Tue Nov 29 17:10:39 2011, Den, Update, digital noise, SOS creation
|
One of the possibilities that we see a large low-frequency digital noise is due to Foton. I've checked the SOS coefficients that saves Foton with a Matlab
coefficients. I used a 3 order low-pass cheby1 filter cheby1("LowPass",3,0.1,3)
In matlab I generated SOS model using 3 approaches |
Tue Nov 29 18:31:40 2011, Den, Update, digital noise, Foton error
|
In the previous elog we've compared Matlab and Foton SOS representations using low-order filter. Now we move on to high order filters and see that
Foton is pretty bad here.
We consider Chebyshev filter of the first type with cuf off frequency 12 Hz and ripple 1 dB. In the table below we summarize the GAINS obtained |
Tue Nov 29 22:19:26 2011, Den, Update, digital noise, straight line  
|
I tried to understand what part of the signal is corrupted while passing through a digital straight line without any filters. From here we can
figure out what precision is used.
I analysed coherence between C1:SUS-MC3_LSC_EXCMON and C1:SUS-MC3_LSC_OUTMON without any filters between them. |
Tue Nov 29 22:54:49 2011, Den, Update, digital noise, single precision   
|
In the previous elog we've proved that signals C1:SUS-MC3_LSC_EXCMON and C1:SUS-MC3_LSC_OUTMON are in single precision. Now we try to understand
if the precision is lost when the signals enter dtt tools or in the online code. For this measurement we just switch on one of the filters between the
signals. By this we add mathematical operations inside the online code. If double precision is used there, then we'll see the same error as before, because |
Thu Dec 1 18:30:39 2011, Vladimir, Den, Update, digital noise, Foton error
|
Foton Matlab Error
We investigated some more the discrepancy between Matlab and Foton numbers. The
comparison of cheby1(k, 1, 2*12/16384) was done between versions implemented in Matlab, R and Octave. Filters created by R and Octave agree with Foton.
Also, we found that Matlab has gross precision errors for cutoff frequencies just smaller than used in our fitler, for example cheby1(6, 2*3/16384) |
Fri Dec 2 17:43:46 2011, rana, Update, digital noise, Foton error
|
It would be useful to see some plots so we could figure out exactly what magnitude and phase error correspond to "gross" and "miserable".
|
Fri Dec 2 20:16:41 2011, Den, Update, digital noise, first order transition 
|
In order to verify our theory about coherence corruption in linear systems due to the line
if((new_hist < 1e-20) && (new_hist > -1e-20)) new_hist = new_hist<0 ? -1e-20:
1e-20; |
Wed Dec 7 20:55:44 2011, Vladimir, Den, Update, digital noise, Matlab error
|
Quote:
It would be useful to see some plots so we could figure out exactly what magnitude and phase error correspond to "gross" and "miserable". |
Tue Jul 24 21:16:55 2012, Den, Update, digital noise, quantization test 
|
I'm trying to get some intuition how digital noise due to quantization shows up in iir filters. I decided to do tests in C using Python to calculate
psd and visualize. I've implemented Direct Form 1, 2, "Biquad" and "Low Noise" forms of realization of second-order iir filter from
Matt's presentation. There is a typo in the "Low Noise Form" scheme - a1 and a2 gains should be switched. Other then that |
Wed Jul 25 16:55:01 2012, Den, Update, digital noise, notch, lowpass filters 6x
|
Direct Form 2 is noisy in the first test. This is the one similar to Matt's in his presentation. Input signal was a sine wave at 1 Hz with small
amplitude white noise x[n] = sin(2*pi*1*t[n]) + 1e-10 * random( [-1, 1] ). It was filtered with a notch filter: f=1Hz, Q=100, depth=210dB.
SOS representation was calculated in Foton. Sampling frequency is 16kHz. |
Wed Jul 25 23:03:22 2012, rana, Update, digital noise, notch, lowpass filters
|
If the problem is the precision in DTT, then why would the noise change when the corner frequency of the filter is changed?
