Tue Apr 22 10:59:24 2008 |
rob | Update | SUS | MC1 electronics busted |
Quote: | I spent some time trying to fix the utter programming fiasco which was our MCWFS diagonalization script.
However, it still didn't work. Loops unstable. Using the matrix in the screen snapshot is OK, however.
Finally, I realized from looking at the imaginary part of the output matrix that there was something
wrong with the MC1 drive. The attached JPG shows TFs from pit-drives of the MC mirrors to WFS1.
MC1 & MC3 are supposed to have 28 elliptic low pass filters in hardware for dewhitening. The MC2
hardware is different and so we have given it a software 28 Hz ELP to compensate. But it looks like
MC1 doesn't have the low pass (no phase lag). I tried switching its COIL FM10 filters to make it
switch but no luck.
We'll have to engage the filters to make the McWFS work right and to get the MC noise down. This
needs someone to go check out the hardware I think.
I have turned the gain way down and this has stabilized the MC REFL signal as you can see from the StripTool screen. |
This was just because the XYCOM was set to switch the "dewhites" based on FM9 rather than FM10. To check whether the hardware ellipDW filters were engaged, I drove MC1 & MC3 in position (using the MCL bank), and looked at the transfer functions MC2_MCL/MC1_MCL and MC2_MCL/MC3_MCL. This method uses the mode cleaner length servo to enable a relatively clear transfer function measurement of the ellipDW, modulo the loop gain of MCL and the fact that it's really hard to measure an ELP cascaded with a suspension. The hardware and the switching appear to be working fine.
It's now set up such that the hardware is ENGAGED when the coil FM10 filters are OFF, and I deleted all the FM10 filters from the coils of MC1 and MC3. Since we don't switch these filters on and off regularly, I see no need to waste precious SUS processor power on filters that just calculate "1". |
434
|
Tue Apr 22 08:34:22 2008 |
josephb | Configuration | Cameras | Current Network Diagram |
The attached network diagram has also been added to the 40m Wiki at http://lhocds.ligo-wa.caltech.edu:8000/40m/Image_Processing_with_GigE_Cameras |
433
|
Mon Apr 21 13:12:21 2008 |
rob | Update | Computer Scripts / Programs | tdsread bugs |
Quote: | There seems to be a problem with reading the C1:IOO-MASTER_OVERFLOW field
when it is read in as part of an array. The only way for me to describe it
is to just attach the terminal output in this entry...this is mainly for
Matt and Rob.
I first noticed that the output of the MC-WFS sensing matrix was different than
the outputs from a year ago, namely that the excitation channel was not being
processed and outputted to the file. This made the output matrix diagonalization
scripts fail.
I noticed that there are several different copies of tdsread.cc sitting around.
Looks like they have been hacked in the last year but I am not sure if this
excitation channel readback is an intentional change; email has been sent to the
authors to find out -- they will probably post some kind of response in the log
to resolve what's up.
My guess is that the problem with the IOO channel is not related, but I'm not sure:
op440m:WFS>set ioo_head = "${ifo}:IOO-"
op440m:WFS>set sus_head = "${ifo}:SUS-"
op440m:WFS>set oflows = `tdsread ${sus_head}MC1_MASTER_OVERFLOW ${sus_head}MC2_MASTER_OVERFLOW ${sus_head}MC3
_MASTER_OVERFLOW ${ioo_head}MASTER_OVERFLOW`
ERROR: C1:IOO-MASTER_OVERFLOW value not read
op440m:WFS>set oflows = `tdsread ${sus_head}MC1_MASTER_OVERFLOW ${sus_head}MC2_MASTER_OVERFLOW ${ioo_head}MAS
TER_OVERFLOW`
ERROR: C1:IOO-MASTER_OVERFLOW value not read
op440m:WFS>set oflows = `tdsread ${ioo_head}MASTER_OVERFLOW`
op440m:WFS>set oflows = `tdsread ${sus_head}MC1_MASTER_OVERFLOW ${ioo_head}MASTER_OVERFLOW`
ERROR: C1:IOO-MASTER_OVERFLOW value not read
op440m:WFS>set oflows = `tdsread ${sus_head}MC1_MASTER_OVERFLOW ${ioo_head}MASTER_OVERFLOW ${sus_head}MC2_MASTER_OVERFLOW`
ERROR: C1:IOO-MASTER_OVERFLOW value not read
op440m:WFS>echo $oflows
0
op440m:WFS>set oflows = `tdsread ${ioo_head}MASTER_OVERFLOW`
op440m:WFS>echo $oflows
0
op440m:WFS>set oflows = `tdsread ${sus_head}MC1_MASTER_OVERFLOW ${sus_head}MC2_MASTER_OVERFLOW ${sus_head}MC3_MASTER_OVERFLOW`
op440m:WFS>echo $oflows
0 0 0
op440m:WFS>echo `tdsread ${sus_head}MC1_MASTER_OVERFLOW ${ioo_head}MASTER_OVERFLOW ${sus_head}MC2_MASTER_OVERFLOW`
ERROR: C1:IOO-MASTER_OVERFLOW value not read
0
op440m:WFS>echo "tdsread ${sus_head}MC1_MASTER_OVERFLOW ${ioo_head}MASTER_OVERFLOW ${sus_head}MC2_MASTER_OVERFLOW"
tdsread C1:SUS-MC1_MASTER_OVERFLOW C1:IOO-MASTER_OVERFLOW C1:SUS-MC2_MASTER_OVERFLOW
op440m:WFS> |
This is the same bug described in entry 180. I believe it has nothing to do with tdsread, which did not change in the time period before the bug appeared, but perhaps has something to do with other EPICS libraries somewhere (tdsread relies on these epics libraries to do its dirty work). Here is entry 180 for reference:
Quote: | tdsread has developed a strange new illness, whereby it cannot read EPICS values from two subsystems at once (e.g., getting an LSC and SUS value simultaneously). I thought this might have something to with the fact that both losepics and iscepics are running on the same box,
but the same thing happens with IOO EPICS records, so that's not the culprit.
