ID |
Date |
Author |
Type |
Category |
Subject |
9304
|
Mon Oct 28 14:24:01 2013 |
Masayuki | Update | LSC | 'scope and spectrum analyser for REFL165 |
I connected the 'scope between REFL165 output and demod board input. I split the signal from coupler using the splitter (Mini-Circuits ZFSC-2-5). One signal is going to 'scope CH1 and the other is going to spectrum analyzer. I connected the 'scope to 40MARS. The IP adress is 192.168.113.25. I connected that by cabling from 1X2.
|
4642
|
Thu May 5 15:26:52 2011 |
Leo Singer | Configuration | Computers | 'glue' installed on some control room computers |
I installed 'glue' on Rossa, Allegra, and Rosalba. This is a Python module that includes a facility for LIGO_LW XML files. Oddly, I couldn't find the glue package on Pianosa. |
8011
|
Wed Feb 6 15:11:21 2013 |
Jenne | Update | Electronics | "Temporary" power supply situation |
[Jenne, Yuta, Rana, Steve, Manasa]
We have taken stock of the lab "temporary" power supply situation, and things look much better.
This morning, I removed 2 unused power supplies and a function generator from the PSL table - these had been used for MC ringdown things.
I also removed the non-connected cables that had been used for the RAMMON setup, and the EOM temperature controller circuit.
This afternoon, Yuta removed the 2 HV power supplies that were used to keep PZT2 working near the end of its life. Since we now have the active TTs, these have been turned off for a while, and just needed to be removed.
Manasa removed the power supply under the POP/POX table that was powering the amplifier for POP22. If we are going to continue using a Thorlabs PD for POP22, then we need to make a twisted pair of wires (~20 feet) to get power from 1X1. If we are going to (finally) install a gold RF PD, then that will not be necessary.
I removed the power supply sitting near the bottom of the LSC rack, for another amplifier for POP22 (with minicircuits filters attached). Again, if we get a gold RF PD, we can remove the filters and amplifier. If not, we can use the existing twisted pair of wires, and plug them into the rack rather than a power supply.
The power supply under the NE corner of the PSL table was no longer in use. It was most recently used for amplifiers for the green beat PDs, as Yuta mentioned in elog 6862, those were moved over to 1X2. In elog 8008 I mentioned that Yuta and I moved those amplifiers over to rack power.
The HV supply, the function generator and the OSA controllers that were on top of the short OMC rack next to the AS table have all been removed. We need to come up with a better place for the OSAs, since we need to re-install them. The power supply and the function generator (which was used just for a voltage offset) were formerly used for the output steering PZTs, but lately we have just been using those mirrors as fixed mirrors, since we don't need to steer into the OMC. Some day, we will replace those mirrors with the output steering active tip tilts, and re-commission the OMC....someday.
The power supply for the amplifier set (that goes with the set of minicircuits filters) for the RAMMON PD (which took light from the IPPOS path) has been removed. If we determine that we need RAMMON back, we will have to make a twisted pair to power those amplifiers.
SUMMARY:
* If we don't install a gold RF PD for POP22, we need a 20ft twisted pair for +15/GND.
* Also, if we don't install a gold RF PD for POP22, we need to plug the amplifier at the LSC rack into the rack power (twisted pair already exists).
* If we need RAMMON back, we will need a twisted pair to power those amplifiers.
