40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 333 of 344  Not logged in ELOG logo
ID Date Authordown Type Category Subject Text Attachments
  17322   Tue Nov 29 15:32:32 2022 AnchalUpdateBHDc1hpc model updates to support double audio ditherMany changes have been done to c1hpc to
support dual demodulation at audio frequencies.
We moved away with ASS style of lockin setup
 Screenshot_2022-11-29_15-36-05.png 
  17329   Thu Dec 1 20:43:25 2022 AnchalSummaryCalibrationSingle arm cal with 5 lines[Anchal, Paco]

We are doing this attempt again
in following configuration:
 SingleArmCalibration.png 
  17331   Sat Dec 3 10:13:56 2022 AnchalUpdateSUSLow noise stateI've turned off HEPA fan and all lights
at:

PST: 2022-12-03 10:13:03.184705
  
  17332   Sat Dec 3 17:42:25 2022 AnchalUpdateASCIMC WFS Fixed for nowToday I did a lot of steps to eventually
reach to WFS locking stably for long times
and improving and keeping the IMC transmission
 IMC_WFS_OLTF.pdf 
  17334   Sun Dec 4 16:44:04 2022 AnchalUpdateASCIMC WFS Fixed for nowToday, I worked on WFS loop output matrix
for PIT DOFs.


I began with the matrix
 IMC_WFS_OLTF_All_Gains_1.pdfIMC_WFS_OLTF_Nom_Gain.pdfWFS_Loop_Configuration.pngWFS_Loop_Performance.png 
  17335   Mon Dec 5 12:05:29 2022 AnchalUpdateCDSc1sus2 all FE models crashed spontaneouslyJust a few minutes ago, all models on FE
c1sus2 crashed. I'm attaching some important
files that can be helpful in investigating
 c1sus2Failed.txtc1sus2Failed.png 
  17336   Mon Dec 5 16:24:45 2022 AnchalUpdateASCIMC WFS servo diagnosis Also reply to: 40m/17255


I ran the toggleWFSoffsets.py
script to generate a step response of the
 IMC_WFS_Step_Response.pdf 
  17337   Mon Dec 5 20:02:06 2022 AnchalUpdateASCIMC WFS heads electronic feasibility test for using for Arm ASCI took transfer function measurement of
WFS2 SEG4 photodiode between 1 MHz to 100
MHz in a linear sweep.
 20221205_193105_WFS2_SEG4_RF_TF_Screenshot.pngPXL_20221206_033419110.jpg 
  17342   Tue Dec 6 16:52:26 2022 AnchalUpdateASCIMC WFS heads electronic feasibility test for using for Arm ASCI tested teh WFS demod board for possibility
of demodulating 11 MHz or 55 MHz signal with
it. It definitely has some bandpass filter
 WFS1_SEG2_DEMOD_Test.pdf11MHz.png29.5MHz.png55MHz.png 
  5243   Mon Aug 15 21:43:29 2011 Anamaria and KeikoSummaryLockingcentral part ifo locking project REFL33 and REFL165 cables were connected
from the AP table to the rack.  Cables
on the rack for REFL33I, 33Q, 165I, 165Q
  
  5249   Tue Aug 16 16:59:20 2011 AnamariaUpdateRF SystemAM in the PMKiwamu, Keiko, Anamaria
Looking at the I and Q signals coming
from REFL11 and REFL55 we saw large offsets,
  
  5255   Wed Aug 17 15:47:18 2011 AnamariaUpdateSUSETMX Side Sensor slow channel down for a long timeJenne, Anamaria
We aligned the ETMX OSEMs and ran
into this issue. Looking at the SENSOR_SIDE
  
  5278   Mon Aug 22 20:37:43 2011 AnamariaConfigurationRF SystemPlan for install of 3f PDsI made a quick sketch of how to include
two more RF PDs on the REFL beam, given the
space we have on the table. We want to install
 40m3fReflPdLayout.pdf 
  5284   Tue Aug 23 06:49:24 2011 AnamariaUpdateGeneralmore in-vac work : AS clipping fixed and OSEM/oplev adjustmentWhere was the AS clipping?! Ah, the suspense...


