6432
|
Wed Mar 21 10:31:28 2012 |
steve | Update | SAFETY | AC power to ETMY turned off |
ETMY sus damping was disabled. Green locking laser and associated electronics turned off. Computers and power supplies turned off at rack 1Y4
The electricians picking up ac power from 1Y4 manual disconnect box and installing conduit line to ISCT-ETMY east end optical table.
There will be no more daisy chaining this way. |
6433
|
Wed Mar 21 11:32:47 2012 |
steve | Update | SAFETY | AC power to ETMX turned off |
Quote: |
ETMY sus damping was disabled. Green locking laser and associated electronics turned off. Computers and power supplies turned off at rack 1Y4
The electricians picking up ac power from 1Y4 manual disconnect box and installing conduit line to ISCT-ETMY east end optical table.
There will be no more daisy chaining this way.
|
The power is back on at ETMY . c1iscey has not been restarted.
Now I'm turning ac power off at ETMX for the same job to be done. |
6434
|
Wed Mar 21 19:12:27 2012 |
steve | Update | Computers | AC power back on both ends |
Quote: |
Quote: |
ETMY sus damping was disabled. Green locking laser and associated electronics turned off. Computers and power supplies turned off at rack 1Y4
The electricians picking up ac power from 1Y4 manual disconnect box and installing conduit line to ISCT-ETMY east end optical table.
There will be no more daisy chaining this way.
|
The power is back on at ETMY . c1iscey has not been restarted.
Now I'm turning ac power off at ETMX for the same job to be done.
|
The power was turned back on at 4pm It took some time for Suresh to restart the computers. We have damping but things are not perfect yet. Auto BURTH did not work well. |
6435
|
Thu Mar 22 08:14:21 2012 |
steve | Update | Green Locking | dichroic mirror quotes with large wedge |
Quote: |
Dichroic mirror quotes are in the wiki.
ATF is pricy.
We got a good price from Laseroptik, but the wedges are 5 arcminutes. The fused silica grade is 0F, meaning the homogeneity is 5 ppm instead of 1ppm. I requested an other large wedge quote on the substrates.We may have to get substrates from somebody else and ship it to Germany
MLT quote is outrageously high
REO is not interested in this low volume job.
|
The Laseroptik quote is here.The 2 degrees wedge cost is $40 on each optics! See wiki |
6469
|
Fri Mar 30 08:58:37 2012 |
steve | Update | SAFETY | Safety glasses checked |
Bob cleaned all safety glasses in 10 % Liquinox soap in water solution first. The transmittance of glasses were checked at 100 mW 1064 nm S polarization, beam diameter 0.5 mm at 0-20 deg incident.
Coherent FieldMate power meter measured T= < 1 mW of all glasses. |
6470
|
Fri Mar 30 09:37:13 2012 |
steve | Update | SAFETY | safety audit 2012 CORRECTIONS |
Quote: |
Correction list by visiting safety committee, Haick Issaian is not shown:
1, update laser, crane operator list and post it
2, check fire extinguishers monthly, date and initials must be on the tags
3, move drinking water tower so it does not block fire extinguisher
4, post updated crane doc at cranes
5, post present phone lists at IFO room phones
6, emergency laser shutoff at the south end must be mounted without C-clamp
7, use heavy cable tie to insure position of mag-fan on cabinet top
Additional to do list:
a, safety glasses to be cleaned
b, let the electrical shop fix Rack-AC power to optical tables at the ends
c, measure transmission of laser safety glasses
d, update IFO outside door info signs
e, update laser inventory and post it
f, schedule annual crane inspection and renew maintenance contract
g, PSL enclosure inner shelf needs a good clean up so it is earthquake safe
|
Completed with the exception of d and g |
6472
|
Fri Mar 30 10:24:14 2012 |
steve | Update | SUS | new OSEM locking plunger |
Quote: |
Quote: |
Our existing 300 series SS plungers from McMastercar #8476A43 are silver plated as Atm2 shows.
