40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 325 of 348  Not logged in ELOG logo
ID Datedown Author Type Category Subject Text Attachments
  1181   Fri Dec 5 20:40:38 2008 YoichiHowToComputersElog multi-keyword searchThe current Elog search allows you to look
for only one keyword in the text.
You cannot search for two keywords by simply
  
  1180   Fri Dec 5 14:13:41 2008 ranaSummaryIOOMC trend for the last 4 days[COLOR=pink][SIZE=2][FONT=Comic Sans MS]The
MC has stayed locked for ~3 days! I just
broke it to reset the MZ.[/FONT][/SIZE][/COLOR]
 g.png 
  1179   Fri Dec 5 09:29:59 2008 ranaUpdateIOOdrum modes observable without excitationNot sure what the y-scale is since there aren't
any y axis labels in the plot, but it seems
like we
  
  1178   Fri Dec 5 01:58:58 2008 YoichiConfigurationASCtdscntr.pl now works at 40mTobin gave me the perl version of tdscntr
some time ago.
Pinkesh and I modified and tested it at LHO.
  
  1177   Fri Dec 5 01:41:33 2008 YoichiConfigurationComputersMEDM screen snapshot now works on linux machinesAs a part of my "make everything work on linux"
project, I modified 'updatesnap' script so
that linux machines can update MEDM screen
  
  1176   Thu Dec 4 17:42:23 2008 carynUpdateIOOdrum modes observable without excitationSo, the mode cleaner was evidently aligned
better and now the drum modes are observable
using DTT. 
 drum_modes.pdfdrum_modes2.pdf 
  1175   Thu Dec 4 16:29:20 2008 josephbConfigurationComputersError message on Frame Builder Raid ArrayThe Fibrenetix FX-606-U4 RAID connected to
the frame builder in 1Y7 is showing the following
error message: IDE Channel #4  Error Reading
  
  1174   Thu Dec 4 13:49:39 2008 JenneUpdatePEMMore of: Comparing Wiener subtraction using different sensorsHere is another version of the same type plot
I put in the elog yesterday.  This plot is
looking at the 7200 seconds after 04Dec2008
 Dec042008_c1wino_seisCombos.png 
  1173   Wed Dec 3 20:36:07 2008 Jenne, RanaUpdatePEMComparing Wiener subtraction with different seismometersThe Ranger has now been moved over to sit
underneath the MC2 tank (it was previously
close to the PSL rack). It
 d.pdfsco.pngfly.pdf 
  1172   Wed Dec 3 20:10:09 2008 Jenne, RanaUpdatePEMComparing Wiener subtraction with different seismometersAttached is a plot of MC_L, and then the residual
MC_L after static Wiener filtering, using
different combinations of our accelerometers
 Dec032008_c1wino_seisCombos.png 
  1171   Wed Dec 3 19:21:09 2008 ranaConfigurationPEMRanger moveI looked at the Ranger signals. [B]Somehow
it has a relative transfer function of 'f'
between it and the Guralp.[/B]
 c.pdfwsnb.pdf 
  1170   Wed Dec 3 12:49:11 2008 jenneUpdateComputerssomething sketchy with NDS ... or something[SIZE=2][COLOR=green]Never mind...I had forgotten
that you have to run mdv_config every time
you open matlab, not just every time you
  
  1169   Wed Dec 3 11:58:10 2008 AlbertoUpdatePSLMC AlignmentRana, Alberto,

more details on the MC alignment we did yesterday.
  
  1168   Tue Dec 2 19:51:32 2008 ranaUpdatePEMhalf-micron particle count is alarmingThe 0.5 micron dust monitor count is now pretty
high (36000). I wandered around the lab to
see if there was anything
 Untitled.pngdust.png 
  1167   Tue Dec 2 19:18:10 2008 ranaSummaryPEMRanger SS-1In entry http://dziban.ligo.caltech.edu:40/40m/881
and a follow up from Jenne I put in the Ranger
calibration.
  
