ID |
Date |
Author |
Type |
Category |
Subject |
12692
|
Fri Dec 30 10:27:46 2016 |
rana | Update | DetChar | summary pages dead again |
Dead again. No outputs for the past month. We really need a cron job to check this out rather than wait for someone to look at the web page. |
12693
|
Thu Jan 5 21:43:16 2017 |
rana | Update | DetChar | summary pages dead again |
Max tells us that soem conf files were bad and that he did something and now some pages are being made. But the PEM and MEDM pages are bank. Also the ASC tab looks bogus to me. |
12915
|
Wed Mar 29 09:24:28 2017 |
Steve | Update | lore | summery pages |
The summery pages are working at a slow motion speed. It's response time 12 minutes. |
13049
|
Wed Jun 7 14:27:23 2017 |
Steve | Update | Summary Pages | summery pages not working |
Last good page May 18, 2017
Not found, error message May 19 - June 4,2017
Blank plots, June 5, 2017 |
4847
|
Tue Jun 21 16:11:13 2011 |
steve | Update | SAFETY | surf safety training |
40m surfs: Nicole Ing, Iswita Saikia and Sonali Mohapatra received 40m specific safety training today. |
8743
|
Tue Jun 25 10:23:20 2013 |
Steve | Update | safety | surf safety training |
Alex Cole and Craig Cahillane received 40m specific, basic safety training last week.
|
10069
|
Thu Jun 19 10:39:22 2014 |
steve | Update | safety | surf safety training |
Andres Medina and Andrew "Harry" Hall received 40m specific safety training. They did general safety already and their laser safety training will be this after noon. |
13843
|
Tue May 15 13:34:30 2018 |
Steve | Update | safety | surf safety training |
Pooja and Keirthana received 40m specific basic safety training. |
14031
|
Thu Jun 28 13:12:20 2018 |
Steve | Update | safety | surf safety training |
Shruti and Sandrine received 40m specific basic safety training this morning.
Quote: |
Pooja and Keirthana received 40m specific basic safety training.
|
|
1700
|
Wed Jun 24 17:08:16 2009 |
steve | Bureaucracy | SAFETY | surf student safety |
The 40m lab specific safety training is done. The participants were
Stephanie Erickson, Clara Bennett, Chris Zimmerman, Zach Commings, Michelle Stephen surfs and Drew Cappel postock.
They have already went through the Caltech Safety Office laser and general safety training.
They still have to read, understand and sign the the SOP for the laser & lab |
5116
|
Thu Aug 4 08:25:51 2011 |
steve | Update | SUS | sus at atm |
ITMX and PRM moved alot. BS and ITMY just a little based on oplev reference. |
5118
|
Thu Aug 4 11:18:12 2011 |
rana | Update | SUS | sus at atm |
Remember that the Oplevs are not good references because of the temperature sensitivity. The week long trend shows lots of 24 hour fluctuations. |
5138
|
Mon Aug 8 12:08:05 2011 |
rana | Update | SUS | sus at atm |

A plot showing that the daily variation in the OLs is sometimes almost as much as the full scale readout (-1 to +1). |
833
|
Thu Aug 14 10:26:45 2008 |
steve | HowTo | SUS | sus cable pin cheater for out of vac damping |
The 40m D25 vacuum feed troughs give you a mirror image pin count.
Sus damping outside of the vacuum envelope require this cheater cable where
on the male D pin 1 is connected to female D 13 and so on
and male D pin 14 is connected to female D 25 and so on |
6278
|
Tue Feb 14 08:22:27 2012 |
steve | Update | SUS | sus damping restored |
ITMX, PRM and BS watchdogs are tripped. They were restored.
Stable MC was disabled so I can use MC_REFL 1 W beam to measure green glass . |
2773
|
Mon Apr 5 14:10:06 2010 |
steve | Update | SUS | sus damping restored |
Quote: |
This morning, at about 12 Koji found all the front-ends down.
At 1:45pm rebooted ISCEX, ISCEY, SOSVME, SUSVME1, SUSVME2, LSC, ASC, ISCAUX
Then I burtestored ISCEX, ISCEY, ISCAUX to April 2nd, 23:07.
