40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 326 of 346  Not logged in ELOG logo
ID Date Author Type Category Subjectdown Text Attachments
  13867   Fri May 18 19:59:55 2018 Jon RichardsonConfigurationElectronicsAUX-PSL PLL Characterization MeasurementsBelow is analysis of measurements
I had taken of the AUX-PSL PLL using an SR560
as the servo controller (1 Hz single-pole
 SR560_OL.pdfSR560_CL.pdf 
  14085   Thu Jul 19 01:56:25 2018 gautamSummaryVACAUX pump shutdown[koji,
gautam]

Per Steve's instructions, we
  
  13900   Thu May 31 02:04:55 2018 johannesUpdatePSLAUX laser state of mindThe AUX laser is down to 5.4 mW output
power 
 IMG_20180530_220058190.jpg 
  13948   Tue Jun 12 03:22:25 2018 gautamUpdateLSCAUX laser shutteredI worked a bit on recovering the DRMI locking
again tonight. I decided to shutter the AUX
laser on the PSL table at least until I figured
  
  14501   Fri Mar 29 15:47:58 2019 gautamUpdateAUXAUX laser fiber moved from AS table to PSL table[anjali, gautam]

To facilitate the 1um MZ frequency
stabilization project, I decided that the
  
  14504   Sun Mar 31 18:39:45 2019 AnjaliUpdateAUXAUX laser fiber moved from AS table to PSL table

Attachment #1 shows the schematic
of the experimental setup for the frequency
noise measurement of 1 um laser source.
 Schematic_of_experimental_setup_for_frequency_stabilisation_of_1_micron_source.png1_micron_setup_for_frequency_noise_measurement.JPG1_micron_setup_for_frequency_noise_measurement_power_levels.png 
  13834   Fri May 11 18:17:07 2018 gautamUpdateDetCharAUX laser PLL setup[koji,
gautam]

As discussed at the meeting earlier
  
  14045   Sun Jul 8 22:27:25 2018 keerthanaUpdate AUX diagram(Analisa, Keerthana, Sandrine)

So far we tried four different
techniques to scan the AUX laser. They are,
 PLL-single_demodulation.pdfPLL-double_demodulation.pdf 
  13987   Tue Jun 19 18:56:55 2018 JonUpdateGeneralAUX beam alignment issuesNot much progress today with the AUX cavity
scans. I've determined there still are
some alignment issues.
  
  13989   Wed Jun 20 00:57:04 2018 johannesUpdateGeneralAUX beam alignment issuesWe did swap a lens as discussed in elog 13968,
but they both had f=100mm specified, the
difference being one was AR-coated for 1064
 as110_rf_30MHz.pdfyend_rf_30MHz.pdf 
  14013   Sun Jun 24 23:13:46 2018 johannesUpdateGeneralAUX beam alignment issuesAt some point we want to change the AUX
injection on the AS table to interfere less
with the normal interferometer path, and
 AS_AUX_SETUP.pdf 
  13968   Thu Jun 14 22:45:05 2018 johannesUpdateGeneralAUX beam SRC alignment[Jon, Gautam, Johannes]

Jon spent some time trying to align
the AUX beam to the SRC today, I got to the
  
  10299   Wed Jul 30 18:09:08 2014 HarryUpdateGeneralAUX and PSL Coupling Telescopes Purpose
These telescopes will be used to
mode match//couple the dumped SHG light from
 PSLTelescope.pngAUXTelescope.pngtelescopes.zipAUXTelescopePlot.pngPSLTelescopePlot.png 
  11924   Sat Jan 9 00:39:15 2016 gautamUpdateLSCAUX Y Freq Noise re-measured


 AuxPLL.pdf 
  11921   Fri Jan 8 14:47:33 2016 ericqUpdateLSCAUX Y Freq Noise measuredHere are some results from measuring the
PSL / AUX Y beat. 