* All other power supplies have been removed, and put away. We currently have 0 "temporary" power supplies in use in the lab! |
1015
|
Wed Oct 1 12:05:58 2008 |
Alberto | Configuration | Computers | "StochMon" added to the Alarm Handler |
John, Alberto,
we added the four channels of the RF Amplitude Monitor (aka StochMon) to the Alarm HAndler. First we modified the 40m.alh file just copying some lines and switching the name of the channels to the ones we wanted. Than we also added a few lines to the database file ioo.db in order to define the alrm levels. So far I used just test values for the thresholds of green, yellow and red states and need to update to some reasonable ones. To do that I need to calibrate those EPICS channels. I have the old data saved and I'm now trying to figure out how to properly change the database file. |
1016
|
Wed Oct 1 12:09:25 2008 |
Alberto | Configuration | Computers | "StochMon" added to the Alarm Handler |
Quote: | John, Alberto,
we added the four channels of the RF Amplitude Monitor (aka StochMon) to the Alarm HAndler. So far I used just test values for the thresholds of green, yellow and red states and need to update to some reasonable ones. To do that I need to calibrate those EPICS channels. I have the old data saved and I'm now trying to figure out how to properly change the database file. |
John, Yoichi, Alberto
We restarted the C1iool0 computer both directly by the main key and remotely via telnet. We had to do it a couple of times and in one occasion the computer didn't restart properly and had connection problem with the newtowrk. We had to call Alex that did just the same thing, but used the CTRL+X command to reboot. It worked and the Alarm Handler now includes the StochMon. |
8202
|
Thu Feb 28 14:51:43 2013 |
Jenne | Update | PEM | "Rock Monster" causing low frequency noise |
Manasa and I have been wondering why the low frequency seismic noise has been different in the last few days/weeks. I went over to visit the Rock Monster, a.k.a. the Earth Surface Dynamics Laboratory next door, and the grad student turned it up for me (increased water flow significantly) for a few minutes. Then I came back to look at the BLRMS, and you can see the low frequency increase a few minutes ago, when he turned it up on high. He said that they run it on low almost all the time, 9am-5pm ish, and on high for an hour or so at a time periodically during the day.

|
412
|
Thu Apr 3 18:46:04 2008 |
Andrey | Configuration | Computers | "Network switch board" and "c1pem1 crate" were touched |
While working with the weather station, I did two things that potentially (with a very small probability) might influence the smooth work of other processors/computers.
I did the following on Wednesday, April 2nd, in times between 1PM and 3PM.
(1) I turned off for several seconds and returned into the initial position the switch-key on the rack with computer (processor) 'c1pem1' in order to reboot processor 'c1pem1'. The turning off/on of that key-switch was repeated several times.
(2) I pulled gently the whole "Network-Switch Board" towards me in order to replace an ethernet cat 5 cable going into the board form the processor 'c1pem1'. Some other connections of other ethernet cables might be flimsy, and then other people in 40-meter might have problems with computers other than 'c1pem1'. It should not happen, but in case of extraordinary behaviour of any other computer in our lab, people should check the connectors on the network-switch board. It is located near the middle of Y-arm. See picture. |
Attachment 1: Computer_Rack.JPG
|
|
5779
|
Tue Nov 1 19:26:38 2011 |
Zach | Update | SUS | "Dr. SUS" progress |
EDIT: Ran Jamie's NDS2 reset method and it's still not serving up MC data.
I am debugging the SUS input matrix diagonalization code (which I have affectionately termed "Dr. SUS") offline by running everything except the actual writing of the matrices (%writeSUSinmat()) in a sandbox directory. Some notes:
- nodus doesn't know NDS2, but this isn't a problem given Kiwamu's reply, since we don't want to push results to the elog. I will still have the script push "optics kicked---don't touch" alerts to the elog, but I realized this can be done easily from a remote computer via in-script SSH commands. My next choice was pianosa, but even though she knows NDS2, she spits out MEX errors when I try to get data. Third stop was allegra, and she plays nice

- NDS2 is unable to read the MC mirror sensor data. Data from all other optics are retrieved without a problem. I verified that raw data was being written by plotting playback data in dataviewer, and I tried various times and the problem persisted. I suspect the problem is on the NDS2 server side:
The most recent entry in .../users/jzweizig/nds2-mafalda/channel_history shows nothing for MC1 2 or 3
mafalda:channel_history>more C-R-999986048-178368.cls | grep SENSOR
C1:SUS-BS_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-BS_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-BS_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-BS_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-BS_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-ETMX_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-ETMY_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-ITMX_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-ITMY_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-PRM_SENSOR_UR raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_LL raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_LR raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_SIDE raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_UL raw 0 real_4 2048 C-R
C1:SUS-SRM_SENSOR_UR raw 0 real_4 2048 C-R
|
5781
|
Wed Nov 2 01:53:08 2011 |
Zach | Update | SUS | "Dr. SUS" progress |
Now that NDS2 is working, I was able to run all parts of diagAllSUS (except for the matrix writing) without errors. Barring issues with standard commands (freeswing, turnOnWatchDogs.csh, caput, etc.), Dr. SUS should be ready to go.