The front-ends are now up and running again.
|
I restored damping to all SUSes except ITM-east. The ITMX OSEMs are being used in the clean assembly room. |
12917
|
Wed Mar 29 16:38:00 2017 |
Steve | Omnistructure | Treasure | sus fiber illluminated |
|
12919
|
Thu Mar 30 10:41:56 2017 |
rana | Omnistructure | Treasure | sus fiber illluminated |
Very, very cool!  |
6312
|
Fri Feb 24 08:06:52 2012 |
steve | Update | SUS | sus restored |
Quote: |
The following optics were kicked:
MC1 MC2 MC3 ETMX ETMY ITMX ITMY PRM SRM BS
Fri Feb 24 04:11:15 PST 2012
1014120690
Steve (or anyone), can you restore the watchdogs when you come to the lab in the morning ?
|
Kiwamu (or whoever is here last tonight): please run the free-swing/kick script (/opt/rtcds/caltech/c1/scripts/SUS/freeswing) before you leave, and I'll check the matrices and update the suspensions tomorrow morning.
|
|
All suspentions were restored and MC locked. PRM side osem RMS motion was high.
Atm2, Why the PRM is 2x as noisy as the SRM ? |
5011
|
Thu Jul 21 10:08:30 2011 |
steve | Update | SUS | sus sensor summary |
OSEM voltages to be corrected at upcoming vent: threshold ~ 0.7-1.2V, ( at 22 out of 50 )
ITMX_UL, UR, LL, LR, SD
ITMY_UL
ETMX_UL, UR, LL, LR, SD
ETMY_UL
SRM_UL, UR, LL
MC2_UR_SD
BS_UR, SD
MC3_UL, LR, LL
|
6578
|
Fri Apr 27 09:00:15 2012 |
Jamie | Update | CDS | sus watchdogs? |
Why are all the suspension watchdogs tripped? None of the suspension models are running on c1ioo, so they should be completely unaffected. Steve, did you find them tripped, or did you shut them off?
In either event they should be safetly turned back on. |
6579
|
Fri Apr 27 09:27:48 2012 |
Den | Update | CDS | sus watchdogs? |
Quote: |
Why are all the suspension watchdogs tripped? None of the suspension models are running on c1ioo, so they should be completely unaffected. Steve, did you find them tripped, or did you shut them off?
In either event they should be safetly turned back on.
|
I've turned off the coils. Though non of them are on the c1ioo, who knows what can happen when we'll try to run the models again. |
14589
|
Thu May 2 15:15:15 2019 |
Jon | Omnistructure | Computers | susaux machine renamed |
Now that the replacement susaux machine is installed and fully tested, I renamed it from c1susaux2 to c1susaux and updated the DNS lookup tables on chiara accordingly. |
5580
|
Fri Sep 30 03:14:18 2011 |
kiwamu | Update | CDS | suspension became crazy : c1sus rebooted |
Quote from #5579 |
Then we restarted daqd.
|
[Suresh / Kiwamu]
The c1lsc and c1sus machine were rebooted.
- - (CDS troubles)
After we restarted daqd and pressed some DAQ RELOAD buttons the c1lsc machine crashed.
The machine didn't respond to ssh, so the machine was physically rebooted by pressing the reset button.
Then we found all the realtime processes on the c1sus machine became frozen, so we restarted them by sshing and typing the start scripts.
However after that, the vertex suspensions became undamped, even though we did the burt restore correctly.
This symptom was exactly the same as Jenne reported (#5571).
We tried the same technique as Jenne did ; hardware reboot of the c1sus machine. Then everything became okay.
The burt restore was done for c1lsc, c1asc, c1sus and c1mcs.
- - (ITMX trouble)
During the trial of damping recovery, the ITMX mirror seemed stacked to an OSEM. The UL readout became zero and the rest of them became full range.
Eventually introducing a small offset in C1:SUS-ITMX_YAW_COMM released the mirror. The amount of the offset we introduced was about +1. |
8159
|
Mon Feb 25 20:04:22 2013 |
Jamie | Update | SUS | suspension controller model modifications in prep for global damping initiative |
[Jamie, Brett, Jenne]
We made some small modifications to the sus_single_control suspension controller library part to get in/out the signals that Brett needs for his "global damping" work. We brought out the POS signal before the SUSPOS DOF filter, and we added a new GLOBPOS input to accommodate the global damping control signals. We added a new EPIC input to control a switch between local and global damping. It's all best seen from this detail from the model:

The POSOUT goto goes to an additional output. As you can see I did a bunch of cleanup to the spaghetti in this part of the model as well.
As the part has a new input and output now we had to modify c1sus, c1scx, c1scy, and c1mcs models as well. I did a bunch of cleanup in those models as well. The models have all been compiled and installed, but a restart is still needed. I'll do this first thing tomorrow morning.
All changes were committed to the userapps SVN, like they should always be. 
