Entry  Thu Apr 21 14:39:43 2011, steve, Update, RF System, new strain relieved N connectors at AP P1070562.JPGP1070564.JPG
New right angle PVC, 2 x 2 x  1/4" installed at the AP table to strain relief the 1/4" spiral corrugated RF coaxes.
Entry  Thu Apr 21 15:03:29 2011, steve, Update, Computers, juction board finds home P1070570.JPGP1070568.JPG
The anti aliasing box was opened up at the back to accommodate the junction board and the SCSI cable towards the ADC. Aluminum plate was attached to
the bottom to hold the strain relief clamp.
Three more hanging junction cards will be replaced in this manner.
    Reply  Thu Apr 21 15:20:46 2011, steve, Update, PEM, PSL enclosure work today P1070558.JPGP1070560.JPG


    
        
            Quote:
        
        
            

           The east side window guides  will be replaced by one long U-channel. There will be drilling into 2x2 steel frame. It should be done
Entry  Mon May 2 13:43:05 2011, steve, Frogs, Photos, birthday boys P1070622.JPG
.....Happy.... Birthday.... to.... Joseph... and... Jamie...Happy....Birthday..... to.... You............sing with us........Happy Birthday.....to you
Entry  Mon May 2 17:10:55 2011, steve, Update, SUS, PRM oplev 
The returning spot diameter on the qpd ~10 mm. In order to reduce the spot size I moved the f 1145 mm lens toward the PRM ~ 25 cm. The spot size was
reduced to ~8 mm, 3200 counts.
I'll try to find an other lens tomorrow.
Entry  Tue May 3 15:59:22 2011, steve, Frogs, Photos, X-mas comes early P1070634.JPG
The little red all terrain cargo wagon 40" x 18"  has just arrived on pneumatic wheels.
Model #29, 200 lbs max load at 26 PSI,  minimum age requirement 1.5 years
    Reply  Tue May 3 16:20:13 2011, steve, Update, SUS, PRM & BS oplevs are ready P1070630.JPGP1070632.JPG


    
        
            Quote:
        
        
            

           The returning spot diameter on the qpd ~10 mm. In order to reduce the spot size I moved the f 1145 mm lens toward the PRM ~ 25 cm. The spot
Entry  Thu May 5 10:19:22 2011, steve, Update, PSL, PSL-FSS_RMTEMP is back P1070637.JPG
Valera and I installed the the temp sensor and the interface box that Rana fixed. This may help with diagnosing the PSL drift.
    Reply  Thu May 5 15:05:06 2011, steve, Update, PSL, PSL-FSS_RMTEMP is not back rtnfxd.jpg


    
        
            Quote:
        
        
            
            Valera and I installed the the temp sensor and the interface box that Rana fixed. This may help with diagnosing the
Entry  Thu May 5 15:33:37 2011, steve, Configuration, RF System, LSC rack P1070641.JPGP1070639.JPG
New right angle PVC front panel with SMA bulkhead connectors are in place. The connections are still lose. It is ready for Suresh to finalise his vision
on it.
Entry  Fri May 6 10:20:00 2011, steve, Summary, SAFETY, 2011 safety audit sa2011done1.pdfP1070448.JPG
The emphasis of this annual safety audit  was on  safe  electrical housekeeping on March 3, 2011

Safety audit correction list for the electric shop:

1, install breaker panel door in room 101
2, install conduit- AC out let in the east arm for USB camera table  and
   
Entry  Fri May 6 15:59:40 2011, steve, Update, VAC, TP3 fore pump replaced 
Dry fore pump of TP3 replaced by brand new Varian SH-110  at  1.1 Torr_75,208 hrs
The annuloses were closed off for 25 minutes. We are back to VACUUM NORMAL mode.
The TP3 fore line pressure dropped to 44 mTorr at 25 minutes in operation.......9.4mTorr at day 2 with full annulos load
Entry  Fri May 6 17:11:55 2011, steve, Update, SUS, SRM-oplev cable  
The SRM qpd cable was removed from the BS-table. It's path was changed from 1x4 to ITMY-table following the inner cable tray.
Entry  Tue May 10 11:14:44 2011, steve, Update, PSL, PSL-QPD_ANG qpd optimized qpdangl.jpg
Valera and I placed F 572.7 mm lens ~15 cm away  from the ang  qpd (in the same mount with ND filter) so that two qpds see different combination
of ang and pos motion - there was no lenses prior to this change. The beam diameter is reduced to ~half .
    Reply  Wed May 11 11:05:45 2011, steve, Update, SUS, ETMX_OPLEV : He-Ne replaced P1070672.JPG


    
        
            Quote:
        
        
            

           I found that a He-Ne laser which has been used for ETMX_OPLEV was NOT giving the light.
    Reply  Wed May 11 11:24:59 2011, steve, Update, SUS, SRM-oplev qpd is back srm-prm_oplevs.jpg


    
        
            Quote:
        
        
            

           The SRM qpd cable was removed from the BS-table. It's path was changed from 1x4 to ITMY-table following the inner cable tray.
Entry  Wed May 11 13:54:32 2011, steve, Update, LSC, LSC power supplies P1070679.JPG
Aux- rack _1Y2 is just behind 1Y3  It contains Kepco Analoge DC power supplies for +- 5, 15 and 24V
Placing these power supplies away from the LSC rack was an effort to minimize pick up from them.
 
