  382   Fri Mar 14 16:56:03 2008 DmassBureaucracyComputersNew 40m control machine.I priced out a new control machine from Dell
and had Steve buy it.
  
  381   Fri Mar 14 15:52:07 2008 robConfigurationLSCLSC code change
I've edited the LSC code to send different
signals to the ASS box.  Now, instead of
  
  380   Fri Mar 14 15:06:24 2008 robUpdateComputer Scripts / Programsrouting PEM -> ASS -> SUS_MCL[quote]
on ASS RFM 1 has PEM signals at
  
  379   Fri Mar 14 14:59:51 2008 josephbConfigurationCamerasComparison between GC650 (CCD) and GC750 (CMOS) looking at ETMXAttached are images taken of ETMX while locked.

The first two are 300,000 microsecond exposure
 ETMX_z2_exp_300000_650.tiffETMX_z2_exp_300000_750.tiffETMX_z2_exp_30000_650.tiffETMX_z2_exp_30000_750.tiff 
  378   Fri Mar 14 12:06:29 2008 josephbConfigurationCamerasGC750 looking at ETMX while lockedThe GC750 (CMOS) is currently looking at the
front of ETMX.  Unfortunately, its being
routed through a 10Mbit connection (which
 ETMX_zoom_exp_10000_750.tiff 
  377   Thu Mar 13 18:20:29 2008 JohnUpdateGeneralNew Focus 4003 EOM 29.489MHzI measured the modulation index as a function
of drive power using an OSA. Agrees well
with spec of 0.2 rad/V.
 4003.jpg 
  376   Thu Mar 13 13:15:09 2008 aivanovUpdateComputer Scripts / Programsnew sfotware intall, backup filesNew:
op440m:40m>ls -alt /cvs/cds/caltech/target/c1susvme[12]/*.o
-rw-r--r--    1 controls staff       57920
  
  375   Thu Mar 13 12:11:58 2008 aivanovUpdateComputer Scripts / Programsrouting PEM -> ASS -> SUS_MCL
on ASS RFM 1 has PEM signals at
  
  374   Thu Mar 13 03:07:19 2008 LisaMetaphysicsEnvironmentCoolness at the 40mMy first (and hopefully not last) week at
the [COLOR=orange]40m lab[/COLOR] is ending
:(
  
  373   Thu Mar 13 02:52:06 2008 LisaConfigurationLSCLocking with 3fToday we have tried to use the reflected signal
demodulated at 3*f1 ~ 99 MHz ([COLOR=chocolate][B]REFL31[/B][/COLOR])
for length control.
  
  372   Wed Mar 12 23:05:44 2008 ranaUpdateIOOMC WFSthey are bad, somewhat

please fix
  
  371   Wed Mar 12 00:47:26 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsAnd this is a [COLOR=blue]cool snapshot[/COLOR]
showing how this operation used [B][COLOR=red]16
cores[/COLOR][/B] on [SIZE=5][B][COLOR=purple]menkar
 Screenshot.png 
  370   Wed Mar 12 00:40:35 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsSame as above but with 2048 taps and a 128
Hz sample rate. Does much better at the 16
Hz bounce mode.
 mc2048-128.pdf 
  369   Wed Mar 12 00:36:52 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsI used the MISO FIR Wiener matlab code to
see how well we might do in principle.
 finished.pdf 
  368   Tue Mar 11 23:14:01 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsSteve and Matt moved the accelerometers and
seismometers today. 
The accelerometers are now placed around
 Acc.pdf 
  367   Mon Mar 10 20:46:41 2008 JohnConfigurationLSCETMY Trans PD & QPDI've placed a 10% reflector in the path from
ETMY to the trans and quadrant photodiodes.
  
