40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
40m Log, Page 328 of 335
Not logged in
List
|
Find
|
Login
|
Help
New entries since:
Wed Dec 31 16:00:00 1969
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Type --
Configuration
Update
Summary
HowTo
Bureaucracy
Omnistructure
Metaphysics
Frogs
16720 Entries
Goto page
Previous
1
,
2
,
3
...
327
, 328,
329
...
333
,
334
,
335
Next
ID
Date
Author
Type
Category
Subject
Text
2261
Thu Nov 12 18:10:27 2009
Alberto
Update
ABSL
PLL Locked
I locked the PLL and made some first measuremtns
of the spectrum of the error signal. I'll
post them later.
2321
Tue Nov 24 14:33:22 2009
Alberto
Update
ABSL
working on the AP table
I'm working on the AP table. I also opened
the auxiliary NPRO shutter. The auxiliary
beam is on its path on the AP table and PSL
2324
Tue Nov 24 19:16:02 2009
Alberto
Update
ABSL
working on the AP table
2326
Wed Nov 25 08:43:08 2009
Alberto
Update
ABSL
Working on the AP table
I'm working on the AP table. I also opened
the auxiliary NPRO shutter. The auxiliary
beam is on its path on the AP table and PSL
2328
Wed Nov 25 10:20:47 2009
Alberto
Update
ABSL
AbsL PLL not able to lock
Last night something happened on the
beat between the PSL beam and the auxiliary
NPRO beam, that spoiled the quality of the
2329
Wed Nov 25 11:02:54 2009
Alberto
Update
ABSL
AbsL PLL not able to lock
2334
Wed Nov 25 15:42:27 2009
Alberto
Update
ABSL
Working on the AP table
2337
Wed Nov 25 20:14:58 2009
Alberto
Update
ABSL
AbsL PLL not able to lock: problem fixed
2338
Wed Nov 25 20:24:49 2009
Alberto
Update
ABSL
PLL Open Loop Gain Measured
I measured the open loop gain of the PLL
in the AbsL experiment.
I repeated the measurement twice:
2339
Wed Nov 25 20:28:17 2009
Alberto
Update
ABSL
Stopped working on the AbsL
I closed the shutter of the NPRO for the
night.
2342
Fri Nov 27 02:25:26 2009
rana
Update
ABSL
PLL Open Loop Gain Measured
2420
Tue Dec 15 21:39:34 2009
Alberto
Update
ABSL
brief summary of this afternoon's measurements
I took measurements of the open loop
gain of the AbsL PLL with the old Universal
PDH Box.
I Also measured the
2421
Wed Dec 16 11:21:20 2009
Alberto
Update
ABSL
Universal PDH Box Servo Filters
Yesterday I measured the shape of the
servo filter of both the old and the new
Universal PDH boxes.
Here they
2422
Wed Dec 16 11:46:25 2009
Alberto
Update
ABSL
Absl PLL Open Loop Gain
Yesterday I measured the Open Loop Gain
of the PLL in the absolute length experiment.
The servo I used was that of the old Universal
2423
Wed Dec 16 11:55:47 2009
rana
Update
ABSL
Universal PDH Box Servo Filters
To me, they both look stable.
I guess that the phase has to go to -180
2460
Mon Dec 28 15:34:14 2009
Alberto
Update
ABSL
Working on the AP table
I opened the auxiliary laser's shutter.
I'm currently working on the AP table.
2461
Mon Dec 28 18:35:27 2009
Alberto
Update
ABSL
Working on the AP table
2493
Sat Jan 9 15:02:01 2010
Alberto
Update
ABSL
PRC scanning
I scanned the PRC in the frequency range
of 30-60 MHz, untill the PLL lost lock. But
everything is working fine.
The
2502
Mon Jan 11 11:06:53 2010
Alberto
Update
ABSL
Measurement running
2504
Mon Jan 11 16:59:14 2010
Alberto
Update
ABSL
Interferometer Busy
I'm currently running a measurement on
the PRC.
Please don't interfere with the IFO
2505
Mon Jan 11 19:36:13 2010
Alberto
Update
ABSL
Measurement running
Leaving for dinner. Back in ~1hr.
I left a measurement running. Please
don't interfere with it till I'm back. Thanks.
2506
Mon Jan 11 21:49:17 2010
Jenne
Update
ABSL
Measurement running
2508
Tue Jan 12 09:37:05 2010
Alberto
Update
ABSL
IFO available
I finished measuring the AbsL for this
morning. The IFO is again available.
Please don't mess up with the
2513
Wed Jan 13 12:03:00 2010
Alberto
Update
ABSL
Measurement now running. Please be careful
At the moment I'm running a measurement
on the PRC and I'm planning to leave it going
for the time we'll be at the 40m meeting.
