40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 333 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  12211   Wed Jun 22 10:15:45 2016 varunUpdateCDSDAFI update: stereo outputI have updated the DAFI with the following
changes:

1) Separated both the channels
 C1DAF_OVERVIEW.pngDAF_link_from_LSC.png 
  12215   Mon Jun 27 15:12:09 2016 varunUpdateCDSDAFI update: stereo outputUsing an RC to BNC connector from the inner
drawer, I have added a second output cable
going from the output Fibox in the control
 IMG_20160627_151753247.jpg 
  12242   Tue Jul 5 14:12:56 2016 varunUpdateElectronicsAntialiasing Filter UpdateI am trying to design an antialiasing filter,
which also has two switchable whitening stages.
I have designed a first version of a PCB
 AA.pdfAAtop.pdfAAbottom.pdfAAbrd.pdfAA.zip 
  12266   Thu Jul 7 12:44:52 2016 varunUpdateCDSDAFI updateAttached is a diagram, showing the entire
(planned) signal flow of the DAF model. Some
thoughts on the implementation after discussion
 DAFI.pdf 
  12282   Fri Jul 8 22:26:03 2016 varunUpdateCDSDAFI Update: Changes in LSC modelI have added the control signals DARM_CTRL,
MICH_CTRL, PRCL_CTRL, SRCL_CTRL, CARM_CTRL,
XARM_CTRL, YARM_CTRL, MC_CTRL to the
 lsc.pnglsctodaf.pnglsctodaf1.png 
  12287   Sun Jul 10 20:08:44 2016 varunUpdateCDSDAFI Update: Changes in LSC and PEM modelsI have added the PEM signals mentioned
in the previous elog as DAF inputs through
PCIE IPC, and compiled and restarted the
 pemtodaf.pngpemindaf.png 
  12303   Thu Jul 14 23:38:59 2016 varunUpdateCDSc1lsc FE unresponsiveToday, at around 10:30, c1lsc machine froze
and stopped responding to ping and ssh after
I compiled and restarted c1daf. I think it
  
  12304   Fri Jul 15 12:21:28 2016 varunUpdateCDSc1lsc FE unresponsivec1lsc is up and running, Eric did a manual
reboot today.

  
  12307   Sat Jul 16 00:30:42 2016 varunUpdateCDSDAFI update: Frequency warping | c1lsc unresponsiveSummary: I am trying to
implement frequency warping/pitch shifting
on the real time FE. Here is a description
  
  12309   Mon Jul 18 18:44:52 2016 varunUpdateCDSc1lsc FE recoveredc1lsc FE is up and running.

Details:

2) The machine was manually rebooted.
 CDS_status160718.png 
  12319   Thu Jul 21 12:03:35 2016 varunUpdateCDSDAFI update: Humming noise in DAFI output 


Summary: There
 New_Doc_13.pdf 
  12320   Thu Jul 21 14:27:24 2016 varunUpdateCDSDAFI Update: Arbitrary Math blockSummary: I have added
an arbitrary math block to the DAFI model,
which takes two inputs, say X and Y, and
 dafioverview.pngarbmath.png 
  12321   Thu Jul 21 15:03:13 2016 varunUpdateCDSDAFI Update1) I have added the status summary of the
DAFI block to the main FE status overview
screen in the c1lsc cloumn. (attachment 1)
 festatus.pngmatrices.png 
  12324   Thu Jul 21 22:02:35 2016 varunUpdateCDSDAFI update: Frequency warpingThe code for frequency warping contained
a "printf()" command, which had
caused the system to crash in one another
 07212016.png 
  6   Sat Oct 20 11:54:13 2007 waldmanOtherOMCOMC and OMC-SUS work[Rich, Chub, Pinkesh,  Chris,  Sam]

Friday the 18th was a busy day in OMC land.
  
