40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 333 of 344  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Datedown Author Type Category Subject Text Attachments
  602   Mon Jun 30 13:48:47 2008 John, RobConfigurationPSLDon't put the bin in front of the air conditioning unitWe spotted that the laser power was dropping.

[SIZE=5][COLOR=blue][FONT=Verdana]The air
 binremoval.png 
  601   Mon Jun 30 09:46:15 2008 JohnUpdateIOOMC WFSMC WFS are on. They seem to do some good during
the day.
  
  600   Mon Jun 30 08:59:23 2008 steveUpdateIOOIOO-MC_DEMOD_LO is lowThe alarm handler is beeping relentlessly:
asking for help in high partical count and
low demod signal
 demlo.jpg_____ 
  599   Mon Jun 30 05:33:38 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Optical setup (II)o The position of the iris was adjusted so
as not to disturub the beam for OMCR CCD.
  
  598   Mon Jun 30 01:49:06 2008 JohnUpdateIOOMC workI'm in the process of aligning the mode cleaner/
input beam.
  
  597   Sun Jun 29 20:29:48 2008 ranaUpdatePSLCorrelation of PSL SLOW control v. Room temperature   slowtemp.png 
  596   Sun Jun 29 20:09:40 2008 JohnSummaryIOOmcup and mcdown indicatorsI edited the mcup and mcdown scripts so that
C1IFO_STATE shows when these scripts are
running.
 mcscreen.pngifostate.png 
  595   Sun Jun 29 19:53:26 2008 JohnSummaryPSLISS[quote]I reduced the gain of the ISS (C1:
PSL-ISS_VGAGAIN) from 5dB to 2dB. Any higher
and it constantly saturates.[/quote]
  
  594   Sun Jun 29 19:19:47 2008 ranaSummaryIOOTrends of the PSL/IOO Quads over 1000 daysOnly IOO POS has been working for the past
2 years. I guess we should recommission the
IOO ANG and REFL QPDs
 a.png 
  593   Sun Jun 29 18:58:43 2008 ranaSummaryComputers1e20 is too big for AWG and/or IOVMEWhile testing out my matlab/awgstream based
McWFS diagnostic script I accidentally put
a
  
  592   Sun Jun 29 14:53:02 2008 robUpdateComputersRebooting[quote]All of the computers are now showing
green lights.
  
  591   Sun Jun 29 11:31:52 2008 JohnSummaryPSLISSI reduced the gain of the ISS (C1: PSL-ISS_VGAGAIN)
from 5dB to 2dB. Any higher and it constantly
saturates.
  
  590   Sun Jun 29 02:33:28 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Optical setup (I)I have constructed the beam injection optics
for the abs length measurement.
 optical_configuration.pngoptical_layout_ap_table2.pngoptical_layout_ap_table2.pdf 
  589   Sat Jun 28 23:23:50 2008 JohnUpdateComputersRebootingAll of the computers are now showing green
lights.
  
  588   Sat Jun 28 14:56:44 2008 JohnUpdateComputersini filesIn short, I was editing the ini files yesterday
evening, I didn't e-log it and after some
investigation this afternoon it apears
  
  587   Sat Jun 28 03:10:25 2008 robUpdateComputersc1iovme[quote]C1susvme2 and C1iovme crashed which
sent the optics swinging and tripped the
watchdogs.
  
  586   Fri Jun 27 19:59:44 2008 JohnUpdateComputersc1iovmeC1susvme2 and C1iovme crashed which sent the
optics swinging and tripped the watchdogs.
  
  585   Fri Jun 27 18:21:01 2008 JenneUpdateElectronicsResponse of the LO input on the MC demod boardThe alarm handler has been flipping out saying
that the LO input of the MC's demod board
is too low, so at Rana's suggestion, Eric
  
  584   Fri Jun 27 18:03:46 2008 JenneUpdateElectronicsAnother bad cable in the MC servoEric was helping me to measure the response
of the LO input on the MC's Demod board,
and when we disconnected the end of the cable
  
  583   Fri Jun 27 15:20:52 2008 robDAQLSC.ini file change
I removed C1:LSC-XARM_CTRL from the frames
and added C1:LSC-CARM_ERR
  
  582   Fri Jun 27 14:36:39 2008 JohnSummaryLocking Rob, Yoichi, John

Some progress last night:
 gettingcloser.png 
  581   Fri Jun 27 09:20:15 2008 steveFrogsPEMdust particle count is up & alarm handler is onThis 3 years plot show the trend of seasons.
When outside air quality goes bad ( 0.5 micron
> 1 million ) the lab follows.
 dust3y.jpg 
  580   Thu Jun 26 22:08:33 2008 JenneUpdateElectronics3.7MHz bandstop filter in MC Servo The 3.7MHz elliptical bandstop filter that
I made during my SURF summer is now installed
in the MC servo loop to reduce the noise
 MCLoopGainBoth.pngTP1ASpectrumBoth.pngQmonWithFilt.pngMCOut2WithFilt.png 
  579   Thu Jun 26 21:07:11 2008 ranaConfigurationASSdust & MC1I realized today, that yesterday while we
were trying to debug the adaptive noise canceler,
I turned
 Screenshot-2.png 
  578   Thu Jun 26 20:59:22 2008 ranaUpdateComputer Scripts / ProgramsAlarm Handler[COLOR=red][SIZE=5][B]Please do not turn off
the Alarm Handler on op540m.[/B][/SIZE][/COLOR]
  
  577   Thu Jun 26 18:29:44 2008 JenneUpdate MC Back onlineJenne, Rob, Yoichi

I was playing with the Mode Cleaner earlier
  
  576   Thu Jun 26 18:27:04 2008 ranaUpdateComputer Scripts / ProgramsNo Dataviewer No CryDataviewer was hanging. It would open the
Grace window but then not plot anything.
Since DTT was working
  
  575   Thu Jun 26 18:24:28 2008 YoichiUpdatePSLFSS input ofset slider problem - fixedI checked the FSS servo interface board and
found that a LT1125CSW used to differentialize
offset channel was broken (no virtual short).
  
