  887   Tue Aug 26 15:06:16 2008 steveConfigurationVACrga scanPumpdown 66 PRM-maglev vac normal -day 11
short form: pd66PRM-m-d11
 RGA-0808260125.png 
  886   Tue Aug 26 12:00:45 2008 JenneSummaryPEMTransfer function of Ranger seismometerThis finishes up the calibration that Rana
started in elog # 881.
  
  885   Tue Aug 26 09:58:59 2008 steveOmnistructureCOCETMX is #03This is the picture of ETMX from the upper
south west viewport
 etmx-d40posg_012.jpgetmx03.jpg 
  884   Tue Aug 26 09:04:59 2008 ranaConfigurationPSLPMC Servo Board: Out for RepairsI've started modifying our PMC board to bring
it up to the 21st century - [B][COLOR=blue]leave
the screen alone[/COLOR][/B] or else you
  
  883   Mon Aug 25 21:15:23 2008 ranaConfigurationLSCaux NPRO off[FONT=Comic Sans MS][COLOR=purple]Looks like
no one has used the Lightwave NPRO on the
AS table after Koji left, so I turned it
  
  882   Mon Aug 25 17:45:34 2008 rana, josephb, robHowToPEMAccelerometer rangeJoe shows us by jumping up ~15" in the control
rom that the accelerometers are set with
not enough gain.
 Screenshot-4.png 
  881   Mon Aug 25 15:50:18 2008 ranaSummaryPEMRanger SS-1The manual for the Ranger SS-1 seismometer
can be found on line here:
[URL=ftp://ftp.kmi.com/pub/software_manuals/300190/300190nc.pdf]ftp://ftp.kmi.com/pub/software_manuals/300190/300190nc.pdf[/URL]
  
  880   Mon Aug 25 14:42:09 2008 EricConfigurationCamerasETMX Digital CameraI changed the lens on the camera looking at
the ETMX to a 16mm, 1:1.4 zoom lens.  This
is in preparation to measure a couple parameters
  
  879   Mon Aug 25 14:18:36 2008 JenneUpdatePSLPMC servo board is fixedThe PMC servo board is back in place, all
fixed up with a shiny new resistor.  The
PMC locks, and the MC locks (I'm not saying
  
  878   Mon Aug 25 12:13:49 2008 JenneUpdatePSLBroken PMC Servo Board[SIZE=3]I broke the PMC servo board[/SIZE]
(on accident).
  
  877   Mon Aug 25 11:43:55 2008 YoichiFrogsIOOMC REFL PD cable had been disconnected through out the weekendMost of my morning was wasted by the MC REFL
PD cable, which was disconnected on the generic
LSC PD interface board.
  
  876   Mon Aug 25 10:51:06 2008 steveUpdatePSLpsl headtemp is coming downThe laser water cooler was overflowing this
morning.
I removed 500 cc water from the chiller.
 ht4dw.jpg 
  875   Mon Aug 25 10:23:53 2008 steveHowToGeneralcable killerRack 1Y7 double violation:

BNC cables left to be jammed by door
 cablkill.pngcablkll2.png 
  874   Mon Aug 25 10:07:35 2008 JenneUpdatePSLNumbers for the PMC servo board (Re: entry # 873)Jenne, Rana

These are the numbers that go along with
  
  873   Sat Aug 23 09:39:51 2008 rana, jenneUpdatePSLPMC SurveyJenne, Rana

We scoped out the PMC situation yesterday.
  