As requested, I have suppressed the generation of an elog post containing the results of the diagonalization.
Dr. SUS will run on allegra as a cron job at 8:00am on Sundays:
allegra:peakFit>crontab -l
PATH=/bin/:/usr/bin/:/cvs/cds/caltech/apps/linux64/matlab/bin/:/cvs/cds/caltech/apps/linux/gds/bin/:/cvs/cds/caltech/apps/linux/tds/bin/
PWD=/cvs/cds/caltech/apps/linux/gds/lib/
LD_LIBRARY_PATH=/cvs/cds/caltech/apps/linux/gds/lib
01 05 * * 0 cat /cvs/cds/caltech/users/kiwamu/work/20091026_OMC-LSC-diag/src/OMC_LSC_timing.m | matlab -nosplash -nodesktop > /dev/null
0 8 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/runDrSUS
Also: should these variable definitions really be here?
|
5784
|
Wed Nov 2 11:29:04 2011 |
not Zach | Update | SUS | "Dr. SUS" progress |
Quote: |
Now that NDS2 is working, I was able to run all parts of diagAllSUS (except for the matrix writing) without errors. Barring issues with standard commands (freeswing, turnOnWatchDogs.csh, caput, etc.), Dr. SUS should be ready to go.
As requested, I have suppressed the generation of an elog post containing the results of the diagonalization.
Dr. SUS will run on allegra as a cron job at 8:00am on Sundays:
allegra:peakFit>crontab -l
PATH=/bin/:/usr/bin/:/cvs/cds/caltech/apps/linux64/matlab/bin/:/cvs/cds/caltech/apps/linux/gds/bin/:/cvs/cds/caltech/apps/linux/tds/bin/
PWD=/cvs/cds/caltech/apps/linux/gds/lib/
LD_LIBRARY_PATH=/cvs/cds/caltech/apps/linux/gds/lib
01 05 * * 0 cat /cvs/cds/caltech/users/kiwamu/work/20091026_OMC-LSC-diag/src/OMC_LSC_timing.m | matlab -nosplash -nodesktop > /dev/null
0 8 * * 0 /cvs/cds/rtcds/caltech/c1/scripts/SUS/peakFit/runDrSUS
Also: should these variable definitions really be here?
|
Cron starts with only a very minimal PATH. However, this shouldn't be an issue if you specify the full path to the commands.
The rest of the env vars should probably not be there.
Also, Zach: using /cvs/cds is now forbidden. We need to put this script in the right place. |
8370
|
Thu Mar 28 23:06:48 2013 |
Annalisa | Update | Auxiliary locking | "Alberto" NPRO laser again on PSL table |
"Alberto"NPRO laser has been moved again on PSL table in order to make a measurement of the beat note varying also the PSL temperature.
It is useful because if the PSL temperature would drift we have to know which is the NPRO temperature that returns the beat.
I'm going to measure it tomorrow.
|
4765
|
Wed May 25 19:19:11 2011 |
Jamie | Configuration | CDS | !!!CHECK IN YOUR MODELS!!! |
!!!CHECK IN MODEL CHANGES!!!
Today I found three models that were modified, but not checked in to the SVN repository:
M sus/c1/models/lib/sus_single.mdl
M isc/c1/models/c1lsc.mdl
M isc/c1/models/c1mcp.mdl
I checked in the c1lsc model, since I think it was just the change that Kiwamu made in http://nodus.ligo.caltech.edu:8080/40m/4749. I left the others, since I have no idea what they are or who made them.
