40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log, Page 335 of 337 |
Not logged in |
 |
|
New entries since: | Wed Dec 31 16:00:00 1969 | |
Tue May 3 13:18:47 2022, JC, Update, VAC, RGA Pump Down
|
Tue May 3 21:05:23 2022, yuta, Update, BHD, AS path alignment, removing a lot of green stuff 7x
|
Tue May 3 21:07:17 2022, Yehonathan, Update, BHD, BHD Readout simulation
|
Wed May 4 13:09:42 2022, Anchal, Update, BHD, IMC table balanced again, IMC is locking, YARM is locking
|
Wed May 4 15:08:59 2022, Tega, Update, BHD, XARM alignment to get flashing
|
Wed May 4 18:52:43 2022, Tega, Update, BHD, POP beam too high at POP SM4 on the ITMX chamber
|
Thu May 5 14:46:22 2022, Anchal, Update, BHD, POP beam height lowered, POP_SM4 raised
|
Thu May 5 17:05:31 2022, Tega, Update, BHD, IMC & X/Y-arm alignment
|
Thu May 5 17:50:48 2022, Yehonathan, Update, BHD, BHD Readout simulation
|
Fri May 6 13:48:34 2022, Anchal, Update, BHD, WFS loop instability fixed
|
Mon May 9 18:43:03 2022, Anchal, Update, BHD, ITMX table layout corrected
|
Mon May 9 18:49:05 2022, Tega, Update, BHD, Relocate green TRX and TRY PDs/cams/optics from PSL table to BS table 
|
Mon May 9 22:19:06 2022, Koji, Update, BHD, BHD Platform Progress status 
|
Mon May 9 23:18:44 2022, Koji, Update, BHD, BHD Platform Progress status 6x
|
Tue May 10 15:46:38 2022, JC, Update, BHD, Relocate green TRX and TRY components from PSL table to BS table 
|
Tue May 10 16:31:14 2022, Tega, Update, BHD, ITMX optlev return beam steered to QPD
|
Tue May 10 18:25:43 2022, Paco, Update, BHD, Green Transmission path
|
Wed May 11 15:49:42 2022, JC, Update, OPLEV Tables, Green Beam OPLEV Alignment
|
Thu May 12 13:46:59 2022, Jc, Update, Alignment, POP Beam
|
Thu May 12 17:20:08 2022, Paco, Update, Alignment, POP Beam on CCD
|
Thu May 12 19:55:01 2022, Tega, Update, BHD, AS path alignment 
|
Thu May 12 20:11:18 2022, Anchal, Update, BHD, BHDBS Output beams steered out to ITMY table
|
Thu May 12 20:24:29 2022, yuta, Update, BHD, POX and POY investigation
|
Fri May 13 14:26:00 2022, JC, Update, Alignment, LO2 Beam
|
Fri May 13 18:42:13 2022, Paco, Update, Alignment, ITMX and ITMY sat amp failures
|
Sat May 14 08:36:03 2022, Chris, Update, DAQ, DAQ troubleshooting
|
Mon May 16 10:49:01 2022, Anchal, Update, DAQ, DAQ troubleshooting
|
Mon May 16 12:59:27 2022, Chris, Update, DAQ, DAQ troubleshooting 
|
Mon May 16 13:22:59 2022, yuta, Update, BHD, REFL and AS paths aligned at AP table 
|
Mon May 16 14:46:35 2022, Tommy, Update, Electronics, RFSoC MTS Work
|
Mon May 16 16:13:01 2022, Yehonathan, Update, BHD, Initial BHD modeling: Damped suspension model  
|
Mon May 16 19:14:17 2022, Anchal, Update, BHD, Camera set on AS path and BHDBS output path
|
Tue May 17 18:43:38 2022, Anchal, Update, BHD, Placed SRM in ITMY Chamber
|
Wed May 18 08:30:29 2022, Paco, Update, BHD, SRM OpLev
|
Wed May 18 09:02:52 2022, Anchal, Update, BHD, WFS1 PD centered
|
Wed May 18 17:23:15 2022, Anchal, Update, BHD, Placed PRM in BS Chamber
|
Thu May 19 08:51:40 2022, Paco, Update, BHD, SRM OpLev
|
Thu May 19 18:56:08 2022, yuta, Update, BHD, Current OSEM sensor values with all the suspensions aligned
|
Thu May 19 19:05:59 2022, Anchal, Update, BHD, BS Chamber all work finished, BHD path setup
|
Fri May 20 12:42:23 2022, Tega, Update, VAC, Door installation on the end stations
|
Fri May 20 20:03:48 2022, Paco, Update, BHD, ITMY chamber work finished - LO and AS overlapped 
|
Mon May 23 13:16:59 2022, Paco, Update, BHD, End of vent - checks  
|
Tue May 24 10:37:09 2022, Tega, Update, VAC, added FRG channels to slow channel ini file
|
Tue May 24 11:04:53 2022, JC, Update, VAC, Beginning Pumpdown 
|
Tue May 24 15:21:13 2022, Anchal, Update, BHD, Freeswing tests of new SOS started
|
Wed May 25 16:38:27 2022, yuta, Update, SUS, Suspensions quick health check 
|
Thu May 26 15:55:10 2022, Tommy, Update, Electronics, RFSoC Power Spectrum
|
Fri May 27 12:15:30 2022, JC, Update, Electronics, CRT TV / Monitor 6
|
Fri May 27 15:53:17 2022, Tommy, Update, Electronics, RFSoC MTS Work
|
Tue May 31 14:44:02 2022, JC, Update, Electronics, CRT TV / Monitor 6
|
|