  5907   Wed Nov 16 10:11:20 2011 steveUpdatePSLIOO angle & pos qpd centered


   
        
            
 iooqpds.png 
  5909   Wed Nov 16 10:25:57 2011 steveUpdateSUSPRM damping restoredThe  PRM lost damping about a day
ago. It was restored.
  
  5912   Wed Nov 16 14:34:18 2011 steveUpdatePSLIOO beam moves in pitchC1:IOO-QPD_ANG_VERT beam movement 
in 1 degree C temp change in 3 hrs
 
 iooqpds.png 
  5927   Thu Nov 17 15:19:06 2011 steveUpdateSUSTi spring plunger to hold OSEM is not affortableOur existing 300 series SS plungers from
McMastercar #8476A43 are silver plated as
Atm2 shows.
 20111116111042405.pdfP1080216.JPG 
  5950   Fri Nov 18 16:37:14 2011 steveUpdateVACpreparing for ac power interruptionThe vacuum is ready for no AC power for
1 hr on Sunday morning at 10am
 
 planednopower.png 
  5962   Sun Nov 20 13:51:54 2011 steveUpdateVACvacuum is back up after ac interruptionState condition: Vac Normal,         
CC1 ~8e-6 Torr
The IFO pressure peaked at 
 notpumping.png 
  6025   Mon Nov 28 15:43:36 2011 steveUpdateRF SystemEOM temp zoomed


   
        
            
 eomtempmon.png 
  6036   Tue Nov 29 15:25:29 2011 steveUpdateRF SystemEOM temp stabilization performance It is not obvious what is working.
 
 2days.png 
  6058   Thu Dec 1 11:25:10 2011 steveUpdatePEM40m infrastructure holds up well in strong wind condition Santa Anna wind speed was locked
around 60 kmph last night on campus. The
strongest in 30 years.  The lab hold
 santaannawind.pngwind.png 
  6120   Wed Dec 14 14:40:53 2011 steveUpdateGreen Lockingdelay line bnc cable specsThe existingly used used Pasternack Enterprices
RG58 C/U cable lenght ~ 140 ft and the specs
are here at Atm1
 rg58cu.jpgRG58-P.pdf 
  6139   Tue Dec 20 15:49:21 2011 steveUpdatePEMoptical table top3/4 " thick colored acrylic material
will be used in this air tight design. Surgical
tubing for o-ring. We may have to put an
 05150901.PDF 
  6168   Wed Jan 4 09:06:50 2012 steveUpdateComputerspossible front-end timing issue


   
        
            
 rtntstat.png 
  6172   Thu Jan 5 09:08:48 2012 steveUpdateGeneralframebuilder is backDataviewer is recovered after heavy new
year party.
 dataviewerisback.png 
  6180   Mon Jan 9 08:47:35 2012 steveUpdateSUSETMX damping restoredETMX sus damping restored   
  6184   Tue Jan 10 09:17:23 2012 steveUpdatePhotosstrawman's visiters   P1080491.JPGP1080492.JPG 
  6188   Thu Jan 12 07:44:21 2012 steveUpdateSUSsapphire wire standoff quote
On Tue, Dec 20, 2011 at 11:37 PM,
Rana Adhikari wrote:
 standoff.PDF 
  6190   Thu Jan 12 10:11:59 2012 steveUpdatePEMoptical table top with 1" wall

    

       
            
 101122012atc.PDF 
  6210   Wed Jan 18 12:38:44 2012 steveUpdatePEMAcrylic plexiglass transmittance   Acrylite-Gp.pptxroscogel_red#26_film.pdf 
  6223   Wed Jan 25 17:32:03 2012 steveUpdateGreen Lockinggeen pointing into y arm is misalignedI  placed an other Y2-LW-1-2050-UV-45P/AR
steering mirror into the beam path of the
green beam launching in order to avoid the
  
  6226   Thu Jan 26 08:36:38 2012 steveUpdateSAFETYevacuation drillIt started with fire alarm test yesterday
at 14:50 All alarms are  functioning
VERY loud and their flashers are bright.
  
  6227   Thu Jan 26 10:17:01 2012 steveUpdateGreen Lockinggeen pointing into y arm is realigned

    

       
            
 P1080513.JPG 
  6232   Fri Jan 27 09:05:41 2012 steveUpdateSUSOSEM locking plunger

    

       
            
  
  6236   Mon Jan 30 08:17:06 2012 steveUpdateIOOPMC


   
        
            
 sickPMC.png 
  6237   Mon Jan 30 16:18:51 2012 steveUpdatePEMRoscolux colored film transmittance at 1064 nm 
 Roscolux filter films 
#74 night blue,  0.003" thick 
  
  6239   Tue Jan 31 08:44:10 2012 steveUpdateIOOlaser shuts down 
 The 2W Innilight shutdown shut
when I opened side door for safety scan.
 laseroff.png 
  6241   Tue Jan 31 17:13:49 2012 steveUpdateIOOonly the PSL laser is off 
The 2W PSL laser is turned off. 
  
  6242   Wed Feb 1 17:00:57 2012 steveUpdateIOOlaser is back ON

    

       
            
 P1080525.JPGP1080514.JPGP1080518.JPG 
  6245   Fri Feb 3 14:47:51 2012 steveUpdatePEMlaser interlock drawing Rough draft of     
updated
interlock drawing by Ben is here.
  