    Reply  Thu May 12 08:54:11 2011, steve, Update, IOO, IP_POS cable found 


    
        
            Quote:
        
        
            

           A cable for IP_POS has been disconnected at the LSC rack, 1Y2. Due to it currently no IP_POS signal
Entry  Thu May 12 09:00:23 2011, steve, Update, General, optical table covers must be used 
I found ITMX-ISCT and BS-ISCT ( IFO sensing-control table)  not covered this morning. Please do not leave tables open.
Entry  Mon May 16 17:11:28 2011, steve, Update, Electronics, strain relieved 1X1 P1070724.JPG
1X1 is strain relieved in the back. I will use similar approach on the rest of the racks .
    Reply  Thu May 19 17:53:03 2011, steve, Update, CDS, AA filter box modified at 1X5 P1070727.JPG


    
        
            Quote:
        
        
            

           [Steve, Joe]
Entry  Fri May 27 17:52:53 2011, steve, Update, LSC, LSC rack cables strain relieved & labeled 
LSC rack 1Y2 cables are strain relieved and labeled. Spare and/or obsolete cables are laid out on the top of the beam tube and on the outside of the
rack.
The POY 110 MHZ demodboard has a very touchy position in the VME crate. Watch out for it! It has to be fixed.
Entry  Tue May 31 11:34:13 2011, steve, Summary, SAFETY, safety glasses checked P1070823.JPG
  1064 nm transmison were measured of 40m safety glasses as shown . Their performance did not degrade. They are as good as their labels.
Entry  Tue May 31 17:30:42 2011, steve, Update, SUS, ETMY damping restored 
ETMY's watch dogs were found tripped. They were restored.
Entry  Fri Jun 3 18:12:03 2011, steve, Update, Computers, no PEM channels 
AA filter box was removed and modified at 1Y7 today. The -5V power supply was current limited when I plugged it back in. It was removed for medical attention.
NO PEM channels available! because of this.
 
    Reply  Mon Jun 6 17:28:31 2011, steve, Update, Computers, still, no PEM channels P1070846.JPG


    
        
            Quote:
        
        
            

           AA filter box was removed and modified at 1Y7 today. The -5V power supply was current limited when I plugged it back in. It was removed for
Entry  Tue Jun 7 16:11:09 2011, steve, Update, Cameras, ITM camera lenses changed P1070865.JPGP1070860.JPG
Computar  75-12.5 zooms were installed for closer look at the resonant spots.  Their alignment and focus needs more loving adjustment. 
Atm 1, ITMX  (  it was 10-40 mm Tamron before )
Atm 2, ITMY  ( it was 12mm wide angle showing the towers  before )
Entry  Thu Jun 9 10:38:30 2011, steve, Update, PSL, PMC needs help pmcnothp.jpg
The PMC is losing power.
    Reply  Tue Jun 14 09:24:36 2011, steve, Configuration, Photos, SUS binary IO chassis 2 and 3 moved from 1X5 to 1X4 P1070891.JPGP1070893.JPG


    
        
            Quote:
        
        
            

           While preping 1X4 for installation of c1lsc, we removed some old VME crates that were no longer in use.  This freed up lots of space
    Reply  Thu Jun 16 08:45:14 2011, steve, Update, SUS, Vertex SUS Binary Output Boxes removed P1070894.JPG


    
        
            Quote:
        
        
            

           - I was investigating the SUS whitening issue.
Entry  Fri Jun 17 08:03:48 2011, steve, Update, SUS, ITMY sus damping restored 
ITMY sus damping restored.
 