We still need to update the SUS MEDM screens to display these new signals, and add switches for the local/global switch. I'll do this tomorrow.
During the cleanup I found multiple broken links to the sus_single_control library part. This is not good. I assume that most of them were accidental, but we need to be careful when modifying things. If we break those links we could think we're updating controller models when in fact we're not.
The one exception I found was that the MC2 controller link was clearly broken on purpose, as the MC2 controller has additional stuff added to it ("STATE_ESTIMATE"):

I can find no elog that mentions the words "STATE" and "ESTIMATE". This is obviously very problematic. I'm assuming Den made these modifications, and I found this report: 7497, which mentions something about "state estimation" and MC2. I can't find any other record of these changes, or that the MC2 controller was broken from the library. This is complete mickey mouse bullshit. Shame shame shame. Don't ever make changes like this and not log it.
I'm going to let this sit for a day, but tomorrow I'm going to remove replace the MC2 controller with a proper link to the sus_single_control library part. This work was never logged so it didn't happen as far as I'm concerned.
|
5263
|
Thu Aug 18 12:22:37 2011 |
jamie | Update | SUS | suspension update |
Most of the suspension look ok, with "badness" levels between 4 and 5. I'm just posting the ones that look slightly less ideal below.
- PRM, SRM, and BS in particular show a lot of little peaks that look like some sort of intermodulations.
- ITMY has a lot of elements with imaginary components
- The ETMY POS and SIDE modes are *very* close together, which is severely adversely affecting the diagonalization
|
7478
|
Thu Oct 4 14:08:49 2012 |
jamie | Update | SUS | suspensions damped |
All suspension damping has been restored. |
2031
|
Thu Oct 1 08:37:43 2009 |
steve | Update | SUS | suspention damping restored and MZ HV stuck |
Earthquake of magnitude 5.0 shakes ETMY loose.
MC2 lost it's damping later. |
654
|
Thu Jul 10 13:47:12 2008 |
Yoichi | HowTo | Computers | svn access via https |
Now you can access to the svn repository on nodus by https.
To perform a checkout, you can use the following command
svn co --username svn40m https://nodus.ligo.caltech.edu:30889/svn/trunk/chans
This will check out "chans" directory.
The password for svn40m is written in the usual place.
You can also access the URL by a web browser to see the repository in a very primitive way.
A nice web interface for browsing the repository is planed but not yet implemented. |
7296
|
Tue Aug 28 17:02:16 2012 |
jamie | Update | General | svn commit changes |
I just spent the last hour checking in a bunch of uncommitted changes to stuff in the SVN. We need to be MUCH BETTER about this. We must commit changes after we make them. When multiple changes get mixed together there's no way to recover from one bad one. |
969
|
Fri Sep 19 00:18:14 2008 |
rana | Update | Computers | svn is old |
linux2:mDV>ssh nodus
Password:
Last login: Fri Sep 19 00:11:44 2008 from gwave-69.ligo.c
Sun Microsystems Inc. SunOS 5.9 Generic May 2002
nodus:~>c
nodus:caltech>cd apps/
nodus:apps>cd mDV
nodus:mDV>svn update
svn: This client is too old to work with working copy '.'; please get a newer Subversion client
nodus:mDV>whoami
controls
nodus:mDV>uname -a
SunOS nodus 5.9 Generic_118558-39 sun4u sparc SUNW,A70 Solaris
nodus:mDV>pwd
/cvs/cds/caltech/apps/mDV
nodus:mDV>  |
972
|
Fri Sep 19 09:49:42 2008 |
Yoichi | Update | Computers | svn is old |
The problem below is fixed now.
The cause was .svn/entries and .svn/format had wrong version number "9" where it had to be "8".
I changed those files in all the sub-directories. Now svn up runs fine.
I don't know how this version discrepancy happened.
