40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m elog, Page 332 of 357  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  16130   Tue May 11 16:29:55 2021 JonUpdateCDSI/O Chassis Assembly


Quote:


 Screen_Shot_2021-05-11_at_3.03.42_PM.png 
  16131   Tue May 11 17:43:09 2021 KojiUpdateCDSI/O Chassis AssemblyDid you match the local PC time with the
GPS time?
  
  16132   Wed May 12 10:53:20 2021 Anchal, PacoUpdateLSCPSL-IMC PDH Loop and XARM PDH Loop diagramAttached is the control loop diagram when
main laser is locked to IMC and a single
arm (XARM) is locked to the transmitted light
 IMC_SingleArm.pdf 
  16134   Wed May 12 13:06:15 2021 Ian MacMillanUpdateCDSSUS simPlant modelWorking with Chris, we decided that it
is probably better to use a simple filter
module as a controller before we make the
 SimplePlant_SingleContr.pdfx1sup_isolated.pdfX1SUP_ISOLATED_GDS_TP.pngX1SUP_ISOLATED_C1_SUS_SINGLE_PLANT_Plant_POS_Mod.png 
  16135   Wed May 12 14:23:20 2021 JordanUpdateSUSMass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI units   Moments_of_Inertia_SI.PNG 
  16136   Wed May 12 16:53:59 2021 KojiUpdateSUSMass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI unitsNo, this is the property of the suspension
assembly. The mass says 10kg

Could you do the same for the testmass
  
  16137   Wed May 12 17:06:52 2021 JordanUpdateSUSMass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI unitsHere are the mass properties for the only
the test mass assembly (optic, 3" ring,
and wire block). (Updated with g*mm^2)
 Moments_of_Inertia_SI.PNG 
  16138   Thu May 13 11:55:04 2021 Anchal, PacoUpdateSUSMC1 suspension misbehavingWe came in the morning with the following
scene on the zita monitor:

 Screenshot_from_2021-05-13_09-50-24.pngMC1_Glitches_Invest2.pdf 
  16139   Thu May 13 19:38:54 2021 AnchalUpdateSUSMC1 Satellite Amplifier Debugged[Anchal Koji]

Koji and I did a few tests with
an OSEM emulator on the satellite amplifier
 MC1_UL_Channel_Fixed.png 
  16140   Fri May 14 03:29:50 2021 KojiUpdateElectronicsHV Driver noise test with the new HV power supply from MatsusadaI believe I did the identical test with
the one in [40m
ELOG 15786]. The + input of PA95 was
 HV_Driver_PSD.pdf 
  16141   Fri May 14 17:45:05 2021 ranaUpdatePSLHEPA speed raisedThe PSL was too hot, so I turned on the
south HEPA on the PSL. The north one was
on and the south one was off (or so slow
  
  16142   Sat May 15 12:39:54 2021 gautamUpdatePSLNPRO tripped/switched offThe NPRO has been off since ~1AM this morning
it looks like. 
 NPRO.png 
  16143   Sat May 15 14:54:24 2021 gautamUpdateSUSIMC settings revertedI want to work on the IFO this weekend,
so I reverted the IMC suspension settings
just now to what I know work (until the new
 MC2coilOut.png 
  16144   Tue May 18 00:52:38 2021 ranaUpdatePSLHEPA speed raisedLooks like the fan lowered the temperature
as expected. Need to get a few more days
of data to see if its stabilized, or if that's
 Untitled.png 
  16145   Tue May 18 20:26:11 2021 ranaUpdatePSLHEPA speed raisedFluke. Temp fluctuations
are as usual, but the overall temperature
is still lower. We ought to put some temperature
  
  16146   Wed May 19 18:29:41 2021 KojiUpdateSUSMass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI unitsCalculation for the SOS POS/PIT/YAW resonant
frequencies

- Nominal height gap between the
 SOS_resonant_freq.pdfSOS_resonant_freq.nb.zip 
  16147   Thu May 20 10:35:57 2021 AnchalUpdateSUSIMC settings revertedFor future reference, the new settings
can be upoaded from a script in the same
directory. Run python /users/anchal/20210505_IMC_Tuned_SUS_with_Gains/uploadNewConfigIMC.py
  