Please please please remember to commit your model changes to the SVN after you're done. This is particularly important for important models, such as c1lsc. If you don't check in your changes I can pretty much guarantee that at some point you will loose them.
|
4668
|
Mon May 9 16:58:23 2011 |
Jamie | Bureaucracy | CDS | !!!!REMEMBER TO COMMIT YOUR MODIFICATIONS!!!! |
Whenever you modify any of the front-end code in /opt/rtds/caltech/c1/userapps, such as models, scripts or medm screens, REMEMBER TO COMMIT YOUR CHANGES, WITH A LOG MESSAGE!!!
cd /opt/rtcds/caltech/c1/userapps/trunk
svn commit path/to/modified/file
If you forget to commit things, they may be purged and you will loose your work. ALWAYS COMMIT!
Things to note and watch out for:
- When you commit, make sure you specify explicitly the path to the file that you are committing. This repository is shared by all LIGO sites, including the sites (LHO and LLO) so you really want to make sure you're not committing anything that affects anything other than "c1" (ie. the 40m)
- Only commit one file at a time, unless the changes to multiple files are tightly coupled.
- Never commit without specifying the path to the file that you are committing. Other people may be working on other files in the repository, and you don't want to commit their work with yours.
- YOU MUST LEAVE A LOG MESSAGE. Your log message should be specific to the file you have modified, and should be clear and verbose to explain exactly what you have done.
- Use the "svn status" command to give you an overview of what is going on in the working directory. This will tell you which files have been modified. See "svn help status" for more information.
If you have questions ASK. Don't force things. |
4669
|
Mon May 9 17:21:13 2011 |
Jamie | Bureaucracy | CDS | !!!!REMEMBER TO COMMIT YOUR MODIFICATIONS!!!! |
Also, remember to update the svn working copy before you begin doing any work, to make sure you're working on the most recent version:
cd /opt/rtcds/caltech/c1/userapps/trunk
svn update
|
1363
|
Fri Mar 6 01:04:49 2009 |
Kiwamu IZUMI | Configuration | IOO | !! lock-in amp disconnected !! |
The power supply of a lock-in amp, which is on the Y-arm side of PSL clean room, was pulled out by my mistake.
Then I reconnected it, but I don't know whether it is re-adjusted properly.
I'm sorry about this. If you are using that amp, it should be checked. |
12144
|
Wed Jun 1 15:01:56 2016 |
Steve | Update | SUS | wire standoffs update |
There are some issues with 5 mm sapphire prism Atm5. It will cause interference between one of the prisms and the Side OSEM.
Here are some drawings to see the issues with larger wire standoff.
The 2 mm prism will work.with a 1 mm longer dumbell.
Quotes requested from http://photomachining.com/laser-micromachining-photomachining-contact.html and http://www.optocity.com/
|
Attachment 1: 06011603.PDF
|
|
Attachment 2: 06011602.PDF
|
|
Attachment 3: sapphire_stand_off_v2.pdf
|
|
Attachment 4: side_OSEM_ETMY.jpg
|
|
Attachment 5: 5p2wsf.png
|
|
12146
|
Thu Jun 2 16:35:44 2016 |
Koji | Update | SUS | wire standoffs update |
Gap of the prism from the mirror
Sag: s = R(1-Cos[ArcSin[d/2/R]])