  1166   Tue Dec 2 17:56:56 2008 Alberto, RanaConfigurationPSLMC AlignmentIn the attempt to maximize the Mode Cleaner
transmission and minimize the reflection
from the steering mirrors of the MC periscope,
  
  1165   Mon Dec 1 15:09:27 2008 robUpdatePEMhalf-micron particle count is alarming    
  1164   Thu Nov 27 22:56:42 2008 ranaConfigurationEnvironmenttemperature8-)  mc.png 
  1163   Tue Nov 25 19:29:15 2008 rana, alberto, johnConfigurationEnvironmenttemperature[quote]The PSL Room Temperature was alarming
because it had gone above 23 C. This set
off an unfortunate chain of events:
  
  1162   Tue Nov 25 18:38:03 2008 Alberto, RobUpdatePSLMC Periscope AlignmentThis morning when I came in I found the MC
cleaner unlocked and the autolocker script
could not lock it. The reflected beam was
  
  1161   Mon Nov 24 19:15:16 2008 rana, alberto, johnConfigurationEnvironmenttemperatureThe PSL Room Temperature was alarming because
it had gone above 23 C. This set off an unfortunate
chain of events:
  
  1160   Mon Nov 24 17:14:44 2008 ranaUpdatePSLMach Zender trendsIt looks like the MZ has gotten less drifty
after the alignment on Friday.
 Untitled.png 
  1159   Mon Nov 24 16:43:34 2008 ranaConfigurationComputersAlex and Jay took away some computers from the racksI was over at Wilson house and saw Jay and
Alex bring in 3 rackmount computers. One
was a Sun 4600 and
  
  1158   Sat Nov 22 10:55:51 2008 CarynConfigurationIOODrum modes Lock-In settings changedI unhooked the MC Demod Board's Qmon signal
from the Lock-In. Set the demodulation frequency
to 31.11Hz with 1V amplitude, and
  
  1157   Fri Nov 21 21:28:32 2008 ranaSummaryComputersc0daqawg restart[COLOR=green]A few minutes after restarting
fb0 for the Guralp channels, the DAQAWG lights
went red on the DAQ screens.[/COLOR]
  
  1156   Fri Nov 21 21:20:24 2008 ranaUpdatePEMGuralp noise measurementThis is the spectra and time series of the
Guralp channels along with the Ranger (MC2).
Looks like we could reduce the gain
 a.png 
  1155   Fri Nov 21 20:29:43 2008 rana, alberto, robUpdatePSLMach Zender alignment[quote] So now the MZ alignment seems good;
Alberto is on the MC periscope alignment
like a cheap suit.[/quote]
  
  1154   Fri Nov 21 19:47:26 2008 ranaUpdatePEMGuralp noise measurementand here's the spectra with them connected
- from the coherences, it looks like it needs
to be rotated by 90 deg.
 a.png 
  1153   Fri Nov 21 17:27:47 2008 JenneUpdatePEMGuralp noise measurementHere is the data from the Guralp Seismometer
for the past day or so, before I fixed the
VERT-1 channel.  The NS and EW show what's
 guralp_vert_shorted.jpg 
  1152   Fri Nov 21 16:52:48 2008 JenneUpdatePEMGuralp seismometer's Channel Problems are solvedPROBLEM noticed earlier this week:  It looked
like one of the seismometer channels (VERT-1)
wasn't working, no matter how I put which
  
  1151   Fri Nov 21 16:11:26 2008 rana, alberto, robUpdatePSLMach Zender alignmentThe Mach Zender's dark port DC voltage had
gone up too high (~0.5 V)and was turning
yellow
 PB210051-1.JPG 
  1150   Fri Nov 21 16:03:50 2008 ranaHowToGeneralRecharging BatteriesI found some black & red "Ninja" alkaline
AA batteries in the battery charger. [COLOR=red]This
is dangerous.[/COLOR] Please
  
  1149   Thu Nov 20 09:37:39 2008 steveUpdatePSLMZ vs tempThis 12 days plot shows that it can hold lock
if the daily temp variation is not more than
3/4 of a degree C
 mztemp.jpg 
  1148   Wed Nov 19 18:12:35 2008 ranaConfigurationIOOnew channel for MC drum modesI set up the lockin to take the MC Demod Board's
Qmon signal, demodulate it at 27.5 kHz, and
put the output into a DAQ channel (I think
  