  
  5389   Mon Sep 12 18:45:04 2011 AnamariaConfigurationLSCAP table current layoutBefore we install the REFL 3f PDs I made
a drawing of the current table layout, since
there has been no update lately. Once I've
 40mAPtable.pdf 
  5401   Wed Sep 14 01:19:20 2011 AnamariaConfigurationLSC3f PD Install in ProgressI have reconfigured the refl beam path
on the AP table to include REFL33 and REFL165.
Would be done if we hadn't prepared P BSs
  
  5414   Thu Sep 15 02:18:19 2011 AnamariaUpdateLSCMICH locked and attempt to lock PRCLKiwamu, Keiko, Anamaria
 
We were able to lock PRC using REFL11I
  
  5430   Fri Sep 16 03:22:11 2011 AnamariaUpdateLSCMore Refl PDs Work and Attempt at DRMIKiwamu, Keiko, Anamaria
I started today with a different
input beam, so I had to realign the REFL
  
  5475   Tue Sep 20 03:12:14 2011 AnamariaUpdateSUSJenne's Scripts startedI followed Jenne's instructions, ran the
matrix filler script and then set the optics
to freeswing. Someone has to burt resture
  
  5489   Tue Sep 20 20:58:35 2011 AnamariaConfigurationLSCNew AP Table DrawingAs promised, I have made a final AP table
drawing, including the MC camera relocation
changes by Kiwamu. I have posted it in the
 APtableSep20th.pdf 
  5513   Thu Sep 22 04:49:14 2011 AnamariaUpdateLSCLocking status update - Some Scripts, No LouckThe scripts I wrote can be found in /users/anamaria/scripts/sensemat/
]There are two of them:
- one that sets all the switches,
  
  5525   Thu Sep 22 22:55:01 2011 AnamariaUpdateLSCPOX channel = POY PD connected + Bad Rack Keiko, Anamaria
We decided we needed a DC channel
to sense the gain in the PRC, so we set to
 RFPDpowerRack2.pdf 
  5545   Mon Sep 26 15:15:45 2011 AnamariaUpdateLSCRealignment of REFL / Some 3f PRMI locking / Recycling GainA few comments on REFL table alignment
and REFL165.
Last time we realigned the table
  
  7146   Fri Aug 10 17:17:41 2012 Alex Masha DenUpdatePEMclassify seismic c codeDen and I installed a module in the c1pem
model which has a feedforward neural network
to classify seismic disturbance (10 means
  
  2075   Fri Oct 9 14:23:53 2009 Alex IvanovConfigurationDAQtpchn mystery"Yes. This master file is used."

  
  4779   Thu Jun 2 10:19:37 2011 Alex IvanovSummaryDAQinstalled new daqd (frame builder) program on fb (target/fb/daqd)I hope that new daqd code will fix the
problem with non-aligned at 16 seconds frame
file GPS times.
  
  6094   Fri Dec 9 14:33:16 2011 Alex IvanovUpdateAdaptive FilteringC1OAF

    

       
            
  
  8859   Tue Jul 16 17:02:41 2013 Alex ColeConfigurationElectronicsAS Table Additions [Eric, Alex]
We added our reference photodetector
(Newport 1611, REF DET) to the southern edge
 photo_1_(1).JPGphoto_2_(2).JPG 
  8862   Wed Jul 17 11:13:36 2013 Alex ColeConfigurationElectronicsAS Table Additions[Eric, Alex]
For the RFPD frequency response project,
we routed the fiber that will connect our
 photo_(1).JPG 
  8863   Wed Jul 17 16:15:42 2013 Alex ColeConfigurationElectronicsAS Table Additions[Eric, Alex]
We decided that the POY Table would
be a better home for our REF DET (Newport
 photo_1_(3).JPGphoto_2_(3).JPGphoto_3.JPG 
  8870   Thu Jul 18 15:34:15 2013 Alex ColeUpdateElectronicsPD Frequency Response Update [Eric, Alex]
Our RF Switch arrived today, and
we mounted it in rack 1Y1 (1st attachment). 
 photo_3_(1).JPGphoto_1_(4).JPGphoto_2_(4).JPG 
  8940   Tue Jul 30 16:21:46 2013 Alex ColeUpdateElectronicsPhotodetector Input Modulation [Eric, Alex]
We successfully used our system to
modulate the input to a single photodetector.
  
