  974   Fri Sep 19 11:48:14 2008 steveUpdateComputers old hubs can make one happyJoseph finds a XIX century bottle neck hub:
CentreCOM 3624TR 10Base-T 
and happily replaces it with Netgear GS724T
 P1020934.jpg 
  984   Tue Sep 23 11:17:59 2008 steveUpdatePSLPMC scattering spotThe PMC output side has a new madly scattering
spot at chamfer 2 o'clock position
 rainbow.pngpmcclip.png 
  996   Fri Sep 26 09:05:47 2008 steveUpdateSUSMC2 damping restoredThe MC2 sus damping was restored.   
  1004   Mon Sep 29 11:17:14 2008 steveUpdateSAFETYhorizontal viewports are protected with lexanThe four horizontal viewports of arms are
protected 
by 3/8" thick, 8.5" OD Lexan disk of MR10
  
  1007   Mon Sep 29 15:09:36 2008 steveUpdatePSLalmost 4 yrs plot of power & tempsThe water chiller is normally running 1.5
C warmer than the laser head temp.
When control room temp is stable and PEM-count_temp
 3.5y.jpg 
  1020   Thu Oct 2 16:44:28 2008 steveSummaryoplevsoptical leversThe idea is to push the  UGF to 10 Hz of the
TM oplev servos with quiet HeNe laser.
We measured good intensity noise of JDS 1103P
  
  1027   Mon Oct 6 10:00:49 2008 steveUpdateMOPAMOPA_HTEMP is upMonday morning conditions:

The laser head temp is up to 20.5 C
 htup.jpg 
  1057   Mon Oct 20 09:45:56 2008 steveUpdatePEMPSL HEPA onThe PSL HEPA filter was turned on.
It should be running all times.
The 0.5 micron particle count is up to 20,000
  
  1062   Tue Oct 21 16:14:42 2008 steveUpdateGeneraldivergence of He Ne 1035PThe ITM oplevs laser diodes are noisy.
They will be replaced by JDS 1035P
SN T8093307 was measured with the beamscanner.
 1035p_divergence.png 
  1068   Wed Oct 22 16:22:53 2008 steveBureaucracySAFETYCaryn received safety trainingCaryn Polatchi has received 40m safety training
on Monday, Oct 20
  
  1071   Thu Oct 23 11:26:25 2008 steveBureaucracyVACoptosigma forks for vacuumNine short forks from OptoSigma were cleaned,
baked and measured by Bob T.
They passed the LIGO vac compatiblity test
  
  1082   Fri Oct 24 11:09:08 2008 steveUpdateSAFETYmore lexan plates under camerasThe MC2, MC3&1 and BSC-SUS cameras were repositioned
somewhat in the 
process of placing lexan disks under neat
  
  1085   Fri Oct 24 15:05:13 2008 steveUpdateVACrga is out of orderThe old Dycor  RGA is out of order.
I'm getting ready to purchase an SRS instrument.
  
  1094   Mon Oct 27 11:23:10 2008 steveUpdatePhotosnew Olympus camera with IR visionThe IR blocker was removed from our new Olympus
camera 
SP 570UZ camera.
 IRisin.JPG 
  1103   Fri Oct 31 08:52:19 2008 steveUpdateSUSETMY damping restoredETMY watchdogs were tripped yesterday morning
also. This is a problem that existed some
months ago.(?)
 etmy2d.jpg 
  1107   Mon Nov 3 09:59:47 2008 steveUpdatePSLPSL HEPAs turned onThe psl [COLOR=chocolate]enclosure[/COLOR]
HEPAs were tuned on.
  
  1116   Thu Nov 6 09:45:27 2008 steveUpdateMOPAhead temp hick-up vs power The control room AC temp was lowered from
74F to 70F around Oct 10
This hold the head temp rock solid 18.45C
 htpr.jpg 
  1117   Thu Nov 6 10:06:41 2008 steveUpdateLockingarms lock degradationI have been locking the arms in the mornings
lately.
The daily drift of LSC-TRX is ~ 15% and LSC-TRY
 arms.jpg 
  1120   Fri Nov 7 08:08:00 2008 steveUpdatePEMAC turned off in IFO roomAll [COLOR=red]tree[/COLOR] AC units in IFO
room 104 switched off at 7:45am
I'm looking for the periodic thump signal
  
  1121   Fri Nov 7 10:52:57 2008 steveUpdatePEMAC is back onThe 20 minutes and 6 sec thumps are not related
to the 40m ac units
This period is precisely right on so it is
 acf.jpgacc_mc1.jpgtest.jpg 
  1123   Fri Nov 7 16:05:55 2008 steveBureaucracySAFETYinsect killer sprayed at kitchen area !
Bob and I cleaned out the sink area and sprayed
Spectracide's BUG STOP insect killer solution
  
  1127   Mon Nov 10 16:44:14 2008 steveUpdatePEMparticle counter at MC2The particle counter was moved to MC2 table
temporarily.
It is clamped to the table at the south west
  
  1129   Mon Nov 10 19:39:40 2008 steveUpdatePEMthump noise from particle counterThe particle counter is back on the IOOC location
on a piece of  FOAM 
It needs this isolation, so when the pump
 partcfm.jpg 
  1134   Fri Nov 14 11:33:19 2008 steveUpdateVACSRS-RGA installedOld Dycor rga is removed and new SRS-RGA200
installed.
It is pumped down and ready for hooking up
  
  1149   Thu Nov 20 09:37:39 2008 steveUpdatePSLMZ vs tempThis 12 days plot shows that it can hold lock
if the daily temp variation is not more than
3/4 of a degree C
 mztemp.jpg 
  1197   Fri Dec 19 16:38:09 2008 steveUpdateLSCall optlevs centeredAll optlevs were centered after full alignment.