This is new behaviour, and it's only happening on the solaris machines. I suspect some ENV/cshrc juju has caused it, as the tdsread executable is the same one from April, and I don't think our EPICS infrastructure has changed otherwise. In the near term we can either try running the scripts on linux, or modify the IFO scripts to not do these types of calls. |
The solution that's been in effect for the past few months has just been to modify the scripts to not make these kinds of calls. |
432
|
Mon Apr 21 12:58:42 2008 |
rob | Update | ASS | check adaptive |
Quote: |
Caryn Palatchi (a Caltech undergrad who just started working with us)
illustrated to me today that using even 1000 FIR taps is not very effective
for low frequency noise cancellation if you have a 2048 Hz sample rate. More
precisely, the asymptotic Wiener filter which our 'LMS' algorithm converges
to, can often amplify the noise at frequencies below f_sample/N_taps.
A less obvious thing that she also noticed is that there is almost no cancellation
of the 16.25 Hz bounce mode when using such a short filter. That's because that
mode is fairly high Q: the transfer function from the Z-ACC to the cavity signal
goes through the high-Q vertical suspension resonance; the FF signal we send back
goes through the low-Q horizontal pendulum response only. Therefore the filter
needs to be able to simulate ~100 cycles at 16.25 Hz in order to cancel that peak.
Duh.
The message here is: we need to find a computationally efficient way to do FIR filtering
or its not going to ever be cool enough to help us find the Crab. |
This is the reason for "RDNSAMP" parameter in the ASS code. The FIR filtration is applied at the downsampled rate, not the machine rate. So, if RDNSAMP=32, the effective sampling rate of the FIR filter is 64Hz, and thus noise cancellation should be good down to 64Hz/1000, or 64mHz, and the filter has an impulse response time that extends to 15 secs. I'm not convinced the filter length is what's limiting the performance at the bounce mode, but I agree that a faster FIR implementation would be good. |
431
|
Sun Apr 20 23:39:57 2008 |
rana | Summary | SUS | MC1 electronics busted |
I spent some time trying to fix the utter programming fiasco which was our MCWFS diagonalization script.
However, it still didn't work. Loops unstable. Using the matrix in the screen snapshot is OK, however.
Finally, I realized from looking at the imaginary part of the output matrix that there was something
wrong with the MC1 drive. The attached JPG shows TFs from pit-drives of the MC mirrors to WFS1.
MC1 & MC3 are supposed to have 28 elliptic low pass filters in hardware for dewhitening. The MC2
hardware is different and so we have given it a software 28 Hz ELP to compensate. But it looks like
MC1 doesn't have the low pass (no phase lag). I tried switching its COIL FM10 filters to make it
switch but no luck.
We'll have to engage the filters to make the McWFS work right and to get the MC noise down. This
needs someone to go check out the hardware I think.
I have turned the gain way down and this has stabilized the MC REFL signal as you can see from the StripTool screen. |
430
|
Sun Apr 20 20:29:46 2008 |
rana | Update | Computer Scripts / Programs | tdsread bugs |
There seems to be a problem with reading the C1:IOO-MASTER_OVERFLOW field
when it is read in as part of an array. The only way for me to describe it
is to just attach the terminal output in this entry...this is mainly for
Matt and Rob.
I first noticed that the output of the MC-WFS sensing matrix was different than
the outputs from a year ago, namely that the excitation channel was not being
processed and outputted to the file. This made the output matrix diagonalization
scripts fail.
I noticed that there are several different copies of tdsread.cc sitting around.
Looks like they have been hacked in the last year but I am not sure if this
excitation channel readback is an intentional change; email has been sent to the
authors to find out -- they will probably post some kind of response in the log
to resolve what's up.
My guess is that the problem with the IOO channel is not related, but I'm not sure:
op440m:WFS>set ioo_head = "${ifo}:IOO-"
op440m:WFS>set sus_head = "${ifo}:SUS-"
op440m:WFS>set oflows = `tdsread ${sus_head}MC1_MASTER_OVERFLOW ${sus_head}MC2_MASTER_OVERFLOW ${sus_head}MC3
_MASTER_OVERFLOW ${ioo_head}MASTER_OVERFLOW`
ERROR: C1:IOO-MASTER_OVERFLOW value not read
op440m:WFS>set oflows = `tdsread ${sus_head}MC1_MASTER_OVERFLOW ${sus_head}MC2_MASTER_OVERFLOW ${ioo_head}MAS
TER_OVERFLOW`
ERROR: C1:IOO-MASTER_OVERFLOW value not read
op440m:WFS>set oflows = `tdsread ${ioo_head}MASTER_OVERFLOW`
op440m:WFS>set oflows = `tdsread ${sus_head}MC1_MASTER_OVERFLOW ${ioo_head}MASTER_OVERFLOW`
ERROR: C1:IOO-MASTER_OVERFLOW value not read
op440m:WFS>set oflows = `tdsread ${sus_head}MC1_MASTER_OVERFLOW ${ioo_head}MASTER_OVERFLOW ${sus_head}MC2_MASTER_OVERFLOW`
ERROR: C1:IOO-MASTER_OVERFLOW value not read
op440m:WFS>echo $oflows
0
op440m:WFS>set oflows = `tdsread ${ioo_head}MASTER_OVERFLOW`
op440m:WFS>echo $oflows
0
op440m:WFS>set oflows = `tdsread ${sus_head}MC1_MASTER_OVERFLOW ${sus_head}MC2_MASTER_OVERFLOW ${sus_head}MC3_MASTER_OVERFLOW`
op440m:WFS>echo $oflows
0 0 0
op440m:WFS>echo `tdsread ${sus_head}MC1_MASTER_OVERFLOW ${ioo_head}MASTER_OVERFLOW ${sus_head}MC2_MASTER_OVERFLOW`
ERROR: C1:IOO-MASTER_OVERFLOW value not read
0
op440m:WFS>echo "tdsread ${sus_head}MC1_MASTER_OVERFLOW ${ioo_head}MASTER_OVERFLOW ${sus_head}MC2_MASTER_OVERFLOW"
tdsread C1:SUS-MC1_MASTER_OVERFLOW C1:IOO-MASTER_OVERFLOW C1:SUS-MC2_MASTER_OVERFLOW
op440m:WFS> |
429
|
Sun Apr 20 18:23:27 2008 |
rana | Summary | LSC | locking attempts |
I noticed that the adaptive FF for the MC had stopped doing anything; this turned out
to be that the MC lost lock and the mcdown script turned off the FF path to MC1.
