40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 333 of 350  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  5357   Wed Sep 7 12:03:49 2011 steveUpdateVACPump down has startedJamie and Steve
We closed ITMX and ITMY chambers
and started pumping around 11am
  
  5358   Wed Sep 7 13:28:25 2011 steveSummaryCamerasAll Camera setups a need upgrading


   
        
            
  
  5361   Wed Sep 7 18:19:37 2011 steveHowToVACstop pump down for overnight


   
        
            
  
  5365   Thu Sep 8 10:50:44 2011 steveUpdateVACpumpdown #71 comletedVacuum status:  " vacuum normal"  
CC1 pressure 5e-5 Torr
Slow roughing through butterfly valve
 pd#71.jpgmaglevpd.jpg 
  5366   Thu Sep 8 13:20:07 2011 steveUpdatePEMvac envelope at atm for 36 daysWe tried not to open chambers above 10,000
particles of 0.5 micron cf/min
New items going in:      
 vent70.jpg 
  5395   Tue Sep 13 16:57:44 2011 steveUpdateLSCITMX oplev **

    

       
            
  
  5403   Wed Sep 14 07:51:20 2011 steveUpdateSUSPRM damping restoredThe PRM damping was restored at side sensor
var 1050
  
  5407   Wed Sep 14 15:05:52 2011 steveUpdatePEMair cond maintenance Jeff has changed our AC filters inside
the lab this morning. Now he is checking
on the main filters at CES.  He will
 ac1y.jpg 
  5415   Thu Sep 15 07:28:08 2011 steveUpdateSUSPRM damping restored


   
        
            
  
  5434   Fri Sep 16 16:07:28 2011 steveUpdateSAFETYvisitors safety trainingPaul, Mirko and Katrin visiting grad students
received the 40m basic safety training.
 P1080241.JPG 
  5497   Wed Sep 21 11:35:07 2011 steveUpdateVACRGA scanRGA scan with maglev pumping speed at day
14 of the pump down.
The larger inserted box contains
 rgascanpd71m14d.jpg 
  5529   Fri Sep 23 16:25:01 2011 steveUpdateVACvac rack UPS battery replacedAPC Smart -UPS 2200   model: SUA2200RM2U
  batteries were replaced by compatible
RBC43, 8x  12V5A
 P1080252.JPGP1080254.JPG 
  5542   Mon Sep 26 11:35:44 2011 steveUpdateCamerasarms cameras upgradedThe arm's CCD cameras were reset as picture
shows last week.
The height adjustment only works
 P1080251.JPG 
  5562   Wed Sep 28 07:36:41 2011 steveUpdateSUSITMY damping restoredITMY suspention damping restored   
  5563   Wed Sep 28 07:46:42 2011 steveUpdateSUSDsub connections at the back of 1X5 are fixed 
 I'm turning  the sus damping 
off for Dsub connection fix at  the
  
  5587   Fri Sep 30 17:01:29 2011 steveUpdateSUSETMX oplev intensity effect on noiseKiwamu and Steve,
This is one of the better oplev set
up we have. Single bounce from TM, no mirror
 ETMXoplintens.jpgP1080267.JPG 
  5599   Mon Oct 3 08:38:21 2011 steveSummaryVACRecovery from the power shutdown is completed 
I failed to start Rana's favorit
anciant desktop computer at the vac rack.
 poweroutage.jpg 
  5610   Tue Oct 4 07:51:36 2011 steveUpdateCDSc1lsc and c1sus are still down 
 c1lsc and c1sus are still down.
Only ETMX and ETMY are damped
  
  5620   Wed Oct 5 11:33:25 2011 steveUpdateSUSPRM and BS oplev laser replaced 
JDSU 1103P died after 4 years of
service. It was replaced with new identical
  
  5622   Wed Oct 5 17:08:49 2011 steveUpdateSUSBS oplev spectraKiwamu and Steve,
The He/Ne oplev shows no coherece
so relative intensity noise is not limiting
 BSoplservON2.png 
  5630   Fri Oct 7 14:04:48 2011 steveUpdateSUSHe/Ne intensity noise effect on oplevsThe SRM bounce peak 18.33 Hz. Suresh helped
me to retune filter through Foton, but we
failed to remove it.
 7x 
  5645   Mon Oct 10 16:32:18 2011 steveUpdateSUSUL sensor of ETMY is recovered I lost UL osem voltage this morning
when I was checking the actual connection
at rack ETMY
 ETMY_UL.pngETMY_OSEM_UL.pngnoisyETMY_UL.png 
  5655   Wed Oct 12 08:43:30 2011 steveUpdateSUSITMX oplev improved a bit Atm2 is before optical path adjustment.
The idea was to remove possible clipping
in vacuum.
 ITMXoplev.pngITMXoplevservo_ON.png 
  5660   Thu Oct 13 14:23:09 2011 steveUpdateSUSITMX oplev with 3 mm beam on qpd I replaced the JDSU-Uniphase 1125P
by 1103P He/Ne laser. This new laser had
2.8 mW output yesterday. It degraded to 0.5
 ITMXoplev1103p#2.pngITMXoplev.png 
  5675   Mon Oct 17 07:57:24 2011 steveUpdateSUSETMX sus damping restored    
  5680   Mon Oct 17 17:07:30 2011 steveUpdateSUSETMX oplev returning beam od 3 mm ETMX oplev had 6 mm diameter beam
on the qpd.  I relayed the beam path
with 2 lenses  to get back  3 mm
 ETMX-oplev.jpg 
  5692   Wed Oct 19 08:34:16 2011 steveUpdateSUSSRM sus damping restoredSorry Kiwamu, I realized too late that
you were freeswigging. Hopefully 4 hrs was
enough.
 SRM.png 
  5693   Wed Oct 19 09:44:10 2011 steveUpdateSUSETMX oplev power spectrum