And how about checking for filter noise in the situation we saw online? 4th order low pass at 1 Hz or 8 Hz. |
Thu Jul 26 10:22:03 2012, Den, Update, digital noise, notch, lowpass filters   
|
Quote:
If the problem is the precision in DTT, then why would the noise change when the corner frequency of the filter is changed? |
Thu Jul 26 17:39:49 2012, Den, Update, digital noise, biquad key is working   
|
I've filtered a 1 Hz sin wave excitation with a notch filter inside c1sus and c1rfm models. The biquad key is switched on in the last one, c1sus
uses DF2. The results are indeed different.
|
Thu Jul 26 21:31:44 2012, Den, Update, digital noise, online biquad works 
|
Quote:
Still I do not like huge (2n+1) harmonics in the output of the biquad filter, I do not get them in the simulations. They are |
Fri Jul 27 14:30:49 2012, Jamie, Update, digital noise, biquad key is working
|
What is "DQF"? Is that the biquad? And what is the difference between DF1 and DF2? Why don't you just write out the name,
so it's more clear. |
Mon Jul 30 14:24:25 2012, Den, Update, digital noise, biquad key is working
|
Quote:
What is "DQF"? Is that the biquad? And what is the difference between DF1 and DF2? Why don't you just write out |
Mon Jul 30 16:05:36 2012, Den, Update, digital noise, filter checker  
|
We decided to write a script that will check online filters for digital noise. One method can be implemented using the following algorithm:
calculate filter output using single precision
calculate filter output using double precision and assume that it is precise
find digital noise at the output of the filter when single precision is used
extrapolate the result to the double precision filter |
Sat Aug 4 17:32:31 2012, Den, Update, digital noise, filter checker 
|
The script estimates digital noise produces by online filters. First version of Matlab files and complied c files are in scripts/digital_noise directory.
Algorithm for 1 filter bank (max number of filters = 10):
extract sos - representation from Foton file for each filter (Matlab)
|
Tue Nov 6 18:39:16 2012, Den, Update, digital noise, ifo checking system
|
Matlab version of ifo digital noise estimation code is almost ready. It estimates digital noise introduced by each filter bank in each model. I'm waiting
for NDS group to complete function to download online data to Matlab. Now code downloads data from the past that is not great because not all _IN1 channels
are recorded and some of them are recorded at lower frequencies. |
Wed Oct 21 17:12:30 2009, Alberto, Update, elog, Browser context menu enabled on the Elog under HTM editing mode
|
On behalf of Steve and of the rest of the not-native-English community at the 40m willing to have their browser's spell checker working while editing
the Elog, I fixed the Elog's feature that prevented Firefox' context menu (that one which pops up with a mouse right click) to work when using the HTML
editing interface (FCKeditor). |
Fri Nov 6 19:29:24 2009, Jenne, Update, elog, elog acting up
|
elog was acting up again (not running), so I restarted it. |
Fri Nov 6 20:10:15 2009, Jenne, Update, elog, elog acting up
|
Quote:
elog was acting up again (not running), so I restarted it. |
Thu Nov 19 16:04:48 2009, Alberto, Configuration, elog, Elog debugging output - Down time programmed today to make changes
|
We want the elog process to run in verbose mode so that we can see what's going. The idea is to track the events that trigger the elog crashes.
Following an entry on the Elog Help Forum, I added this line to the elog starting script start-elog-nodus:
./elogd -p 8080 -c /cvs/cds/caltech/elog/elog-2.7.5/elogd.cfg -D -v > elogd.log 2>&1 |
Thu Nov 19 18:49:55 2009, Alberto, Configuration, elog, Elog debugging output - Down time programmed today to make changes
|
Quote:
We want the elog process to run in verbose mode so that we can see what's going. The idea is to track the events that |
Tue Feb 2 18:15:47 2010, Alberto, Update, elog, Elog restarted it
|
Zach made me notice that the elog had crashed earlier on this afternoon.
I just restarted it with the restarting script.
Instructions on how to run the last one are now in the wiki page. Look on the "How To" section, under "How to restart the elog". |
Wed Feb 3 10:46:12 2010, Alberto, Update, elog, elog restarted
|
Again, this morning Zach told me that the elog had crashed while he was trying to post an entry.
I just restarted it. |
Thu Feb 4 00:59:52 2010, rana, Update, elog, elog restarted
|
I restarted the ELOG on NODUS just now. Our attempt to set up error logging worked - it turns out ELOG was choking on the .ps file attachment.
So for the near future: NO MORE .PS
files! Use PDF - move into the 20th century at least. |
Fri Mar 12 13:52:18 2010, Zach, Update, elog, elog restarted
|
The elog was down and I ran the restart script. |
Tue Mar 23 15:38:26 2010, Alberto, Update, elog, elog just restarted
|
I found the elog down and I restarted it.