With the Y end laser, I was able
 AUX_freqnoises.pdfAUXY_Jan8.zip 
  11922   Fri Jan 8 20:02:49 2016 ranaUpdateLSCAUX Y Freq Noise measuredUnless this is the limit from the way you
guys set up the PLL, it seems like there's
no difference between the two lasers that's
  
  10894   Tue Jan 13 13:22:54 2015 JenneUpdateGeneralAUX Y + PSL beat note at 1064nm: needs workI'm super excited about this new frequency
readback, but I'm
  
  10895   Tue Jan 13 14:01:20 2015 manasaUpdateGeneralAUX Y + PSL beat note at 1064nm: needs work


  
  10883   Fri Jan 9 14:01:17 2015 manasaUpdateGeneralAUX Y + PSL beat note at 1064nmI
worked around the PSL table today.

The Y+PSL output from the optical
  
  10893   Tue Jan 13 10:28:02 2015 manasaUpdateGeneralAUX Y + PSL beat note at 1064nm


  
  11936   Tue Jan 19 17:27:58 2016 gautamUpdateGreen LockingAUX X power investigationsLast week, Eric and I noticed that the
green transmission levels at the PSL table
seem much lower now than they did a month
 X_END_POWER_BUDGET.JPG 
  10996   Tue Feb 10 16:01:21 2015 manasaUpdateGeneralAUX X fiber coupled 72%Plan
C finally worked. We have
 AUXxTelescope.png 
  11894   Mon Dec 21 02:29:49 2015 ericqUpdateLSCAUX X RIN measurementsI'll finish up the beat / frequency
noise parts of the diagnosis tomorrow
later, but I've done some investigation
 auxXRIN.pdf 
  11619   Fri Sep 18 11:59:08 2015 ericqUpdateLSCAUX X Laser Current RevertedOnce again, the transmitted X green beam
was showing enormous intensity fluctuations
(50x higher than normal). Last month, I reduced the
  
  11533   Thu Aug 27 02:09:14 2015 ericqUpdateLSCAUX X Laser Current ChangedI spent some time tonight chasing down
the cause of huge RIN in the X green PDH
transmitted light, which I had started seeing
  
  13325   Thu Sep 21 01:32:00 2017 gautamUpdateALSAUX X Innolight AM measurement running[rana,gautam]

We set up a measurement of the
AUX X laser AM today. Some notes:
 Innolight_AM.pdfInnolight_AM.tar.gzIMG_7599.JPG20170921_203741_TFAG4395A_21-09-2017_115547_FourSquare.pdf 
  11917   Thu Jan 7 04:28:39 2016 ericqUpdateLSCAUX X Freq Noise measured[ericq, Gautam]

Brief summary of tonights work:


Locked Marconi to AUX X
 PLLspec.pdfPLL_OLG.pdf 
  11919   Thu Jan 7 16:52:32 2016 ericqUpdateLSCAUX X Freq Noise measuredHere is some of the promised data. As mentioned,
changing diode current and crystal temperature
didn't have much effect on the frequency
 AUXfreqnoise.pdfauxXmeasurements.zip 
  11920   Thu Jan 7 19:04:25 2016 KojiUpdateLSCAUX X Freq Noise measuredThe next step is to compare this data with
the same measurement with the PSL and the
AUX laser on the PSL table (or the end Y
  
  11908   Tue Jan 5 02:54:38 2016 ericqUpdateLSCAUX X Freq Noise attempt[ericq, Gautam]

We set out to lock a marconi to
the IR fiber beat of PSL + AUX X to measure
  
  11910   Tue Jan 5 13:17:06 2016 ranaUpdateLSCAUX X Freq Noise attemptThe problem here is that the MC displacement
noise is leading to large frequency excursions
of the PSL beam. Options
  
  11912   Tue Jan 5 16:33:45 2016 ericqUpdateLSCAUX X Freq Noise attemptTurning on the MCL path (in addition to
the MCL FF we always have on) let me lock
the PLL for multiple seconds, but low frequency
  