Problems: 1, they become magnetized after years being close to the magnets
2, they oxidize by time so it is hard to turn them
I looked around to replace them.
Titanium body, nose and beryllium copper spring. None magnetic for UHV enviorment.
Can be made in 7 weeks at an UNREASONABLE $169.00 ea at quantity of 50
|
In order to get a better price from Vlier's Tom Chen I changed Ti body back to SS304L-siver plated and music wire spring. The price is still ~$120 ea. at quantity 50
I will talk to Mike G about modifying the McMaster plunger with a hex nut.
|
Conclusion: There is no need to silver plate the SS plunger at the torque level we hold the OSEMs
Mike Gerfen will be done with 50 pieces by April 4 and he will give them to Bob for cleaning. They should be cleaned and baked in a jig so the springs would be compressed for better venting. |
6473
|
Fri Mar 30 17:37:09 2012 |
steve | Update | General | cutting green welding glass for beam dumps |
Quote: |
Schott, green welding glass, shade 14, 3 mm thick was measured in the beam path of 1.2W, S polarization of 1064nm at ~1 mm diameter size as MC reflected path.
Absorption 95%, R 5% at incident angle 25-50 degrees. It looks like the perfect material for beam trap.
|
The CIT Chemistry Glass Shop cuts turned out to be sloppy using diamond disc blade cutter.
East coast Precision Glass & Optics offered scribed cut and polished side. Their quote price was high and time consuming.
The GLASS HOUSE shop in Pasadena 626 / 796-9151 on Walnut did a good and cheap job. Oscar the cutter will finish the rest of the cutting by next Friday, April 6
He used scribed cutting technic and his 1" x 0.5" pieces are good. Bob will pick up them up. |
6558
|
Tue Apr 24 09:58:37 2012 |
steve | Update | PEM | earthquake 3.9 magnitude |
Local eq shakes the lab |
6559
|
Tue Apr 24 11:27:51 2012 |
steve | Update | PEM | new chairs |
We received 6 new chairs stools for the work benches that have 36" heights.
The control room east side and general office desks require 18" seat height. The new chairs stools have minimum seat heights 26"
Please label chairs that we are getting rid of.

|
6571
|
Thu Apr 26 09:22:17 2012 |
steve | Update | | under the east end optical table |
Quote: |
I added an U channel based bottom shelf at the south end today.
|
I'm working on similar shelf at ETMY. Precondition: NPRO in bypass mode, heater for doubling in bypass........since power outage? Optical level servo turned off.......
U-channel based shelf in place. Oplev servo is back on at 11:15am The table may moved. The oplev return is missing the quad by a few milimeter. |
6577
|
Fri Apr 27 08:11:19 2012 |
steve | Update | CDS | c1ioo condition |
|
6643
|
Mon May 14 08:49:47 2012 |
steve | Update | SUS | ETMY damping restored |
ETMY sus damping restored. |
6644
|
Tue May 15 08:44:55 2012 |
steve | Update | SUS | ETMX damping restored |
ETMX sus damping restored |
6647
|
Wed May 16 14:06:49 2012 |
steve | Update | SUS | Temperature rules |
Guralp 1 is on the south side of IOO chamber |
6648
|
Thu May 17 15:31:22 2012 |
steve | Update | General | beam trap posts & clamps for vacuum |
Aluminum posts and SS clamps for green glass traps in vacuum will be out of the shops by June 6, 2012 the latest
|
6649
|
Fri May 18 11:19:17 2012 |
steve | Update | SUS | ETMY oplev laser is dead |
The typical sign of a dying gas laser is that it glows for a few minutes only. The power supplies are fine.