Although there's no elog, it looks like there was ~60 attempts at locking the IFO
between 12:38 and 4:27 on Saturday afternoon. I'm attaching here a plot showing
lock attempt durations and a histogram of lock times. |
428
|
Fri Apr 18 19:46:08 2008 |
rana | Update | ASS | check adaptive |
I restarted the adaptive code today using 'startass' and 'upass'.
I moved them into the scripts/ASS/ subdirectory.
Things seem OK. With a MU=0.03 and a TAU=0.00001, there is a still
a good factor of 10 reduction of the 3 Hz stack peak from the MC2
drive by doing FF into MC1.
I edited the ASS-TOP screen so that we could see such small numbers. I
also re-aligned the MC SUS to match the input beam (mainly MC3). The
cavity was locking on a TEM10 mode mostly -- we should look in the SUS
OSEM trends to see if MC3 has moved a lot in the last month or so.
Caryn Palatchi (a Caltech undergrad who just started working with us)
illustrated to me today that using even 1000 FIR taps is not very effective
for low frequency noise cancellation if you have a 2048 Hz sample rate. More
precisely, the asymptotic Wiener filter which our 'LMS' algorithm converges
to, can often amplify the noise at frequencies below f_sample/N_taps.
A less obvious thing that she also noticed is that there is almost no cancellation
of the 16.25 Hz bounce mode when using such a short filter. That's because that
mode is fairly high Q: the transfer function from the Z-ACC to the cavity signal
goes through the high-Q vertical suspension resonance; the FF signal we send back
goes through the low-Q horizontal pendulum response only. Therefore the filter
needs to be able to simulate ~100 cycles at 16.25 Hz in order to cancel that peak.
Duh.
The message here is: we need to find a computationally efficient way to do FIR filtering
or its not going to ever be cool enough to help us find the Crab. |
427
|
Fri Apr 18 16:48:13 2008 |
Andrey | Update | PEM | Rain collector of weather station |
Today the rain collector of our weather station was cleaned. As a result, we checked that the rain indication on the weather monitor and on the MEDM screens is alive and working properly. I am adding some details about the roof sensors to the wiki-40 page about the weather station. See especially the link "More description of the roof sensors and their interaction with UNIX computers" from the main Weather Station page in wiki-40.
Pictures of the rain collector before (dirty, the opening is fully clogged with dust and dirt) and after (clean opening in the bottom of the bowl) the cleaning are attached. |
426
|
Fri Apr 18 16:27:04 2008 |
rob | Update | SUS | end station sus front-end bug fix |
Quote: | installed and started new susEtmx.o and susEtmy.o to fix a problem with ETMY optical lever variables. |
But where is the code? |
425
|
Fri Apr 18 16:02:58 2008 |
alex | Update | SUS | end station sus front-end bug fix |
installed and started new susEtmx.o and susEtmy.o to fix a problem with ETMY optical lever variables. |
424
|
Thu Apr 17 20:17:37 2008 |
Andrey | Update | PEM | Two issues with our weather station |
I encountered two difficulties working with the "Weather Station".
(1) It turns out that there is no indication for "outside humidity" on the "weather monitor" (a small black box located on the north wall of the interferometer). I realized that "outside humidity" is absent in our system when I tried to see the Dataviewer trend and real-time value from the channel "C1: PEM-weather-outsideHumid". It shows impossible number 128%.
It follows from the "Davis" technical documentation that the outside sensor can be of two types: either "External Temperature Sensor" or "External Temperature/Humidity Sensor". I suspect (I do not know for sure) that we have the first type of sensor "external temperature only" and therefore we in principle cannot have information about outside humidity. I propose to Steve to climb to the roof on Friday to resolve this uncertainty looking at the sensor.
(2) I wanted to change the units of pressure from "Pascal" (force/area) to other units, "mbar" for example. For this purpose I need to edit the file "Weather.st" in the directory /cvs/cds/caltech/target/c1pem1 (this file is run on the VME processor "c1pem1"). Unfortunately, when I try to open the file with emacs, I get the message that the file exists but protected from modifications. I do not know how to unblock the file "Weather.st". I need some help with that.
I thought that switching-off the processor "c1pem1" could resolve the issue, so I switched-off the whole crate where the processor "c1pem1" is installed for about 5 minutes, turning the metallic key. As it did not make any difference for the accessibility of the file "Weather.st", I switched-on the crate after 5 minutes. There are other processors besides "c1pem1", so they were turned-off for several minutes earlier today.
Also, I created a new MEDM screen which has information about weather only, a smaller version of the "C0Checklist.adl" MEDM screen. Both screens are now located under the most top-left button "Checklist" of the main MEDM screen. |
423
|
Thu Apr 17 15:00:59 2008 |
steve | Update | VAC | vac controller computer to be replaced |
Now that Rosalba is up and running someone should step forward to volunteer for this job.
Old desk top at the Vacuum Rack should be replaced by a functional less old computer so
the vacuum controller can count on an emergency situation. It's only has to be able to run medm
The existing one is dying. |
422
|
Wed Apr 16 21:11:12 2008 |
rana | Summary | DAQ | AA/AI Filters for the DAQ & FE systems |
I used Foton to make up some new filters which will be used all over the project in order to downsample/upsample.
There will be 2 flavors:
- The first one will be a downsampling filter for use in the DAQ system.
Whenever you specify a sampling rate in the .ini files below the natural rate of the ADC,
the data will be downsampled using this filter (called ULYAW_0 in the plot). This one was
designed for flat bandpass and a 'good' bandstop but no care given to the phase shift.