2521
Mon Jan 18 18:34:01 2010
Alberto
Update
ABSL
Measurement in progress
I started a long measurement of the PRC's
transmissivity. I'm leaving the lab and I'm
going to be back at about 8 tonight. Please
2522
Mon Jan 18 20:58:40 2010
Alberto
Update
ABSL
Measurement in progress
2531
Tue Jan 19 12:54:39 2010
Alberto
Update
ABSL
Measurement in progress
A measurement will be running for the next
hour. Please be careful.
2532
Tue Jan 19 16:21:18 2010
Alberto
Update
ABSL
Watchdogs not working and then fixed
This afternoon the watchdogs stopped working:
they didn't trip when the suspension positions
crossed the threshold values.
2534
Wed Jan 20 20:11:56 2010
Alberto
Update
ABSL
Some preliminary results from measuring PRC's transmissivity for an amplitude modulated beam
Here I'm posting a plot showing a
set of measurements that I made in the past
few days to determine the absolute length
2536
Thu Jan 21 10:31:13 2010
Koji
Update
ABSL
Some preliminary results from measuring PRC's transmissivity for an amplitude modulated beam
Nice
and interesting plot.
2541
Fri Jan 22 02:54:06 2010
Alberto
Update
ABSL
Overnight measurement
I'm leaving a measurement running overnight.
It should be done in about one hour.
Tomorrow morning, If you need to
2543
Fri Jan 22 14:40:49 2010
Alberto
Update
ABSL
Overnight measurement
2545
Mon Jan 25 16:30:37 2010
Alberto
Update
ABSL
166 MHz sideband turned off
I turned off the modulation at 166MHZ
becasue I don't need it if I'm only locking
the PRC.
2546
Mon Jan 25 16:46:33 2010
Alberto
Update
ABSL
166 MHz sideband turned off
2547
Tue Jan 26 03:28:56 2010
rana
Update
ABSL
166 MHz sideband turned off
You can turn the 166 off if
you want. MZ is unhappy after its turned
2550
Wed Jan 27 11:02:30 2010
Alberto
Update
ABSL
PRC Cavity Length
I fitted the data from scanning
the PRC by changing the beat frequency of
the auxiliary laser beam with the PSL beam.
The
2553
Fri Jan 29 12:06:58 2010
Alberto
Update
ABSL
Measurement running today at lunch time
I just started a measuremtn that will be
running for the next hour or so. Please be
careful with the interferometer.
2554
Fri Jan 29 13:14:49 2010
Alberto
Update
ABSL
Measurement running today at lunch time
2576
Mon Feb 8 14:13:03 2010
Alberto
Update
ABSL
PLL Characterization
Lately I've been trying to improve the
PLL for the AbsL experiment so that it could
handle larger frequency steps and thus speed
2577
Mon Feb 8 14:56:17 2010
Alberto
Update
ABSL
Suddenly a much better alignment of PRC
I just aligned PRM and locked PRC and I
noticed that SPOB is much higehr than it
used to be. It's now about 1800, vs 1200
2578
Mon Feb 8 15:01:46 2010
rob
Update
ABSL
Suddenly a much better alignment of PRC
2579
Mon Feb 8 15:41:51 2010
Alberto
Update
ABSL
Suddenly a much better alignment of PRC
2581
Tue Feb 9 09:07:06 2010
Alberto
Update
ABSL
PLL Characterization
2582
Tue Feb 9 10:10:58 2010
Alberto
Update
ABSL
back to analog
I want to try to do the measurement with
the network analyzer used as local oscillator,
instead of the Marconis that I'm using now.
2679
Thu Mar 18 10:46:51 2010
Koji
Update
ABSL
PLL reconstructed
Last night (Mar 17) I checked the PLL
setup as Mott have had some difficulty to
get a clean lock of the PLL setting.
2680
Thu Mar 18 12:27:56 2010
Alberto
Update
ABSL
PLL reconstructed
2681
Thu Mar 18 13:40:35 2010
Koji
Update
ABSL
PLL reconstructed
We use the current PLL just now, but the
renewal of the components are not immediate
as it will take some time. Even so we need
2684
Thu Mar 18 21:42:26 2010
Koji
Update
ABSL
PLL reconstructed
I checked the setup further more.
I replaced the PD from
NewFocus 1GHz one to Thorlabs PDA255.
2696
Mon Mar 22 22:11:26 2010
Mott
Update
ABSL
PLL reconstructed
It looks like the PLL drifted
alot over the weekend, and we couldn't get
2697
Mon Mar 22 23:37:32 2010
Mott
Update
ABSL
PLL reconstructed
We have managed to lock the PLL to
reasonable stability. The RF input is attenuated
Goto page
Previous
1
,
2
,
3
...
327
, 328,
329
...
333
,
334
,
335
Next
ELOG V3.1.3-