- Mirror curvature sag for 2mm prism (R=37.75mm): s=13um
- Minimum gap: 20um => s=33um => R=15mm
- Nominal gap: 35um => s=48um => R=10mm
- Maximum gap: 50um => s=63um => R=8mm
The second figure shows somewhat realistic arrangement of the pieces |
Attachment 1: sapphire_stand_off_v3.pdf
|
|
Attachment 2: arrangement-v3.pdf
|
|
12454
|
Tue Aug 30 15:44:28 2016 |
Steve | Update | SUS | wire standoffs update |
100 Sapphire prisms ordered. Delivery date 9-30-2016
~60 deg. prisms,
Size A=B=C=2 mm, length 5 mm
Material: sapphire
Surface quality: 5 micron RMS
Tolerances: +- 0.1 mm
This prism will be used as a mechanical component
No crystal orientation required
|
12550
|
Tue Oct 11 10:38:51 2016 |
Steve | Update | SUS | wire standoffs update |
100 Sapphire prizms arrived.
|
Attachment 1: A028_-_20161010_170319.jpg
|
|
Attachment 2: A027_-_20161010_170202.jpg
|
|
12760
|
Fri Jan 27 14:50:04 2017 |
Steve | Update | SUS | wire standoffs update |
The 3 pieces of Sapphire v-groove test cuts are back. They look good. The suspension wire 0.0017" ( 43 micron ) is show on some of the pictures. |
12761
|
Fri Jan 27 15:36:17 2017 |
Koji | Update | SUS | wire standoffs update |
Very nice! I got excited.
- Don't you ask Calum and co to check the groove size with their microscopes? Just give the samples and the wire.
- Do we want to make a simple "guitar" setup to measure the vibration Qs with Al piece, glass prism, ungrooved Sapphire, this grooved sapphire, grooved ruby, etc?
|
12846
|
Thu Feb 23 09:32:20 2017 |
Koji | Update | SUS | wire standoffs update |
Kyle took high quality images of the three sapphire prisms using the microscope @Downs. He analyzed the images to see the radius of the groove.
They all look sufficiently sharp for a 46um steel wire. Thumbs up.
I am curious to see how the wire Q is with grooved sapphires, ungrooved sapphires, grooved ruby, grooved aluminum stand off, and so on. |
Attachment 1: Sapphire_prism_1(A015).png
|
|
Attachment 2: Sapphire_prism_2(A016).png
|
|
Attachment 3: Sapphire_prism_3(A014).png
|
|
13030
|
Thu Jun 1 16:21:55 2017 |
Steve | Update | SUS | wire standoffs update |
Ruby wire standoff received from China. I looked one of them with our small USB camera. They did a good job. The long edges of the prism are chipped.
The v-groove cutter must avoid them. Pictures will follow.
|
12346
|
Thu Jul 28 08:42:36 2016 |
Steve | Update | SUS | wire clamp |
The clamp is in the machine for milling off the grooves. It's condition is normal. The edges needs some 800 sand paper so it is not sharp anywhere.
How did those nicks get on the edge? Fortunatelly they did not aligned with the wire.
|
Attachment 1: e12342.jpg
|
|
10076
|
Thu Jun 19 17:28:19 2014 |
Steve | Update | PSL | window device is ready for test |
The window is at the north west corner of the PSL enclosure.
The 1 mm thick BK7 window is AR coated both side R <0.08%, W2-PW1-1004-1064-0
The PZT stack is 0.75" OD, 0.25" thick with ~ 6 mm ID, motion range 2.5 micron at 200V
Soft silicon rubber isolation.
RXA: This is the opto-mechanical phase shifter that Steve has built for diagnosing scattered light problems. We put it into the reflected light path of any of the cavities and see if it can move the scattering noise from DC up to a higher frequency. e.g.:
The paper on this from GEO |
Attachment 1: softW2.jpg
|
|
Attachment 2: softW2b.jpg
|
|
9443
|
Thu Dec 5 11:06:43 2013 |
Steve | Update | Cameras | viewport video ccd cameras are all covered |
Quote: |
Quote: |
Can't we somehow hook up this camera to the MUX with the movie mode?
I think both the MUX and the sensoray are compatible with the color video signal.
Only the old CRT is B/W.
|
Watek 902H ccd with Tamron M118FM50 lens is hooked up to MUX Please be careful! In this set up the lens is close to the view port glass window!
|
PRM-BS & Faraday video ccd cameras covered as shown. These thin wall metalized ducts are perfect for blocking light in both direction.