- The second one will be used in the FE systems to downsample the ADC signal which is often
sampled at 64 kHz down to something manageable like 2k or 16k. This one was tweaked for
getting less phase lag in the 'control' band (usually 3x or so below Nyquist).
Here is the associated filter file:
# SAMPLING ULYAW 16384
# DESIGN ULYAW 0 zpk([0.512+i*1024;0.512-i*1024;2.048+i*2048;2.048-i*2048], \
# [515.838+i*403.653;515.838-i*403.653;318.182+i*623.506;318.182-i*623.506;59.2857+i*827.88; \
# 59.2857-i*827.88],0.988553,"n")
# DESIGN ULYAW 1 zpk([0.512513+i*1024;0.512513-i*1024;1.53754+i*2048;1.53754-i*2048], \
# [200+i*346.41;200-i*346.41;45+i*718.592;45-i*718.592],1,"n")
# DESIGN ULYAW 2 zpk([0.768769+i*1024;0.768769-i*1024;1.53754+i*2048;1.53754-i*2048], \
# [194.913-i*331.349;194.913+i*331.349;53.1611+i*682.119;53.1611-i*682.119],1,"n")
### ###
ULYAW 0 21 3 0 0 DAQAA 0.00091455950698073 -1.62010355523604 0.67259370084279 -1.84740554170818 0.99961738977942
-1.72089534598832 0.78482029284220 -1.41321371411946 0.99858678588255
-1.85800352005967 0.95626992044093 2.00000000000000 1.00000000000000
ULYAW 1 21 2 0 0 FEAA 0.018236566955641 -1.83622978049494 0.85804776530302 -1.84740518752455 0.99961700649533
-1.89200532023258 0.96649324616546 -1.41346289594856 0.99893883979950
ULYAW 2 21 2 0 0 ELP 0.015203943102927 -1.84117829296043 0.86136943504058 -1.84722827171918 0.99942556512240
-1.89339022414279 0.96048849609619 -1.41346289594856 0.99893883979950
|
421
|
Wed Apr 16 10:20:01 2008 |
Andrey | Update | Computers | Rosalba and linux3 |
Quote: | There is a new computer in the control room -- its called Rosalba,
in keeping with our naming convention. Its a quad-core machine that
Dmass found for cheap somewhere; we've installed the CentOS on it
that Alex recommended.
Its a 64-bit Linux and so that may cause some problems. Alex has done this
before and so we have some confidence that we can get our regular tools (DTT, Dataviewer)
to run on it.
I have made a new apps tree for all of our future 64-bit Linux machines. So far, there is
a 64-bit firefox and a 64-bit matlab in there. As we start using this machine some more, we
will be forced to install more 64-bit Linux stuff.
We also didn't have enough network cables to run to both linux3 and rosalba. Andrey has decided that we
should not ditch linux3 and so he will run another cable for it tomorrow. |
The ethernet cable for linux3 was installed on Wednesday morning. Now linux3 has Internet connection again. |
420
|
Wed Apr 16 09:47:35 2008 |
Andrey | Summary | PEM | Weather Station |
The weather station is functional again.
The long ethernet Cat5 cable connecting 'WeatherLink' and processor 'c1pem1' was repaired yesterday, namely the RJ45 connector was replaced,
and information about weather conditions is now again continuously being transferred from the 'Weather Monitor' to the control UNIX computers. We can see this information in 'c0Checklist.adl' screen and in Dataviewer.
Below are the two sets of trends for the temperature, wind speed and direction, pressure and the amount of precipitation.
The upper set of trends ("Attachment 1") is "Full Data" in Dataviewer for the 3 hours from 6.30AM till 9.30AM this morning,
and the lower set of trends ("Attachment 2") is "Minute Trend" in Dataviewer for 15 hours from 6.30PM yesterday till 9.30AM this morning.
I also updated the wiki-40 page describing the Weather Station and added to there a description of the process of attaching the RJ45 connector to the end of ethernet Cat5 cable. To access the wiki-40 page about the "weather station" you should go from the main page to "PEM" section and click on "Weather Station". |
419
|
Tue Apr 15 18:44:25 2008 |
rana | Configuration | Computers | Rosalba |
There is a new computer in the control room -- its called Rosalba,
in keeping with our naming convention. Its a quad-core machine that
Dmass found for cheap somewhere; we've installed the CentOS on it
that Alex recommended.
Its a 64-bit Linux and so that's going to cause some problems. Alex has done this
before and so we have some confidence that we can get our regular tools (DTT, Dataviewer)
to run on it.
I have made a new apps tree for all of our future 64-bit Linux machines. So far, there is
a 64-bit firefox and a 64-bit matlab in there. As we start using this machine some more, we
will be forced to install more 64-bit Linux stuff.
We also didn't have enough network cables to run to both linux3 and rosalba. Andrey has decided that we
should not ditch linux3 and so he will run another cable for it tomorrow. |
418
|
Tue Apr 8 09:08:54 2008 |
steve | Configuration | PEM | weather station disconnected |
We can not leave cables in the walkways and go on vacation.
I disconnected the weather station from the DAQ
Every Tuesday is janitor day in the 40m.
We have to give him free space for doing a good job.
Burned toast award goes to Andrey. |
417
|
Mon Apr 7 18:58:49 2008 |
steve | Update | General | reflectivity of SS304 |
The reflectivity of stainless steel 304 super polished # 8 was measured the same way as elog entry 409
The reflectivity: 74 +- 1 % from incident angle 10 to 80 degrees |
416
|
Mon Apr 7 16:42:56 2008 |
rana | Update | Computers | eLog intermittent |
Phil Ehrens restarted Dziban again this morning. Looks like its still crashing each Monday around 8 AM.
Here is the latest suspect:
http://open.itworld.com/5040/reboot-unix-nlsunix-071225/page_1.html |
414
|
Fri Apr 4 16:54:06 2008 |
Andrey | Summary | Environment | Weather station is fully alive |
After today's trip to the roof of our building the weather station seems to be completely resurrected!
