40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 326 of 335  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Dateup Author Type Category Subject Text Attachments
  16393   Tue Oct 12 11:32:54 2021 YehonathanSummarySUSPRM and BS Angular Actuation transfer function magnitude measurementsLate submission (From Thursday 10/07):

I measured the PRMI sensing matrix
to see if the BS and PRMI output matrices
 modified_output_matrices_radar_plots.pngnormal_output_matrices_radar_plots.png 
  16394   Tue Oct 12 16:39:52 2021 ranaSummarySUSPRM and BS Angular Actuation transfer function magnitude measurementsshould compare side by side with the ITM
PRMI radar plots to see if there is a difference.
How do your new plots compare with Gautam's
  
  16395   Tue Oct 12 17:10:56 2021 AnchalSummaryCDSSome more informationChris pointed out some information displaying
scripts, that show if the DAQ network is
working or not. I thought it would be nice
  
  16396   Tue Oct 12 17:20:12 2021 AnchalSummaryCDSConnected c1sus2 to martian networkI connected c1sus2 to the martian network
by splitting the c1sim connection with a
5-way switch. I also ran another ethernet
  
  16397   Tue Oct 12 23:42:56 2021 KojiSummaryCDSConnected c1sus2 to martian networkDon't you need to add the new
hosts to /diskless/root/etc/rtsystab at fb1?
--> There looks many elogs talking about
  
  16398   Wed Oct 13 11:25:14 2021 AnchalSummaryCDSRan c1sus2 models in martian CDS. All good!Three extra steps (when adding
new models, new FE):


Chris
pointed out that the sudo command in c1sus2
 CDS_screens_running.png 
  16399   Wed Oct 13 15:36:38 2021 HangUpdateCalibrationXARM OLTFWe did a few quick XARM oltf measurements.
We excited C1:LSC-ETMX_EXC with a broadband
white noise upto 4 kHz. The timestamps for
 Screenshot_2021-10-13_15-32-16.png 
  16400   Thu Oct 14 09:28:46 2021 YehonathanUpdatePSLPMC unlockedPMC has been unlocked since ~ 2:30 AM.
Seems like the PZT got saturated. I moved
the DC output adjuster and the PMC locked
  
  16401   Thu Oct 14 11:25:49 2021 YehonathanUpdatePSLPMC unlocked{Yehonathan, Anchal}

I went to get a sandwich around
10:20 AM and when I came back BS was moving
 BS_OSEM_Sensor_PSD.pdfBS_OSEM_Sensor_PSD_AfterReconnectingCables.pdf 
  16402   Thu Oct 14 13:40:49 2021 YehonathanSummarySUSPRM and BS Angular Actuation transfer function magnitude measurementsHere is a side by side comparison of the
PRMI sensing matrix using PRM/BS actuation
(attachment 1) and ITMs actuation (attachment
 BSPRM_Actuation_Radar_plots.pngITM_Actuation_Radar_plots.png 
  16403   Thu Oct 14 16:38:26 2021 Ian MacMillanUpdateGeneralKicking optics in freeSwing measurment[Ian, Anchal]

We are going to kick the optics
tonight at 2am.
  
  16404   Thu Oct 14 18:30:23 2021 KojiSummaryVACFlange/Cable Stand ConfigurationFlange Configuration for BHD

We will need total 5 new
cable stands. So Qty.6 is the number to be
 40m_flange_layout_20211014.pdf 
  16405   Thu Oct 14 20:16:22 2021 YehonathanUpdateGeneralPRMI free swinging{Yehonathan, Raj}

We aligned the IFO in the PRMI
state and let it swing freely.
  
  16406   Fri Oct 15 12:14:27 2021 Ian MacMillanUpdateGeneralKicking optics in freeSwing measurment[Ian, Anchal]

we ran the free swinging test last
night and the results match up with in 1/10th
 20211015_Kicktest_plot.pdf 
  16407   Fri Oct 15 16:46:27 2021 AnchalSummaryOptical LeversVent PrepI centered all the optical levers on ITMX,
ITMY, ETMX, ETMY, and BS to a position where
the single arm lock on both were best aligned.
 Screen_Shot_2021-10-15_at_4.34.45_PM.pngScreen_Shot_2021-10-15_at_4.45.31_PM.pngScreen_Shot_2021-10-15_at_4.34.45_PM.pngScreen_Shot_2021-10-15_at_4.34.45_PM.png 
  16408   Fri Oct 15 17:17:51 2021 KojiSummaryGeneralVent PrepI took over the vent prep: I'm going
through the list in [ELOG
15649] and [ELOG
 7x 
  16409   Fri Oct 15 20:53:49 2021 KojiSummaryGeneralVent PrepFrom
the IFO point of view, all look good and
we are ready for venting from Mon Oct 18
  
