474
|
Tue May 13 10:15:52 2008 |
steve | Update | SUS | restored damping of BS & PRM | I think our janitor was cleaning too heavy
handedly.
The BS and PRM sus damping were lost.
|
|
1553
|
Thu May 7 10:28:20 2009 |
steve | Update | VAC | retrofitted maglev's needs |
Our spare Osaka maglev purchased
in Oct 2005 turned out to be having a viton |
|
4562
|
Sun Apr 24 21:37:40 2011 |
kiwamu | Update | IOO | review of triple resonant EOM : model looks fine | To design a new resonant EOM box I started
reviewing the prototype that I've built.
As a part of reviewing I checked |
 |
3813
|
Thu Oct 28 20:08:26 2010 |
yuta | Update | Green Locking | revised RF amp cascading | Background:
Yesterday, I said I will use
ZHL-32A for amplifying beat note signal, |
|
13282
|
Thu Aug 31 18:36:23 2017 |
gautam | Update | CDS | revisiting Acromag | Current
status:
There
is a single Acromag ADC unit installed in |
|
13422
|
Thu Nov 9 15:33:08 2017 |
johannes | Update | CDS | revisiting Acromag |
|
|
13536
|
Thu Jan 11 21:09:33 2018 |
gautam | Update | CDS | revisiting Acromag | We'd like to setup the recording of
the PSL diagnostic connector Acromag channels
in a more robust way - the objective is to |
|
475
|
Tue May 13 10:38:28 2008 |
steve | Update | Computers | rfm network is down | The RFM network went down yesterday around
5pm
Only c1susvme1 is alive but it's timing is |
|
322
|
Tue Feb 19 10:14:13 2008 |
steve | Update | VAC | rga logging needs help | The rga head and controller are running fine,
but the data logging is not. |
|
129
|
Wed Nov 28 08:47:29 2007 |
steve | Omnistructure | VAC | rga is out of order | The rga is not working since Nov 10
The controller is broken.
pd65-m-d23 |
|
1085
|
Fri Oct 24 15:05:13 2008 |
steve | Update | VAC | rga is out of order | The old Dycor RGA is out of order.
I'm getting ready to purchase an SRS instrument. |
|
344
|
Thu Feb 28 13:04:59 2008 |
rob | Update | VAC | rga logging working again | [quote]The rga head and controller are running
fine, but the data logging is not.[/quote]
|
|
76
|
Wed Nov 7 09:38:01 2007 |
steve | Update | VAC | rga scan | pd65-m-d2 at cc1 6e-6 torr |
|
887
|
Tue Aug 26 15:06:16 2008 |
steve | Configuration | VAC | rga scan | Pumpdown 66 PRM-maglev vac normal -day 11
short form: pd66PRM-m-d11 |
|
14291
|
Tue Nov 13 16:15:01 2018 |
Steve | Update | VAC | rga scan pd81 at day 119 |
|
 |
14229
|
Thu Oct 4 08:25:50 2018 |
Steve | Update | VAC | rga scan pd81 at day 78 |
|
|
351
|
Mon Mar 3 09:25:33 2008 |
steve | Update | VAC | rga scan logging is working now | [quote][quote]The rga head and controller
are running fine, but the data logging is
not.[/quote]
|
 |
1227
|
Wed Jan 14 10:59:06 2009 |
steve | Bureaucracy | VAC | rga waiting to be "connected" | We have no RGA data since old Dycor passed
away in the middle of Oct, 2008
New SRS-RGA200 was installed on the vac envelope |
|
1452
|
Fri Apr 3 10:01:50 2009 |
steve | Update | VAC | rgascan with temp plot | Rga scan of day 231 since pumpdown pd66-m-d231
m stands for maglev pumping speed,
vacuum normal condition of valves, |
 |
7029
|
Wed Jul 25 15:33:55 2012 |
janosch | Update | LSC | ringdown measurement | We did our first ringdown measurement on
the Y arm. First we tried to keep the arm
locked in green during the ringdown, but |
|
7033
|
Wed Jul 25 22:16:36 2012 |
Koji | Update | LSC | ringdown measurement | Is this the step response of the single
pole low pass???