Then, after few seconds it was down again. Maybe someone else was messing with it. I restarted an other 5 times and eventually it came back up. |
Wed Mar 31 10:34:02 2010, josephb, Update, elog, Elog not responding this morning
|
When I went to use the elog this morning, it wasn't responding. I killed the process on nodus, and then restarted, per the 40m wiki instructions. |
Fri Apr 2 08:52:21 2010, Alberto, Update, elog, elog restarted
|
i just restarted the elog for the third time in the past 12 hours.
I checked the elog.log file to debug the problem. It doesn't contain eveidence of any particular cause, except for png/jpg file uploads happened
last night. |
Tue Apr 20 13:00:52 2010, Zach, Update, elog, elog restarted
|
I restarted the elog with the restart script as it was down. |
Wed Apr 28 08:55:19 2010, Zach, Update, elog, elog restarted
|
Restarted the elog with the script as it was down. |
Wed Apr 28 09:21:16 2010, Zach, Update, elog, elog restarted
|
And again.
Quote:
|
Tue May 25 07:58:23 2010, kiwamu, Update, elog, elog down
|
I found the elog got down around 7:30 am in this morning.
So I restarted it by running the script: "start-elog-nodus" as instructed on the wiki.
http://lhocds.ligo-wa.caltech.edu:8000/40m/How_To/Restart_the_elog |
Sat Jun 12 18:03:00 2010, sharmila, Update, elog, Temperature Controller
|
Kiwamu and I setup a serial port terminal for receiving data from TC200 via a RS-232 USB interface. It was done using a Python code. Some command definitions
need to be done to get the output from TC-200. |
Thu Jul 8 17:29:20 2010, Katharine, Sharmila, Update, elog, 6x
|
Last night, we successfully connected and powered our circuit, which |
Mon Jul 12 21:26:02 2010, Katharine, Sharmila, Update, elog, maglev coils
|
The connection between our coil wires and BNC terminals was pretty awful (soldered wires broke off ) so we removed the old heat shrink and re-soldered the wires. We then chose more appropriately sized heat shrinks (small one around each of the
two soldered wires, a medium-sized shrink around the wires together, a large one covering the BNC terminal and the wire) and used the solder iron and heat |
Wed Jul 14 01:05:27 2010, Sharmila,Katharine, Summary, elog, Maglev   
|
Yesterday we hooked up the Quadrant Maglev control to the power supply to test the components in the Input/Output part of the circuit.
The output from the buffer was an unexpected high noise signal which was caused by some circuit components.
|
Fri Jul 16 12:36:00 2010, Katharine, Sharmila, Update, elog, levitation
|
After last night's challenge (or inspiration), we levitated our magnet this morning. Since the nice Olympus camera is not currently in the 40m,
we had to use my less stellar camera, but despite the poor video quality you can still see the magnet returning to its stable equilibrium position.
Once we recover the better camera, we will post new videos. Also, we haven't yet figured out how to put videos in line in the elog entry, so here |
Tue Jul 20 11:55:15 2010, Sharmila,Katharine, Update, elog, Maglev 
|
We plotted the transfer functions for the maglev control circuit and compared them with the plots from the spectrum
analyzer. We were stuck for sometime because
|
Sat Aug 7 10:47:38 2010, Koji, Summary, elog, elog restarted / source of the trouble eliminated
|
Nancy notified me that the elog crashed. It was fixed.
I restarted elog, but it kept crashing. Some of the entries on Aug 6th caused the trouble.
I tried to refresh the pictures in entries 3376, 3377, 3378. Still it kept crashing. |
Tue Aug 10 01:05:17 2010, Zach, Update, elog, elog restarted
|
Elog was down. Restarted with the script. |
Wed Aug 11 02:44:37 2010, Zach, Update, elog, elog restarted
|
You'll never guess what happened: the elog crashed!
I restarted it with the script. Yay. |
Wed Aug 11 16:13:59 2010, Jenna, Update, elog, elog restarted
|
The elog crashed, so we restarted it again. |
Thu Aug 12 11:39:27 2010, Zach, Update, elog, elog restarted
|
with script |
Thu Aug 12 23:17:54 2010, Zach, Update, elog, restarted
|
script |
Thu Aug 12 23:41:48 2010, Jenne, Update, elog, restarted
|
Quote:
script |
Fri Aug 13 13:11:30 2010, Dmass, Update, elog, restarted
|
Quote:
|
Mon Aug 16 23:13:25 2010, Zach, Update, elog, e to the log
|
Zach
I get so many freebies it's ridiculous
|