  16933   Tue Jun 21 14:59:22 2022 CiciSummaryGeneralAUX Transfer Function Loop Exploration[Deeksha, Cici]

We learned about the auxillary
laser control loop, and then went into the
  
  17243   Tue Nov 8 11:18:39 2022 RadhikaUpdateAUXAUX PZT transfer function fitting + filteringHere I describe efforts to cancel the AUX
laser PZT mechanical resonances from ~200
kHz-400kHz. While these may not be the resonances
 AUX_PZT_TF_vectfit.pdfAUX_PZT_TF_filtered.pdf 
  17244   Tue Nov 8 16:56:33 2022 ranaUpdateAUXAUX PZT transfer function fitting + filteringThis looks really good to me. Rather than
fully invert the plant, what we would like
to do is now design a filter which allow
  
  16152   Fri May 21 12:12:11 2021 PacoUpdateNoiseBudgetAUX PDH loop identification[Anchal, Paco]

We went into 40m to identify where
XARM PDH loop control elements are. We didn't
  
  11715   Mon Oct 26 19:10:59 2015 gautamUpdateGreen LockingAUX PDH loop characterizationI began my attempts to characterize the
PDH loops at the X end today. My goal was
to make the following measurements:
  
  11351   Wed Jun 10 03:19:58 2015 ericqUpdateLSCAUX PDH error measured in CDSLooking over the old noise budget in the
green locking paper, it seems the main technical
noise sources were the AUX PDH error and
 AUXspectra.png 
  13994   Thu Jun 21 09:33:02 2018 JonUpdate AUX Mode Scans of YARM, PRC cavities[Jon, Keerthana, Sandrina]

Yesterday we carried out preliminary
proof-of-concept measurements using
 YARM_AUX_RF-offset_scan.pdftemp_broadband_refl33.pdf 
  10349   Thu Aug 7 17:09:53 2014 HarryUpdateGeneralAUX Coupling In Progress I'm currently in the process of coupling
dumped SHG light from the Y arm end table
into fibers for FOL.
  
  10360   Sun Aug 10 00:54:54 2014 HarryUpdateGeneralAUX CoupingThe Y End laser dumped SHG light has been
coupled into the yellow fiber that terminates
at the PSL table.
  
  14035   Tue Jul 3 11:59:10 2018 JonUpdateAUXAUX Carrier Scan of Y-Arm CavityI made the first successful AUX laser scan
of a 40m cavity last night.

Attachment #1 shows the measured
 yarm_carrier_trans.pdfAG4395A_02-07-2018_185504.txt 
  3442   Thu Aug 19 11:38:48 2010 AlastairUpdateComputersATF wikiThe ATF wiki page doesn't seem to be working
any more.  Does anyone know where this
is held so we can try to get it back online? 
  
  3443   Thu Aug 19 12:06:07 2010 AlastairUpdateComputersATF wiki


   
        
            
  
  8495   Fri Apr 26 10:50:07 2013 AnnalisaUpdateABSLATF laser on PSLThe ATF NPRO auxiliary laser has been moved
on the PSL table. All the optics for beat
note measurement are in place and alignment
  
  15315   Fri May 1 01:49:55 2020 gautamUpdateALSASY commissioningSummary:

It appears that the EY green steering
PZTs have somehow lost their bipolar actuation
  
  15316   Fri May 1 22:44:17 2020 gautamUpdateALSASY M2 PZT damagedI went to EY and saw that the HV power
supply was only putting out 50 V and had
hit the current limit of 10 mA (nominally,
  
  15317   Sat May 2 02:35:18 2020 KojiUpdateALSASY M2 PZT damagedYes, we are supposed to have a few spare
PI PZTs.
  
  14716   Mon Jul 1 20:27:44 2019 gautamUpdateASCASX tuningSummary:

To practise the dither alignment
servo tuning, I decided to make the ASX system
 ASX_ditherlines.pdfASX.png 
  9018   Fri Aug 16 13:25:50 2013 KojiUpdateASSASX model/screen cleaning up[Koji Manasa]
Yesterday we cleaned up the ASX model
and screens to have more straight forward
  
ELOG V3.1.3-