40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
40m Log, Page 333 of 336
Not logged in
List
|
Find
|
Login
|
Help
Full
|
Summary
| Threaded |
Collapse
|
Expand
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Type --
Configuration
Update
Summary
HowTo
Bureaucracy
Omnistructure
Metaphysics
Frogs
16796 Entries
Goto page
Previous
1
,
2
,
3
...
332
, 333,
334
,
335
,
336
Next
Wed Jun 20 18:09:23 2012, yuta, Update, Locking, both arms aligned, ITMX oplev centered
Wed Jun 20 18:43:57 2012, yuta, Update, LSC, calibrated POX error signal
Thu Jun 21 12:56:49 2012, yuta, Update, Locking, ETMX 1064 trans camera
Thu Jun 21 15:36:51 2012, yuta, Update, Locking, X arm alignment
Fri Jun 22 10:52:18 2012, yuta, Update, Green Locking, 2 arm ALS - Success!!!!
Sat Jun 23 02:29:18 2012, yuta, Update, Green Locking, X arm mode scan results
Sat Jun 23 19:57:22 2012, yuta, Summary, Computers, c1ioo is down
Sun Jun 24 00:10:45 2012, yuta, Update, Green Locking, current beat electronics
Sun Jun 24 23:42:31 2012, yuta, Update, Computer Scripts / Programs, PMC locker
Mon Jun 25 15:07:49 2012, yuta, Update, IOO, MC beam spot trend
Mon Jun 25 17:48:27 2012, yuta, Update, Computer Scripts / Programs, script for finding IR resonance using ALS
Tue Jun 26 00:52:18 2012, yuta, Update, Computer Scripts / Programs, PMC locker
Tue Jun 26 01:30:13 2012, yuta, Summary, Green Locking, simultaneous hold and release of the arm (aka two arm ALS)
Tue Jun 26 22:37:43 2012, yuta, Update, IOO, energized OMC stages
Wed Jun 27 03:43:52 2012, yuta, Summary, IOO, how to improve mode matching to arms
Wed Jun 27 16:23:12 2012, yuta, Update, IOO, AS and REFL on AP table aligned
Wed Jun 27 23:54:21 2012, yuta, Update, Computer Scripts / Programs, image capturing script
Thu Jun 28 00:50:48 2012, yuta, Update, Locking, PRMI work started, commissioning plan
Thu Jun 28 20:59:28 2012, yuta, Bureaucracy, Locking, vent for PRC check, TOMORROW!
Fri Jun 29 01:49:36 2012, yuta, Bureaucracy, Locking, vent for PRC check, TOMORROW!
Fri Jun 29 02:17:40 2012, yuta, Update, IOO, prep for the vent - beam attenuating
Fri Jun 29 03:21:32 2012, yuta, Update, General, prep for the vent - others
Fri Jun 29 16:41:41 2012, yuta, Update, General, PRM was NOT installed backwards
Sun Jul 1 13:20:09 2012, yuta, Update, IOO, MC in low power
Sun Jul 1 23:48:15 2012, yuta, Summary, General, clipping at BS, my plan
Mon Jul 2 18:27:25 2012, yuta, Update, General, BS and ITMX chambers closed
Tue Jul 3 20:51:06 2012, yuta, Update, IOO, MC in vacuum is back
Wed Jul 4 20:13:46 2012, yuta, Bureaucracy, Locking, PRC commissioning plan
Wed Jul 4 21:11:53 2012, yuta, Update, Locking, FPMI in vacuum is back
Thu Jul 5 01:20:58 2012, yuta, Summary, CDS, slow computers, 0x4000 for all DAQ status
Thu Jul 5 01:34:11 2012, yuta, Update, Locking, MI with X arm ALS
Thu Jul 5 13:38:05 2012, yuta, Summary, Locking, cavity g-factor from mode scan
Fri Jul 6 01:39:56 2012, yuta, Update, Locking, MI + Y arm ALS succeed, but not both
Fri Jul 6 02:46:03 2012, yuta, Update, Locking, Y arm ALS handing off to LSC
Fri Jul 6 14:10:31 2012, yuta, Summary, LSC, calculation of FPMI using ALS
Sun Jul 8 00:27:54 2012, yuta, Summary, Locking, calibrating phase tracking mode scan data
Sun Jul 8 19:31:53 2012, yuta, Update, Locking, characterizing LSC arm lock by ALS error signal
Mon Jul 9 05:02:58 2012, yuta, Update, Locking, adjusted ALS filters, current RMS
Mon Jul 9 05:15:46 2012, yuta, Update, Green Locking, locked MI while ALS using ASDC
Mon Jul 9 23:18:09 2012, yuta, Update, LSC, PRMI got more stable a bit
Tue Jul 10 03:16:17 2012, yuta, Update, LSC, PRMI got more stable a bit
Tue Jul 10 17:47:55 2012, yuta, Update, SUS, PRM oplevs fixed
Tue Jul 10 21:37:05 2012, yuta, Update, LSC, PRMI glitch study
Wed Jul 11 02:25:11 2012, yuta, Update, LSC, PRMI beam spot motion might be from PRM/BS motion
Wed Jul 11 03:53:41 2012, yuta, Update, LSC, BS 3.3 Hz motion on MI
Wed Jul 11 13:36:58 2012, yuta, Update, SUS, OSEM and oplev spectra of optics
Wed Jul 11 16:19:08 2012, yuta, Update, SUS, oplev servo phiology
Thu Jul 12 02:12:42 2012, yuta, Update, SUS, BS 3.3 Hz motion
Thu Jul 12 13:27:16 2012, yuta, Update, SUS, measured OLTFs of PRMI optics' SUSPOS
Thu Jul 12 23:15:34 2012, yuta, Update, LSC, PRMI LSC is making PRM motion worse
Goto page
Previous
1
,
2
,
3
...
332
, 333,
334
,
335
,
336
Next
ELOG V3.1.3-