We went to the roof together with Steve Vass, and we discovered that:
(1) Sensors of wind speed, wind direction and the bowl that measures the amount of precipitation do not have any visible defects, so there is no problem with all those sensors even after being outside for seven years.
(2) We discovered that there are cable junctions located on the roof, and those junctions were located close to the rim (edge) of the roof, before the cables go inside of 40-meter lab room. The taping in the place of the junction was not good due to the age, and the connections between the cables were disrupted (cable endings were out of the connectors). Therefore, no signal from the roof sensors could be transferred to the 'Weather Monitor'. It was not wise from the person who installed the weather station to leave the fragile cable connections outside, on the roof, because the length of the cables allowed to locate those three connectors inside of the building.
See the attached PDF-file with pictures.
(3) After the cables were plugged into the connectors, these cable junctions were gently pulled into the inside of the 40-meter interferometer room. These cable junctions should not be located outside of the building!
Immediately after all the above-mentioned steps, the reasonable indications of outside temperature, humidity, pressure, wind speed and direction appeared on the 'Weather Monitor'.
In order to see if there is any problem of communication between the 'Weather Monitor' and UNIX control computers through 'c1pem1', I rolled out two brand new black cat-5 ethernet cables on the floor of the interferometer room (they are on the floor temporarily, the ethernet cable will go from the floor into the ceiling cable tray eventually), connected the two cables together through freshly purchased from Caltech bookstore cable connectors, and thus connected the 'Weather Monitor' to the processor 'c1pem1'.
Result: Now we can see reasonable indications of outside temperature, pressure, amount of precipitation, wind speed and direction on the EPICS screen! Moreover, these indications are changing with time.
As a reminder for everyone: standard atmospheric pressure is about 101kPa, so the indications of pressure as 99900Pa is quite reasonable.
One thing is not clear for me yet: wind speed on the 'Weather Monitor' is fluctuating between 2 and 4 mph, while MEDM EPICS-screen values are fluctuation in the range between 0 and 3mph.
Many thanks to Steve Vass and Alexander Ivanov for their help. |
413
|
Thu Apr 3 19:27:50 2008 |
Andrey | Summary | Photos | Tour for prospective grad students |
Last Friday (March 28), there was a tour of 40-meter lab for prospective graduate students.
Rana showed to the prospective students the interferometer. See pdf-attachment with pictures (two pictures of Rana with undergraduates (I took them) and two old pictures which I discovered on the memory card of Nikon d-40, it was not me who took those two last pictures). |
412
|
Thu Apr 3 18:46:04 2008 |
Andrey | Configuration | Computers | "Network switch board" and "c1pem1 crate" were touched |
While working with the weather station, I did two things that potentially (with a very small probability) might influence the smooth work of other processors/computers.
I did the following on Wednesday, April 2nd, in times between 1PM and 3PM.
(1) I turned off for several seconds and returned into the initial position the switch-key on the rack with computer (processor) 'c1pem1' in order to reboot processor 'c1pem1'. The turning off/on of that key-switch was repeated several times.
(2) I pulled gently the whole "Network-Switch Board" towards me in order to replace an ethernet cat 5 cable going into the board form the processor 'c1pem1'. Some other connections of other ethernet cables might be flimsy, and then other people in 40-meter might have problems with computers other than 'c1pem1'. It should not happen, but in case of extraordinary behaviour of any other computer in our lab, people should check the connectors on the network-switch board. It is located near the middle of Y-arm. See picture. |
410
|
Thu Apr 3 18:33:17 2008 |
Andrey | Summary | Environment | Status of Weather Station |
During the last two days some things related to weather station have been improved.
1) Startup file for the computer (processor) 'c1pem1' was changed so that now 'c1pem1' can be rebooted from "Linux1". Computer 'c1pem1' is responsible for communicating data between 'Weather Monitor' and control UNIX machines. Before April 1st it was impossible to reboot the computer 'c1pem1'. Now 'c1pem1' runs without difficulties.
2) It was determined that some ethernet cables of category "cat 5" were bad. I replaced one short cat 5 cable between 'c1pem1' and 'network-switch board' in the neighboring computer rack, and I still need to replace the internet ending of another long (~20 meters) cat 5 cable after Alex Ivanov will bring the tool for that.
3) 'Weather monitor' and 'WeatherLink' are temporarily moved away from their "nested" positions on the north wall, and they are now in the proximity of processor 'c1pem1'. Thus the signal about "Inside Temperature" goes into 'c1pem1' computer without any additional ethernet cables, and "inside temperature" is correctly displayed on the "Checklist" adl. MEDM screen on the control UNIX machines. The cable with a signal from the roof sensors (which might be dead due their 7-year age) is temporarily disconnected from the 'Weather Monitor'.
Result: 'Weather Monitor' and computer (processsor) 'c1pem1' are alive, they communicate reasonable "Inside Temperature" to the control UNIX-machines.
The fate of the outside sensors is currently unknown, I plan to go to the roof together with Mr. Steve Vass tomorrow and try to determine what should be done with them.
I am also writing (right now) a wiki-40 page which explains what is the "Weather Station" and what is its status. |
409
|
Wed Apr 2 15:03:51 2008 |
steve | Update | General | reflectivity of black glass |
The reflectivity of black glass, shade 12 was supplied by Donald O'Shea
of Emerald Glass Inc., Westlake, OH 44145
The reflectivity of this glass was measured as shown
Old 1064 nm Crysta Laser with poor beam quality was the source. |
408
|
Mon Mar 31 14:14:16 2008 |
rob | Update | Computers | c1susvme2 status |
Quote: | c1susvme2 is getting worse and worse. it won't run for more than ~45 minutes without fatally de-syncing. for now I've turned off c1iovme (which sends the MCL signal) to see if that's causing the problem. next I'll swap the boards for c1susvme1 and c1susvme2 to see if it's the cpu (or maybe the RFM card) itself, rather than the timing/pentek systems. |
I swapped the processors for c1susvme1 and c1susvme2. So for now, to startup, you should ssh into c1susvme1 and run the startup.cmd for c1susvme2, and vice versa. |
407
|
Mon Mar 31 14:01:40 2008 |
jamie | Summary | LSC | Summary of DC readout PD non-linearity measurements |
From March 21-26, I conducted some measurements of the response non-linearity of some mock-up DC readout photodetectors. The detectors are simple:
Vbias ---
|
PD
|-------- output
resistor
|
---
-
This is a description of the final measurement.
