40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 331 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  6848   Thu Jun 21 15:00:55 2012 steveUpdateSAFETYSURFs 2012 safety trainingMasha, Eric, Yaakov, Liz and Sasha received
40m specific basic safety training.
 surfs2012.JPG 
  6860   Sat Jun 23 18:44:15 2012 steveUpdateGeneralpower surge has no effect on the labI was notified by CIT Utilities that there
was a power surge or short power outage this
after noon.
  
  6864   Mon Jun 25 08:21:40 2012 steveUpdateGeneralAC power disturbance on Sat

    

       
            
 powerdisturbed.png 
  6894   Fri Jun 29 11:02:00 2012 steveUpdateVACthe vent is at 500 torr

    

       
            
 sussum.pngpzt.png 
  6895   Fri Jun 29 13:11:31 2012 steveUpdateVAC40m IFO at atm The 4 hrs vent plot at 3 torr/min
rate.
Nitrogen was used from 1e-6 torr
 vent06292012.png40m@ATM.png 
  6898   Sat Jun 30 18:31:38 2012 steveUpdateIOOinput telescope beam clipping on Faraday  We could set up a simple pick 
off after the Faraday  and bring it 
out the north window of IOO chamber. No monitor
  
  6906   Tue Jul 3 17:23:50 2012 steveUpdateVACpumpdown completedVacuum Normal State is reached in 9 hours. 
CC1 =  2e-5 Torr
Aux dry pump #3 is still running. 
 pd72.pngpd72vacnormal.pngpd72at9hrs.png 
  6927   Fri Jul 6 08:38:04 2012 steveUpdateComputerstime outWhy do we have these timing blanks?  timingblanks.png 
  6929   Fri Jul 6 09:27:40 2012 steveUpdateVAC4 days at atm I'm looking for some movement indicators
of the vent-pump down events.
 
 vent_moves.png 
  6930   Fri Jul 6 09:52:35 2012 steveUpdateVACpump down hick up I can not understand what really
happened here with CC1 gauge or there was
really a pressure glitch.
 d3wFireworks.pngpdhickup.png 
  6959   Wed Jul 11 11:18:21 2012 steveUpdatePEMmore seismic noise next week 
   The fabricators
of the big flume in the CES lab have begun
 testing the sediment feed system which is
  
  6970   Thu Jul 12 16:27:04 2012 steveUpdateVACdrypump changedTP2  dry_pump was changed at intake
pressure 982 mTorr at 84,889 hrs  This
seal hold up for one year.
  
  7044   Fri Jul 27 14:28:36 2012 steveUpdateVACcold cathode gaugesOur cold
cathode 423 gauges are 10 years old.
They get insulated by age and show no ionization
 cc_gauges.png 
  7047   Mon Jul 30 09:00:18 2012 steveUpdatePSLPMC is still not fixedThe PMC was locking right the way, but
it's transmission would not go up. 
Finally I get it back up by moving the "sticky"
 pmcA.pngpmcB.png 
  7051   Mon Jul 30 15:49:16 2012 steveUpdateVACcc1 switched

    

       
            
 cc1changedfVtH.png 
  7056   Tue Jul 31 08:01:22 2012 steveUpdateVACcc1 switched

    

       
            
 cc1h1d.png 
  7071   Wed Aug 1 16:38:46 2012 steveUpdateSUSspare SRMU 03 optic movedSOS optics prepared to be hanged are moved
from the South Flow Bench to S15 Clean Cabinet.
SRMU 03 (1-25-2010) specification
 IMG_1464.JPGIMG_1465.JPGIMG_1466.JPG 
  7087   Mon Aug 6 07:59:33 2012 steveUpdateSUSPRM oplevs servo is still bad

    

       
            
 PRMeq.png 
  7088   Mon Aug 6 09:46:31 2012 steveUpdateIOOpoweroutage turns laser off
. Power
  
  7089   Mon Aug 6 10:53:32 2012 steveUpdateVACstatus: vauum normal 
 The power outage did not have
any effect on the vacuum system.  I
 CCgauges.png 
  7091   Mon Aug 6 16:48:43 2012 steveUpdateSUSSRM oplev is clippingThe SRM oplev beam is clipping.   
  7106   Tue Aug 7 16:11:23 2012 steveUpdateSUSoptical table box wall proposal Sanwiched wall as shown: 1"
clear acrylic, 2 layers of 0.004" thick
"window tint", 1 layer of 
 IMG_1479.JPGIMG_1478.JPG 
  7154   Sun Aug 12 01:21:26 2012 steveUpdateSAFETYexit door left unlockedCaltech security called me at 1am Sunday.
 Control room emergency
  
  7160   Mon Aug 13 15:31:09 2012 steveUpdateGenerallarger optical tables at the endsI'm proposing larger
optical tables at the ends to avoid the
existing overcrowding. This would allow the
 ETMYtable.jpgETMY4X3.jpg 
  7194   Wed Aug 15 16:01:47 2012 steveUpdateGenerallarger optical tables at the ends ?The drawing of the 4' x 2'  table
cover can be seen at entry  #6190
The new proposed wall #7106 
 bottleneck.jpg 
  7248   Wed Aug 22 11:41:20 2012 steveUpdateGeneralgrout plate for optical table at the endsReinforced concrete grout plate for existing
carbon steel stands at the ends.
 