  16148   Thu May 20 16:56:21 2021 KojiUpdateElectronicsProduction version of the HV coil driver tested with KEPCO HV suppliesHP HV power supply ( HP6209
) were returned to Downs
 P_20210520_154523_copy.jpg 
  16149   Fri May 21 00:05:45 2021 KojiUpdateSUSNew electronics: Sat Amp / Coil Drivers11 new Satellite Amps were picked up from
Downs. 7 more are coming from there. I have
one spare unit I made. 1 sat amp has already
 F3CDEF8D-4B1E-42CF-8EFC-EA1278C128EB_1_105_c.jpeg 
  16150   Fri May 21 00:15:33 2021 KojiUpdateElectronicsDC Power Strip delivered / storedDC Power Strip Assemblies delivered and
stored behind the Y arm tube (Attachment
1)
 9x 
  16151   Fri May 21 09:44:52 2021 Ian MacMillanUpdateCDSSUS simPlant modelThe transfer function given in the previous
post was slightly incorrect the units
did not make sense the new function is:
 Transfer_Function_of_Damped_Harmonic_Oscillator.pdf 
  16152   Fri May 21 12:12:11 2021 PacoUpdateNoiseBudgetAUX PDH loop identification[Anchal, Paco]

We went into 40m to identify where
XARM PDH loop control elements are. We didn't
  
  16153   Fri May 21 14:36:20 2021 Ian MacMillanUpdateCDSSUS simPlant modelThe plant transfer function of the pendulum
in the s domain is:

 Plant_Mod_TF.pdf 
  16154   Sun May 23 18:28:54 2021 JonUpdateCDSOpto-isolator for c1auxeyThe new HAM-A coil drivers have a single
DB9 connector for all the binary inputs.
This requires that the dewhitening switching signals
  
  16155   Mon May 24 08:38:26 2021 ChubUpdateElectronics18-bit AI, 16-bit AI and 16-bit AA- High priority units: 2x 18AI / 1x 16AI
/ 3x 16AA

All six are reworked and on the
  
  16156   Mon May 24 10:19:54 2021 PacoUpdateGeneralZita IOO stripUpdated IOO.strip on Zita to show WFS2
pitch and yaw trends (C1:IOO-WFS2_PIY_OUT16
 Screenshot_from_2021-05-24_18-09-37.png24and25_05_2021_PEM_BS_10_30.png 
  16160   Tue May 25 17:08:17 2021 ChubUpdateElectronicschassis rework complete!All remaining chasses have been reworked
and placed on the floor along the west wall
in Room 104. 
 40M_chassis_reworked_5-25-21.jpg 
  16162   Wed May 26 02:00:44 2021 gautamUpdateElectronicsCoil driver noiseI was preparing a short write-up / test
procedure for the custom HV coil driver,
when I thought of something I can't resolve.
 coilDriverTopologies.pdfshotVthermal.pdf 
  16165   Thu May 27 14:11:15 2021 JordanUpdateSUSCoM to Clamping Point Measurement for 3" Adapter RingThe current vertical distance between the
CoM and the wire clamping point on the 3"
Ring assembly is 0.33mm. That is the CoM
 CoM_to_Clamp.PNGCoM_to_Clamp_2.PNG 
  16166   Fri May 28 10:54:59 2021 JonUpdateCDSOpto-isolator for c1auxeyI have received the opto-isolator needed
to complete the new c1auxey system. I
left it sitting on the electronics bench
 optoisolator.jpeg 
  16167   Fri May 28 11:16:21 2021 JonUpdateCDSFront-End Assembly and TestingAn update on recent progress in the lab
towards building and testing the new FEs.

1. Timing problems resolved /
 c1bhd.pnggds_tp.pngteststand.jpegbench_supply.jpeg 
  16169   Tue Jun 1 14:26:23 2021 JordanUpdateSUSCoM to Clamping Point Measurement for 3" Adapter RingAfter changing the material of the Balance
Mass from 6061 Al to 304 Steel, and changing
the thickness to 0.21" from 0.25".
 CoM_to_Clamp_Updated.PNG 
  16170   Tue Jun 1 16:17:06 2021 YehonathanUpdateBHDSOS assemblyI tried to push the clean Viton tips into
the vented screws just to find out that the
vented holes are too small. We need to drill
  
  16172   Wed Jun 2 01:03:19 2021 KojiUpdateBHDSOS assemblyCan you just cut the viton tips smaller?
If you cut it to have some wedge (or say,
taper), it can get stuck with the vent hole.
  
