40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 335 of 344  Not logged in ELOG logo
ID Date Author Type Category Subjectdown Text Attachments
  3869   Fri Nov 5 15:20:18 2010 josephb, alexSummaryCDS40m computer slow down solvedProblem:
The 40m computers were responding
sluggishly yesterday, to the point of being
  
  3872   Fri Nov 5 21:49:12 2010 ranaSummaryCDS40m computer slow down solved


   
        
            
  
  3877   Sat Nov 6 16:13:14 2010 ranaSummaryCDS40m computer slow down solvedAs part of the effort to debug what was
happening with the slow computers, I disabled
the auto MEDM snapshots process that Yoichi/Kakeru
  
  3106   Wed Jun 23 15:15:53 2010 josephbSummaryComputers40m computer security issue from last night and this morningThe following is not 100% accurate, but
represents my understanding of the events
currently.  I'm trying to get a full
  
  6733   Thu May 31 17:47:25 2012 SureshOmnistructureGeneral40m Wireless NetworkMike Pedraza came by today to install a
new wireless network router configured for
the 40m lab network.  It has a 'secret'
 40m_Wifi.png 
  6741   Fri Jun 1 10:00:03 2012 steveOmnistructureGeneral40m Wireless Network

    

       
            
  
  3072   Sat Jun 12 19:41:04 2010 AlbertoUpdateLocking40m Upgrade Optickle ModelI wrote down the settings according to
which I tuned the optickle model of the 40m
Upgrade.
 optickleIFOworkingpoint.pdf 
  3074   Sun Jun 13 08:28:44 2010 valeraUpdateLocking40m Upgrade Optickle Model In my calculation of the digital
filters of the optical transfer functions
the carrier light is resonant in coupled
  
  3075   Mon Jun 14 07:57:07 2010 albertoUpdateLocking40m Upgrade Optickle Model

    
        
  
  3079   Tue Jun 15 21:28:44 2010 albertoUpdateLocking40m Upgrade Optickle Model


   
        
            
 allTransferFunctions_DARMoff_0.pdfallTransferFunctions_DARM2AS_10pmDARMoffset.pdfJan_DARM2AS.pdf 
  2044   Fri Oct 2 17:00:06 2009 AlbertoUpdateGeneral40m Update - Requirements on the 5x Frequency MultiplierHere's the gist of the requirements on
the 5x frequency multiplier for the upgrade
(see attachemnt - despite the preview down
 DesignOfTheMultiplier1-14-15.pdf 
  12220   Tue Jun 28 16:09:41 2016 PrafulUpdateGeneral40m Summary PagesSet up gwsumm on optimus and generated
summary pages from both L1 and C1 data. Still
a few manual steps need to be taken during
  
  6222   Wed Jan 25 15:04:41 2012 JenneBureaucracySAFETY40m SOS supplies moved off of cleanroom flow benchBob, Callum and Daphen noted that our keeping
a JDSU HeNe (max power <4mW) is against
somebody's SOP.  So I cleared everything
  
  6974   Fri Jul 13 15:49:38 2012 yutaBureaucracyGeneral40m Priority Action ItemsThese are all priority action items need
to be done before I come back (in mid-September).
  
  15323   Sat May 9 17:01:08 2020 YehonathanUpdateLoss Measurement40m Phase maps loss estimationI took the phase maps of the 40m X arm
mirrors and calculated what is the loss of
a gaussian beam due to a single bounce. I
 ITMX_Loss_Map.pdfETMX_Loss_Map.pdfITMX_Phase_Map_(nm).pdfETMX_Phase_Map_(nm).pdf 
  15329   Wed May 13 15:13:11 2020 YehonathanUpdateLoss Measurement40m Phase maps loss estimationKoji pointed out during the group meeting
that I should compensate for local tilt when
I move the beam around the mirror for calculating
 ITMX_Loss_Map.pdfETMX_Loss_Map.pdf 
  15332   Thu May 14 12:21:56 2020 YehonathanUpdateLoss Measurement40m Phase maps loss estimationI finished calculating the X Arm loss using
first-order perturbation theory. I will post
the details of the calculation later.
 ITMX_Loss_Map_Perturbation_Theory.pdfETMX_Loss_Map_Perturbation_Theory(1).pdf 
  15333   Thu May 14 19:00:43 2020 YehonathanUpdateLoss Measurement40m Phase maps loss estimationPerturbation theory:

The cavity modes 
  
  15338   Tue May 19 15:39:04 2020 YehonathanUpdateLoss Measurement40m Phase maps loss estimationI have a serious concern about this low
angle scattering analysis:

Phase maps perturb the spatial
 Mode_power_fraction1.pdf 
  3451   Fri Aug 20 17:46:30 2010 ranaUpdatePSL40m PSL Upgrade Layout v0.3http://lhocds.ligo-wa.caltech.edu:8000/40m/PSL/LayoutUpgrade
P-pol = purple
S-pol = red
  
  14366   Wed Dec 19 00:12:46 2018 gautamUpdateOMC40m OMC DCC nodeI made a node
to collect drawings/schematics for the 40m
OMC, added the length drive for now. We should
  
  8786   Fri Jun 28 16:19:06 2013 CharlesUpdateISS40m Noise Budget - Seismic Contribution I'm working on developing a full
noise budget for the 40m. To that end, I'll
use measurements from the GUR1 seismometer
 seismic_noise_6-28-13_raw.pngseismic_noise_6-28-13_raw.figseismic_noise_6-28-13_meters.pngseismic_noise_6-28-13_meters.fig 
  6668   Wed May 23 20:41:37 2012 SureshBureaucracyGeneral40m Meeting Action Items: Tip-tilts : cabling and electronics