  872   Fri Aug 22 17:03:41 2008 YoichiUpdateIOOMC open loop TFI measured the open loop TF of the overall
MC loop using the sum-amp A of the MC board.
I used the Agilent 4395A network analyzer
  
  871   Fri Aug 22 16:06:29 2008 steveUpdatePEMparticle counter replaced, flowbenches & HEPAs checkedMetOne #2 counter was swapped in (on the top
of IOC, facing SW direction, at ~75 deg upwards)
with channel one size 0.3 micron and channel
  
  870   Fri Aug 22 13:58:39 2008 SharonSummary Trend of the Wiener TFIn order to understand if we really need an
adaptive filter, I used old data of MC_L
and the accelerometers and seismometer to
 Same_start_time1.pdfsame_length.pdf 
  869   Fri Aug 22 10:39:41 2008 JenneUpdateSUSTaking Free Swinging spectra of PRM, SRM, ITMX, BSI'm taking free swinging spectra of PRM, SRM,
ITMX and BS, so I've turned off their watchdogs
for now. I should be done around 11:15am,
  
  868   Thu Aug 21 18:13:24 2008 ranaUpdateIOOMC WFS Control signals not responsible for lock lossesThis is a 4 hour, second-trend of the MC WFS
error and control signals.
 Untitled.png 
  867   Thu Aug 21 17:55:14 2008 ranaHowToIOOMC WFS DC OffsetsI ran the McWFS_dc_offsets script to trim
out the DC offsets on the MC WFS DC signals.
  
  866   Thu Aug 21 16:28:59 2008 steveConfigurationSAFETYsafety glasses required I just opened the MOPA shutter so PA is warming
up.
  
  865   Thu Aug 21 10:24:20 2008 steveConfigurationSAFETYlaser safe mode conditionThe MOPA and PSL shutters are closed.
Manual beam blocks are in place.
Enclosure interlock is enabled.
  
  864   Wed Aug 20 18:09:48 2008 YoichiUpdateIOOMC still unlocksBeing suspicious of FSS PC path as the culprit
of the MC unlocks, I opened the FSS box and
connected a probe to the TP7, 
 MC-unlock.png 
  863   Wed Aug 20 17:02:01 2008 SharonUpdate More FIR to IIR I tested another method for converting from
FIR to IIR other than the 2 mentioned in
post 841.
 polefit1.pdf 
  862   Wed Aug 20 13:23:32 2008 robUpdateLockingDRMI locked
I was able to lock the DRMI this afternoon.
 All the optical levers have been centered.
  
  861   Wed Aug 20 12:39:11 2008 EricSummaryCamerasWeekly SummaryI attempted to model the noise produced by
the mirror defects in the ETMX images, in
order to better assure that the fit to the
 OriginalSignImage.pngModifiedSignImage.pngOriginalTVImage.pngModifiedTVImage.png 
  860   Wed Aug 20 12:04:47 2008 JenneUpdateSUSBetter diagonalization of PRM input matrixThe values here should replace those in entry
#851 from yesterday.
 PRM_Eigmodes_shihori.pngPRM_Eigmodes_sonia.png 
  859   Wed Aug 20 11:50:10 2008 JohnSummaryComputersStripTools on op540m[SIZE=5][FONT=Comic Sans MS]
To restart the striptools on op540m:
  
  858   Wed Aug 20 11:42:49 2008 JohnSummaryComputerspdftkI've installed pdftk on all the control room
machines.
  
  857   Tue Aug 19 19:14:17 2008 YoichiConfigurationDAQFixed C1:IOO-MC_RFAMPDDCYoichi, Rob

C1:IOO-MC_RFAMPDDC, which is a PD at the
  
  856   Tue Aug 19 18:55:41 2008 YoichiUpdateIOOMC unlock study updateIn entry 849, I reported that the MC transmitted
power drops before the sudden unlocks. 
However, because C1:IOO-MC_TRANS_SUM is a
 MC-unlock.png 
  855   Tue Aug 19 17:15:34 2008 SharonUpdate MEDMI plugged in the gains I got for the accelerometers
in the accelerometers' filters in the PEM
screen of the adaptive filter
  
  854   Tue Aug 19 17:00:19 2008 SharonUpdate Wiener TF calibration - update[I]This is an update for post 814[/I]

I added the calibration gains I got for the
 m_per_m.png 
  853   Tue Aug 19 14:25:38 2008 SharonUpdatePEMAccelerometer's calibration - update[COLOR=blue][B]Goal[/B][/COLOR] - Make sure
the accelerometers are calibrated among themselves
(have the same power spectrum when they are
 acccalibafter.pngacccalibbefore.png 
  852   Tue Aug 19 13:34:58 2008 josephbConfigurationComputersSwitched c1pem1, c0daqawg, c0daqctrl over to new switchesMoved the Ethernet connections for c1pem1,
c0daqawg, and c0daqctrl over to the Netgear
Prosafe switch in 1Y6, using new cat6 cables.
  