  16173   Wed Jun 2 01:08:57 2021 KojiUpdateSUSCoM to Clamping Point Measurement for 3" Adapter RingHow about to use the non-Ag coated threaded
shaft + the end SS masses with helicoils
inserted? Does this save the masses to get
  
  16176   Wed Jun 2 17:50:50 2021 PacoUpdateEquipment loanBorrow red cartI borrowed the little red cart 🛒
to help clear the path for new optical tables
in B252 West Bridge. Will return once I am
 IMG_20210602_172858.jpg 
  16177   Thu Jun 3 13:06:47 2021 Ian MacMillanUpdateCDSSUS simPlant modelI was able to measure the transfer function
of the plant filter module from the channel X1:SUP-C1_SUS_SINGLE_PLANT_Plant_POS_Mod_EXC
to X1:SUP-C1_SUS_SINGLE_PLANT_Plant_POS_Mod_OUT.
 SingleSusPlantTF.pdfSUS_PLANT_TF.zip 
  16178   Thu Jun 3 17:15:17 2021 YehonathanUpdateCDSOpto-isolator for c1auxeyAs Jon wrote we need to use the NPN configuration
(see attachments). I tested the isolator
channels in the following way:
 Optical_Isolator_NPN_Input.pngOptical_Isolator_NPN_Output.png 
  16180   Thu Jun 3 17:49:46 2021 PacoUpdateEquipment loanBorrow red cartReturned today.




  
  16181   Thu Jun 3 22:08:00 2021 KojiUpdateCDSOpto-isolator for c1auxey- Could you explain what is the blue thing
in Attachment 1?

- To check the validity of the
  
  16182   Fri Jun 4 14:49:23 2021 YehonathanUpdateCDSOpto-isolator for c1auxeyI made a diagram (Attached). I think it
explains the blue thing in the previous post.

I don't know what is the grounding
 Optical_isolator_Wiring.pdf 
  16183   Fri Jun 4 17:46:25 2021 unYehonathanUpdateCDSOpto-isolator for c1auxeyI mounted the optoisolator on the DIN rail
and connected the 3 first channels
 20210604_173420.jpg 
  16184   Sun Jun 6 03:02:14 2021 KojiUpdateCDSOpto-isolator for c1auxeyThis RTS also use the BO interface with
an opto isolator. https://dcc.ligo.org/LIGO-D1002593

Could you also include the pull
  
  16185   Sun Jun 6 08:42:05 2021 JonUpdateCDSFront-End Assembly and TestingHere is an update and status report on
the new BHD front-ends (FEs).

Timing

The changes
 c1bhd.png16bit_dacs.pngmyricom.png 
  16186   Sun Jun 6 12:15:16 2021 JonUpdateCDSOpto-isolator for c1auxeySince this Ocean Controls optoisolator
has been shown to be compatible, I've
gone ahead and ordered 10 more:
  
  16187   Sun Jun 6 15:59:51 2021 YehonathanUpdateCDSOpto-isolator for c1auxeyAccording to the BO interface circuit board
https://dcc.ligo.org/D1001266,
PCIN wires are connected to the coil driver
 Optical_isolator_Wiring.pdf 
  16188   Sun Jun 6 16:33:47 2021 JonUpdateCDSBI channels on c1auxey



There
  
  16189   Mon Jun 7 13:14:20 2021 YehonathanUpdateCDSBI channels on c1auxeyI added a new XT1111 Acromag module to
the c1auxey chassis. I sanitized and configured
it according to the slow
  
  16191   Mon Jun 7 17:49:19 2021 Ian MacMillanUpdateCDSSUS simPlant modelAdded difference to the graph. I included
the code so that others could see what it
looks like and use it for easy use.
 SingleSusPlantTF.pdfTF_Graph_Code.zip 
  16193   Tue Jun 8 11:54:39 2021 YehonathanUpdateCDSBI channels on c1auxeyI tested the digital inputs the following
way: I connected a DB9 breakout to DB9M-5
and DB9M-6 where digital inputs are hosted.
  
ELOG V3.1.3-