  16693   Wed Mar 2 12:40:08 2022 TegaUpdateVACOngoing work to get the FRG gauges readouts to EPICs channelsConnector Test:

A quick test to rule out any issue
with the Ethernet to Serial adapter was done
 6x 
  16701   Fri Mar 4 18:12:44 2022 KojiUpdateVACRGA pumping down1. Jordan reported that the newly installed
Pirani gauge for P2 shows 850Torr while PTP2
show 680 Torr. Because of this, the vacuum
 Screenshot_2022-03-04_19-38-11.png 
  16704   Sun Mar 6 18:14:45 2022 TegaUpdateVACOngoing work to get the FRG gauges readouts to EPICs channelsFollowing repeated failure to establish
communication between c1vac and the XGS600
controller via Perle IOLAN serial device
 iolan_xgs_comm_investigation.pdf 
  16706   Mon Mar 7 13:53:40 2022 TegaUpdateVACOngoing work to get the FRG gauges readouts to EPICs channelsSo it appears that my deduction from
the pictures of needing a cable swap was
correct, however, it turns out that the installed
 iolan_xgs_comm_live.pdf 
  16707   Mon Mar 7 14:52:34 2022 KojiUpdateVACOngoing work to get the FRG gauges readouts to EPICs channelsGreat trouble shoot!

> I guess, the only remaining
issue now is the incorrect atmospheric
  
  16713   Tue Mar 8 12:08:47 2022 TegaUpdateVACOngoing work to get the FRG gauges readouts to EPICs channelsOMG, it worked! It was indeed a calibration
issue and all I had to do was press the "OK"
button after selecting the "CAL"
 XGS600_calibration.pdf 
  16717   Wed Mar 9 10:23:28 2022 JordanUpdateVACLeak Testing of New Manual Gate Valve - Attempt #1Jordan, Chub, Paco

Chub and I went into the lab this
morning to leak check the new gate valve
  
  16721   Thu Mar 10 09:39:59 2022 JordanUpdateVACLeak Testing of New Manual Gate Valve - Attempt #2This morning Chub and I leak checked the
manual gate valve with the RGA and helium.
There was no change in the helium partial
 3-09-2022.PNG3-10-2022.PNG 
  16747   Tue Mar 29 15:07:11 2022 TegaSummaryVACOpening of MC and ETM chambers[Anchal, Chub, Ian, Paco, Tega]

Today, we opened the MC chamber,
ETMX chamber and ETMY chamber.
  
  16769   Mon Apr 11 11:00:30 2022 JancarloUpdateVACC1VAC Reboot and Nitrogen tanks[Paco, JC, Ian, Jordan, Chub]

Checking in the morning, I walked
over to the Nitrogen tanks to check the levels.
  
  16772   Tue Apr 12 09:05:21 2022 JordanUpdateVACNew Pressure Gauge Install/Pump Spool VentToday, Tega and I would like to vent the
pump spool an dinstall the new FRG-400 Agilent
Pressure Gauges (per elog 15703). The attached
 6x 
  16773   Wed Apr 13 12:50:07 2022 TegaUpdateVACNew Pressure Gauge Install/Pump Spool Vent[Jordan, JC, Tega]

We have installed all the FRGs
and updated the VAC medm screens to display
 VAC_FRG_UPGRADE.png 
  16777   Thu Apr 14 09:04:30 2022 JordanUpdateVACRGA Volume RGA ScansPrior to venting the RGA volume on Tuesday
(4/12/2022) I took an RGA scan of the volume
to be vented (RGA+TP1 volume+Manual Gate
 40mRGA_Overlay.pdfRGAVolume_4_12_22.PNG 
  16794   Thu Apr 21 11:31:35 2022 JCUpdateVACGauges P3/P4[Jordan, JC]

It was brought to attention during
yesterday's meeting that the pressures
 IMG_0560.jpegIMG_0561.jpeg 
  16796   Thu Apr 21 16:36:56 2022 TegaUpdateVACcleanup work for vacuum git repogit repo - https://git.ligo.org/40m/vac