  851   Tue Aug 19 13:12:55 2008 JenneUpdateSUSDiagonalized PRM Input Matrix[SIZE=2][COLOR=blue]NOTE:  Use the values
in elog #860 instead (20Aug2008)[/COLOR][/SIZE]
  
  850   Tue Aug 19 10:36:34 2008 SharonUpdate Calibrating accelerometersI took apart the accelerometers near MC1 and
MC2.
The 2 sets of 3 accelerometers are now covered
  
  849   Mon Aug 18 22:47:12 2008 YoichiUpdateIOOMC unlock studyAs rob noted, the MC keeps unlocking in a
few minutes period.
I plotted time series of several signals
 MC-Unlock.png 
  848   Mon Aug 18 17:37:14 2008 robUpdateLockingrecovery progress
I removed the beam block after the PSL periscope
and opened the PSL shutter.
 flatlissa.png 
  847   Mon Aug 18 15:32:18 2008 josephbConfigurationCamerasHow to multicast with gstreamer and Gige CamerasIn order to get multicasting to work, one
simply needs to understand the address scheme.
  
  846   Mon Aug 18 11:50:29 2008 YoichiUpdateSUSIn vacuum free swinging resultsThe first attachment is the results of the
free swinging spectra measurement performed
in vacuum this morning.
 2008-8-18.pdfspike.pdf 
  845   Mon Aug 18 09:19:55 2008 steveSummaryVAC11 days at atmIt took 11 days to fix earth quake triggered
sus problems of ITMX, SRM and PRM
Only ITMX north and BSC north vac doors were
 ventprm.jpg 
  844   Mon Aug 18 08:07:10 2008 YoichiConfigurationSUSSuspension free swingingI've started a free swinging measurement of
OSEM spectra now. Please leave the watchdogs
untouched.
  
  843   Fri Aug 15 19:32:49 2008 steveConfigurationVACpumpdown completeI have just reached vacuum normal. The maglev
peaked at 49.8C body temp with aux fan on
at 3.2 Torr
 pdprm.jpg 
  842   Fri Aug 15 17:38:41 2008 YoichiUpdateSUSOSEM free swinging spectra before the pump downI ran an overnight measurement of the free
swinging OSEM spectra.
The attm1 shows the results. Everything look
 2008-8-15.pdfITMY2.pdf 
  841   Fri Aug 15 16:45:43 2008 SharonUpdate Converting from FIR to IIRI have been looking into different techniques
to convert from FIR to IIR. This is so we
can see how effective the adaptive FIR filter
 fir2iir50.pngfir2iir400.pngfir2iir1000.png 
  840   Fri Aug 15 14:12:31 2008 steveBureaucracySAFETYsafety glasses required The MOPA shutter is opened,
the PSL enclosure is switched to bypass mode,
manual block removed from PMC,
  
  839   Fri Aug 15 11:52:32 2008 josephbConfigurationCamerasMulti-computer display and recording of digital camera outputThrough the magic of gstreamer, I've been
able to live play on one machine, compress
the image, send it to another machine via
  
  838   Thu Aug 14 21:52:51 2008 KojiSummaryGeneralAbs. Len. Meas. ~ summary of my SummerI have made the summary of the absolute length
measurement.
It is attached here. The file is a bit big
 mode_spacing_measurement_080816_v2.pdf 
ELOG V3.1.3-