  366   Mon Mar 10 02:05:08 2008 robUpdateLockingDRMI+2ARMs working better
Some encouraging progress on the locking
front tonight.  After the work on the DRM
  
  365   Fri Mar 7 19:04:39 2008 steveOmnistructurePSLlaser pointerGreen laser pointer was found in my desk.
I blamed Rana for not returning it to me
after a conference talk.
  
  364   Fri Mar 7 17:10:01 2008 Max JonesUpdateComputersNoise Budget workNoise budget has been moved to the svn system.
A checked out copy is in the directory caltech.
From now on, I will try to use the work cycle
  
  363   Fri Mar 7 00:47:54 2008 ranaConfigurationPEMRanger SS-1Yesterday evening around 7:30 PM, I changed
the Ranger seismometer from a 
vertical to a horizontal seismometer. To
 ss1.pdf 
  362   Thu Mar 6 00:17:37 2008 robUpdateLockingDD handoff workingGot the DD (double demod) handoff scripts
working tonight, with just the DRMI.  So,
now acquisition with the single demod signals
  
  361   Wed Mar 5 17:35:24 2008 ranaUpdateIOORFAM during MC lockI used an ezcaservo command to adjust the
offsets for Alberto's StochMon channels.
They [B][COLOR=green]are all
 rfam.pdf 
  360   Wed Mar 5 12:51:48 2008 JohnSummaryLSCInitial Ligo Arm finesse versus lambdaI've taken the coating recipes for the initial
ligo arm cavity from Rana's web page (ligo.caltech/edu/~rana/mat/)
and plotted the finesse as a function of
 FofLambdaLIGOI.jpg 
  359   Wed Mar 5 12:35:09 2008 JohnSummaryComputer Scripts / ProgramsPlot photodiode responses in MatLabA matlab function to plot the responses of
photodiodes. There's still plenty of room
for improvement but it should work for all
 PD6DeltaT.jpgPD6.jpgPDbw.jpg 
  358   Tue Mar 4 23:22:32 2008 robDAQComputersc1susvme1&2 rebooted
I found that some channels from c1susvme1
and c1susvme2 were not being recording by
  
  357   Tue Mar 4 20:14:02 2008 ranaConfigurationIOOMC AlignmentThe MC alignment was pretty far off. We were
getting TEM01 mode locks only. 
Rather than inspect what happened I just
  
  356   Tue Mar 4 19:14:09 2008 ranaConfigurationCDSTDS & SVN[COLOR=purple][I]Matt, Rob, Rana[/I][/COLOR]

[B][COLOR=chocolate]Today we added the TDS
  
  355   Tue Mar 4 10:08:21 2008 robUpdateComputersgreen lights unreliable when c0daqctrl down
So far I've tried powering off the framebuilder,
power-cycling the RAID (it was showing an
  
  354   Tue Mar 4 00:42:51 2008 ranaUpdateComputersFB0 still down ?The framebuilder is still down. I tried restarting
the daqd task and resetting the RFM
switch like it says in the Wiki but it still
  
  353   Mon Mar 3 19:34:40 2008 ranaUpdateComputers RFM Network are down[quote]The CODAQ_RFNETWORK are down, except
C1SUSVME & AWG[/quote]
All of the FE machines were found to be down
  
  352   Mon Mar 3 13:58:10 2008 steveUpdateComputers RFM Network are downThe CODAQ_RFNETWORK are down, except C1SUSVME
& AWG
  
  351   Mon Mar 3 09:25:33 2008 steveUpdateVACrga scan logging is working now[quote][quote]The rga head and controller
are running fine, but the data logging is
not.[/quote]
 rgalogworks.jpgcc1.jpg 
  349   Sun Mar 2 23:43:45 2008 ranaHowToLSCPD6 responseJohn's PD plotting script is superior to all
of the ones we had before; lets make him
post the script so we can all use it.
  