They are very light and give you easy access to adjustment. |
Attachment 1: PRMcamera.jpg
|
|
Attachment 2: PRMcameraCover.jpg
|
|
Attachment 3: FaradayCameraCover.jpg
|
|
1459
|
Wed Apr 8 09:36:20 2009 |
steve | Configuration | VAC | valve condition changed to BG to calibrate the RGA |
Vacuum normal valve condition was changed to accommodate SRS-RGA calibration.
The annulus valves were closed to free TP3 to pump on the RGA
VM1 was closed to isolate the RGA from the IFO.
VM3 opened to TP3.
This condition is called back ground (BG) mode. It is where we can calibrate and see the RGA background without the IFO. |
14028
|
Thu Jun 28 08:09:51 2018 |
Steve | Update | CDS | vacuum pneumatic N2 pressure |
The fardest I can go back on channel C1: Vac_N2pres is 320 days
C1:Vac-CC1_Hornet Presuure gauge started logging Feb. 23, 2018
Did you update the " low N2 message" email addresses?
Quote: |
I moved the N2 check script and the disk usage checking script from the (sudo) crontab of nodus to the controls user crontab on megatron .
|
|
Attachment 1: 320d_N2.png
|
|
14029
|
Thu Jun 28 10:28:27 2018 |
rana | Update | CDS | vacuum pneumatic N2 pressure |
we disabled logging the N2 Pressure to a text file, since it was filling up disk space. Now it just sends an email to our 40m mailing list, so we'll all get a warning.
The crontab uses the 'bash' version of output redirection '2>&1', which redirects stdout and stderr, but probably we just want stderr, since stdout contains messages without issues and will just fill up again. |
11695
|
Fri Oct 16 18:27:52 2015 |
Steve | Update | VAC | vacuum normal condition |
Vacuum normal configuration with VM1-closed, VM2-open valve positions. Power load normal 24V 0.2A
Maglev rotation 560 Hz at room temp body temp.
"NO COMM" error message on medm screen. Gauge controller pressures are read able.
All vac comp LEDs are green. We have to reboot on Monday to enable communication.
|
Attachment 1: oct16Fpm2015.png
|
|
9514
|
Thu Jan 2 10:50:24 2014 |
Steve | Update | VAC | vacuum monitor is still blank |
The date is correct on this monitor.
Last stored RGA scan data Dec 20, 2013
IFO pressure at CC1 5.8e-6 Torr
Valve configuration: Vacuum Normal, confirmable only by manual checking of position indicators and pressure gauge controllers readouts
|
Attachment 1: Help.png
|
|
Attachment 2: vacation.png
|
|
Attachment 3: 20131220lastRGAscan.png
|
|
9515
|
Thu Jan 2 13:35:06 2014 |
Koji | Update | VAC | vacuum monitor is still blank |
We probably need to restart the machine, but I didn't want to touch c1vac1 and c1vac2. |
9581
|
Tue Jan 28 11:13:50 2014 |
Koji | Update | VAC | vacuum monitor is still blank |
[Steve Koji]
We pushed the reset button of c1vac1 and c1vac2 and the vacuum screen is back.
First, we pushed the reset button of c1vac1 and pushed the one on c1vac2.
This did not bring c1vac2 up. We pushed the reset of c1vac2 again and now everything of the vacuum screen is back. |
12209
|
Tue Jun 21 14:12:10 2016 |
Steve | Update | PEM | vacuum envelope wiped |
I wiped down the cranes with wet towel and Mario our janitor did the chamber tops with the tubes.
The optical tabels were not touched.
The outside temp peaked at 44 C yesterday
|
Attachment 1: 60dPEM.png
|
|
9582
|
Tue Jan 28 16:26:40 2014 |
Steve | Update | VAC | vacuum computers are back without safety |
Quote: |
[Steve Koji]
We pushed the reset button of c1vac1 and c1vac2 and the vacuum screen is back.
