonathan, Koji, Yuta]

We tried to align AS path this afternoon.
    Reply  Thu May 12 20:24:29 2022, yuta, Update, BHD, POX and POY investigation POY.JPG
[Anchal, Yuta]

We checked POX and POY RF signal chains for sanity check since Xarm cannot be locked in IR stably as opposed to Yarm.
    Reply  Mon May 16 13:22:59 2022, yuta, Update, BHD, REFL and AS paths aligned at AP table REFLPOP.JPGPOPAS.JPG
After Xarm and Yarm were aligned by Anchal et al, I aligned AS and REFL path in the AP table.
REFL path was alreasy almost perfectly aligned.

REFL path
    Reply  Thu May 19 18:56:08 2022, yuta, Update, BHD, Current OSEM sensor values with all the suspensions aligned OSEMS.txt
Current OSEM sensor values with all the suspensions aligned are attached.
For 'BS','ITMX','ETMX','ITMY','ETMY','PRM','SRM','LO1','LO2', the ones out
of the range [200,800] are marked, and for 'PR2','PR3','SR2','AS1','AS4', the ones out of the range [6000,24000]
    Reply  Wed May 25 16:38:27 2022, yuta, Update, SUS, Suspensions quick health check Screenshot_2022-05-25_16-46-13.pngOSEMcheck.JPG
[JC, Yuta]

We did a quick health check of suspesions after the pump down.

Summary:
    Reply  Wed May 25 17:34:47 2022, yuta, Configuration, BHD, IFO recovery - IFO alignment Screenshot_2022-05-25_17-47-57.png
IFO aligned to maximize flashings, except for GRY and LO-AS.

What we did:
    Reply  Thu May 26 19:55:43 2022, yuta, Configuration, BHD, Oplevs centered, BHD DCPDs are now online elog_1Y2.JPGelog_BHD.JPGelog_box.JPGScreenshot_2022-05-26_17-37-27_IFOaligned_OplevCentered.pngScreenshot_2022-05-26_20-35-02.png
[Paco, Yuta]

We have aligned the IFO (except for LO-AS and GRY), and centered all the oplevs.
We have also restored Gautam's in-air BHD DCPD setup and placed it to ITMY table.
    Reply  Fri May 27 17:45:53 2022, yuta, Configuration, BHD, BHD camera installed, GRY aligned 
[JC, Paco, Yuta]

After the IFO recovery (elog 40m/16881), we installed an analog camera for BHD fringe
    Reply  Wed Jun 1 11:56:28 2022, yuta, Update, ALS, Shutter driver for GRY replaced Screenshot_2022-06-01_12-01-53.png
[JC, Yuta]

We replaced a shutter driver for GRY since it stopped working this morning.
    Reply  Thu Jun 2 20:05:37 2022, yuta, Configuration, PSL, IMC input power recovered to 1W, some alignment works Before.JPGAfter.JPG