The laser current modulation input was given a 47Hz sine wave at 20mV. A constant small fraction of the beam was shown onto the reference detector, and a beam that was varied in DC power level was incident on the test detector. Spectra were taken from both detectors at the same time, 0.25Hz bandwidth, over 100 averages.
At each incident power level on the test detector, the Vpk in all multiples of the modulation frequency were measured (ie. V[i*w]). The difference between the 2f/1f ratio in the test and reference was then calculated, ie:
V_test[2*w]/V_test[1*w] - V_ref[2*w]/V_ref[1*w]
This is the solid black line in the plot ("t21-r21_v_power.png").
The response of a simulated non-linear detector was also calculated based on the Vpk measured at each harmonic in the reference detector, assuming that the reference detector had a purely linear response, ie:
V_nl[beta,2*w]/V_nl[beta,1*w] - V_l[2*w]/V_l[1*w]
these are the dashed colored lines in the plot ("t21-r21_v_power.png").
The result of the measurement seems to indicate that the non-linearity in the test detector is less than beta=-1.
The setup that was on the big optics table south of the laser, adjacent to the mode cleaner, is no longer needed. |
406
|
Fri Mar 28 16:18:18 2008 |
rob | Update | Computers | c1susvme2 status |
c1susvme2 is getting worse and worse. it won't run for more than ~45 minutes without fatally de-syncing. for now I've turned off c1iovme (which sends the MCL signal) to see if that's causing the problem. next I'll swap the boards for c1susvme1 and c1susvme2 to see if it's the cpu (or maybe the RFM card) itself, rather than the timing/pentek systems. |
405
|
Wed Mar 26 22:26:15 2008 |
John | Update | Computers | c1susvme |
I removed the fan and tweaked the timing cables to see if they were the source of our problems. I saw no effect. I'm leaving the fan off for the moment to see if that helps. It is on top of the filing cabinet next to my desk. |
404
|
Wed Mar 26 13:41:53 2008 |
Andrey | HowTo | SUS | Modification of ''C1DRIFT_MONITOR'' |
I learned how to modify the drift-monitor in MEDM so that values on it change colors from green to yellow to red depending how much is the fluctuatioin (deviation) of the value from its mean nominal value.
In order to do this, I used the following eight commands:
tdswrite CHANNEL_NAME.HIHI VALUE
tdswrite CHANNEL_NAME.HIGH VALUE
tdswrite CHANNEL_NAME.LOW VALUE
tdswrite CHANNEL_NAME.LOLO VALUE
tdswrite CHANNEL_NAME.HHSV 2
tdswrite CHANNEL_NAME HSV 1
tdswrite CHANNEL_NAME LSV 1
tdswrite CHANNEL_NAME LLSV 2
where CHANNEL_MAME is the name of the channel the value of which is indicated on the MEDM screen C1DRIFT_MONITOR, for example
C1:SUS-MC1_SUSPOS_INMON, and VALUE is numerical value that I assigned to the channel parameters.
By now I modified nine mode-cleaner channels (POS, PITCH and YAW channels for MC1, MC2 and MC3) and 6 channels for ITMX and ITMY.
Note that as we have problems this week with computer C1SUSVM, namely ''c1susvme2'' is not working, indicators for MC2 in the drift-monitor do not change colors today although they should.
In order to judge which values should be established as reasonable deviations from the average nominal values, I was looking into Dataviewer trends for the channels that are in the drift-monitor.
In the future indicators for channels ETMX and ETMY, BS, PRM, SRM should be modified in complete analogy with what I did already for MC and for ITM. So, I have modified 3*5 = 15 channels, and 3*5 = 15 channels are left for the future.
Note that (as far as I understand) instead of commands "tdswrite" it is absolutely legitimate to use commands "ezcawrite". |
403
|
Tue Mar 25 16:34:47 2008 |
rob | Update | Computers | c1susvme2 |
Quote: |
Quote: | c1susvme2 isn't behaving itself. It keeps getting out of sync and/or giving a red status light.
After going through the usual restart procedures a few times (unsuccessfully) we power cycled the c1susvme & c1sosvme crates. We think everything came back okay.
We still can't get the status and CRC (cyclic redundancy check) to return to normal on c1susvme2. If Alex is around tomorrow please ask him to take a look. |
I rebooted it again this morning. The ASS machine is currently not running its process, for whatever reason (someone turn it off?). Let's leave it like this for a day and see how the c1susvme2 does. The other recent change is Steve's install of a cooling fan--maybe that's causing the problem. |
Now c1susvme1 is joining the action. Since leaving the ASS off doesn't change anything, we can probably absolve it of blame. I now suspect the 4-pin LEMO cables going from the CLK DRIVER modules to the clock fanout modules. These cables are being squeezed/shaken by Steve's new fan setup, and may have been the culprit all along. John will do some testing to see if they are indeed the problem. |
402
|
Tue Mar 25 15:56:09 2008 |
John | Update | Treasure | Assorted pictures |
Some pictures scavenged from the D40. |
401
|
Tue Mar 25 13:21:25 2008 |
Andrey | Update | Computers | c1susvme2 is not behaving itself again |
|
400
|
Tue Mar 25 10:44:24 2008 |
rob | Update | Computers | c1susvme2 |
Quote: | c1susvme2 isn't behaving itself. It keeps getting out of sync and/or giving a red status light.
After going through the usual restart procedures a few times (unsuccessfully) we power cycled the c1susvme & c1sosvme crates. We think everything came back okay.