  1147   Wed Nov 19 18:02:18 2008 ranaConfigurationElectronicsAll the Marconi Set to the Rubidium Frequency StandardNot sure what was going on before. I changed
the frequency counter to use an AC coupled
input, and had it average
  
  1146   Wed Nov 19 10:32:11 2008 AlbertoConfigurationElectronicsAll the Marconi Set to the Rubidium Frequency StandardI placed the SRS Rubidium FS275 over the PSL
rack, next to the frequency counter. This
one and the Marconi on the PSL rack have
  
  1145   Tue Nov 18 19:44:53 2008 AlbertoUpdateGeneralX Arm Cavity "Negative" FSRs MeasuredPrevious measurements on the X arm cavity
revealed a shift of the frequencies of the
cavity resonances from where one would expect
 2008-11-17_Linear_Fit.pdf 
  1144   Tue Nov 18 19:37:23 2008 YoichiUpdateIOOMC1 OSEM signals sign flipped and c1susvme1 restart problemAround 2PM, MC1 started to swing crazily.

The damping feedback was not working and
  
  1143   Tue Nov 18 13:28:08 2008 CarynDAQIOOnew channel for MC drum modesAlberto has added a channel for the Mode Cleaner
drum modes.
C1:IOO-MC_DRUM1
  
  1142   Mon Nov 17 20:47:19 2008 CarynSummaryGeneralDrove MC at 28kHz to excite drum modesRana, Alberto and I observed drum mode frequencies
at 23.221kHz(MC1), 28.039kHz(MC2), 28.222kHz(MC3)
while driving the mode cleaner. We observed
  
  1141   Mon Nov 17 16:59:22 2008 JenneUpdatePEMSeismometer hooked up, reading channels on DataViewerAlberto, Jenne

The Guralp Seismometer is (finally) hooked
  
  1140   Mon Nov 17 15:07:06 2008 YoichiUpdatePSLReference cavity ring downI used MATLAB's system identification tool
box to estimate the response of the reference
cavity, i.e. cavity pole.
 Fit.png 
  1139   Mon Nov 17 11:01:15 2008 AlbertoHowToElectronicsCalibrating the Frequency Standard of the MarconiI locked the [COLOR=purple][I]SRS Rubidium
Frequency Standard FS275[/I][/COLOR] to the
the 1pps from the GPS. The specs from the
 2023ASeriesOperatingManual.pdfSRS_FS275_Rubidium_Frequency_Standard.pdf 
  1138   Fri Nov 14 22:40:51 2008 YoichiUpdatePSLReference cavity ring down[quote]
To make the DEI pulser make a fast pulse
on the EO shutter EOMs, we had to make sure:
  
  1137   Fri Nov 14 20:35:47 2008 ranaUpdatePSLReference cavity ring downTo make the DEI pulser make a fast pulse on
the EO shutter EOMs, we had to make sure:
  
  1136   Fri Nov 14 19:20:42 2008 YoichiUpdatePSLReference cavity ring downThanks to Bob making the high-voltage BNC
cables for the HV pulse generator, I was
able to operate the EOM in front of
 RingDown.png 
  1135   Fri Nov 14 17:41:50 2008 JenneOmnistructureElectronicsSweet New Soldering IronThe fancy new Weller Soldering Iron is now
hooked up on the electronics bench.  
 newSolderingIron.JPG 
  1134   Fri Nov 14 11:33:19 2008 steveUpdateVACSRS-RGA installedOld Dycor rga is removed and new SRS-RGA200
installed.
It is pumped down and ready for hooking up
  
  1133   Thu Nov 13 15:50:44 2008 AlbertoConfigurationGeneralGPS 10MHz clockThe schematic of the 1Y7 rack that Alan pointed
out (see attachment) don't represent anymore
the actual rack.
 rackstuff.pdf 
  1132   Thu Nov 13 11:33:25 2008 AlbertoHowToTreasureMaking (good) Matlab figuresJust a little summary of some useful ways
to change plot settings in Matlab that I
wanted to share and remember for the future:
  
ELOG V3.1.3-