Qpd sums are:
  
  1199   Sun Dec 21 13:00:06 2008 steveUpdateall down cond.vac and laser back onThere was a power outage sometimes early Saturday.

All things are down.
  
  1219   Fri Jan 9 09:14:17 2009 steveUpdatePEMifo is recovered after eqThere is no obvious damage from last night
earth quake.
All sus dampings were turned on, MC locked
 eq4.5sb.jpg 
  1220   Fri Jan 9 16:52:18 2009 steveUpdateVACtp3 forline pump replacedAlberto took 40m vacuum 101 class as we replaced
the drypump at the annulus pump line.
  
  1226   Wed Jan 14 09:22:43 2009 steveHowToVACN2 supply pressure lowered for vac valves[quote]I've been replacing the N2 bottles
recently.
I noticed that the consumption is too high.
 n280d.jpg 
  1227   Wed Jan 14 10:59:06 2009 steveBureaucracyVACrga waiting to be "connected"We have no RGA data since old Dycor passed
away in the middle of Oct, 2008
New SRS-RGA200 was installed on the vac envelope
  
  1228   Wed Jan 14 15:53:32 2009 steveDAQPSLMC temperature sensor[quote]I added a channel for the temperature
sensor on the MC1/MC3 chamber: C1:PSL-MC_TEMP_SEN.
To do that I had to reboot the frame builder.
  
  1229   Thu Jan 15 09:19:32 2009 steveUpdateIOOMC locking MC2 sus damping was found tripped at the morning
the second time this week.
  
  1243   Thu Jan 22 08:34:10 2009 steveBureaucracySAFETYsafety trainingKakeru received 40m safety training yesterday.

He has no authorization to work alone in
  
  1248   Fri Jan 23 10:00:21 2009 steveUpdatePSLPMC transmission is downThe PMC transmission is going down.
I have not relocked the PMC yet.
 pmc4d.jpg 
  1273   Thu Feb 5 09:12:29 2009 steveBureaucracySAFETYsafety updates & fire alarm testThe fire alarm test was completed at 13:30
yesterday.
 
  
  1280   Fri Feb 6 14:49:31 2009 steveSummarySAFETYlaser inventory
40M Laser Inventory at Feb 05,
2009
 

1, Lightwave PA#102 @ 77,910
  
  1282   Fri Feb 6 16:23:54 2009 steveUpdateMOPAMOPAs of 7 years MOPAs and their settings, powers of 7 years
in the 40m
 7ymopas.jpg 
  1288   Tue Feb 10 10:48:48 2009 steveBureaucracySAFETYsafety glasses scannedAll 40m safety glasses are absorbent.
 
They
were scanned by 180 mW  2mm spot size 
of 1064 nm beam and  their  transmissions
 sgscan1.pngsgscan2.png 
  1293   Wed Feb 11 11:39:17 2009 steveConfigurationGeneralvac envelope groundThe vacuum envelope was grounded from
the IOO chamber to master ground north (under
electric breaker panel L)
with
  
  1300   Fri Feb 13 08:38:03 2009 steveUpdateIOOMC2 damping restored    
  1302   Fri Feb 13 16:30:49 2009 steveConfigurationGeneralstatus quo is disturbed I have been getting ready for the annual
safety inspection in the past 2-3 days.
Meaning cleaning up and disturbing
  
  1319   Wed Feb 18 15:31:38 2009 steveBureaucracySAFETYemergency back-up lights checkedAll
13 exit and  emergency back-up lights
and their batteries were checked.
  
  1324   Thu Feb 19 11:51:56 2009 steveUpdateMOPAHTEMP variation is too muchThe C1:PSL-MOPA_HTEMP variation is more
than 0.5 C daily
Normally this
temp stays well within 0.1 C
This
 80dhtemp.jpg 
  1332   Mon Feb 23 11:07:01 2009 steveBureaucracySAFETYKiwamu receives safety trainingOsamu and Kiwamu received 40m safety training
on Thursday, Feb 19, 2009
Kiwamu needs Osamu's close supervision
  
  1347   Tue Mar 3 08:44:31 2009 steveUpdatePEMair cond. maintenance todayIFO room 104 air conditions will be shut
down for maintenance today.
This
should be finished by noon.
The
  
  1387   Wed Mar 11 16:41:22 2009 steveUpdateMOPAspare NPRO power The spare M126N-1064-700,  sn 5519
of Dec 2006 rebuilt  NPRO's power output
 measured   750mW
  
  1411   Fri Mar 20 11:01:02 2009 steveUpdatePEMparticle counts are highThe outside particle counts for 0.5 micron
are 3 million this morning at 9am. Low clouds,
foggy condition with low inversion layer.
 particles32d.jpg 
  1414   Fri Mar 20 15:54:29 2009 steveOmnistructureGeneral480V crane power switch on MEZCES Mezzanine is beeing rebuilt to accommodate
our new neighbor: the 20ft high water slide...&
.jacuzzi
  
  1420   Tue Mar 24 09:04:02 2009 steveUpdateSUS4.8 mag earthquakeSRM, ITMX, ETMX, ITMY and ETMY lost damping
at 4:55am this morning from 4.8 magnitude
earthquake.
  