Finally incorporated the FRGs into
the main modbusIOC service and everything
  
  16806   Fri Apr 22 14:14:33 2022 JordanUpdateVACTP3 Forepump tip seal replacementJordan, JC

While the pumpspool is vented,
I thought it would be a convenient time to
 IMG_0572.jpegIMG_0573.jpeg 
  16820   Fri Apr 29 08:34:40 2022 JCUpdateVACRGA Pump DownJordan and I, in order to start pumpig
down the RGA Volume, we began by opening
V7 and VM. Afterwards, we started RP1 and
 Screen_Shot_2022-04-29_at_8.46.53_AM.png 
  16822   Mon May 2 10:00:34 2022 JordanUpdateVACTP3 Forepump tip seal replacement[JC, Jordan]

Jordan recieved the new tip seal
Friday afternoon and I continued the replacement
  
  16825   Tue May 3 13:18:47 2022 JCUpdateVACRGA Pump DownJordan, Tega, JC

Issue has been resolved. Breaker
on RP1 was tripped so the RP1 button was
  
  16867   Fri May 20 12:42:23 2022 TegaUpdateVACDoor installation on the end stations[JC, Tega, Chub]

Today we installed the 200 lbs
doors on the end station chambers.
  
  16870   Tue May 24 10:37:09 2022 TegaUpdateVACadded FRG channels to slow channel ini file[Vacuum gauge sensors]

Paco informed me that the FRG sensor
EPICS channels are not available on dataviewer,
  
  16871   Tue May 24 11:04:53 2022 JCUpdateVACBeginning Pumpdown[JC, Jordan, Paco, Chub]

We began with the pumpdown this
morning. We started with the annulus volume
 PUMPDOWN-2022-05-24_16-57-59.pngC1VAC_Screenshot_2022-05-24_16-59-27.png 
  16900   Wed Jun 8 16:03:12 2022 KojiUpdateVACPower Outage 220608: Vacuum Recovery=== Observation ===


TP1/2/3 failed. AUX RP
did not survive the power outage (of course)


===
 Screenshot_2022-06-08_16-43-13.png 
  16916   Wed Jun 15 07:26:35 2022 JCUpdateVACBeginning Pumpdown[Jordan, JC]

Jordan and I went in to retore
the Vacuum System back to it's original
  
  16980   Fri Jul 8 14:03:33 2022 JCHowToVACVacuum Preparation for Power Shutdown [Koji, JC]

Koji and I have prepared the vacuum
system for the power outage on Saturday.
 Screen_Shot_2022-07-12_at_7.02.14_AM.png 
  16985   Mon Jul 11 15:26:12 2022 JCHowToVACStartup after Power Outage[Koji, Jc]

Koji and I began starting that
Vacuum system up.
  
  16986   Mon Jul 11 17:25:43 2022 TegaUpdateVACfixed obsolete reference bug in serial_XGS600 serviceKoji noticed that the FRG sensors were
not updating due to reference to an
obsolete modbusIOC_XGS service, which was
  
  16987   Mon Jul 11 17:41:52 2022 KojiHowToVACStartup after Power Outage- Once the FRG gauge readings are back
(see next elog by Tega), I could open V1
to pump down the main vacuum manifold.
 Screen_Shot_2022-07-11_at_18.13.00.png 
  17154   Fri Sep 23 10:05:38 2022 JCUpdateVACN2 Interlocks triggered [Chub, Anchal, Tega, JC]

After replacing an empty tank this
morning, I heard a hissing sound coming from
 Screenshot_2022-09-23_10-19-39.pngScreenshot_2022-09-23_10-22-45.png 
  17283   Fri Nov 18 09:00:27 2022 JCUpdateVACPressure Gauge InformationI bought the spare Full-Range Pirani Gauge
a while ago and realized that I never logged
this. The Pirani Gauges we are using is described
  
