ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
13858
|
Thu May 17 13:51:35 2018 |
Jon Richardson | Configuration | Electronics | Documentation & Schematics for AUX-PSL PLL | [Jon, Gautam]
Attached is supporting documentation
for the AUX-PSL PLL electronics installed |
|
13863
|
Fri May 18 14:18:03 2018 |
gautam | Configuration | Electronics | Basic MEDM Control Screen setup | I setup a basic MEDM screen for remote
control of the PLL.
The Slow control voltage slider |
|
13867
|
Fri May 18 19:59:55 2018 |
Jon Richardson | Configuration | Electronics | AUX-PSL PLL Characterization Measurements | Below is analysis of measurements
I had taken of the AUX-PSL PLL using an SR560
as the servo controller (1 Hz single-pole |
 |
13873
|
Mon May 21 15:34:19 2018 |
gautam | Configuration | Electronics | Channel hijacking history | Since we've been hijacking channels
like there is no tomorrow for the AUX-PLL
setup, I'm documenting the channel names |
|
13876
|
Tue May 22 10:14:39 2018 |
Jon Richardson | Configuration | Electronics | Documentation & Schematics for AUX-PSL PLL |
|
|
13881
|
Wed May 23 00:45:18 2018 |
johannes | Configuration | General | AS port laser injection | I was planning to set up the additions
to the AS table that are outlined in Attachment
#1. Unfortunately the beam is too large for |
|
13886
|
Thu May 24 13:06:17 2018 |
gautam | Configuration | ALS | DFD noises | Summary:
The DFD noise floor is
~0.5Hz/rtHz |
 |
13889
|
Thu May 24 19:41:28 2018 |
gautam | Configuration | ALS | BeathMouth reinstalled on PSL table | Summary:
DC light power incident
on beat PD is |
|
13890
|
Thu May 24 20:31:03 2018 |
gautam | Configuration | ALS | DFD noises | A
couple of months ago, I took 21 measurements
of the delay line transfer function. As shown |
 |
13891
|
Fri May 25 13:06:33 2018 |
Jon Richardson | Configuration | Electronics | Improved Measurements of AUX-PSL PLL | Attached are gain-variation measurements
of the final, in situ AUX-to-PSL phase-locked
loop (PLL). |
 |
13906
|
Thu May 31 22:59:27 2018 |
Koji | Configuration | Computers | Shorewall on nodus | [Jonathan Koji]
Shorewall (http://shorewall.net/),
a tool to configure iptables, was installed |
|
14020
|
Tue Jun 26 17:20:33 2018 |
Jon | Configuration | Cameras | LLO Python Camera Software is Working | Thanks to a discussion yesterday with Joe
Betzweiser, I was able to identify and fix
the remaining problem with the LLO GigE camera |
|
14026
|
Wed Jun 27 19:37:16 2018 |
Koji | Configuration | Computers | New NAT router installed | [Larry, Koji]
We replaced the NAT router between
martian and the campus net. We have the administrative |
|
14033
|
Fri Jun 29 18:16:32 2018 |
Jon | Configuration | PSL | Changes to AUX Optical Layout on PSL Table | In order to use the 0th-order deflection
beam from the AOM for cavity mode scans,
I've coaligned this beam to the |
|
14041
|
Fri Jul 6 12:12:09 2018 |
Annalisa | Configuration | Thermal Compensation | Thermal compensation setup | I tried to put together a rudimentary heater
setup.
As a heating element, I used the |
   |
14043
|
Sat Jul 7 19:50:38 2018 |
Annalisa | Configuration | Thermal Compensation | Study about the Thermal projection setup and its effect on the cavity | I made some simulation to study the change
that the heater setup can induce on the Radius
of Curvature of the ETM. |
6x |
14050
|
Tue Jul 10 23:44:23 2018 |
Annalisa | Configuration | Thermal Compensation | Heater setup assembly | [Annalisa, Koji]
Today both the heater and the reflector
were delivered, and we set down the setup |
8x |
14062
|
Fri Jul 13 00:15:13 2018 |
Annalisa, Terra | Configuration | AUX | Y arm cavity scan | [Annalisa, Terra, Koji, Gautam]
Summary: We
find a configuration for arm scans which |
 |
14071
|
Fri Jul 13 23:39:46 2018 |
Annalisa | Configuration | Thermal Compensation | Thermal compensation setup - power supply | [Annalisa, Rana]
In order to power the heater setup
to be installed in the ETMY chamber, |
  |
14078
|
Tue Jul 17 17:37:46 2018 |
Annalisa, Terra | Configuration | Thermal Compensation | Heaters installation | Summary
We
installed two heaters setup on the ETMY bench
in order to try inducing some radius of curvature |
6x |
14091
|
Fri Jul 20 18:30:47 2018 |
Jon | Configuration | AUX | Recommend to install AUX PZT driver | I recently realized that the PLL is only
using about 20% of the available actuation
range of the AUX PZT. The +/-10 V control |
|
14104
|
Wed Jul 25 22:46:15 2018 |
gautam | Configuration | Computers | NDS access from outside | After this work, I've been having some
trouble getting data with Python NDS. Eventually,
I figured out that the nds connection request |
|
14153
|
Fri Aug 10 11:29:39 2018 |
aaron | Configuration | Upgrade | Parts list for BHD | I've started putting together a list
of things we'll need to buy to do BHD
readout. I'm still messing around with |
|
14154
|
Fri Aug 10 16:43:50 2018 |
gautam | Configuration | Upgrade | Parts list for BHD | Can we use the leakage
beam from MMT2 on the OMC table as the
LO beam? I can't find the spec for this |
|
14155
|
Sun Aug 12 10:59:34 2018 |
aaron | Configuration | Upgrade | Parts list for BHD | That seems fine, I wasn't thinking
of that beam. in that case could we just
have a PBS directly behind MMT2 and send |
|
14158
|
Mon Aug 13 17:20:07 2018 |
aaron | Configuration | Upgrade | Parts list for BHD | I've attached the diagram of what I
mean.