  348   Fri Feb 29 13:51:17 2008 JohnSummaryLSCPD6 responseI checked the response of PD6 using the AM
laser. It looks happy enough.[IMG]elog:348/1[/IMG]
 PD6Attempt3.jpg 
  347   Thu Feb 28 19:49:21 2008 robUpdateElectronicsRF Monitor (StocMon)
[quote]
With Ben, we hooked up the RF Monitor box
  
  346   Thu Feb 28 19:37:41 2008 robConfigurationComputersmultiple cameras running and seisBLRMS[quote]1) Mafalda is now connected via an
orange Cat5E ethernet cord to the gigabit
ethernet switch in rack in the office space.
  
  345   Thu Feb 28 16:19:37 2008 josephbConfigurationComputersMafalda rewired and multiple cameras running1) Mafalda is now connected via an orange
Cat5E ethernet cord to the gigabit ethernet
switch in rack in the office space.    It
  
  344   Thu Feb 28 13:04:59 2008 robUpdateVACrga logging working again[quote]The rga head and controller are running
fine, but the data logging is not.[/quote]
  
  343   Thu Feb 28 12:31:33 2008 robBureaucracyComputer Scripts / ProgramsMDV library does not work at "LINUX 2"[quote]
While working on Thursday evening with Matlab
scripts "dttfft2" and "get_data", I noticed
  
  342   Wed Feb 27 22:05:03 2008 JohnUpdateLSCAuxiliary lockingA summary of the status of the auxiliary arm
locking effort.
  
  341   Tue Feb 26 20:24:04 2008 AndreySummaryTMISorrowAs for that plot of three-dimensional surface,
I indeed was wrong with the axis "Q_ETMX-Q_ITMX"
(I put there wrong string "Q_ITMX-Q_ETMX").
  
  340   Sun Feb 24 10:51:58 2008 tfFrogsEnvironment40m in phdcomics?[url=http://www.phdcomics.com/comics/archive.php?comicid=977][img]http://www.phdcomics.com/comics/archive/phd021308s.gif[/img][/url]   
  339   Fri Feb 22 21:19:38 2008 AndreyBureaucracyComputer Scripts / ProgramsMDV library does not work at "LINUX 2"
While working on Thursday evening with Matlab
scripts "dttfft2" and "get_data", I noticed
  
  338   Fri Feb 22 20:42:44 2008 AndreySummaryComputer Scripts / ProgramsIt seems I succeeded in theoretical simulations
I am pretty happy at this moment.
 RMS_peak_08Hz-Theoretical.pngRMS_peak_08Hz-QI-QE.pngRMS_peak_3Hz-Theoretical.pngRMS_peak_broad-interv-Theoretical.png 
  337   Fri Feb 22 16:47:54 2008 robUpdateElectronicsBaloneyWell I guess Rana didn't study too hard at
Professor School, either.  If he'd even bothered
to actually read John's entry, he might have
 bustedHP.mov 
  336   Fri Feb 22 15:16:33 2008 AndreyUpdatePEMITMX Accelerometer is NOT broken
As I wrote in message 330, there was a bad
signal from ITMX accelerometer. I have found
 Accelerom-ITMX-Feb23.jpgAccelerom-ETMX-Feb23.jpg 
  335   Fri Feb 22 14:45:06 2008 steveUpdateMOPAlaser power levels
At the beginning of this 1000 days plot shows
the laser that was running at 22C head temp
 lpower1000d.jpg 
  334   Fri Feb 22 11:13:15 2008 robUpdateElectronicsRF Monitor (StocMon)[quote] It took some times because the written
procedure to start the chiller is not very
precise.[/quote]
  
  333   Fri Feb 22 11:11:00 2008 robUpdateElectronicsREFLDD problem found
I used a network analyzer that actually works
to find a problem in the REFLDD electronics
  
  332   Fri Feb 22 08:33:18 2008 AlbertoUpdateElectronicsRF Monitor (StocMon)[quote]I put the amplifiers next to the monitor
on the PSL table, layed the power and the
RF SMA cables out to the rack. I'm powering
  