Entry  Mon Jun 20 09:04:13 2011, steve, Update, SUS, ETMX damping restored 
ETMX sus damping restored
    Reply  Mon Jun 20 16:44:02 2011, steve, Update, ABSL, I-P curve of LightWave M126-1064-700 
 
 Put the serial numbers into the elog. So we can identify the laser and controller in the future.
The old days the NPRO ( inside the MOPA ) was running ~1.7A  500 mW
Entry  Tue Jun 21 16:11:13 2011, steve, Update, SAFETY, surf safety training P1070902.JPG
40m surfs:  Nicole Ing, Iswita Saikia and Sonali Mohapatra received 40m specific safety training  today.
Entry  Thu Jun 23 10:17:49 2011, steve, Update, PSL, AP table is open to PSL again P1070911.JPGP1070910.JPG
Access to the north side of the PSL table is blocked by the    8" beam guard. This opens the beam pathways between them.
Entry  Thu Jun 23 10:35:12 2011, steve, Update, Computers, old computers leaving the lab P1070905.JPGP1070904.JPGblade1000.JPG
Rod Luna picked up these computers for Larry Wallace yesterday: Dell Inspiron 530, Dell Dimension 4600 and SunBlade 1000
Entry  Fri Jun 24 07:40:23 2011, steve, Update, SUS, PRM damping restored 
The PRM sus damping restored. C1:SUS-PRM_SDPD_VAR is still 20-30mV and going up.  Side gain  turned on. This pulled it down to 5-8 mV
Why is the side osem sensing voltage 4.4V ? It can not be higher than ~2.4V.......something is rotten in the state of Denmark?
Edit by KI:
    Reply  Fri Jun 24 07:49:23 2011, steve, Update, ABSL, I-P curve of LWE with serial numbers 


    
        
            Quote:
        
        
            

            The I-P curve was
Entry  Fri Jun 24 10:38:01 2011, steve, Update, Cameras, ITMY camera gets fixed 
ITMY gets new Tamron M118FM50 that has improved close focusing. It is a small fixed focal length camera so the video tube cover can be put on.
The Watec LCL-902K 1/2" ccd camera was losing it power supply voltage because of bad connection. It was replaced.
Entry  Mon Jun 27 16:57:06 2011, steve, Update, Photos, Haixing is back P1070914.JPG
He has moved the levitation stuff for his surf student to Jan's lab in W-Bridge.
    Reply  Tue Jun 28 10:11:13 2011, steve, Update, IOO, Power incident on REFL11 and REFL55 


    
        
            Quote:
        
        
            

           I measured the power incident on REFL11 and REFL55.  Steve was concerned that it is too high.  If we consider this elog
Entry  Tue Jun 28 15:23:21 2011, steve, Update, Electronics, Coilcraft RF-design kits are restocked P1070917.JPGP1070915.JPG
Our design kits are full again. They are waiting for a new brilliant PD design.
Entry  Wed Jun 29 11:45:54 2011, steve, Update, General, where are we storing PDs ? P1070921.JPG
Photo diodes stored in the east arm cabinet E4:  ALL PDs  meet here, fast  or slow......
Entry  Thu Jun 30 17:24:46 2011, steve, Update, SAFETY, safety interlocks  P1070949.JPGP1070948.JPG
Lightwave M126-1064-700 lasers  sn415  at east end of the Y arm and  sn201 at the AP table  are connected individually  to one
each EMERGENCY LASER SHUT OFF SWITCH. 
Entry  Tue Jul 5 08:32:38 2011, steve, Update, PEM, bad air quality in the lab badaq.jpgjuly4pem.jpg
The fireworks of yesterday showing up in the lab. Pasadena out side air 6.6 million  cfm for 0.3 micron particles  and 1.5 million cfm for
0.5 micron size.
Entry  Tue Jul 5 13:35:56 2011, steve, Update, SUS, PRM damping restored 
The PRM sus damping was restored. It's side rms motion came down from 35 to 4 mV immediately.      Lab   air quality is
back to normal.
 
Entry  Thu Jul 7 10:25:34 2011, steve, HowTo, General, cleaning out refregerator 
Please ask the owner unless  it is rotten. Do not put food into garbage can inside. Take them outside so you are not inviting ants !
Entry  Thu Jul 7 13:57:28 2011, steve, HowTo, SAFETY, how not to 
I found baked allen keys on the top of the clean optics cabinet.  Somewhat heavy box that can come down in an earthquake on our heads.
NOTHING SHOULD GO ON THE TOP OF THE CABINETS OR RACKS except  small
plastic boxes that storing our clean clothing.
Entry  Mon Jul 11 14:03:37 2011, steve, HowTo, lore, how to visit your old lab P1080069.JPG
Alberto is visiting us from Australia. He brought some terrific presents. It is going to be very demanding task to wait for the rest of the 40m team
to return from Wales to taste coffee:  PNG Peaberry of Wagonga, Monsooned Malabar of Jindebah and Signature Blue Blend of Cosmorex.
Entry  Fri Jul 15 16:14:00 2011, steve, Update, SUS, BS oplev error signal spectra BS_opl_ersig.pdf
 