   +  Reply  Mon Aug 6 09:34:02 2018, Steve, Update, VAC, RGA scan at day 20 pd81d20.png
   +  Reply  Thu Aug 16 07:50:28 2018, Steve, Update, VAC, pumpdown 81 at day 30 pd81d30.png
   +  Reply  Thu Aug 16 14:48:14 2018, Steve, Update, VAC, why do we need a root pump? 6x
   +  Reply  Fri Aug 24 10:51:23 2018, Steve, Update, VAC, pumpdown 81 at day 38 d38.png
   +  Reply  Wed Aug 29 09:56:00 2018, Steve, Update, VAC, Maglev controller needs service 
Entry  Fri Sep 21 16:51:43 2018, gautam, Update, VAC, c1vac1 is unresponsive 
   +  Reply  Mon Sep 24 15:06:10 2018, gautam, Update, VAC, c1vac1 reboot + TP1 controller replacement beforeReboot.pngafterReboot.pngCC1.png
   +  Reply  Wed Sep 26 10:07:16 2018, Steve, Update, VAC, why reboot c1vac1 NOcomm.pngReboot_&_sawp.pngc1vac1&2_.jpg
   +  Reply  Thu Oct 4 08:25:50 2018, Steve, Update, VAC, rga scan pd81 at day 78 pd81d78.png
   +  Reply  Fri Oct 12 08:27:05 2018, Steve, Update, VAC, drypump forepump.png
   +  Reply  Fri Oct 12 17:37:03 2018, Steve, Update, VAC, pressure gauge choices  
   +  Reply  Mon Oct 15 13:59:42 2018, Steve, Update, VAC, drypump replaced drypump_swap.png
   +  Reply  Mon Oct 22 15:19:05 2018, Steve, Update, VAC, Maglev controller serviced our_controller_is_back.png
Entry  Wed Oct 31 17:54:25 2018, gautam, Update, VAC, CC1 hornet power connection restored cc1_Hornet.png
Entry  Tue Nov 6 23:19:06 2018, gautam, Update, VAC, c1vac1 FAIL lights on (briefly) Screenshot_from_2018-11-06_23-18-23.pngScreenshot_from_2018-11-06_23-19-26.png
   +  Reply  Wed Nov 7 08:32:32 2018, Steve, Update, VAC, c1vac1 FAIL lights on (briefly)...checked Vac_MC_OK.png
   +  Reply  Tue Nov 13 16:15:01 2018, Steve, Update, VAC, rga scan pd81 at day 119 pd81-d119.pngpd81-560Hz-d119.png
   +  Reply  Fri Nov 16 10:26:12 2018, Steve, Update, VAC, single viton O-rings Single-O-ring.png
   +  Reply  Fri Nov 16 15:09:31 2018, Steve, Configuration, VAC, not venting cryo and ion pumps 
   +  Reply  Mon Nov 19 14:59:48 2018, Chub, Update, VAC, Vent 81 
   +  Reply  Mon Nov 19 17:09:00 2018, Steve, Update, VAC, Vent 81 beforeVent82.pngvent81completed.png
   +  Reply  Mon Nov 19 22:01:50 2018, gautam, Update, VAC, Loose nut on valve IMG_7171.JPG
   +  Reply  Tue Nov 20 13:13:01 2018, gautam, Update, VAC, IMC alignment is okay 
   +  Reply  Mon Nov 26 15:58:48 2018, Steve, Update, VAC, Vent 81 
   +  Reply  Tue Nov 27 17:06:51 2018, Steve, Configuration, VAC, Agilent 84FS turbo installed as TP2 
Entry  Wed Dec 19 14:19:15 2018, Koji, Summary, VAC, Plan for pumpoing down test Screenshot_from_2018-12-19_14-49-34.png
Entry  Wed Dec 19 21:14:50 2018, gautam, Update, VAC, Pumpdown tomorrow  
   +  Reply  Thu Dec 20 08:38:27 2018, Jon, Update, VAC, Pumpdown tomorrow  
   +  Reply  Thu Dec 20 10:28:43 2018, gautam, Update, VAC, Heavy doors back on for pumpdown 82 
   +  Reply  Fri Dec 21 11:13:13 2018, gautam, Omnistructure, VAC, N2 line valved off VacGauges.pngScreenshot_from_2018-12-21_13-02-06.png
   +  Reply  Fri Dec 21 12:57:10 2018, Koji, Omnistructure, VAC, N2 line valved off 
   +  Reply  Thu Jan 3 15:08:37 2019, gautam, Omnistructure, VAC, Vac status unknown Screenshot_from_2019-01-03_15-19-51.pngScreenshot_from_2019-01-03_15-14-14.png997B13A9-CAAF-409C-A6C2-00414D30A141.jpeg
   +  Reply  Fri Jan 4 10:25:19 2019, Jon, Omnistructure, VAC, N2 line valved off 
   +  Reply  Wed Jan 9 11:07:09 2019, gautam, Update, VAC, New Vac channel logging Screenshot_from_2019-01-09_11-08-28.png
Entry  Wed Jan 9 20:01:25 2019, Jon, Update, VAC, Second pumpdown completed Screenshot_from_2019-01-09_20-00-39.pngIMG_3088.jpg
   +  Reply  Thu Jan 10 10:23:46 2019, gautam, Update, VAC, overnight leak rate OvernightLeak.png
Entry  Thu Jan 10 11:32:40 2019, Chub, Update, VAC, Manual valve interfaced with CDS 
Entry  Thu Jan 10 19:59:08 2019, Jon, Update, VAC, Vac System Running Normally on Turbo Pumps Screen_Shot_2019-01-10_at_7.58.24_PM.pngCCs.pngTPs.png
Entry  Mon Jan 14 10:06:53 2019, gautam, Update, VAC, Vent 82 complete Vent82Summary.png
Entry  Fri Jan 18 17:44:14 2019, gautam, Update, VAC, Pumping on RGA volume CC4.png
Entry  Sun Jan 20 23:41:00 2019, Jon, Omnistructure, VAC, Notes on vac serial comm, adapter wiring Jon_wiring_notes.tar.gz
   +  Reply  Tue Jan 22 20:45:21 2019, gautam, Update, VAC, New N2 setup 
   +  Reply  Fri Jan 25 16:14:51 2019, gautam, Update, VAC, Vacuum interlock code, N2 warning 
   +  Reply  Sat Feb 2 21:53:24 2019, Koji, Update, VAC, overnight leak rate Screen_Shot_2019-02-02_at_21.49.33.png
   +  Reply  Sun Feb 3 15:15:21 2019, gautam, Update, VAC, overnight leak rate Jan10_data.pngFeb1_data.png
   +  Reply  Sun Feb 3 20:52:34 2019, Koji, Update, VAC, overnight leak rate 
   +  Reply  Mon Feb 4 12:23:24 2019, gautam, Update, VAC, pumpdown 83 - leak tests PD83.png
   +  Reply  Tue Feb 5 10:11:30 2019, gautam, Update, VAC, leak tests complete, pumpdown 83 resumed Annuli.pngMainVol.png
   +  Reply  Tue Feb 5 19:30:14 2019, gautam, Update, VAC, Main volume at 20 uTorr PD83.png
   +  Reply  Thu Feb 7 13:55:25 2019, gautam, Update, VAC, RGA turned on 