Two new JDS - Uniphase 1103P lasers ( NT64-104 ) arriving on Monday, May 21 |
6650
|
Fri May 18 15:25:15 2012 |
steve | Update | SUS | AR coated lens swapped in at ETMX oplev |
Quote: |
ETMX oplev had 6 mm diameter beam on the qpd. I relayed the beam path with 2 lenses to get back 3 mm beam on the qpd
BRC 037 -100 Bi _concave lens and PCX 25 200 VIS do the job. Unfortunately the concave lens has the AR 1064.
|
The uncoated bi-concave lens was replaced by AR coated one: KBC 037 -100 AR.14 resulting 35% count increase on qpd |
6652
|
Mon May 21 07:45:39 2012 |
steve | Update | IOO | PMC locked |
I locked the PMC and the MC followed instantly. |
6656
|
Tue May 22 08:03:01 2012 |
steve | Update | SUS | ETMY oplev gets new laser |
Quote: |
The typical sign of a dying gas laser is that it glows for a few minutes only. The power supplies are fine.
Two new JDS - Uniphase 1103P lasers ( NT64-104 ) arriving on Monday, May 21
|
Yesterday I swapped in new He/Ne laser with output power 3.5 mW The return spot on qpd is large ~6mm in diameter and 20,500 counts
The spot size reduction require similar layout as ETMX oplev. |
6665
|
Wed May 23 10:40:21 2012 |
steve | Update | IOO | PMC locked |
Quote: |
I locked the PMC and the MC followed instantly.
|
|
6666
|
Wed May 23 11:30:39 2012 |
steve | Update | PEM | new emergency back up lights installed |
New self checking emergency back up lights were installed at 13 locations in the 40m lab. |
6672
|
Thu May 24 10:10:04 2012 |
steve | Update | IOO | PMC locked |
The PMC behavior is not changed.
|
6678
|
Thu May 24 16:39:47 2012 |
steve | Update | General | steve's webpage example |
3 strip charts monitoring on 24 hours time scale: Vac, PSL-IFO, SUS and 10 channel video monitoring inside - outside of 40m lab |
6700
|
Tue May 29 10:08:21 2012 |
steve | Update | IOO | centered IOO monitoring qpds |
IOO Angle & IOO Position QPDs centered. |
6706
|
Tue May 29 15:55:22 2012 |
steve | Update | SUS | ETMY oplev spot size reduced |
Quote: |
Quote: |
The typical sign of a dying gas laser is that it glows for a few minutes only. The power supplies are fine.
Two new JDS - Uniphase 1103P lasers ( NT64-104 ) arriving on Monday, May 21
|
Yesterday I swapped in new He/Ne laser with output power 3.5 mW The return spot on qpd is large ~6mm in diameter and 20,500 counts
The spot size reduction require similar layout as ETMX oplev.
|
The oplev path is relayed and the spot size on the qpd is reduced. I still have to clean up and replace "Miki Mouse" lens holder.
There was no IP-ANG coming out of the chamber at this time! |
6729
|
Thu May 31 11:02:14 2012 |
steve | Update | Locking | ETMX 1064 trans camera |
Quote: |
Quote: |
...will be helpful for acquiring lock after the vent. We should install a camera at ETMX.
|
Do that.
|
Jenne and Steve
Sony CCD in place needs alignment and ND filter |
6738
|
Fri Jun 1 08:01:46 2012 |
steve | Update | Computers | c1sus and c1iscex are down |
Quote: |
Something bad happened to c1sus and c1iscex ~20 min ago. They both have "0x2bad" 's. I restarted the daqd on the framebuilder, and then rebooted c1sus, and nothing changed. The SUS screens are all zeros (the gains seem to be set correctly, but all of the signals are 0's).