  16410   Mon Oct 18 10:02:17 2021 KojiUpdateVACVent Started / Completed[Chub, Jordan, Anchal, Koji]

- Checked the main volume is isolated.
- TP1 and TP2 were made isolated from
 Screen_Shot_2021-10-18_at_14.52.34.pngScreenshot_2021-10-18_15-08-59.png 
  16411   Mon Oct 18 16:48:32 2021 TegaUpdateElectronicsSat Amp modifications[S2100738, S2100745, S2100751] Completed
three more Sat Amp units modification with
seven remaining.
 IMG_20211018_162918574.jpg 
  16412   Tue Oct 19 10:59:09 2021 KojiUpdateVACVent Started / Completed[Chub, Jordan, Yehonathan, Anchal,
Koji]

North door of the BS chamber opened
  
  16413   Tue Oct 19 11:30:39 2021 KojiUpdateVACHow to vent TP1I learned that TP1 was vented through the
RGA room in the past. This can be done by
opening VM2 and a manual valve ("needle
 Screen_Shot_2021-10-18_at_14.52.34.png 
  16414   Tue Oct 19 18:20:33 2021 Ian MacMillanSummaryCDSc1sus2 DAC to ADC testI ran a DAC to ADC test on c1sus2 channels
where I hooked up the outputs on the DAC
to the input channels on the ADC. We used
 data3_Plots.pdfdata2_Plots.pdf 
  16415   Tue Oct 19 23:43:09 2021 KojiSummaryCDSc1sus2 DAC to ADC test(Because of a totally unrelated reason)
I was checking the electronics units for
the upgrade. And I realized that
 P_20211019_224433.jpgP_20211019_224122.jpgP_20211019_224400.jpgP_20211019_224411.jpg 
  16416   Wed Oct 20 11:16:21 2021 AnchalSummaryPEMParticle counter setup near BS ChamberI have placed a GT321 particle counter
on top of the MC1/MC3 chamber next to the
BS chamber. The serial cable is connected
 PXL_20211020_183728734.jpg 
  16417   Wed Oct 20 11:48:27 2021 AnchalSummaryCDSPower supple configured correctly.This was horrible! That's my bad, I
should have checked the configuration before
assuming that it is right.
  
  16418   Wed Oct 20 15:58:27 2021 KojiUpdateVACHow to vent TP1Probably the hard disk of c0rga is dead.
I'll follow up in this elog later today.

Looking at the log in /opt/rtcds/caltech/c1/scripts/RGA/logs
  
  16419   Thu Oct 21 11:38:43 2021 JordanUpdateSUSStandoffs for Side Magnet on 3" Adapter Ring SOS AssemblyI had 8 standoffs made at the Caltech chemistry
machine shop to be used as spacers for the
side magnets on the 3" Ring assembly.
 Magnet_Standoffs.jpg 
  16420   Thu Oct 21 11:41:31 2021 AnchalSummaryPEMParticle counter setup near BS ChamberThe particle count channel names were changes
yesterday to follow naming conventions used
at the sites. Following are the new names:
 ParticleCountData20211021.pdf 
  16421   Thu Oct 21 15:22:35 2021 ranaSummaryPEMParticle counter setup near BS ChamberSVG doesn't work in my browser(s).
Can we use PDF as our standard for all graphics
other than photos (PNG/JPG) ?
  
  16422   Thu Oct 21 15:24:35 2021 ranaSummaryPEMParticle counter setup near BS Chamberrethinking what I said on Wednesday - its
not a good idea
to put the particle counter on a vac chamber
  
  16423   Fri Oct 22 17:35:08 2021 Ian MacMillanSummaryPEMParticle counter setup near BS ChamberI have done some reading about where would
be the best place to put the particle counter.
The ISO standard (14644-1:2015) for
  
  16424   Mon Oct 25 13:23:45 2021 AnchalSummaryBHDBefore photos of BSC[Yehonathan, Anchal]

On thursday Oct 21 2021, Yehonathan
and I opened the door to BSC and took some
  
  16425   Mon Oct 25 17:37:42 2021 AnchalSummaryBHDPart I of BHR upgrade - Removed optics from BSC[Anchal, Paco, Ian]


Clean room etiquettes


Two
people in coverall suits, head covers, masks
 rn_image_picker_lib_temp_44cb790a-c3b4-42aa-8907-2f9787a02acd.jpgrn_image_picker_lib_temp_0fd8f4fd-64ae-4ccd-8422-cfe929d4eeee.jpg 
  16426   Tue Oct 26 10:17:14 2021 YehonathanUpdateBHDSOS assemblyThings that I need to start suspending
optics:

1. Winch adapter plate (D970314).
  
  16427   Tue Oct 26 13:27:07 2021 TegaSummaryElectronicsSat Amp modification SummaryModifications and testing of SatAmp
units COMPLETE. Attachments 1 & 2 show
all 19 units, one installed unit and the
 SapAmpModStack.jpgSatAmpInstalled.jpg 
  16428   Tue Oct 26 14:53:24 2021 KojiUpdateElectronicsRack1. We have a rack at the 40m storage. We
are free to take it to the lab. If there
is a tag, tell the info to Liz. Let's
 P_20211026_143814.jpg 
  16429   Tue Oct 26 16:56:22 2021 PacoSummaryBHDPart I of BHR upgrade - Locked PMC and IMC[Paco, Ian]

We opened
  
  16430   Tue Oct 26 18:24:00 2021 Ian MacMillanSummaryCDSc1sus2 DAC to ADC test[Ian, Anchal, Paco]

After the Koji found that there
was a
 data2_Plots.pdfdata3_Plots.pdf 
  16431   Wed Oct 27 16:27:16 2021 AnchalSummaryBHDPart II of BHR upgrade - Prep[Anchal, Paco, Ian]

Before we could start working on
Part II, which is to relocate TT2 to new
 OMCNorthBefore.jpegOMCNorthAfter.jpeg 
  16432   Wed Oct 27 16:31:35 2021 AnchalSummaryBHDPart III of BHR upgrade - Removal of PR2 Small SuspensionI went inside the ITMX Chamber to read
off specs from PR2 edge. This was required
to confirm our calculations of LO power for
  
  16433   Wed Oct 27 16:38:02 2021 AnchalSummaryBHDPart II of BHR upgrade - Relocation of TT2 and MMT1/2 alignment[Anchal, Paco]

We opened BSC and Injection Chamber
doors. We removed two stacked counterweights
  
  16434   Wed Oct 27 18:11:37 2021 KojiSummaryBHDPart II of BHR upgrade - Relocation of TT2 and MMT1/2 alignmentClosed the PSL shutter @18:11
During the vent, we want to keep the
cavity unlocked if not necessary.
  
  16435   Wed Oct 27 18:16:45 2021 KojiSummaryBHDPart II of BHR upgrade - Relocation of TT2 and MMT1/2 alignment- Moving the MMT2 south by a cm is fine.
This will give you ~0.5cm at TT1 without
changing the other alignment much.
  
  16436   Wed Oct 27 19:34:52 2021 KojiSummaryElectronicsNew electronics racks1. The rack we cleaned today (came from
West Bridge) will be placed between 1X3 and
1X4, right next to 1X4 (after removing the
 P_20211027_180737.jpgP_20211027_180443.jpgP_20211027_180408.jpgP_20211027_180139.jpg 
  16437   Thu Oct 28 16:32:32 2021 PacoSummaryBHDPart IV of BHR upgrade - Removal of BSC eastern optics[Ian, Paco, Anchal]

We turned off the BSC oplev laser
by turning the key counterclockwise. Ian
  
  16438   Thu Oct 28 17:01:54 2021 AnchalSummaryBHDPart III of BHR upgrade - Adding temp fixed flat mirror for PR2[Anchal, Paco, Ian]


We added a Y1-2037-0 mirror
(former IPPOS SM2 mirror) on a fixed mount
  
  16439   Thu Oct 28 23:13:19 2021 YehonathanUpdateBHDSOS assembly{Tega, Yehonathan, Koji}

Suspension
 OpLev_Setup.jpgsuspended_optic.png20211029_113011.jpg20211029_113052.jpg 
  16440   Fri Oct 29 14:39:37 2021 AnchalSummaryBHD1Y1 cleared. IY3 ready for C1SUS2 I/O and FE.[Anchal, Paco]

We cleared 1Y1 rack today removing
the following items. This stuff is sitting
 RemovedStuff.jpeg1Y1.jpeg1Y3.jpeg 
  16441   Sun Oct 31 14:21:31 2021 ranaHowToTreasureIFOCadIFOcad model/video of the AEI 10m interferometer:

https://10m.aei.mpg.de/design-and-sensitivity/
  
  16442   Mon Nov 1 14:51:34 2021 KojiUpdateGeneralChecking the vent planThe vent team described
a detailed vent plan (and reports where the
actions have been performed)
  
ELOG V3.1.3-