  6247   Fri Feb 3 16:13:49 2012 steveUpdatePEMLED lights for chamber illuminationCold
LED lights replaced hot halogen ones.
Flat LED MYAL 6S,  model #112560002 
 P1080526.JPG 
  6250   Fri Feb 3 17:31:09 2012 steveUpdateGeneralgreen welding glassSchott, green welding glass, shade 14,
3 mm thick  was measured in the beam
path of 1.2W, S polarization of 1064nm at
 02031202.JPG 
  6256   Mon Feb 6 11:07:21 2012 steveUpdateSUSOplev QPD Sum Trends are suspicious


   
        
            
 oplevsums.png 
  6257   Mon Feb 6 17:06:11 2012 steveUpdateSUSoplev transferfunction of PIT: ETMY & ETMXKiwamu showed me how to do transferfunction
of oplev pitch
 ETMX_PIT.pngETMY_PIT.png 
  6259   Tue Feb 7 16:30:46 2012 steveUpdateSUS ALL oplev PIT transfer functionsSUS- BS, ITMX, ITMY, PRM, SRM, ETMX &
ETMY_OLPIT transfer funtion with sine wave
excitation 0.1 amplitude:
 7x 
  6260   Wed Feb 8 16:37:02 2012 steveUpdateSUSITMX OSEM LL is sickI'm driving C1:SUS-ITMX_OLYAW and PIT_EXC
with amplitude 0,1-0.3 while taking transfer
funtions of oplev.
 ITMXsensorLL.pngITMXsensorLLyaw.1.pngETMX.2amplPIT2.png 
  6263   Thu Feb 9 16:46:02 2012 steveUpdateSUS ALL oplev YAW transfer functions


   
        
            
 7x 
  6264   Thu Feb 9 17:11:05 2012 steveUpdateSUSmore OSEM problemsThese observations of the OSEMs  were
taken while taking transfer functions of
oplev YAW at excitation amplitude 0.1
 ETMXosemEXC0.1ampl.pngIMTX-YAW0.1.pngBSosemEXC.1ampl.pngPRMosemEXC.1ampl.png 
  6268   Fri Feb 10 11:01:31 2012 steveUpdateIOOcrazy ground motion


   
        
            
 seism1davg.png 
  6269   Fri Feb 10 11:46:44 2012 steveUpdateIOOseismic noise back to normalThe shaking has stopped at 9:32am 
The AC was turned back on at 11:30am 
We still do not have any explanation
 seism4h.pngseis60s.pngoneday.png 
  6270   Fri Feb 10 15:46:59 2012 steveUpdateSUSruby wire standoffFinally I found a company who can do Koji's
improved  -hard to make-  specification
on ruby or sapphire wire standoff.
  
  6273   Fri Feb 10 15:54:27 2012 steveUpdatePEMAC turned back ONThe air cond was off for 2 hrs.  I
just switched it back on at 15:51
  
  6278   Tue Feb 14 08:22:27 2012 steveUpdateSUSsus damping restoredITMX, PRM and BS watchdogs are tripped.
They were restored.
Stable MC was disabled so I can use
  
  6280   Tue Feb 14 17:09:05 2012 steveUpdateGeneralreflectivity of green welding glass Schott, Athermal green welding glass,
shade #14 reflectivity was measured in 1.2W, 
~1 mm diameter  beam of MC reflected.
 gg#14ref.pdfgg14refl1Wps.png 
  6282   Wed Feb 15 11:34:01 2012 steveUpdate under the shouth end optical tableI added an U channel based bottom shelf
at the south end today.
 P1080535.JPGP1080537.JPG 
  6288   Thu Feb 16 09:59:16 2012 steveUpdateASCIP- ANG Initial pointing or IP-ANG is a pointing
monitor of the MC. This beam is launched
after the second  pzt  steering
 lastIPang.png 
  6299   Tue Feb 21 08:33:16 2012 steveUpdateGreen Lockingperiscope adapter plateTwo extender plates ready for cleaning.
The existing optical table tops have 38"
OD. Using two of these the OD will be 44"
 percplate.PDF 
  6308   Thu Feb 23 09:09:33 2012 steveUpdateSAFETYsafety checksEmergency exit lights were inspected: 
2 out of 13 batteries have to be replaced
One of the Halon fire extinguishers
  
  6309   Thu Feb 23 10:53:54 2012 steveUpdateSUS oplev PIT transfer functions Oplev transfer functions PIT UGF
were optimized to be at 2-3 Hz with 60 degree
minimum phase margin by adjuting oplev gains.
 oplPITtrans.pdf 
  6312   Fri Feb 24 08:06:52 2012 steveUpdateSUSsus restored


   
        
            
 freePRM.pngnoisyPRM.png 
  6322   Mon Feb 27 10:21:37 2012 steveUpdateSAFETYsafety audit tomorrow morning


   
        
            
  
  6323   Mon Feb 27 14:35:22 2012 steveUpdateSUS oplev YAW transfer functions The BS and the PRM have 3.3 Hz resonant
gain filters that kill the phase margins.
 
 oplYAWtransf.pdf 