   
        
            
 ETMXoplev2lens.png 
  5701   Wed Oct 19 16:28:35 2011 steveUpdateGreen LockingETMY mechanical shutter is working


   
        
            
  
  5712   Thu Oct 20 12:43:19 2011 steveUpdateSAFETYrefilled first aid kits & their locationsFirst aid kits are located close vicinity
of entry doors and under circuit breaker
panels.
 8x 
  5719   Fri Oct 21 09:08:33 2011 steveUpdateSUSMC2 Misalignment Thinks to do before the NEXT realignment:
B,  tie 4 ancher bolts on table
legs to the floor
 mc2.jpg 
  5720   Fri Oct 21 10:32:14 2011 steveUpdatePSLPSL laser turned offIn order to move the emergency shut off
switch in room 103 I had to turn off the
2 W Innolight laser. This job will take an
  
  5721   Fri Oct 21 11:02:47 2011 steveUpdatePSLPSL laser turned ON


   
        
            
 laserofon.png 
  5728   Mon Oct 24 14:26:01 2011 steveUpdateGeneralno electricity on Nov. 19
    
       

            
  
  5741   Wed Oct 26 10:07:16 2011 steveUpdateGeneralno electricity ....... will be recheduled

    

       
            
  
  5759   Fri Oct 28 18:33:59 2011 steveUpdateVACleaking nitrogen line fixedI was lucky to notice that the nitrogen
supply line to the vacuum valves was leaking.
Closed ALL valves. Open supply line to atm.
 allvalvesclosed.png 
  5767   Mon Oct 31 08:55:19 2011 steveUpdateVACpressure plot at day 53


   
        
            
 pd71-m-d53.png 
  5768   Mon Oct 31 09:42:12 2011 steveUpdateIOOPMC lockedThe PMC HV drops off more offen lately.  pmcHV.png 
  5771   Mon Oct 31 15:58:25 2011 steveUpdateSUSthinking of black glass baffles for 40mShade 12 black glass-green lines: 1/8"
thick,  6" wide  x 7 "
high  mounted on angle bracket below. 
 03260901.PDF03260902.PDF 
  5782   Wed Nov 2 10:04:05 2011 steveUpdateSUSMC2 chamber anchoring tightened


   
        
            
  
  5783   Wed Nov 2 10:41:47 2011 steveUpdateGeneral2 spare heliax at the LSC rackThey were traced and labeled. One goes
to 1X2 and the other to AS-ISCT. They are
Andrew Heliax 1/4" od. made by CommScone, 
  
  5826   Mon Nov 7 08:08:24 2011 steveUpdateIOOPMC lockedThe PMC acted like it was sleeping. The
HV slider was dead. The MC locked instantly
as the PMC had transmission.
 pmcHV.png 
  5827   Mon Nov 7 08:25:15 2011 steveUpdateGeneralno electricity on Nov. 20The
Nov.19 interruption was rescheduled to be
on Nov.20,2011
  
  5831   Mon Nov 7 14:58:17 2011 steveUpdateGeneralChamber illuminator remote switches installed

    

       
            
  
  5844   Wed Nov 9 07:57:39 2011 steveUpdateSUSETMX oplev is down and sus damping restoredThe ETMX oplev returning beam is well centered
on the qpd. We lost this signal 2 days ago.
I will check on the qpd. 
 etmxtripped.pngetmxOpl.png 
  5887   Mon Nov 14 15:46:14 2011 steveUpdateVACTP2's forepump changedThe foreline pressure of TP2 was 1.4 Torr
this morning. This drypump worked well for
ten months.
 drypump.png 
  5897   Tue Nov 15 16:16:34 2011 steveUpdatePSLenclosure interlocks are working on all sliding doorsBen and Sam came over to fix one of 
the east side  sliding  door sensor
that had to be moved from the inside 
  
  5898   Tue Nov 15 16:25:38 2011 steveUpdatePSLIOO angle qpd centeredThis moring I centered the IOO Angle QPD.
The IOO Pos QPD was not centered. The existing
layout does not allow the beam centering
  
  5907   Wed Nov 16 10:11:20 2011 steveUpdatePSLIOO angle & pos qpd centered


   
        
            
 iooqpds.png 
  5909   Wed Nov 16 10:25:57 2011 steveUpdateSUSPRM damping restoredThe  PRM lost damping about a day
ago. It was restored.
  
ELOG V3.1.3-