If it's not fixed when I get in tomorrow, I'll keep poking at it to make it better.
|
|
6739
|
Fri Jun 1 08:17:47 2012 |
steve | Update | IOO | PMC trends |
Quote: |
IOO Angle & IOO Position QPDs centered.
|
PMC trend of 400 and 1200 days
The Innolight 2W based PSL- IOO was implemented in the ~ summer of 2010 |
6741
|
Fri Jun 1 10:00:03 2012 |
steve | Omnistructure | General | 40m Wireless Network |
Quote: |
Mike Pedraza came by today to install a new wireless network router configured for the 40m lab network. It has a 'secret' SSID i.e. not meant for public use outside the lab. You can look up the password and network name on the rack. Pictures below show the location of the labels.

|
Mike P swapped in a new network router Linksys E1000 |
6744
|
Fri Jun 1 18:07:32 2012 |
steve | Update | SUS | Oplevs servo values |
Quote: |
For some reason the state of the oplevs is completely different for almost every suspension. They have different sets of filters in the bank, and different filters engaged. wtf? How did this happen? Is this correct? Do we expect that the state of the oplevs should be different on all the different suspensions? I wouldn't have thought so.
I discovered this because the PRM is unstable with the oplevs engaged. I don't think it was yesterday. Is something hidden changing the oplev settings?
|
As of February 23, 2012 when oplev PIT and YAW transfer functions were taken
OPLEV SERVO |
300^ 2:0 |
BR |
ELP |
RLP |
RES |
GAIN |
QPD counts |
OD mm |
|
|
|
|
|
|
|
|
|
|
|
ETMY pit |
300^ 2:0 |
BR |
35 |
80 |
0.5 |
-1.5 |
15,500 |
~1 |
|
ETMY yaw |
300^ 2:0 |
BR |
35 |
80 |
0.6 |
-1.0 |
|
|
|
ETMX pit |
300^ 2:0 |
BR |
35 |
80 |
0.5 |
0.5 |
1,500 |
~1.5 |
|
ETMX yaw |
300^ 2:0 |
BR |
35 |
80 |
0.6 |
1.0 |
|
|
|
ITMY pit |
300^ 2:0 |
BR |
|
80 |
|
2.0 |
15,000 |
~2.5 |
|
ITMY yaw |
300^ 2:0 |
BR |
|
80 |
|
-4.0 |
|
|
|
ITMX pit |
300^ 2:0 |
BR |
|
80 |
|
1.0 |
1,350 |
~1.5 |
|
ITMX yaw |
300^ 2:0 |
BR |
|
80 |
|
-2.0 |
|
|
|
BS pit |
300^ 2:0 |
BR |
50 |
|
|
0.5 |
3,500 |
~1 |
|
BS yaw |
300^ 2:0 |
|
50 |
|
3.3 |
-1.0 |
|
|
|
PRM pit |
300^ 2:0 |
BR |
|
|
3.3 |
1.0 |
4,000 |
~2 |
|
PRM yaw |
300^ 2:0 |
BR |
35 |
|
3.3, 4 |
-0.5 |
|
|
|
SRM pit |
300^ 2:0 |
BR |
40 |
|
|
-2.0 |
2,600 |
~2.5 |
|
SRM yaw |
300^ 2:0 |
BR |
40 |
|
|
2.0 |
|
|
|
|
6752
|
Tue Jun 5 09:32:12 2012 |
steve | Update | SUS | PRM oscillation |
What not to do:
The PRM oplev servo was left on and it was driving this oscillation overnight. |
6753
|
Tue Jun 5 09:44:14 2012 |
steve | Update | PSL | ref cavity ion pump must be pumped |
Quote: |
The ref cavity ion pump was running at 7.7kV instead of 5kV
This Digitel SPC-1 20 l/s ion pump should be running at 5kV
|
I noticed that the ion pump was turned off.
It was turned ON. It showed 0.00 microA at 5kV The current display is not sensitive enough. There must be some small outgassing or leak. It adds up if we stop pumping.
