  6643   Mon May 14 08:49:47 2012 steveUpdateSUSETMY damping restoredETMY sus damping restored.   
  6644   Tue May 15 08:44:55 2012 steveUpdateSUSETMX damping restoredETMX sus damping restored  ETMX_ETMYvar.png 
  6647   Wed May 16 14:06:49 2012 steveUpdateSUSTemperature rulesGuralp 1  is on the south side of
IOO chamber
 temprules.png 
  6648   Thu May 17 15:31:22 2012 steveUpdateGeneralbeam trap posts & clamps for vacuum Aluminum posts and SS clamps for
green glass traps in vacuum will be out of
the shops by June 6, 2012 the latest
 05161201.PDF05151201.PDF 
  6649   Fri May 18 11:19:17 2012 steveUpdateSUSETMY oplev laser is dead 
 The typical sign of a dying
gas laser is that it glows for a few minutes
  
  6650   Fri May 18 15:25:15 2012 steveUpdateSUSAR coated lens swapped in at ETMX oplev

    

       
            
 ETMXoplevlensAR.png 
  6652   Mon May 21 07:45:39 2012 steveUpdateIOOPMC lockedI locked the PMC and the MC followed instantly.  pmclocked.png 
  6656   Tue May 22 08:03:01 2012 steveUpdateSUSETMY oplev gets new laser

    

       
            
  
  6665   Wed May 23 10:40:21 2012 steveUpdateIOOPMC locked

    

       
            
 pmc.png 
  6666   Wed May 23 11:30:39 2012 steveUpdatePEMnew emergency back up lights installedNew self checking emergency back
up lights were installed at 13 locations
in the 40m lab.
 IMG_1217.JPG 
  6672   Thu May 24 10:10:04 2012 steveUpdateIOOPMC locked The PMC  behavior is not changed.
 
 pmc4d.png 
  6678   Thu May 24 16:39:47 2012 steveUpdateGeneralsteve's webpage example3 strip charts monitoring on 24 hours time
scale: Vac,  PSL-IFO,  SUS and
10 channel video monitoring inside - outside 
 05241201.PDF 
  6700   Tue May 29 10:08:21 2012 steveUpdateIOOcentered IOO monitoring qpdsIOO Angle & IOO Position QPDs centered.  40dtrendIOO.pngIOOcentered.png 
  6706   Tue May 29 15:55:22 2012 steveUpdateSUSETMY oplev spot size reduced

    

       
            
 ETMYoplev.jpgIMG_1243.JPG 
  6729   Thu May 31 11:02:14 2012 steveUpdateLockingETMX 1064 trans camera

    

       
            
  
  6738   Fri Jun 1 08:01:46 2012 steveUpdateComputersc1sus and c1iscex are down

    

       
            
 compdown.png 
  6739   Fri Jun 1 08:17:47 2012 steveUpdateIOOPMC trends

    

       
            
 PMC400d.pngPMC1200d.png 
  6741   Fri Jun 1 10:00:03 2012 steveOmnistructureGeneral40m Wireless Network

    

       
            
  
  6744   Fri Jun 1 18:07:32 2012 steveUpdateSUSOplevs servo values

    

       
            
  
  6752   Tue Jun 5 09:32:12 2012 steveUpdateSUSPRM oscillation What not to do:
The PRM oplev servo was left on and
it was driving this oscillation overnight.
 PRMosc.png 
  6753   Tue Jun 5 09:44:14 2012 steveUpdatePSLref cavity ion pump must be pumped

    

       
            
  
  6754   Tue Jun 5 14:17:14 2012 steveUpdatePEMair cond maintenance  
 Air conditioning maintenance
is scheduled for tomorrow from 8 to 11am
  
  6764   Wed Jun 6 09:27:09 2012 steveUpdateSUSPRM damping restored

    

       
            
 PRMwhat.png 
  6765   Wed Jun 6 14:17:56 2012 steveUpdateComputersiMac orderedRana, Steve,
 
  
  6766   Wed Jun 6 14:36:58 2012 steveUpdateSUSETMY oplev work finished

    

       
            
  
  6781   Thu Jun 7 08:12:20 2012 steveUpdateSUSPRM is still oscillating

    

       
            
 PRMoscil.png 
  6782   Thu Jun 7 09:52:05 2012 steveUpdatePEMair cond maintenance

    

       
            
 PEM800d.png 
  6790   Fri Jun 8 15:24:08 2012 steveUpdateVACRGA scan at day 276 and pressure plots

    

