40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 335 of 344  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Date Author Type Categorydown Subject Text Attachments
  14987   Wed Oct 23 11:11:01 2019 gautamUpdateALSEX uPDH electronics checkoutThe closest thing I can think of is here.

  
  14993   Fri Oct 25 01:04:49 2019 gautamUpdateALSALS electronics chain was saturating[Koji, gautam]

Summary:

We think we got to the bottom of
  
  14995   Mon Oct 28 23:20:11 2019 gautamUpdateALSALS power budget 


IR
  
  15020   Thu Nov 7 17:46:10 2019 shrutiUpdateALSAM measurement at X endSome details:

- There
was a SR560+SR785 (not connected for measurement)
placed near the X end which I moved; it is
 AMTF20191107.png 
  15058   Mon Dec 2 00:27:20 2019 gautamUpdateALSGreen ALS resurrectionAttachment
#1 -
 ALSnoiseComparison.pdfALS_TR_RIN.pdfGreemAM.pdf 
  15059   Mon Dec 2 18:20:29 2019 gautamUpdateALSEY uPDH post mixer LPFAs part of characterization, I wanted to
calibrate the EY uPDH error point monitor
into units of Hz. So I thought I'd measure
 EY_uPDH_LPF.pdfEY_uPDH_OLTF.pdf 
  15060   Mon Dec 2 20:18:18 2019 ranaUpdateALSEY uPDH post mixer LPF         
         filter
Q seems too high, 
  
  15063   Tue Dec 3 00:10:15 2019 KojiUpdateALSEY uPDH post mixer LPFI got confused. Why don't we see that
too-high-Q pole in the OLTF? 
  
  15064   Tue Dec 3 00:51:25 2019 gautamUpdateALSEY uPDH post mixer LPFI'm not sure - maybe it was measurement
error on my part, I will double check. Moreover,
the EX
  
  15066   Tue Dec 3 18:15:42 2019 gautamUpdateALSEY uPDH post mixer LPFRana and I discussed this alogrythym a
bit today - here are some bullet points,
I'll work on preparing a notebook. We
  
  15068   Tue Dec 3 21:28:24 2019 gautamUpdateALSEY uPDH post mixer LPFHere are some loop transfer functions.
I basically followed the decomposition of
the end PDH loop as was done in the multi-color
 uPDH.pdf 
  15130   Fri Jan 17 18:02:21 2020 gautamUpdateALSGain blocks packaged and characterizedSummary:


The ZHL-1010+
gain blocks acquired from MiniCircuits
 photos.pdfgain.pdfnoise.pdfmeasSchem.pdfzhl1010Data.zip 
  15153   Fri Jan 24 17:14:01 2020 gautamUpdateALSGain blocks installedJordan will write up the detailed elog
but in summary,


Former +24V Sorensen in
  
  15157   Sun Jan 26 14:40:55 2020 gautamUpdateALSALS OOL noiseIn preparation for resuming IFO locking
activities, I measured the ALS noise with
the arm lengths locked to IR, AUX laser frequencies
 ALSnoise_20200126.pdf 
  15206   Tue Feb 11 16:39:00 2020 shrutiUpdateALSAM/PMThe results of the AM/PM measurements:


Attachment 1: Traces
of 9 AM TFs overlaid on top of each other,
 AM.pdfPM.pdfRatio_all.pdfRatios_FM_PM.pdfRatio_all_new.pdf 
  15209   Thu Feb 13 01:47:39 2020 gautamUpdateALSFast ALS - delay line prepA few years ago, Koji and I setup a delay
line phase shifter, which can be used to
impart a (switchable) delay to a signal path.
 delaySlider.pngdelayLineLosses.pdfdelayLineCal.pdf 
  15211   Thu Feb 13 21:30:55 2020 shrutiUpdateALSALS OOL noise with arms locked[Meenakshi, Gautam, Shruti]

Summary:

- We initially aligned the arm
 20200213_ALS.pdf 
  15212   Fri Feb 14 00:53:50 2020 gautamUpdateALSFast ALS - more setupIn the process of setting up some cabling
at 1Y2, I must've bumped a cable to the
c1lsc expansion chassis. Anyways, the c1lsc
 CMSlow_ALSnoise.pdfOLTFmeas.pdf 
  15213   Fri Feb 14 14:02:13 2020 shrutiUpdateALSALS OOL noise with arms locked[Meenakshi, Shruti]

Even though we were not able to
lock the the IR beat (by enabling LSC) during
 819472_10.pdf225642_10.pdf693500_10.pdf 
  15214   Fri Feb 14 14:52:41 2020 gautamUpdateALSALS OOL noise with arms lockedUnlikely, the alignment was probably just
not good. I restored the alignment and now
the arms can be locked to IR frequency.
  
  15216   Tue Feb 18 18:14:59 2020 shrutiUpdateALSALS OOL noise with arms lockedWe proceeded with the trying to measure
the ALS out-of-loop noise of the X arm when
the X arm cavity is green-locked using different
 ALSNoise.pdf 
  15217   Wed Feb 19 22:20:22 2020 ranaUpdateALSALS OOL noise with arms lockedCould you please put physical units on
the Y-axis and also put labels in the legend
which give a physical description of what
  
  15218   Fri Feb 21 10:59:08 2020 shrutiUpdateALSPDH error signals?   IMG_0082.jpgIMG_0083.jpgIMG_0084.jpgIMG_0085.jpg 
  15219   Fri Feb 21 13:02:53 2020 KojiUpdateALSPDH error signals?Check out this elog:
ELOG
4354
  
  15220   Fri Feb 21 20:44:18 2020 shrutiUpdateALSALS OOL noise and PDH[Meenakshi, Shruti]

In order to adjust the relative
phase for PDH locking, we used the Siglent
 ALSNoise.pdfIMG_0086.jpg 
  15221   Sun Feb 23 18:15:22 2020 ranaUpdateALSALS OOL noise and PDHto
make the comparisons meaningfully
  
  15233   Thu Feb 27 22:45:40 2020 gautamUpdateALSALS noise highThere was some UNELOGGED work at EX today.
The DFD outputs were also hijacked for loss
measurement. Unclear
 ALSnoise.pdf 
  15315   Fri May 1 01:49:55 2020 gautamUpdateALSASY commissioningSummary:

It appears that the EY green steering
PZTs have somehow lost their bipolar actuation
  
  15316   Fri May 1 22:44:17 2020 gautamUpdateALSASY M2 PZT damagedI went to EY and saw that the HV power
supply was only putting out 50 V and had
hit the current limit of 10 mA (nominally,
  
  15317   Sat May 2 02:35:18 2020 KojiUpdateALSASY M2 PZT damagedYes, we are supposed to have a few spare
PI PZTs.
  
  15319   Wed May 6 00:31:09 2020 gautamUpdateALSOptomechanics during CARM offset reductionSummary:

The apparent increase in the ALS
noise (witnessed in-loop, e.g. 
 CARMplant.pdfCARMplant_force2disp.pdf 
  15482   Wed Jul 15 17:46:05 2020 anchalSummaryALSNoise budget for ALS I started my attempt on noise budgeting
of ALS by going back to how Kiwamu did it
and adding as many sources as I could find
 ALS_nb.pdf 
  15496   Mon Jul 20 19:21:16 2020 anchalSummaryALSFew proposals for Voyager ALSI've added 4
proposed schemes for implementing ALS
in voyager. Major thing to figure out is
 VoyagerALSSchemes.pdf 
  15531   Mon Aug 17 23:36:10 2020 gautamUpdateALSWhitening and ALS noiseI finally managed to
install a differential-receiving whitening
board in 1Y2 - 4 channels are available at
 ALSimprovement.pdf 
  15533   Tue Aug 18 13:55:23 2020 ranaUpdateALSWhitening and ALS noiseNo, there should be no unscheduled visits
from any inspector, marshal, tech, or vendor.
They all have to be escorted or they don't
  