  17307   Wed Nov 23 17:21:44 2022 JCUpdateVACInterlocks may have been tripped due to N2 pressure loss[Paco, JC]

While changing out one of the N2
tanks today, one of the fitting stripped.
 Screen_Shot_2022-11-23_at_5.22.57_PM.pngScreen_Shot_2022-11-23_at_5.23.09_PM.png 
  17312   Fri Nov 25 12:15:46 2022 AnchalUpdateVACVacuum Gate valves restoredI came today to find that PSL shutter was
closed. I orginially thought some shimmer
obersvations are underway in the quiet state.
 Screenshot_2022-11-25_12-29-23.png 
  4274   Fri Feb 11 16:43:09 2011 steveUpdateVIDEOMC1 & 3 video monitorI set up video monitoring of MC1 and MC3  P1070415.JPG 
  4314   Thu Feb 17 13:20:06 2011 SureshUpdateVIDEOSome more labels[Larisa, Kiwamu, Steve and Suresh]
 
  We continued the labeling
  
  4346   Wed Feb 23 16:56:17 2011 Larisa ThorneUpdateVIDEOCable laying...continuedHaving finished labeling the existing cables
to match their new names, we (Steve, Kiwamu
and Larisa) moved on to start laying new
  
  4390   Wed Mar 9 16:07:42 2011 kiwamuUpdateVIDEOcable session[Koji, Steve, Suresh, Kiwamu]
The following video cables have been
newly laid down :
  
  4462   Wed Mar 30 17:01:08 2011 Larisa ThorneUpdateVIDEOCable laying...continued[Steve, Suresh, Kiwamu, Larisa]
 
Only the PRM/BS cable was laid today.
  
  4474   Thu Mar 31 08:31:44 2011 SureshUpdateVIDEOCable laying...continuedThe video work has crossed a milestone.    
Kiwamu and Steve have shifted the
three quads from the control room to
 P1070489.JPGP1070494.JPG 
  4498   Thu Apr 7 13:12:23 2011 KojiHowToVIDEOVideo switching tipLong time ago, I looked at the manual of
the video switcher. 
  
  4529   Fri Apr 15 02:30:24 2011 KojiHowToVIDEOVideo switching tipI have made a small python script to handle
the video matrix.
It is too far from the perfection,
  
  4546   Wed Apr 20 20:42:55 2011 kiwamuUpdateVIDEOtoday's video session[Steve / Suresh / Kiwamu]
90
% of unused video cables have been removed.
 DSC_2931_ss.jpgDSC_2938_ss.jpg 
  5265   Thu Aug 18 22:24:08 2011 jamieOmnistructureVIDEOUpdated 'videoswitch' scriptI have updated the 'videoswitch' program
that controls the video MUX.  It now
includes the ability to query the video mux
  
  6991   Thu Jul 19 02:14:37 2012 JenneUpdateVIDEOMade a video guiI learned a little bit of python scripting
while looking at the videoswitch script,
and I made a video medm screen. 
  
  7020   Tue Jul 24 18:33:12 2012 YaakovUpdateVIDEOCentering the MCR cameraJenne and I centered the MCR camera   
  7026   Wed Jul 25 11:41:00 2012 YaakovUpdateVIDEOCentering the MCR camera

    

       
            
  
  135   Wed Nov 28 19:02:41 2007 AndreyBureaucracyWIKI-40M UpdateNew WIKI-40M page describing Matlab Suspension Modeling
I created the WIKI-40m page with some details
about my today's talk on the 40-m lab meeting.
  
  219   Wed Jan 2 11:38:56 2008 tobinSummaryWIKI-40M Updatewiki spamOur wiki keeps getting spammed.  It turns
out that you can upload attachments without
a password, which is a bug.  I'll ask David
  
  1941   Tue Aug 25 03:30:23 2009 YoichiSummaryWIKI-40M UpdateGreen lock and phase noiseWhile Koji and I were discussing about the
green laser lock, we wondered if the common
motion of the cavity mirrors,
 PhaseNoise.png 
  2127   Wed Oct 21 11:41:29 2009 ZachUpdateWIKI-40M UpdatePSL Table Diagram wiki entry I made a wiki entry for the PSL table
diagram under the PSL directory on the 40mHomePage.
I tried to use the ImageLink macro to use
  
  2128   Wed Oct 21 13:07:54 2009 KojiUpdateWIKI-40M UpdatePSL Table Diagram wiki entryhttp://lhocds.ligo-wa.caltech.edu:8000/40m/PSL_Table_Diagram
Thanks. I love this. Could you also
put the original file that is editable for
  