  1655   Fri Jun 5 02:59:03 2009 pete, albertoUpdateLockingtdsavg failure in cm_step scriptthe command
tdsavg 5 C1:LSC-PD4_DC_IN1
was causing grievous woe in the cm_step
  
  1656   Fri Jun 5 13:51:49 2009 robUpdateLockingtdsavg failure in cm_step script


   
        
            
  
  1657   Fri Jun 5 16:45:28 2009 rob, peteHowToComputerstdsavg failure in cm_step script


   
        
            
  
  6795   Mon Jun 11 22:51:11 2012 JenneUpdateComputerstdsavg not workingtdsavg isn't working:
controls@rossa:/opt/rtcds/caltech/c1/scripts/LSC
6$ tdsavg 10 C1:LSC-ASDC_IN1
  
  6866   Mon Jun 25 11:23:14 2012 JenneUpdateComputerstdsavg not working

    

       
            
  
  6319   Fri Feb 24 23:14:09 2012 kiwamuUpdateCDStdsavg went crazyI found that the LSCoffset script didn't
work today. The script is supposed to null
the electrical offsets in all the LSC channels.
  
  1178   Fri Dec 5 01:58:58 2008 YoichiConfigurationASCtdscntr.pl now works at 40mTobin gave me the perl version of tdscntr
some time ago.
Pinkesh and I modified and tested it at LHO.
  
  1362   Thu Mar 5 23:18:38 2009 KakeruConfigurationComputerstdsdata doesn't workI found that tdsdata doesn't work.

When I star tdsdata, he takes a few ~ 10
  
  1371   Sun Mar 8 23:14:52 2009 ranaUpdateComputer Scripts / Programstdsdata doesn't workMatt logged in and rebuilt the
TDS stuff for us on Mafalda in /cvs/cds/caltech/apps/linux/tds_090304.
  
  1375   Mon Mar 9 14:57:30 2009 KakeruUpdateComputer Scripts / Programstdsdata doesn't workI tested new tdsdata and found it was working
well.
I excited C1:SUS-ITMY_SUSPIT_EXC
 oldtds.pngnewtds.png 
  1376   Mon Mar 9 16:54:52 2009 Kakeru, RanaUpdateComputer Scripts / Programstdsdata doesn't workWe confirmed that new tds(/cvs/cds/caltech/apps/linux/tds_090304/)
works well on linux 64, and replaced it to
/cvs/cds/caltech/apps/linux/tds/
  
  1380   Mon Mar 9 23:13:22 2009 YoichiUpdateComputer Scripts / Programstdsdata doesn't work


   
        
            
  
  1328   Fri Feb 20 01:54:18 2009 KakeruUpdateComputer Scripts / Programstdsdata might have a bugI found a strange jump of value in my data
taken with tdsdata.
I couldn't find same jump in
 jumped_data.png 
  430   Sun Apr 20 20:29:46 2008 ranaUpdateComputer Scripts / Programstdsread bugs[COLOR=darkred]There seems to be a problem
with reading the C1:IOO-MASTER_OVERFLOW field
  
  433   Mon Apr 21 13:12:21 2008 robUpdateComputer Scripts / Programstdsread bugs[quote][COLOR=darkred]There seems to be a
problem with reading the C1:IOO-MASTER_OVERFLOW
field 
  
  180   Fri Dec 7 14:14:48 2007 robMetaphysicsComputer Scripts / Programstdsread problems on Solaris
[COLOR=darkblue]tdsread[/COLOR] has developed
a strange new illness, whereby it cannot
  
  1702   Thu Jun 25 17:27:42 2009 ranaUpdateComputerstdsresp on linux I downloaded the tdsresp.pl from LLO and put
it into the various TDS/bin paths. Also updated
the LLO specific path stuff. It runs.
  