It should have an exponential decay, |
|
7301
|
Tue Aug 28 18:28:21 2012 |
janosch | Metaphysics | Ringdown | ripples | Let's see if the ripples observed
in the MC ringdown can be due to tilt
motion of the mirrors. |
|
7302
|
Tue Aug 28 19:06:32 2012 |
Koji | Metaphysics | Ringdown | ripples | Isn't it just a ringing of the intracavity
power as you shifted the laser frequency
abruptly? |
|
7303
|
Tue Aug 28 19:21:37 2012 |
janosch | Metaphysics | Ringdown | ripples | Hmm. I don't know what ringing really
is. Ok, let's assume it has to
do with the pump... I don't see how |
|
7304
|
Tue Aug 28 20:23:54 2012 |
Koji | Metaphysics | Ringdown | ripples | Laser frequency shift = longitudinal motion
of the mirrors
Ringing: http://www.opticsinfobase.org/ol/abstract.cfm?uri=ol-20-24-2463 |
|
7305
|
Wed Aug 29 09:35:03 2012 |
janosch | Metaphysics | Ringdown | ripples 2 | Ok, so the whole idea that mirror motion
can explain the ripples is nonsense. At least,
when you think off the ringdown with |
|
1383
|
Wed Mar 11 01:16:40 2009 |
rana | Summary | IOO | rogue trianglewave in the MC Servo offset slider | On Monday
evening, I ran this command: trianglewave
C1:IOO-MC_REFL_OFFSET 0 4 120 600;ezcawrite |
  |
14266
|
Fri Nov 2 10:24:20 2018 |
Steve | Update | PEM | roof cleaning | Physical plan is cleaning our roof and
gutters today. |
|
11966
|
Mon Feb 1 14:08:06 2016 |
Steve | Update | PEM | roof condtion is good | It rained hard yesterday. We have not had
this strong downpoor for years. We got |
|
3495
|
Tue Aug 31 13:31:00 2010 |
steve | Update | PEM | room temp lowered | I lowered room 101 thermostat setting from
74F to 72F |
|
3497
|
Tue Aug 31 15:26:46 2010 |
rana | Update | PEM | room temp lowered | And I raised it back to 73F. The thermometers
on the wall show 74-75F as the actual room
temp. The dial on the temperature controller |
|
2646
|
Sun Feb 28 23:47:52 2010 |
rana | Update | Computers | rosalba | Since Rosalba wanted to update ~500
packages, I let it do it. This, of course,
stopped the X server from running. I downloaded |
|
6573
|
Thu Apr 26 16:35:34 2012 |
Jamie | Summary | CDS | rosalba now running Ubuntu 10.04 | This morning I installed Ubuntu 10.04 on
rosalba. This is the same version that
is running on pianosa. The two machines |
|
6653
|
Mon May 21 19:16:55 2012 |
Koji | Update | General | rossa X config | I rebooted rossa and the X sever has stalled. |
|
14780
|
Fri Jul 19 17:42:58 2019 |
gautam | Update | General | rossa Xdisp bricked | For some reason, rossa's Xdisplay won't
start up anymore. This happened right after
the UPS reset. Koji and I tried ~1.5 hours |
|
14794
|
Sun Jul 21 22:16:34 2019 |
rana | Update | General | rossa Xdisp bricked | "bricked" is to mean that it
has the functionality of a brick and can
be tossed. But rossa seems to have just gotten |
|
16075
|
Thu Apr 22 14:49:08 2021 |
gautam | Update | Computer Scripts / Programs | rossa added to RTS authorized keys | This is to facilitate running of scripts
like the CDS reboot script, mx_stream restart,
etc, from rossa, without being pwd prompted |
|
14784
|
Sat Jul 20 11:24:04 2019 |
gautam | Update | General | rossa bricked | Summary:
SnapPy |
|
6662
|
Tue May 22 20:24:06 2012 |
Jamie | Update | Computers | rossa is now running Ubuntu 10.04 | Now same as pianosa and rosalba.
I'll upgrade allegra on Friday. |
|
3524
|
Sun Sep 5 21:35:41 2010 |
rana | Configuration | Computers | rossa notes | **** Deleted
apps/emacs
apps/linux64/firefoxold |
|
3531
|
Tue Sep 7 10:50:53 2010 |
josephb | Configuration | Computers | rossa notes | The controls group is user id 500 by default
on most new machines. Unfortunately, the
user ID used across the already existing |
|
3539
|
Tue Sep 7 23:17:45 2010 |
sanjit | Configuration | Computers | rossa notes |
|
|
3557
|
Sat Sep 11 03:16:51 2010 |
rana | Configuration | Computers | rossa notes | I wiped out the old CentOS install on rossa
and installed CentOS 5.5 on there. The DVDs
are on a spindle in the control room; there |
|
3559
|
Sun Sep 12 22:36:03 2010 |
rana | Configuration | Computers | rossa notes | I found Sanjit's instructions for doing
the Nvidia settings too complicated and so
I followed these instructions from Facebook: |
|
3517
|
Thu Sep 2 21:22:31 2010 |
Sanjit, Koji | Configuration | Computers | rossa nvidia driver and dual monitor configuration |
Simple steps (but don't try these
on a working computer without getting some |
|
3518
|
Thu Sep 2 23:35:33 2010 |
rana | Configuration | Computers | rossa nvidia driver and dual monitor configuration | Why are we running CentOS 4.8 instead of
5.5 ? What runs at LLO?
What runs in Downs? |
|
3521
|
Fri Sep 3 11:23:16 2010 |
josephb | Configuration | Computers | rossa nvidia driver and dual monitor configuration | At LLO the machines are running Centos 5.5.
A quick login confirms this. Specifically
the release is 2.6.18-194.3.1.el5.
|
|
15447
|
Wed Jul 1 18:16:09 2020 |
gautam | Update | Computers | rossa re-re-revival | In an effort to make a second usable workstation,
I did the following (remotely) on rossa today
(not necessarily in this order, I wasn't |
|
15449
|
Sun Jul 5 16:14:41 2020 |
rana | Update | Computers | rossa re-re-revival | maybe we should make a "dd" copy
of pianosa in case rossa has issues
and someone destroys pianosa by accidentally |
|
14925
|
Wed Oct 2 20:45:18 2019 |
rana | Update | Computers | rossa revival | Formatted and re-installing OS on rossa
for the 3rd or 4th time this year. I suggest
that whoever is installing software |
|