There are a couple caveats and |
|
14205
|
Fri Sep 21 09:59:09 2018 |
yuki | Configuration | ASC | Y end table upgrade plan | [Yuki, Gautam]
Attachments #1 is the current setup
of AUX Y Green locking and it has |
    |
14212
|
Sun Sep 23 19:32:23 2018 |
yuki | Configuration | ASC | Y end table upgrade plan | [ Yuki, Gautam ]
The setup I designed before has
abrupt gouy phase shift between two steering |
    |
14214
|
Mon Sep 24 11:09:05 2018 |
yuki | Configuration | ASC | Y end table upgrade plan | [ Yuki, Steve ]
With Steve's help, we checked
a new lens can be set soon after dichroic |
|
14216
|
Tue Sep 25 18:08:50 2018 |
yuki | Configuration | ASC | Y end table upgrade plan | [ Yuki, Gautam ]
We want to remotely control steeing
PZT mirrors so its driver is needed. |
|
14218
|
Thu Sep 27 14:02:55 2018 |
yuki | Configuration | ASC | PZT driver board verification | [ Yuki, Gautam ]
I fixed the input terminal that
had been off, and made sure PZT driver |
    |
14219
|
Sun Sep 30 20:14:51 2018 |
yuki | Configuration | ASC | QPD calibration | [ Yuki, Gautam, Steve ]
Results:
I calibrated a QPD (D1600079, V1009) |
 |
14220
|
Mon Oct 1 12:03:41 2018 |
not yuki | Configuration | ASC | PZT driver board verification | I assume this QPD set is a D1600079/D1600273
combo.
How much was the SUM output during |
|
14221
|
Mon Oct 1 13:33:55 2018 |
yuki | Configuration | ASC | QPD calibration |
Quote:
|
|
14222
|
Mon Oct 1 20:39:09 2018 |
gautam | Configuration | ASC | c1asy | We need to set up a copy of the c1asx |
|
14224
|
Tue Oct 2 18:50:53 2018 |
yuki | Configuration | ASC | PZT mirror calibration | [ Yuki, Gautam ]
I calibrated PZT mirrors. The ROUGH
result was attached. (Note that some errors and |
   |
14226
|
Wed Oct 3 14:24:40 2018 |
yuki | Configuration | ASC | Y end table upgrade plan | Interim Procedure Report:
Purpose
The current setup of AUX Y-arm |
|
14227
|
Wed Oct 3 18:15:34 2018 |
yuki | Configuration | ASC | AI board improvement | [ Yuki, Gautam ]
I improved Anti-Imaging board (D000186-Rev.D),
which will be put between DAC port and |
|
14228
|
Thu Oct 4 00:44:50 2018 |
yuki | Configuration | ASC | AI board improvement | [ Yuki, Gautam ]
I made a cable which connects DAC
port (40 pins) and AI board (25 pins). I |
|
14230
|
Thu Oct 4 22:15:30 2018 |
yuki | Configuration | ASC | Y-end table upgrade | Before changing setup at Y-end table, I
measured the status value of the former setup
as follows. These values will be compared |
  |
14231
|
Fri Oct 5 00:46:17 2018 |
Koji | Configuration | ASC | Y-end table upgrade | ???
The SHG crystal has the conversion
efficiency of ~2%W (i.e. if you have 1W input |
|
14232
|
Fri Oct 5 17:32:38 2018 |
yuki | Configuration | ASC | Y-end table upgrade | I measured it with the wrong setting of
a powermeter. The correct ones are here:
beam power going into doubling |
|
14233
|
Fri Oct 5 17:47:55 2018 |
gautam | Configuration | ASC | Y-end table upgrade | What
about just copying the Xend |
|
14234
|
Fri Oct 5 22:49:22 2018 |
yuki | Configuration | ASC | Y-end table upgrade | I designed a new layout. It has good mode-matching
efficiency, reasonable sensitivity to component
positions, good Gouy phase separation. I'm |
|
14235
|
Sun Oct 7 16:51:03 2018 |
gautam | Configuration | LSC | Yarm triggering changed | To facilitate Yuki's alignment of the
EY green beam into the Yarm cavity, I have changed |
|
14236
|
Sun Oct 7 22:30:42 2018 |
yuki | Configuration | LSC | Yarm Green locking was recovered | I finished installation of optics in the
Y-end and recovered green locking. Current
ALS-TRY_OUTPUT is about 0.25, which is lower |
 |
14237
|
Mon Oct 8 00:46:35 2018 |
yuki | Configuration | ASC | Y-end table upgrade |
Quote:
|
|
14238
|
Mon Oct 8 18:56:52 2018 |
gautam | Configuration | ASC | c1asx filter coefficient file missing | While pointing Yuki to the c1asx servo
system, I noticed that the filter
file for c1asx is missing in the usual chans |
|
14239
|
Tue Oct 9 16:05:29 2018 |
gautam | Configuration | ASC | c1tst deleted, c1asy deployed. | Setting up c1asy:
Backed up old c1tst.mdl
as c1tst_old_bak.mdl in /opt/rtcds/userapps/release/cds/c1/models
Copied |
|
14240
|
Tue Oct 9 23:03:43 2018 |
yuki | Configuration | LSC | Yarm Green locking was recovered | [ Yuki, Gautam, Steve ]
To align the green beam in Y-end
these hardware were installed: |
 |