  1699   Wed Jun 24 14:43:19 2009 robUpdateComputerstdsresp on linux => pzresp 
tdsresp is broken on our linux control
room machines.  I made a little perl
  
  73   Tue Nov 6 23:45:38 2007 tobinConfigurationComputerstektronix scripts!I cooked up a little script to fetch the data
from the networked Tektronix scope.  Example
usage:
  
  1769   Tue Jul 21 17:01:18 2009 peteDAQDAQtemp channel PEM-PETER_FEI added a temporary channel, to input 9
on the PEM ADCU.    Beware
the 30, 31, and 32 inputs.  I tried
  
  13214   Wed Aug 16 16:05:53 2017 KiraUpdatePEMtemp sensor PCBTried taking the circuit from the breadboard
to the PCB. I attached all the components
to adapters that would allow them to be connected
 IMG_20170816_154514.jpgIMG_20170816_154541.jpg 
  13224   Thu Aug 17 10:41:58 2017 KiraUpdatePEMtemp sensor PCBGot it to work. One of the connections
was faulty. I decided to check the temperature
measured against a thermometer. The sensor
 IMG_20170817_095917.jpg 
  13232   Mon Aug 21 13:07:08 2017 KiraUpdatePEMtemp sensor PCBOn Friday, I cleaned up the circuit so
that there are only three connections needed
(+15V, -15V, GND) and a BNC connector for
 IMG_20170821_124121.jpgIMG_20170821_124429~2.jpgIMG_20170821_124108.jpg 
  7244   Tue Aug 21 15:26:04 2012 SteveUpdatePEMtemp sensor for vacuumTemperature sensor for vacuum. How many
: 2 or 3 ?  $350 each
Glass encapsulated thermistor
  
  13651   Thu Feb 22 16:16:43 2018 KiraUpdatePEMtemp sensor inputRewired the temperature sensor inputs to
Molex connectors so that we can now attach
them to the +/- 15V Sorensens for input instead
 IMG_20180222_160602.jpg 
  13656   Mon Feb 26 16:22:10 2018 KiraUpdatePEMtemp sensor input[Kira, Gautam]

We began the setup for the lab
temperature sensor today. First, we needed
 1.jpgIMG_20180226_154649.jpgIMG_20180226_154720.jpg 
  13660   Wed Feb 28 12:31:28 2018 KiraUpdatePEMtemp sensor inputI switched out the DIN fuses for the long
cables and it fixed the issue of them
not showing any votage on the other end.
  
  13209   Tue Aug 15 11:50:21 2017 KiraSummaryPEMtemp sensor packaging/mountFor the final packaging/mounting of the
sensor to the seismometer, I have thought
of two options.
  
  13285   Fri Sep 1 15:46:12 2017 KiraUpdatePEMtemp sensor updateI took off the AD590 and attached it to
two long wires leading out from the board.
This will allow us to attach the sensor to
 IMG_20170901_144729.jpg 
  13295   Tue Sep 5 17:18:17 2017 KiraUpdatePEMtemp sensor updateToday, I stuck on the sensors to a metal
block using a flag, rubber bands, and some
thermal paste (1st attachment). I then wrapped
 IMG_20170905_144924.jpgIMG_20170905_165042.jpg 
  13296   Tue Sep 5 17:52:06 2017 KiraUpdatePEMtemp sensor updateto get the sensors to read the same values
they have to be in direct thermal contact
with the metal block - there can't be
  
  13303   Fri Sep 8 10:22:30 2017 SteveUpdatePEMtemp sensor updateThe weight of SS can with copper liner 
is 12.2 kg

Is 1 Amp for the heating jacket
  
  13311   Tue Sep 12 11:44:16 2017 KiraUpdatePEMtemp sensor updateGot it to work. A cable was broken and
the AD586 also broke at the same time so
it took a while to find the problem. I had
  
  1161   Mon Nov 24 19:15:16 2008 rana, alberto, johnConfigurationEnvironmenttemperatureThe PSL Room Temperature was alarming because
it had gone above 23 C. This set off an unfortunate
chain of events:
  