We want to keep the reference cavity in pristine condition. It required the ion pump running all times. |
6754
|
Tue Jun 5 14:17:14 2012 |
steve | Update | PEM | air cond maintenance |
Air conditioning maintenance is scheduled for tomorrow from 8 to 11am |
6764
|
Wed Jun 6 09:27:09 2012 |
steve | Update | SUS | PRM damping restored |
Quote: |
What not to do:
The PRM oplev servo was left on and it was driving this oscillation overnight.
|
Oplev servo turned off and sus damping restored. What is kicking up the PRM? |
6765
|
Wed Jun 6 14:17:56 2012 |
steve | Update | Computers | iMac ordered |
Rana, Steve,
- Part number: Z0M6
Configuration
- 2.7GHz Quad-Core Intel Core i5
- 16GB 1333MHz DDR3 SDRAM - 4x4GB
- 1TB Serial ATA Drive
- AMD Radeon HD 6770M 512MB GDDR5
- Apple Mouse
- Apple Keyboard with Numeric Keypad (English) & User's Guide
- Accessory Kit
|
6766
|
Wed Jun 6 14:36:58 2012 |
steve | Update | SUS | ETMY oplev work finished |
Quote: |
Quote: |
Quote: |
The typical sign of a dying gas laser is that it glows for a few minutes only. The power supplies are fine.
Two new JDS - Uniphase 1103P lasers ( NT64-104 ) arriving on Monday, May 21
|
Yesterday I swapped in new He/Ne laser with output power 3.5 mW The return spot on qpd is large ~6mm in diameter and 20,500 counts
The spot size reduction require similar layout as ETMX oplev.
|
The oplev path is relayed and the spot size on the qpd is reduced. I still have to clean up and replace "Miki Mouse" lens holder.
|
Late entry for Monday morning June 4, 2012
Cables were stress relieved. Cable entry - exit ports enlarged. Air gaps were minimized. |
6781
|
Thu Jun 7 08:12:20 2012 |
steve | Update | SUS | PRM is still oscillating |
Quote: |
Quote: |
What not to do:
The PRM oplev servo was left on and it was driving this oscillation overnight.
|
Oplev servo turned off and sus damping restored. What is kicking up the PRM?
|
The PRM oscillation stopped by turnig off oplev servo.
Do not turn Oplev Servo on when PRM is missaligned !
|
6782
|
Thu Jun 7 09:52:05 2012 |
steve | Update | PEM | air cond maintenance |
Quote: |
Air conditioning maintenance is scheduled for tomorrow from 8 to 11am
|
Jeff checked and replaced filters as needed. Job completed this morning. |
6790
|
Fri Jun 8 15:24:08 2012 |
steve | Update | VAC | RGA scan at day 276 and pressure plots |
Quote: |
We tried not to open chambers above 10,000 particles of 0.5 micron cf/min
New items going in: 2 rasor beam traps, 5 badly oxidized old silver plated setscrew with spring loaded tips......to be replaced in the future, viton tips for eq screws....some are lose, gold plated allen wrench installed at ITMX bottom, reglued magnet on ITMX
Bad hardware things found: nylon ball "locking elements" on OSEM locking set screws with screwdriver slot, lose 1064 nm filter on OSEM pd
|
40m - pumpdown 71- maglev pumping speed - at day 276........all normal |
6791
|
Mon Jun 11 09:37:16 2012 |
steve | Update | IOO | PMC locked |
Quote: |
Quote: |
IOO Angle & IOO Position QPDs centered.
|
PMC trend of 400 and 1200 days
The Innolight 2W based PSL- IOO was implemented in the ~ summer of 2010
|
The PMC was locked and the MC followed intantly |
6804
|
Tue Jun 12 16:33:32 2012 |
steve | Update | SUS | PRM oplevs servo ON for confirmation |
Quote: |
Yuta claims he fixed the PRM oplev by centering it the other day, but no one has left it on and watched it for a long while, to make sure it's okay. We watched it now for ~2 min, and it was good, but we're leaving the oplevs off anyway for the night. Tomorrow we should restore PRM (it's currently restored), turn on the oplevs, and let it sit to make sure it doesn't go crazy.