 IMG_1561.JPG08231201.PDF 
  7458   Mon Oct 1 17:03:01 2012 steveUpdateSUSETMY oplev relayed

    

       
            
 IMG_1673oplevETMY.jpg 
  7538   Fri Oct 12 16:59:26 2012 steveUpdateSUSTT PITCH damping

    

       
            
  
  7544   Mon Oct 15 08:08:33 2012 steveUpdateSUSPRM damping restored

    

       
            
  
  7652   Thu Nov 1 08:48:42 2012 steveUpdateAlignmentprogress, then setback - trend of BS table shift

    

       
            
 alignmentstrugle2d.pngalignmentstrugle2da.pngbefpd09252012.png 
  7831   Fri Dec 14 09:05:04 2012 steveUpdatePEMTT after eq 6.1 
 SRM, ITMY and MC3 moved some
what, but how are the TT? It may worth looking
 eq6.1.png 
  8240   Wed Mar 6 11:33:09 2013 steveUpdateSAFETYsafety audit 2013 
         
           
 IMG_0010.JPG 
  8287   Wed Mar 13 16:04:24 2013 steveUpdateSAFETYlaser safety glasses checked All safety glasses were cleaned in
soapy water by Bob. I measured their transmission
at 1064 nm, 150 mW,  beam diameter 1.5
 safetyglasseschecked.jpg 
  8309   Tue Mar 19 10:30:00 2013 steveUpdateSAFETYcrane inspection 2013 
Professional crane inspector: Fred
Goodbar found two small leaks at the Vertex
 sippingOIL.jpg03191301.PDF 
  8661   Fri May 31 10:25:17 2013 steveUpdatesafetyfirst aid kits refilled

    

       
            
 refilledFAidK.jpg 
  8687   Thu Jun 6 16:33:19 2013 steveUpdatesafetyupdated laser inventory Updated laser inventory and operator
list. They are posted in the 40m wiki and
entry doors of the 40m IFO room.
 ELSOconnected.jpg 
  9090   Fri Aug 30 08:08:29 2013 steveUpdatesafetyfire horns-flashers tested OK 
 We had fire alarm tests
 and evacuation drills at 1:30pm yesterday.
  
  9653   Wed Feb 19 08:07:01 2014 steveUpdatesafetyannual laser safety glasses check  
 All 40m laser safety glasses
are cleaned and measured this morning. 
 AA2014checked.jpg2014check.jpg 
  9672   Tue Feb 25 16:54:57 2014 steveUpdatesafetysafety audit 2014 
 We had our annual safety inspection
today.  
  
  9681   Thu Feb 27 13:11:13 2014 steveUpdatesafetysafety audit correction

    

       
            
 noDaisyChaining.jpgZbThumbnail.info 
  9699   Thu Mar 6 11:43:17 2014 steveUpdateGeneralGuralp control unitCMG-40T handheld controller unit is missing
its power supply. In order to zero the instrument
one has to apply plus and minus DC voltage.
 GuralpCU.jpgBAH.jpg 
  9704   Fri Mar 7 16:56:17 2014 steveUpdateIOOIOO qpds centered

    

       
            
 IOOqpdCentered.png 
  9705   Mon Mar 10 09:28:48 2014 steveUpdateIOOIOO pointing 2 days Morning seconds without adjustment.
 
 IOOpointing2d.pngmorningseconds.png 
  9725   Thu Mar 13 16:05:48 2014 steveUpdatesafetysafety audit 2014

    

       
            
 T1400198-v1-CIT-LIGO_Labs_Annual_Safety_Audit_2014.pdf 
  9730   Mon Mar 17 10:50:58 2014 steveUpdatesafety2014 annual crane certification

    

       
            
 2014craneCert.jpg 
  9743   Fri Mar 21 14:59:44 2014 steveUpdatePEMcontroling dustPlease take a look at the table top with
the flashlight before
 IMG_0044.JPG 
  9748   Mon Mar 24 22:13:37 2014 steveUpdateGeneralPower Failure

    

       
            
 poweroutage.png 
  9749   Tue Mar 25 14:52:57 2014 steveUpdateVACvacuum is recovered Out
gassing plus leak rate   0.15 
 17hrsNoPumping.png 
  9757   Fri Mar 28 16:26:20 2014 steveUpdateVACRGA scan after power failure

    

       
            
 afterPowerFailure.png 
  9802   Fri Apr 11 14:57:53 2014 steveUpdateLSCcongratulation 
 
 whenSheisHappy3h.pngmc4hArms3hrs.png 
ELOG V3.1.3-