  1163   Tue Nov 25 19:29:15 2008 rana, alberto, johnConfigurationEnvironmenttemperature[quote]The PSL Room Temperature was alarming
because it had gone above 23 C. This set
off an unfortunate chain of events:
  
  1164   Thu Nov 27 22:56:42 2008 ranaConfigurationEnvironmenttemperature8-)  mc.png 
  13611   Tue Feb 6 16:58:19 2018 KiraUpdatePEMtemperature measurementsI decided to plot the temperatures measured
over two days for the sensor inside the can
and inside the lab just to see if there was
 temps.png 
  1331   Sun Feb 22 23:43:07 2009 carynSummaryGeneraltemperature sensorComparing  PSL-FSS-RMTEMP and PEM-MC1-TEMPS
So, to compare temp channels, I made
a plot of PSL-FSS_RMTEMP and PEM-MC1_TEMPS(the
 12x 
  13183   Thu Aug 10 14:13:23 2017 KiraSummaryPEMtemperature sensorGoal is to build a temperature sensor accurate
to 1 mK. Schematic is shown below. This does
not take into account the DC gain that occurs.
 IMG_20170810_121637~2.jpgIMG_20170810_134422~2.jpg 
  13188   Thu Aug 10 21:22:06 2017 ranaSummaryPEMtemperature sensor
Should we use the AD590 or the
AD592? They're sort of the same, but
have slightly different packages and specs.
Given
 tempsensnoise2.pdftempnoise_final.pdf 
  13190   Fri Aug 11 10:27:49 2017 KiraUpdatePEMtemperature sensorSince there seems to be little difference
between AD590 and AD592, I guess we could
just go with the AD590. The temperature noise
  
  13191   Fri Aug 11 10:48:39 2017 KiraUpdatePEMtemperature sensorQuick update: we actually have AD587KRZ
and AD592, so we could start by using that
and seeing how it works.
  
  13193   Fri Aug 11 11:56:02 2017 ranaUpdatePEMtemperature sensorMight as well order several of a few different
varieties today. Its good to have some extra
in stock; we don't always want to have
  
  13194   Fri Aug 11 12:27:25 2017 KiraUpdatePEMtemperature sensorUsed AD592CNZ and AD586 (5V output) to
create a circuit that works and is responsive
to temperature changes. At room temp, using
 IMG_20170811_121608.jpgIMG_20170811_121619.jpg 
  13202   Mon Aug 14 09:49:18 2017 KiraUpdatePEMtemperature sensorDecided to try adding in an OP amp just
to see if it would work. Added LT1012
and a 100k resistor to the circuit (I originally
 IMG_20170814_092452.jpgIMG_20170814_092513.jpg 
  13203   Mon Aug 14 12:52:33 2017 KiraUpdatePEMtemperature sensorI didn't realize that the LT1012 needed
an additional input to function. I added
in +15V and -15V to pins 7 and 4, respectively and
 IMG_20170814_121131.jpgIMG_20170814_121139.jpgIMG_20170814_121758~2.jpg 
  13210   Tue Aug 15 13:32:38 2017 KiraUpdatePEMtemperature sensorTested to make sure that even when only
the AD586 was heated that there was no change
in the reading. I did so by placing the AD586
  
  1102   Thu Oct 30 20:39:47 2008 carynConfigurationPEMtemperature sensor We attached the temperature sensor box to
the MC1/MC3 chamber with a C-clamp. We connected
the temp sensor to a 2nd box with a short
  
  6731   Thu May 31 16:19:07 2012 yutaUpdateGreen Lockingtemperature setting for PSL doubling crystalI fixed the temperature control of the
oven for the PSL doubling crystal.
The PID settings were not good, and
  
  11131   Wed Mar 11 13:54:18 2015 SteveUpdateGeneraltemporaly storage in the east armGreen glass for aLIGO OMC shield is temporarly
stored in the inside of the Y-arm.
 greenG.jpgEastArm.jpg 
ELOG V3.1.3-