|
PRM oplev servo was turned on with PITgain 0.5 and YAWgain -0.7
Note: gain settings were PIT 1.0 and YAW --0.5 on Jun 1, 2012 that I measured Feb 23, 2012 |
6805
|
Tue Jun 12 17:04:55 2012 |
steve | Update | SUS | PRM oplevs servo is still bad |
Quote: |
Quote: |
Yuta claims he fixed the PRM oplev by centering it the other day, but no one has left it on and watched it for a long while, to make sure it's okay. We watched it now for ~2 min, and it was good, but we're leaving the oplevs off anyway for the night. Tomorrow we should restore PRM (it's currently restored), turn on the oplevs, and let it sit to make sure it doesn't go crazy.
|
PRM oplev servo was turned on with PITgain 0.5 and YAWgain -0.7
Note: gain settings were PIT 1.0 and YAW --0.5 on Jun 1, 2012 that I measured Feb 23, 2012
|
It is still oscillating. Gains turned down to zero. |
6814
|
Wed Jun 13 11:19:05 2012 |
steve | Update | SUS | IDC receptacles clamped |
The MC_ IDC 64 pin cables from sat. amplifiers to junction-interface-board towards whitening - dewhitening at the back of rack 1 X 5 are finally clamped with
All other sus cables of the same kind have the correct short latch arm to lock them in for reliable contact. |
6844
|
Thu Jun 21 09:01:18 2012 |
steve | Update | STACIS | the resurrection of STACIS -surf |
There is a small wood cabinet under the south end flow bench, labeled STACIS.
Unit is complete with extension cards and cables. |
6845
|
Thu Jun 21 09:10:08 2012 |
steve | Update | PEM | flow bench must be running all times |
The south end flow bench HEPA filter should be run all times. You can turn it off for a measurement or two but remember we are storing clean optics there.
The zero count bench will reach room particle count ~ 10,000 in one minute. |
6848
|
Thu Jun 21 15:00:55 2012 |
steve | Update | SAFETY | SURFs 2012 safety training |
Masha, Eric, Yaakov, Liz and Sasha received 40m specific basic safety training. |
6860
|
Sat Jun 23 18:44:15 2012 |
steve | Update | General | power surge has no effect on the lab |
I was notified by CIT Utilities that there was a power surge or short power outage this after noon.
Lab conditions are normal: c1ioo is down. The south arm AC was off......I turned it back on. |
6864
|
Mon Jun 25 08:21:40 2012 |
steve | Update | General | AC power disturbance on Sat |
Quote: |
I was notified by CIT Utilities that there was a power surge or short power outage this after noon.
Lab conditions are normal: c1ioo is down. The south arm AC was off......I turned it back on.
|
CALIFORNIA INSTITUTE OF TECHNOLOGY
FACILITIES MANAGEMENT
UTILITY & SERVICE INTERRUPTION
**PLEASE POST**
Building: CAMPUS
Date: Saturday, June 23, 2012
Time: 3:46 P.M.
Interruption: Electrical Power Disturbance
Contact: Tom Brennan, x-625-395-4984
*The City of Pasadena Water & Power Department had a 34,000-volt line event on Saturday June 23 at 3:46 p.m. This caused a city wide disturbance on the power grid. The Campus did not lose electrical power. However, the disturbance may have affected sensitive electronic equipment.
(If there is a problem with this Interruption, please notify the Service Center X-4717 or the above Contact as soon as possible.
If no response is received we will proceed with the interruption.)
Jerry Thompson,
Interim Director of Campus Operations & Maintenance
|
6894
|
Fri Jun 29 11:02:00 2012 |
steve | Update | VAC | the vent is at 500 torr |
Steve, Yuta and Jamie
Jam nuts were checked and oplev servos were turned off. Sus summery is below with strain gauge values. Are the strain gauge values have any meaning when the PZT contorrels are off?????????????????? |