  574   Thu Jun 26 14:06:00 2008 MashaUpdateGeneral500mW INNOLIGHT NPRO infoBelow is the placement of 500mW INNOLIGHT
NPRO mephisto laser. It is set up on the
Symmetric Port table. [IMG]elog:574/1[/IMG]
 500mW_NPRO.JPG 
  573   Thu Jun 26 12:30:40 2008 JohnSummaryLockingCARM on REFL_DC[COLOR=blue]Idea:[/COLOR]

Try REFL_DC as the error signal for CARM
  
  572   Thu Jun 26 10:56:15 2008 Max JonesUpdatePEMRemoved MagnetometerI removed the Bartington Magnetometer on the
x arm to one of the outside benches. I'll
be trying to determine if and how it works
  
  571   Thu Jun 26 01:10:18 2008 ranaUpdatePEMAlarm Handler indicates that dust level is high[I]In its first useful act[/I], the Alarm
Handler started beeping indicating that the
[COLOR=purple]dust particle
 Untitled.png 
  570   Thu Jun 26 01:08:22 2008 ranaConfigurationGeneralAlarm Handler RevivedI have revived the Alarm Handler by turning
it on on op540m and adjusting the levels
of
 b.gif 
  569   Wed Jun 25 18:03:21 2008 YoichiConfigurationPSLFSS Input Offset slider problemWhile working on the PMC scanning, I noticed
that the FSS input offset slider is doing
nothing.
  
  568   Wed Jun 25 13:56:56 2008 JohnSummaryLockingTuesday night lockingRob, John

Worked to try and reduce the CARM offset
  
  567   Wed Jun 25 13:38:22 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Placement of the 700mW NPRO on the AP tableThis morning I have put the 700mW NPRO on
the AP table for the abs length measurement.
 NPRO700mW_placement.jpg 
  566   Wed Jun 25 12:25:28 2008 EricSummaryCameras2D Gaussian Fitting CodeI initially wrote a script in MATLAB that
takes pictures of the laser beam's profile
and fits them to a two dimensional gaussian
  
  565   Wed Jun 25 11:36:14 2008 Max JonesUpdateComputer Scripts / ProgramsFirst Week UpdateFor the first week I have been modifying the
noise budget script in caltech/NB to run
with 40 m parameters and data. As per Rana's
 C1_NoiseBudgetPlot_Day.epsC1_NoiseBudgetPlot_Night.eps 
  564   Wed Jun 25 11:01:45 2008 MashaUpdateAuxiliary lockingfiber stabilizationFor the first week, I have been learning about
fiber noise cancellation, auxiliary locking
techniques, and other relevant helpful topics
  
  563   Wed Jun 25 09:46:45 2008 SharonUpdate Adaptive FiltersI have been learning about different methods
for applying adaptive filters to improve
the Mode Cleaner lock in specific, and other
  
  562   Wed Jun 25 01:30:19 2008 JohnSummaryIOOFrequency noise after the MCI made some (very) rough estimates of the
contribution made to the noise after the
mode cleaner by three sources.
 MC2noise080623.png 
  561   Wed Jun 25 00:35:40 2008 KojiSummaryGeneralOptical Layout on the AP tableI have visited the AP table in order to investigate
where we are going to put the optical setup
for the abs. length meas. 
 optical_layout_ap_table.pngoptical_layout_ap_table.pdf 
  560   Tue Jun 24 22:43:23 2008 ranaSummarySEIStack TF   Screenshot.png 
  559   Tue Jun 24 22:31:10 2008 MashaUpdateAuxiliary lockingmy first step in fiber stabilizationThere is a new 1W INNOLIGHT NPRO laser at
the Symmetric Port.
  
  558   Tue Jun 24 17:12:10 2008 josephb, EricConfigurationCamerasGC750 setup, 1X4 Hub connected, ETMX imagesThe GC750 camera has been setup to look at
ETMX.  In addition, the new 1X4 rack mounted
switch (131.215.113.200) has been connected
 GC750_ETMX_E30000_single.pdfGC750_ETMX_E30000_avg.pdfGC750_ETMX_E30000_std.pdf 
  557   Tue Jun 24 15:15:09 2008 JohnSummaryLSCLocking effortsRob, Rana, John

In the past week or so we've been working
 mcl080623.png 
  556   Tue Jun 24 10:24:43 2008 KojiUpdateGeneralAbs. Len. Meas. ~ Cavity Swing Measurement (2)At the entry 555, Alberto reported the results
of the cavity length measurement using cavity
sweeping.
 armlength.pngarmlength2.png 
  555   Mon Jun 23 21:51:19 2008 AlbertoUpdateGeneralArm Cavity Length MeasurementWe measured the arm cavity lengths sweeping
the ETM mirror position and looking at the
reflected demodulated output. We excited
 40mLengthMeasure.pdf 
  554   Mon Jun 23 19:48:28 2008 rana,albertoSummaryIOOStochMon trends (80 days)Here's a StochMon plot showing the RFAM after
the MC. Remember that in these units, 2V
means no RFAM
 e.png 
  553   Mon Jun 23 19:33:01 2008 rana, jenneUpdateIOOMC_F Noise checkWe looked at the MC_F spectrum because Rob
and Yoichi said that it had gone 'all crazy'.
It
 mcf.png 
ELOG V3.1.3-