  14   Thu Oct 25 17:52:45 2007 waldmanOtherOMCOMCs with QPDs[Rich, Chub, Pinkesh, Sam]

Yesterday we got the QPD, OTAS, and PZT cabling
  
  16   Thu Oct 25 23:35:36 2007 waldmanOtherOMCHang the OMC![Pinkesh, Sam]

We tried,  convicted and hung the OMC today.
 IMG_1483.jpgIMG_1481.jpg 
  19   Fri Oct 26 17:34:43 2007 waldmanOtherOMCOMC + earthquake stops
[Chub, chris, Pinkesh, Sam]
  
  20   Fri Oct 26 21:48:40 2007 waldmanConfigurationOMCFiber to 056I set up a 700 mW NPRO in Rana's lab and launched
it onto a 50m fiber.  I got a few mW onto
the fiber,  enough to see with a card before
  
  21   Sat Oct 27 19:00:44 2007 waldmanConfigurationOMCHanging, locked OMC with REFL extracted.I got the OMC locked to the fiber output today.
 It was much more difficult than I expected
and I spent about 30 minutes or so flailing
  
  25   Mon Oct 29 11:07:22 2007 waldmanSoftware InstallationOMCSoftware install on OMS[Alex, Sam]

We spent a little time this morning working
  
  26   Mon Oct 29 12:20:15 2007 waldmanConfigurationOMCChanged OMS filtersI changed the OMS configuration so that some
of the OMC-SUS LED channels go to a breakout
box so that we can input the PDH error signal.
  
  27   Mon Oct 29 23:10:05 2007 waldmanConfigurationOMCLost in DAQspace[Pinkesh, Sam]

In setting up a Digital based control of
 SS.pdfSS.gif 
  37   Wed Oct 31 09:45:28 2007 waldmanOtherOMCResolution to DAQland saga[Jay, Sam]

We did a rough accounting for the linear
  
  42   Wed Oct 31 23:55:17 2007 waldmanOtherOMCQPD testsThe 4  QPDs for the OMC have been installed
in the 056 at the test setup.  All 4 QPDs
work and have medm screens located under
 QPD_SignalSpectrum.pdfQPD_SignalSpectrum.gif 
  43   Thu Nov 1 01:28:04 2007 waldmanOtherOMCFirst digital lock of OMC[Pinkesh, Sam]

We locked a fiber based NPRO to the suspended
 071101_PZT_firstLoopSweep.pdf071101_PZT_firstLoopSweep.gif071101_OMC_FirstLock_spectra.pdf071101_OMC_FirstLock_spectra.gif 
  58   Fri Nov 2 12:18:47 2007 waldmanSummaryOMCLocked OMC with DCPD[Rich, Sam]

We locked the OMC and look at the signal
 071102_OMC_LockedDCPD.gif071102_OMC_LockedDCPD.pdf 
  59   Sat Nov 3 16:20:43 2007 waldmanSummaryOMCA good day's work
I followed up yesterday's test of the PZT
with a whole mess of characterizations of
 6x 
  60   Sun Nov 4 23:22:50 2007 waldmanUpdateOMCOMC PZT and driver response functionsI wrote a big long elog and then my browser
hung up,  so you get a less detailed entry.
 I used Pinkesh's calibration of the PZT
 7x 
  63   Mon Nov 5 14:44:39 2007 waldmanUpdateOMCPZT response functions and De-whiteningThe PZT has two control paths:  a DC coupled
path with gain of 20,  range of 0 to 300
V,  and a pair of 1:10 whitening filters,
 07110_DithertoVmonAC_sweep2-0.png071105_LSCtoVmonDC_sweep4-0.png07110_DithertoVmonAC_sweep2.pdf071105_LSCtoVmonDC_sweep4.pdf 
  79   Wed Nov 7 14:01:31 2007 waldmanOmnistructureOMCFrequency and Intensity noiseOne of the biggest problems I had using the
PZT to lock was excessive noise.  I did a
little noise hunting and found that the problem
  
  86   Fri Nov 9 00:01:24 2007 waldmanOmnistructureOMCOMC mechanical resonances (Tap tap tappy tap)[Pinkesh, Aidan, Sam]

We did a tap-tap-tappy-tap test of the OMC
 7x 
  179   Fri Dec 7 11:33:24 2007 waldmanOmnistructureOMCPZT wiringThe 2 pin LEMO connector has got an unmarked
pin and a pin marked by a white half-circle.
The unmarked pin is connected to the side
  