    

       
            
  
  6520   Wed Apr 11 16:33:16 2012 JenneBureaucracyGeneral40m Meeting Action ItemsAction
Items from Last Week:
(non-existant)
  
  6597   Thu May 3 13:35:56 2012 JenneBureaucracyGeneral40m Meeting Action ItemsAction
Items:
IFO
  
  6636   Wed May 9 15:50:13 2012 JenneBureaucracyGeneral40m Meeting Action ItemsI'm combining the IFO check-up list (elog
6595) and last week's action items list
  
  6667   Wed May 23 13:57:11 2012 JenneBureaucracyGeneral40m Meeting Action ItemsPRIORITY
ITEMS:
Align Ygreen beam - 
  
  16015   Sat Apr 10 11:56:14 2021 JonUpdateCDS40m LSC simPlant modelSummary

Yesterday I resurrected
the 40m's LSC simPlant model, c1lsp.
 x1lsp_main.png 
  16021   Tue Apr 13 16:24:38 2021 Ian MacMillanUpdateCDS40m LSC simPlant modelAdded Matlab to the Docker machine. This
should help immensely with workflow as well
as keeping installed libraries consistent.
  
  16050   Mon Apr 19 13:15:20 2021 Ian MacMillanUpdateCDS40m LSC simPlant modelThe x1SUSsim model on the docker was made
in a more recent version of Simulink so I
updated Matlab (see
  
  16059   Wed Apr 21 10:03:01 2021 Ian MacMillanUpdateCDS40m LSC simPlant modelSo I am stuck on how to add the control
block to my model. I am trying to make it
as simple as possible with just a simple
 Overview.png 
  16061   Wed Apr 21 11:01:37 2021 RanaUpdateCDS40m LSC simPlant modelThe controller would be in the c1sus model,
and connects to the c1sup plant model. So
the controller doesn't go in the plant
  
  16081   Fri Apr 23 15:52:19 2021 Ian MacMillanUpdateCDS40m LSC simPlant modelI have attached the framework that I am
using for the full system. Plantframework.pdf
has the important aspects that I will be
 Plant_framework.pdfSimple_Plant.pdfControls.pdf 
  11433   Tue Jul 21 21:25:18 2015 Max IsiUpdateGeneral40m LDAS accountA shared LIGO Data Grid (LDG) account was
created for use by the 40m lab. The purpose
of this account is to provide access to the
  
  9571   Thu Jan 23 13:23:10 2014 SteveUpdateVAC40m IFO is at atmosphere

    

       
            
  
  6895   Fri Jun 29 13:11:31 2012 steveUpdateVAC40m IFO at atm The 4 hrs vent plot at 3 torr/min
rate.
Nitrogen was used from 1e-6 torr
 vent06292012.png40m@ATM.png 
  1998   Thu Sep 24 19:35:20 2009 ranaHowToPhotos40m Google accountI've created a 40m Google account. Please
post all the 40m related photos to this site.
If you don't already have it, download Picasa
  
  1213   Fri Jan 2 17:20:44 2009 ranaSummaryComputer Scripts / Programs40m GWINCI have made a '40m' directory in the iscmodeling
CVS tree which allows one to run a 40m version
of GWINC.
 bench40.pdf 
  6034   Tue Nov 29 07:45:56 2011 rana, joshSummaryComputer Scripts / Programs40m Daily News web pages As part of the initiative to
get a good daily summary page for aLIGO commissioning,
Josh is spearheading his
  
  7670   Mon Nov 5 13:28:15 2012 jamieUpdateGeneral40m DCC document treeLink to the new 40m
DCC Document Tree: E1200979
  
  15928   Wed Mar 17 09:05:01 2021 Paco, AnchalConfigurationComputers40m Control Room Changes
Switched positions of allegra and
donatella.
While doing so, the
hdmi cable previously used by donatella snapped.
  
  16027   Wed Apr 14 13:16:20 2021 AnchalConfigurationComputers40m Control Room Changes
I have confirmed that the old two
monitors' backlighting is not working.
One can see the impression of the display
  
  2824   Wed Apr 21 11:32:31 2010 josephbUpdateCDS40m CDS hardware update and software requestsThis is mostly a reminder to myself about
what I discussed with Jay and Alex this morning.
The big black IO chassis are "almost"
  
  13560   Fri Jan 19 15:22:19 2018 Udit KhandelwalSummaryGeneral40m CAD update 2018/01/1940m CAD Project


All parts will be now named
according to the numbering system in this
 Screenshot_3.png 
  6720   Wed May 30 22:04:13 2012 JenneBureaucracyGeneral40m Action Items.....including:
fix Q of Vio2 filter in SUS. - JENNE
Switch power source for beatnote
  
  6843   Thu Jun 21 02:57:16 2012 JenneBureaucracyGeneral40m Action ItemsPRIORITY
ITEMS:
  
  15456   Mon Jul 6 15:10:40 2020 JonSummaryBHD40m --> A+ BHD design analysisAs suggested last week, Hang and I have
reviewed the A+ BHD status
(DRD, CDD, and reviewers' comments) and
  
  8540   Tue May 7 17:43:51 2013 JamieUpdateComputers40MARS wireless network problemsI'm not sure what's going on today but
we're seeing ~80% packet loss on the 40MARS
wireless network.  This is obviously
  
  8541   Tue May 7 18:16:37 2013 JamieUpdateComputers40MARS wireless network problemsHere's an example of the total horribleness
of what's happening right now:

controls@rossa:~ 0$ ping 192.168.113.222
PING
  
  8762   Thu Jun 27 05:44:51 2013 ranaUpdate 40MARS wireless network problems

    

       
            
  
ELOG V3.1.3-