We still can't get the status and CRC (cyclic redundancy check) to return to normal on c1susvme2. If Alex is around tomorrow please ask him to take a look. |
I rebooted it again this morning. The ASS machine is currently not running its process, for whatever reason (someone turn it off?). Let's leave it like this for a day and see how the c1susvme2 does. The other recent change is Steve's install of a cooling fan--maybe that's causing the problem. |
399
|
Mon Mar 24 20:15:03 2008 |
John | Summary | Computers | c1susvme2 |
c1susvme2 isn't behaving itself. It keeps getting out of sync and/or giving a red status light.
After going through the usual restart procedures a few times (unsuccessfully) we power cycled the c1susvme & c1sosvme crates. We think everything came back okay.
We still can't get the status and CRC (cyclic redundancy check) to return to normal on c1susvme2. If Alex is around tomorrow please ask him to take a look. |
398
|
Mon Mar 24 13:03:54 2008 |
rob | Update | Electronics | HP4195A is back |
Quote: | The swept sine output looks totally normal from 500Mhz to 150MHz (measuring ~220mVrms below 300MHz -- 0dBm), where it abruptly transitions to a distorted waveform which the scope measures as having a frequency of ~25MHz and with 450mVrms (+6dBm). It then transitions again at some other part of the sweep to a cleaner-looking 25MHz waveform with ~1.2Vrms (+15dBm). |
The HP4195A is back from repair. At first, it exhibited exactly the same behaviour for which it was sent in for repair, and which is described above (pillage from entry 337). After speaking with the repair tech on the phone, who tried to imply that the digital scope was tricking us, I plugged the output into our HP8591E spectrum analyzer, just to have firm ammunition to combat the repair guy's looniness. This led to even weirder behaviour, like no output and overload signals on the inputs (with nothing connected). After turning the unit on and off several times, and firmly seating (and screwing in) the DB9 connectors in the back of the unit, it appears to be working properly. Except for a brief glitch as it passes through 150MHz, the swept sine signal now appears normal, both on the scope and in the spectrum analyzer.
Apparently the whole thing is due to a loose connection somewhere in the box, which wasn't actually fixed by the repair, but has at least been temporarily fixed by me stumbling around with a screwdriver and then pushing the power button a couple of times. |
397
|
Sun Mar 23 10:42:54 2008 |
Valera | Summary | Electronics | RFAM of the RF stabilization box is measured |
I reconstructed Tobin's setup to measure the RFAM after the RF stabilization box in the 166 MHz modulation path.
The setup consisted of the splitter and the mixer followed by the RF low pass filter and the SR560 (gain x100).
The RF level into splitter was 20 dBm. The Mini-Circuits ZLW-3H (17 dBm LO) mixer was used. The LO was taken
straight out of the splitter and the RF path was attenuated by 11 dBm, The DC out of the mixer was 700 mV.
The noise floor was measured with the RF input of the mixer terminated on 50 Ohm. The 45 MHz measurement
in broad band setting looks better than the noise floor at high frequencies. I am not sure what was wrong with
one or both of those measurements. The 9 MHz measurements are above the noise floor.
The RFAM meets the AdvLIGO requirements in the detection band (f > 10 Hz).
The attached zipped files are:
SRS003 9 MHz DC-200 Hz
SRS004 9 MHz DC-26 kHz
SRS006 45 MHz DC-200 Hz
SRS005 45 MHz DC-26 kHz
SRS007 Noise floor DC-200 Hz
SRS008 Noise floor DC-26 kHz |
396
|
Sun Mar 23 00:56:42 2008 |
John | Update | LSC | More on 3f |
We ended our last attempt at 3f locking concerned about the beam size on PD6. I investigated tonight. The beam was not obviously overfilling the diode and a quick tweak of the steering mirror revealed a decent plateaux. Nevertheless we decided to try a different approach to see if we found the same problems as before on a different diode.
This time our 3f diode was Refl 33. I put a splitter on the output of the diode at the LSC rack sending one half into the usual refl 33 board, the other into refl DD 199 (which is demodulating at 99Mhz).
I got as far as handing off PRC to the 3f signal in lock. More work needed. |
395
|
Sun Mar 23 00:43:08 2008 |
mevans | HowTo | General | Online Adaptive Filtering |
I wrote a short document about the OAF running on the ASS. Since there is no BURT setup, I put a script in /cvs/cds/caltech/scripts to help with setting initial parameters: upass. |
394
|
Sat Mar 22 22:39:02 2008 |
mevans | Summary | CDS | Direct Form 2 filters are bad |
Here I show a comparison between the filter algorithm currently used in LIGO (Direct Form II), and an alternative algorithm designed to reduce numerical noise. The input signal is
x = sin(2 * pi * t) + 1e-9 * sin(2 * pi * (fs / 4) * t);
where fs = 16384 is the sample rate. The filter is a 4th order notch at 1Hz (f_poles = f_zeros = 1Hz, Q_poles = 1, Q_zeros = 1e6). It is clear that the DF2 algorithm produces a noise floor that is, for this simple filter, 1e-11 / rtHz smaller than the input drive amplitude (see plots). That should probably be scary given how many second-order-sections we run our signals through. The low-noise form does a somewhat better job. The low-noise algorithm has the same memory and computational requirements as DF2, and our CDS guys have the code in hand. I suggest we start testing soon.
(The code is included below. You will need my Matlab library to run the top level test script.) |
392
|
Fri Mar 21 23:17:47 2008 |
rana | Configuration | DMF | seisBLRMS restarted |
I updated the seisBLRMS par file with the new channel names of the accelerometers and the seismometer and then
recompiled the code and restarted it according to Rob's elog entry. It went fine and the seisBLRMS is now back in
action. |
391
|
Fri Mar 21 23:15:11 2008 |
rana | Configuration | PEM | Ranger SS-1: New Setup |
The Ranger seismometer has been in a bad state. Its output had been sent into a SR560 without any termination.
The seismometer is, internally, just a mass on a flexure with a magnet and a pickup coil for readout.
The damping of the system depends on the resistor hooked up across the coil. With the SR560 this is
the 1 Meg input impedance of it and so the mass is undamped.
I installed a 4300 Ohm resistor in there which seems to nearly critically damp it. However, this will not
allow us to reach the ultimate quantum noise limited performance. We will have to analyze the thermal, voltage,
and current noise to get that.