Quote: | linux2:mDV>ssh nodus
Password:
Last login: Fri Sep 19 00:11:44 2008 from gwave-69.ligo.c
Sun Microsystems Inc. SunOS 5.9 Generic May 2002
nodus:~>c
nodus:caltech>cd apps/
nodus:apps>cd mDV
nodus:mDV>svn update
svn: This client is too old to work with working copy '.'; please get a newer Subversion client
nodus:mDV>whoami
controls
nodus:mDV>uname -a
SunOS nodus 5.9 Generic_118558-39 sun4u sparc SUNW,A70 Solaris
nodus:mDV>pwd
/cvs/cds/caltech/apps/mDV
nodus:mDV>  |
|
508
|
Fri May 30 21:30:15 2008 |
tobin | Configuration | Computers | svn on solaris |
I installed svn on op440m. This involved installing the following packages from sunfreeware:
apache-2.2.6-sol9-sparc-local libiconv-1.11-sol9-sparc-local subversion-1.4.5-sol9-sparc-local
db-4.2.52.NC-sol9-sparc-local libxml2-2.6.31-sol9-sparc-local swig-1.3.29-sol9-sparc-local
expat-2.0.1-sol9-sparc-local neon-0.25.5-sol9-sparc-local zlib-1.2.3-sol9-sparc-local
gdbm-1.8.3-sol9-sparc-local openssl-0.9.8g-sol9-sparc-local
The packages are located in /cvs/cds/caltech/apps/solaris/packages. The command line to install
a package is "pkgadd -d " followed by the package name. This can be repeated on nodus to get
svn over there. (Kind of egregious to require an apache installation for the svn _client_, I
know.) |
2891
|
Thu May 6 19:23:54 2010 |
Frank | Summary | Computers | svn problems |
i tried to commit something this afternoon and got the following error message:
Command: Commit
Adding: C:\Caltech\Documents\40m-svn\nodus\frank
Error: Commit failed (details follow):
Error: Server sent unexpected return value (405 Method Not Allowed) in response to
Error: MKCOL request for '/svn/!svn/wrk/d2523f8e-eda2-d847-b8e5-59c020170cec/trunk/frank'
Finished!:
anyone had this before? what's wrong? |
9182
|
Tue Oct 1 14:12:22 2013 |
rana | Summary | CDS | svndumpfilter on linux1 makes NFS slow |
Yesterday and this morning's slow NFS disk access was caused by 'svndumpfilter' being run at linux1 to carve out the Noise Budget directory. It is being moved to another server; I think the disk access is back to normal speed now. |
3988
|
Mon Nov 29 11:51:41 2010 |
kiwamu | Update | IOO | swaped in-vac PZT mirrors |
This morning I opened the chambers and started some in-vac works.
As explained in this entry, I swapped pzt mirror (A) and (C) successfully.
The chambers are still open, so don't be surprised.
(today's missions for IOO)
- cabling for the pzt mirrors
- energizing the pzt mirrors and slide them to their midpoint.
- locking and alignment of the MC
- realignment of the pzt mirrors and other optics.
- letting the beam go down to the arm cavity
|
3992
|
Tue Nov 30 04:22:52 2010 |
kiwamu | Update | IOO | swaped in-vac PZT mirrors |
As a result of the vacuum work, now the IR beam is hitting ETMX.
The spot of the transmitted beam from the cavity can be found at the end table by using an IR viewer.
Quote: #3988 |
(today's missions for IOO)
- cabling for the pzt mirrors
- energizing the pzt mirrors and slide them to their midpoint.
- locking and alignment of the MC
- realignment of the pzt mirrors and other optics.
- letting the beam go down to the arm cavity
|
|
10627
|
Tue Oct 21 00:38:40 2014 |
ericq | Update | LSC | sweep + RMS as uncertainty |
Quote: |
BUT, what we really need (instead of just the DC sweeps) is the DC sweep with the uncertainty/noise displayed as a shaded area on the plot, as Nic did for us in the pre-CESAR modelling.
|
I've taken a first stab at this. Through various means, I've made an estimation of the total noise RMS of each error signal, and plotted a shaded region that shows the range of values the error signal is likely to take, when the IFO is statically sitting at one CARM offset.
I have not included any effects that would change the RMS of these signals in a CARM-offset dependent way. Since this is just a rough first pass, I didn't want to get carried away just yet.
For the transmission PDs, I measured the RMS on single arm lock. I also measured the incident power on the QPDs and thorlabs PDs for an estimate of shot noise, but this was ridiculously smaller than the in-loop RIN. I had originally though of just plotting sensing noise for the traces (i.e. dark+shot), because the amount of seismic and frequency noise in the in-loop signal obviously depends on the loop, but this gives a very misleading, tiny value. In reality we have RIN from the PRC due to seismic noise, angular motion of the optics, etc., which I have not quantified at this time.
So: for this first, rough, pass, I am simply multiplying the single transmission noise RMSs by a factor of 10 for the coupled RMS. If nothing else, this makes the SqrtInv signal look plausible when we actually practically find it to be plausible.
For the REFL PDs, I misaligned the ITMs for a prompt PRM reflection for a worst-case shot noise situation, and took the RMS of the spectra. (Also wrote down the dark RMSs, which are about a factor of 2 lower). I then also multiplied these by ten, to be consistent with the transmission PDs. In reality, the shot noise component will go down as we approach zero CARM offset, but if other effects dominate, that won't matter.