  15587   Sat Sep 19 23:59:22 2020 anchalSummaryALSALS noise budget updateSetting the record straight

I
found out an error I did in copying some
control model values from Kiwamu's matlab
 ALS_nb_ExtraPoles.pdfALS_controls.yamlALS_nb_Kiwamus_Values.pdfALS_controls_Kiwamus_Values.yamlALS_simulink_model.svg 
  15589   Sun Sep 20 23:12:13 2020 ranaSummaryALSALS noise budget updateI think the digital loop in the ALS budget
is too optimistic. You have to include all
the digital delays and anti-aliasing filters
  
  15593   Tue Sep 22 00:14:43 2020 anchalSummaryALSALS noise budget updateThis is not a reply to comments
given to the last post; Still working on
incorporating those suggestions.
 ALS_NoiseBudgetUpdate.pdfALS_controls.yaml 
  15594   Tue Sep 22 12:14:42 2020 ranaSummaryALSALS noise budget updateThis ALS loop is not stable. Its one of
those traps that comes from using only the
Bode plot to estimate the loop stability.
  
  15601   Wed Sep 23 11:13:49 2020 anchalSummaryALSALS noise budget updateYes, that loop was unstable. I started
using the time domain response to check for
the stability of loops now. I have been able
 ALS_NoiseBudgetUpdate.pdfALS_controls.yaml 
  15617   Wed Oct 7 16:56:23 2020 anchalSummaryALSALS noise budget update - Updated AUX PDH Loop valuesAUX PDH Loop update

I
used D1400293
to get the latest logged details about the
 Extract_X_AUX_PDH_Model.zipALS_NoiseBudgetUpdate.pdf 
  15619   Thu Oct 8 11:59:52 2020 ranaSummaryALSALS noise budget update - Updated AUX PDH Loop valuesFor all the loops where we drive the NPRO
PZT, there is some notch/resonance feature
due to the PZT mechanical resonance. In the
  
  15622   Fri Oct 9 18:32:14 2020 anchalSummaryALSALS noise budget update - Updated AUX PDH Loop valuesThe only two PZT Phase modulation transfer
function measurements I could find are 40m/15206
  
  15626   Wed Oct 14 17:03:55 2020 anchalSummaryALSALS noise budget update - Added whitening filter for ADCKoji recommended that I can add whitening
filters to suppress ADC noise easily. I added
a filter before ADC in ALS loop with 4 zeros
 ALS_NoiseBudgetUpdate.pdf 
  15751   Wed Jan 6 22:47:41 2021 gautamUpdateALSNoisy ALSSummary:

I want to get back to locking the
interferometer so I can test out the newly
 ALSX_excess.pngbudget.pdf 
  15752   Thu Jan 7 19:16:11 2021 gautamUpdateALSNoisy ALSI'm also wondering why the error monitors
for the X and Y loops report such wildly
different spectra for the suppressed frequency
 ALS_ERR_MON.pdfAUXnoise.pdf 
  15753   Thu Jan 7 20:07:27 2021 KojiUpdateALSNoisy ALSHow about resurrecting the PSL table green
beat for the X arm to see if the non-fiber
setup shows the same level of the freq noise
  
  15754   Thu Jan 7 21:16:22 2021 gautamUpdateALSNoisy ALSI thought about it, but wouldn't that
show up at the AUX PDH error point? Or because
the loop gain is so high there we wouldn't
  
  15755   Thu Jan 7 23:25:19 2021 KojiUpdateALSNoisy ALSIf the sensing noise level of the end PDH
degraded for some reason, it'd make the
out of loop stability worse without making
  
  15756   Fri Jan 8 20:01:11 2021 gautamUpdateALSNoisy ALSI did this test today. The excess
noise around 100 Hz doesn't show up in
the green beat.
 ALSX_IR_green.pdf 
ELOG V3.1.3-