  206   Thu Dec 20 19:05:34 2007 waldmanHowToOMCHOWTO build front endsFor instance,  to build the TPT front end
code.
  
  207   Thu Dec 20 19:10:03 2007 waldmanUpdateOMCStressful reattachment of heaterPhotos may follow eventually,  but for now
here's the rundown.  I scraped the heater
clean of the thermal epoxy using a clean
  
  14193   Wed Sep 5 10:59:23 2018 wgautamUpdateCDSCDS status updateRolf came by today morning. For now, we've
restarted the FE machine and the expansion
chassis (note that the correct order in which
  
  14816   Mon Jul 29 19:08:55 2019 yehonathanUpdateLoss MeasurementReviving loss measurement by reflection1. X arm is totally misaligned in order
to measure the Y arm loss using the reflection
method. Each measurement round consists of
  
  14827   Mon Aug 5 14:47:36 2019 yehonathanUpdateLoss Measurement Summary:

I analyze the 100 reps loss measurement
of the Y arm using the AnalyzeLossData.ipynb
  
  Draft   Mon Aug 5 16:28:41 2019 yehonathanUpdateLoss Measurementwhat is going on with the loss measurements ?We hypothesize that the systematic error
in the loss measurement can come from the
fact that the requirement on the alignment
  
  14830   Mon Aug 5 17:36:04 2019 yehonathanUpdateLoss Measurement We check for unexpected drifts in the PD
reading (clipping and such). We put a pickoff
mirror where the PD used to be and place
 20190805_171511.jpg 
  14831   Tue Aug 6 14:12:02 2019 yehonathanUpdateComputersmaking rossa great againcdsutils is not working on rossa.

Import cdsutils produces this error:

In [2]: import cdsutils
  
  14834   Tue Aug 6 16:44:50 2019 yehonathanUpdateLoss Measurement I grab 2 hours of the PD measurements using
dlData_simple.ipynb in the misaligned state.

I get pretty much a normally distributed
 figure_1.pngfigure_1-1.png 
  15116   Fri Jan 10 19:48:46 2020 yehonathanUpdatePSLAssembly underway for c1psl upgrade{Yehonathan, Jon}

I finished pre-wiring the PSL chassis.
I mounted the Acromags on the DIN rails and
 20200110_194429.jpg20200110_194516_HDR.jpg 
  15118   Mon Jan 13 16:05:18 2020 yehonathanUpdatePSLAssembly underway for c1psl upgrade{Yehonathan, Jon}

I configured the Acromag channels
according to the Slow
  
  15120   Tue Jan 14 17:16:43 2020 yehonathanUpdatePSLAssembly underway for c1psl upgrade{Yehonathan, Jon}

I isolated a BIO Acromag completely
from the chassis and powered it up. The inverted
  
  15262   Tue Mar 10 14:30:16 2020 yehonathanUpdateSUS ETMX was grossly misaligned.

I re-aligned it and the X arm now
locks.
 Screenshot_from_2020-03-10_19-02-31.png 
  15263   Tue Mar 10 19:58:16 2020 yehonathanUpdateSUS I returned the triggering threshold to
normal values (5/3).

  
  15614   Tue Oct 6 07:37:20 2020 yehonathanUpdateWikiNew TIS measurements of 40m OpticsLiYuan has kindly done some Total Integrating
Sphere (TIS) measurements on ITMU01 and ITMU02.
A summary of the measurement is attached.
 ITMU_sn01-02_tis_1.pdf 
  15788   Tue Feb 2 17:09:17 2021 yehonathanUpdateBHDSOS assemblyI set up a working area on the table next
to the south flow bench (see attachment).
I also brought in a rolling table for some
 20210202_165501.jpg20210202_162452.jpg 
  15816   Thu Feb 18 15:15:12 2021 yehonathanUpdateSUSOSEM testing for SOSsI am setting up a testing rig for the OSEMs
we recently obtained. I found the schematic
for the OSEM assembly from which the pin
 OSEM_Pin_Plate.png 
ELOG V3.1.3-