I then also increased the gain from 10 to 100 on the SR560. This should now make the front end noise of the
seismometer/SR560 close to equal to the noise of the PEM ADC. |
390
|
Fri Mar 21 17:01:21 2008 |
rana | Configuration | DMF | Locale change on Mafalda & seisBLRMS restart |
Ever since we moved the accelerometers to be around the MC and changed their names, the seisBLRMS
has not been working. I tried to restart it today after fixing the channel names in the par file
but I ran into a PERL / UBUNTU bug.
perl: warning: Setting locale failed.
perl: warning: Please check that your locale settings:
LANGUAGE = (unset),
LC_ALL = (unset),
LC_TIME = "en_US.ISO8859-1",
LC_MONETARY = "en_US.ISO8859-1",
LC_CTYPE = "en_US.ISO8859-1",
LC_COLLATE = "en_US.ISO8859-1",
LC_MESSAGES = "C",
LC_NUMERIC = "en_US.ISO8859-1",
LANG = "en_US.UTF-8"
are supported and installed on your system.
perl: warning: Falling back to the standard locale ("C").
I don't know how this crept up or when it started. There were a bunch of fixes on the Ubuntu
forums which didn't work.
In the end I just set the 'unset' environment variables via our cshrc.40m file and this seemed
to make ligotools/perl happy. Lets hope this lasts...I love Linux. |
389
|
Fri Mar 21 11:54:38 2008 |
rob | Update | VAC | tp 2 failed |
Quote: | Small turbo #2 is the forepump of the maglev.
It failed last night, shut down the maglev and interlock closed V1
Ifo pressure is 20 mTorr now. The Yarm was still locked at 8am this morning.
The PSL beam to MC was blocked just before the output periscope.
The psl mechanial shutter did not work from epic screen. |
The PSL mechanical shutter actually did trip last night, greatly confusing me and Rana. Not realizing that the software vacuum interlock had tripped, we manually re-opened the shutter. I'll modify the relevant MEDM screens to indicate when the EPICS interlock trips. |
388
|
Fri Mar 21 09:02:03 2008 |
steve | Update | VAC | tp 2 failed |
Small turbo #2 is the forepump of the maglev.
It failed last night, shut down the maglev and interlock closed V1
Ifo pressure is 20 mTorr now. The Yarm was still locked at 8am this morning.
The PSL beam to MC was blocked just before the output periscope.
The psl mechanial shutter did not work from epic screen. |
387
|
Thu Mar 20 17:45:36 2008 |
rana | Summary | ASS | Adaptive Filtering in the ASS system |
Over the past couple weeks we (Matt, Alex, Rob, me) have worked on getting an adaptive filter
system working. We wanted to load this system into c1ass to use this processor. The dither alignment
system hasn't been employed here for awhile and so we have just used this box.
The signals are acquired in the PEM ADCU. Alex modified the code there to send the signals over to
the new system. We also get the SUS-LSC_OUT signals from each of the suspensions so that we can
try to minimize them.
The outputs of the adaptive filter go into the unused SUS-MCL inputs of all the suspensions (except
for MC2). In the current setup, we have 6 accelerometers and 1 seismometer around the MC to be used
to demonstrate the principle of the whole thing.
Much more documentation and description of everything is necessary. We'll try to get Matt, Rob, and Alex
to use the elog. |
386
|
Thu Mar 20 16:06:27 2008 |
rob | Configuration | LSC | LSC code change |
I changed the LSC code again. I noticed that when turning off the LSC (e.g., going from LA to OFF), the cpu time would jump from ~50 to ~80, and irrevocably de-sync all the SUS controllers. This was because turning off the LSC would suddenly zero the inputs to the decimation filters that send information to the ASS box, which for some reason greatly increases the computation time of the iir filter function call. I changed the code so that these inputs are never zeroed. The ASS receives inputs from the LSC all the time now.
I also noticed that the ASS machine was running in ~2400 usec. Yes, 2,400 microseconds. I don't know how long it's been doing that, but I restarted it. Immediately after restart, it ran at 1700 microseconds. After using the "RESET" field in the adaptOnline code, that dropped to ~100 usec. Now it's not doing any adaptive filtering, as I don't know what the good settings are and no-one has been elogging their IFO work the last few days. |
385
|
Thu Mar 20 15:28:20 2008 |
steve | Update | VAC | tp2 's drypump replaced |
The fore pump of tp2 was replaced at fore line pressure 998m Torr |
384
|
Mon Mar 17 18:30:48 2008 |
mevans | Configuration | PEM | Adaptive Filtering |
It seems that adaptive filtering can achieve results similar to those of the MISO FIR Wiener (entry 369). The adaptive code simulates real-time operation, but uses the same data used by Rana for the Wiener filter. I ran the adaptive filter over the data 100 times to ensure that it was well trained... maybe too well. |
383
|
Sun Mar 16 17:03:32 2008 |
rob | Configuration | CDS | ASS code change |
I've updated the ass.mdl file in the directory:
/cvs/cds/caltech/users/alex/cds/advLigo/src/epics/simLink/
to get us started in the adaptive PEM noise subtraction.
After several iterations of remote help from Alex, the code compiles and runs, receives signals from the LSC, PEM, and MC2, and communicates with the suspension controllers. I've also adapted the .par file from the code generator, but haven't got the testpoints working with the new ASS code. There are no MEDM screens yet, and Matt's adaptive filter code has not been installed (there's a matrix as a placeholder).
Putting in the adaptive code should be simple, building the MEDM screens tedious, and getting the testpoints working uncertain. I noticed that the new testpoint.par file starts at a different channel number than the previous (working) version, which is strange. I probably have a script somewhere to change all these numbers by a constant offset, but I don't know if that's the actual problem--maybe stuff just needs to be rebooted.
The code receives as input the first 24 channels from the PEM ADCU, the eight suspension control signals from the LSC, and the output of the MCL filter from MC2. It outputs to the MCL filter input of each suspension (except MC2). |