  8947   Wed Jul 31 17:02:17 2013 Alex ColeUpdateElectronicsPreliminary Photodetector Frequency Reponse Measurements[Eric, Alex]
We used our setup from yesterday
(elog #8940) to measure transimpedance measurements
 REFL11.jpgREFL33.jpgREFL55.jpgAS55.jpg 
  8955   Thu Aug 1 18:55:20 2013 Alex ColeUpdateElectronicsPreliminary Photodetector Frequency Reponse Measurements

    

       
            
 POX11.jpgPOX11fit.jpg 
  8971   Tue Aug 6 12:43:23 2013 Alex ColeConfigurationElectronicsAS Table and Rack 1Y1 AdditionsFor the photodetector frequency response
project, I finished the construction of our
baluns chassis and mounted it in rack 1Y1
 photo_1_(5).JPGphoto_2_(5).JPG 
  8979   Wed Aug 7 15:51:53 2013 Alex ColeConfigurationElectronicsRF Switch ChangeFor the photodetector frequency response
project, our new RF Switch Chassis (NI pxie-1071)
arrived today. I took the switches out of
 photo_(2).JPG 
  9004   Tue Aug 13 11:40:19 2013 Alex ColeSummaryElectronicsRFPD Demod Filter Frequency Response Measurement For the RF PD Frequency Response
Measurement project, we get each PD signal
from the "PD RF Mon" output of
 photo_(3).JPGtest.jpg 
  9005   Tue Aug 13 11:54:40 2013 Alex ColeHowToElectronicsRF PD Fiber-Coupled Laser OperationThis post pertains to the fiber-coupled
diode laser mounted in rack 1Y1.
To turn the laser on, first turn
 photo_(4).pdf 
  9006   Tue Aug 13 13:30:41 2013 Alex ColeConfigurationElectronicsCable Routing I routed cables (RG405 SMA-SMA) from
several demodulator boards in rack 1Y2 to
the RF Switch in rack 1Y1 using the overhead
 photo_(6).JPG 
  9059   Fri Aug 23 21:01:38 2013 Alex ColeHowToElectronicsAutomated Photodetector Frequency Response System This post describes how to use the
Automated Photodetector Frequency Response
System.
  
  8795   Wed Jul 3 11:07:17 2013 AlexSummary Photodetector Characterization [Alex, Koji]
We characterized Koji's BBPD
MOD for REFL165 (see attachment).
 BBPD_PCB.pdftransimpedance_measurement.pdf 
  8806   Mon Jul 8 16:27:49 2013 AlexUpdate Planned rack additionsAlex and Eric
For the photodetector frequency response
automation project, we plan to add modules
 Annotated_Rack_1y1.pdf 
  8829   Thu Jul 11 12:00:50 2013 AlexUpdate Planned rack additions[Eric, Alex]
We mounted our Laser Module and Laser
Power Source in rack 1y1. We plan to add
 Annotated_Rack_1y1_-_update.pdf 
  8849   Mon Jul 15 16:44:46 2013 AlexUpdateOMCOMC North Safety [Eric Alex]
We are planning on testing our laser
module soon, so we have added aluminum foil
 photo_2_(1).JPG 
  8850   Mon Jul 15 16:51:37 2013 AlexConfiguration Planned AS Table addition [Eric, Alex]
We are planning to add our reference
PD to the southern third of the AS Table
 AS_Table_Ref_PD_Addition.pdf 
  1947   Tue Aug 25 23:16:09 2009 Alberto, ranaConfigurationComputerselog moved in to the cvs pathIn nodus, I moved the elog from /export
to /cvs/cds/caltech. So now it is in the
cvs path instead of a local directory on
  
  2887   Thu May 6 17:47:01 2010 Alberto, kiwamu, Jc The 3rd (aka The Drigg)OmnistructureTMIMinutes from the Lab Organization Commitee meetingToday we met and we finally come up with
a lot of cool, clever, brilliant, outstanding
ideas to organize the lab.
  
  3049   Fri Jun 4 11:32:51 2010 Alberto, kiwamuUpdateIOOMC MMT1 Mirror Tests[Alberto, Kiwamu]
Last Wednesday,
we measured the beam profile after the MC
mode matching telescope n.1 (MMT1). We found
 MCMMT1spareOpticsTestSetup.png 
  1193   Thu Dec 18 19:15:54 2008 Alberto, YoichiConfigurationSUSMode Cleaner Cavity Alignment[quote]This morning I found the MC locked
to the 10 mode. When I locked it on the 00
mode, it was unstable and eventually it always
  
  1195   Fri Dec 19 11:29:16 2008 Alberto, YoichiConfigurationMZMZ Trans PDLately, it seems that the matching of the
input beam to the Mode Cleaner has changed.
Also, it is drifting such that it has become
  
ELOG V3.1.3-