       
            
 40m71pdM276d.pngpd71m276d.pngpd71d276.png 
  6791   Mon Jun 11 09:37:16 2012 steveUpdateIOOPMC locked

    

       
            
 PMClocked.png 
  6804   Tue Jun 12 16:33:32 2012 steveUpdateSUSPRM oplevs servo ON for confirmation


   
        
            
  
  6805   Tue Jun 12 17:04:55 2012 steveUpdateSUSPRM oplevs servo is still bad


   
        
            
 PRMolvstillosc.png 
  6814   Wed Jun 13 11:19:05 2012 steveUpdateSUSIDC receptacles clampedThe MC_ IDC 64 pin cables from sat. amplifiers
to junction-interface-board towards 
whitening - dewhitening at the back of rack
 IMG_1341.JPG 
  6844   Thu Jun 21 09:01:18 2012 steveUpdateSTACISthe resurrection of STACIS -surfThere is a small wood cabinet under the
south end flow bench, labeled STACIS.
Unit is complete with extension cards
 IMG_1364.JPG 
  6845   Thu Jun 21 09:10:08 2012 steveUpdatePEMflow bench must be running all timesThe south end flow bench HEPA filter should
be run all times. You can turn it off for
a measurement or two but remember we are
  
  6848   Thu Jun 21 15:00:55 2012 steveUpdateSAFETYSURFs 2012 safety trainingMasha, Eric, Yaakov, Liz and Sasha received
40m specific basic safety training.
 surfs2012.JPG 
  6860   Sat Jun 23 18:44:15 2012 steveUpdateGeneralpower surge has no effect on the labI was notified by CIT Utilities that there
was a power surge or short power outage this
after noon.
  
  6864   Mon Jun 25 08:21:40 2012 steveUpdateGeneralAC power disturbance on Sat

    

       
            
 powerdisturbed.png 
  6894   Fri Jun 29 11:02:00 2012 steveUpdateVACthe vent is at 500 torr

    

       
            
 sussum.pngpzt.png 
  6895   Fri Jun 29 13:11:31 2012 steveUpdateVAC40m IFO at atm The 4 hrs vent plot at 3 torr/min
rate.
Nitrogen was used from 1e-6 torr
 vent06292012.png40m@ATM.png 
  6898   Sat Jun 30 18:31:38 2012 steveUpdateIOOinput telescope beam clipping on Faraday  We could set up a simple pick 
off after the Faraday  and bring it 
out the north window of IOO chamber. No monitor
  
  6906   Tue Jul 3 17:23:50 2012 steveUpdateVACpumpdown completedVacuum Normal State is reached in 9 hours. 
CC1 =  2e-5 Torr
Aux dry pump #3 is still running. 
 pd72.pngpd72vacnormal.pngpd72at9hrs.png 
  6927   Fri Jul 6 08:38:04 2012 steveUpdateComputerstime outWhy do we have these timing blanks?  timingblanks.png 
  6929   Fri Jul 6 09:27:40 2012 steveUpdateVAC4 days at atm I'm looking for some movement indicators
of the vent-pump down events.
 
 vent_moves.png 
  6930   Fri Jul 6 09:52:35 2012 steveUpdateVACpump down hick up I can not understand what really
happened here with CC1 gauge or there was
really a pressure glitch.
 d3wFireworks.pngpdhickup.png 
  6959   Wed Jul 11 11:18:21 2012 steveUpdatePEMmore seismic noise next week 
   The fabricators
of the big flume in the CES lab have begun
 testing the sediment feed system which is
  
  6970   Thu Jul 12 16:27:04 2012 steveUpdateVACdrypump changedTP2  dry_pump was changed at intake
pressure 982 mTorr at 84,889 hrs  This
seal hold up for one year.
  
  7044   Fri Jul 27 14:28:36 2012 steveUpdateVACcold cathode gaugesOur cold
cathode 423 gauges are 10 years old.
They get insulated by age and show no ionization
 cc_gauges.png 
  7047   Mon Jul 30 09:00:18 2012 steveUpdatePSLPMC is still not fixedThe PMC was locking right the way, but
it's transmission would not go up. 
Finally I get it back up by moving the "sticky"
 pmcA.pngpmcB.png 
  7051   Mon Jul 30 15:49:16 2012 steveUpdateVACcc1 switched

    

       
            
 cc1changedfVtH.png 
  7056   Tue Jul 31 08:01:22 2012 steveUpdateVACcc1 switched

    

       
            
 cc1h1d.png 