First, we pushed the reset button of c1vac1 and pushed the one on c1vac2.
This did not bring c1vac2 up. We pushed the reset of c1vac2 again and now everything of the vacuum screen is back.
|
1, Reset works
2, Default values are lost. They actually reversed into open and turn on everything when power recycle c1vac1, c1vac2 or 24V dc power supply. This can vent the IFO in an event of power failure!
It's may be the time to go back to an isolated, vacuum controller only computer.
The present valve configuration at Atm1
a, all annuloses are vented
b, valve cables disconnected at: VC1 and 4 IP gate valves
c, the RGA is off and it is pumped by the Maglev through VM2
d, cryo pump is being roughed with TP3 It's outgassing rate was 25 mTorr / min
e, Roughing hose is disconnected |
Attachment 1: c1vac1_vac2areback.png
|
|
9599
|
Wed Feb 5 08:14:59 2014 |
Steve | Update | VAC | vacuum computers are back without safety |
Quote: |
1, Reset works
2, Default values are lost. They actually reversed into open and turn on everything when power recycle c1vac1, c1vac2 or 24V dc power supply. This can vent the IFO in an event of power failure!
It's may be the time to go back to an isolated, vacuum controller only computer.
The present valve configuration at Atm1
a, all annuloses are vented
b, valve cables disconnected at: VC1 and 4 IP gate valves
c, the RGA is off and it is pumped by the Maglev through VM2
d, cryo pump is being roughed with TP3 It's outgassing rate was 25 mTorr / min
e, Roughing hose is disconnected
|
Vacuum checks before pump down:
1, check intermittent contact issue in black relay box
2, reconnect cable to ion pumps and vent them to atm before pump down
3, repeat power shutdown-reboot at atmosphere |
8356
|
Tue Mar 26 16:36:24 2013 |
Steve | Update | 40m Upgrading | table leveling mounts go here |
Quote: |
Steve's suggestion for how to level the end table using "swivel leveling mounts":

|
1, level table with 4 swivels, lock nuts 3/16 -vertical alignment 2, lock this position with 4 x 1/4-20 (these are in place already) to hold table in horizontal direction
Adjustable mount is here to compensate for bad tilting floor <http://www.mcmaster.com/#6111K52>
See grouting plans of the past http://nodus.ligo.caltech.edu:8080/40m/7248 |
Attachment 1: optabSTAND.PDF
|
|
Attachment 2: swivvelMountEE.jpg
|
|
8372
|
Fri Mar 29 16:30:27 2013 |
Steve | Update | 40m Upgrading | table leveling mounts go here |
Quote: |
Quote: |
Steve's suggestion for how to level the end table using "swivel leveling mounts":

|
1, level table with 4 swivels, lock nuts 3/16 -vertical alignment 2, lock this position with 4 x 1/4-20 (these are in place already) to hold table in horizontal direction
Adjustable mount is here to compensate for bad tilting floor <http://www.mcmaster.com/#6111K52>
See grouting plans of the past http://nodus.ligo.caltech.edu:8080/40m/7248
|
|
9257
|
Tue Oct 22 10:12:33 2013 |
Steve | Update | PEM | south arm AC intake duct checked |
The 4th week of no wet mopping of the floor and no wet wiping the vacuum envelope.
We cleaned the intakes of the south arm IFO air condition. The bottom duct have quite a bit accumulation Atm1
See wet wiped contrast on Atm2
We found 3 holes around pipes ( coming from CES ) on the east wall that has to be sealed.
After closer examination of these holes, they are sealed off well. |
Attachment 1: PEM0.5micron60d.png
|
|
Attachment 2: southArmIntakeNorth.jpg
|
|
Attachment 3: SouthArmMidIntakeWipe.jpg
|
|
2701
|
Tue Mar 23 10:11:13 2010 |
steve | Update | PEM | small air cond unit failed yesterday |
Old control room air condition failed yesterday around noon. It was blowing 80-85F hot air for about 2-3 hours at racks 1Y4-7 and the entry room 103 |
Attachment 1: 20datm.jpg
|
|
14299
|
Fri Nov 16 10:26:12 2018 |
Steve | Update | VAC | single viton O-rings |
The 40m vacuum envelope has one large single O-ring on the OOC west side. All other doors have double O-ring with annuloses.
There are 3 spacers to protect o-ring. They should not be removed!
The Cryo-pump static seal to VC1 also viton. All gate valves and right angle valve plates have single viton o-ring seal.
Small single viton o-rings on all optical quality viewports.
Helium will permiate through these fast. Leak checking time is limited to 5-10 minutes.
All other seals are copper gaskits. We have 2 manual right angle with METAL-dynamic seal [ VATRING ] as VV1 & RV1
|
Attachment 1: Single-O-ring.png
|
|
4350
|
Thu Feb 24 16:47:26 2011 |
steve | Configuration | PSL | shutter is back on the PSL output |
Uniblitz mechanical shutter was placed into the beam path of the PSL output with razor beam trap. The output power was 1.39W at 2.08A
It is working from the MEDM screen "old map" C1IOO_Mech_Shutter.adl |
Attachment 1: P1070441.JPG
|
|
14199
|
Tue Sep 18 14:02:37 2018 |
Steve | Update | safety | safety training |
Yuki Miyazaki received 40m specific basic safety training.
|
7434
|
Mon Sep 24 17:47:05 2012 |
Steve | Update | VAC | ready to pump |
The IFO will be at atmosphere overnight. The annuloses are pumped down. The access connector jam nuts are tightened to 45 ft/lbs
Actual pumpdown will start tomorrow morning. |
9980
|
Wed May 21 09:35:33 2014 |
Steve | Update | SUS | razor beam dumps ETMX_ISCT |
Quote: |
Anodized aluminum dumps replaced by 6 razor beam dumps.
Two more razor beam dumps added this afternoon. The picture will updated tomorrow.
|
There are 9 razor beam dumps at ETMY-ISCT |
Attachment 1: 9rbdETMY.jpg
|
|
12626
|
Fri Nov 18 15:10:06 2016 |
Steve | Update | General | projector shipped out for repair |
Vivitek D952HD sn2160130 was send out for warranty repair. It's hard to believe that it has a 5 year warranty...... RMA - WR16004483.....expected to be back by Friday, Dec 2
Quote: |
The projector failed just now with a pretty loud 'pop' sound - I've never been present when the lamp goes out, so I don't know if this is usual. I have left the power cable unplugged for now...
Replacement is ordered Nov 4
|
|
11915
|
Wed Jan 6 10:58:03 2016 |
Steve | Update | General | projector light bulb is out |
Projector light bulb ordered
Quote: |
[ Manasa, Ericq and Steve ]
Vivitek D952HD with 186 hours installed.
|
|
12596
|
Thu Nov 3 12:40:10 2016 |
gautam | Update | General | projector light bulb is out |
The projector failed just now with a pretty loud 'pop' sound - I've never been present when the lamp goes out, so I don't know if this is usual. I have left the power cable unplugged for now...
Replacement is ordered Nov 4 |
7595
|
Tue Oct 23 09:37:33 2012 |
Steve | Update | SUS | passive TT adjustment correction |
Quote: |
Tip Tilt pitch adjustment on existing-in vacuum suspension. This can be added by a simple installation of a 1.25" long 2-56 threaded rod with nuts.
|
We should check that their sus wire diameter are 0.0017" All 2-56 hardware are in and Bob is cleaning them. |
Attachment 1: IMG_1745.JPG
|
|
9374
|
Wed Nov 13 11:30:07 2013 |
Steve | Update | PEM | particle counter MOVED |
Particle counter moved from the top of IOOC to the east wall |
Attachment 1: Met1Moved.JPG
|
|