Enough blathering, here's the plot:

Now, in addition to the region of linearity/validity of the different signals, we can hopefully see the amount of error relative to the desired CARM offset. (Or, at least, how that error qualitatively changes over the range of offsets)
This suggests that we MAY be able to hop over to a normalized RF signal; but this is a pretty big maybe. This signal has the response of the quotient of two nontrivial optical plants, which I have not yet given much thought to; it is probably the right time to do so... |
10631
|
Wed Oct 22 06:32:29 2014 |
rana | Update | LSC | sweep + RMS as uncertainty |
This is looking very useful. It will be useful if you can upload some python code somewhere so that I can muck with it.
I would guess that the right way to determine the trans RMS is just to use the single arm lock RIN and then apply that as RIN (not pure TR RMS) to the TR signals before doing the sqrt operation. |
16287
|
Mon Aug 23 10:17:21 2021 |
Paco | Summary | Computers | system reboot glitch |
[paco]
At 09:34 PST I noted a glitch in the controls room as the machines went down except for c1ioo. Briefly, the video feeds disappeared from the screens, though the screens themselves didn't lose power. At first I though this was some kind of power glitch, but upon checking with Jordan, it most likely was related to some system crash. Coming back to the controls room, I could see the MC reflection beam swinging, but unfortunately all the FE models came down. I noticed that the DAQ status channels were blank.
I ssh into c1ioo no problem and ran "rtcds stop c1ioo c1als c1omc", then "rtcds restart c1x03" to do a soft restart. This worked, but the DAQ status was still blank. I then tried to ssh into c1sus and c1lsc without success, similarly c1iscex and c1iscey were unreachable. I went and did a hard restart on c1iscex by switching it off, then its extension chassis, then unplugging the power cords, then inverting these steps, and could ssh into it from rossa. I ran "rtcds start c1x01" and saw the same blank DAQ status. I noticed the elog was also down... so nodus was also affected?
[paco, anchal]
Anchal got on zoom to offer some assistance. We discovered that the fb1 and nodus were subject to some kind of system reboot at precisely 09:34. The "systemctl --failed" command on fb1 displayed both the daqd_dc.service and rc-local.service as loaded but failed (inactive). Is it a good idea to try and reboot the fb1 machine? ... Anchal was able to bring elog back up from nodus (ergo, this post).
[paco]
Although it probably needs the DAQ service from the fb1 machine to be up and running, I tried running the scripts/cds/rebootC1LSC.sh script. This didn't work. I tried running sudo systemctl restart daqd_dc from the fb1 machine without success. Running systemctl reset-failed "worked" for daqd_dc and rc-local services on fb1 in the sense that they were no longer output from systemctl --failed, but they remained inactive (dead) when running systemctl status on them. Following from 15303 I succeeded in restarting the daqd services. Turned out I needed to manually start the open-mx and mx services in fb1. I rerun the restartC1LSC script without success. The script fails because some machines need to be rebooted by hand.
|
8285
|
Wed Mar 13 11:34:24 2013 |
Steve | Update | optical tables | table covers moved to CES |
The two acrylic optical table enclosures were moved from the carpenter shop to CES. I need to order windows. The latest quotes from Laseroptik are posted at the wiki / aux_optics page.
Things to do: order windows, draw and order window flange, install surgical tubing seals, buy and line enclosures with IR shield films. |
2601
|
Fri Feb 12 18:58:46 2010 |
kiwamu | Update | Green Locking | take some optics away from the ETM end table |
In the last two days Steve and I took some optics away from the both ETM end table.
This is because we need an enough space to set up the green locking stuff into the end table, and also need to know how much space is available.
Optics we took away are : Alberto's RF stuff, fiber stuff and some optics obviously not in used.
The picture taken after the removing is attached. Attachment1:ETMX, Attachment2:ETMY
And the pictures taken before the removing are on the wiki, so you can check how they are changed.
http://lhocds.ligo-wa.caltech.edu:8000/40m/Optical_Tables |
2604
|
Tue Feb 16 09:51:22 2010 |
Alberto | Update | Green Locking | take some optics away from the ETM end table |
Quote: |
In the last two days Steve and I took some optics away from the both ETM end table.
This is because we need an enough space to set up the green locking stuff into the end table, and also need to know how much space is available.
Optics we took away are : Alberto's RF stuff, fiber stuff and some optics obviously not in used.
The picture taken after the removing is attached. Attachment1:ETMX, Attachment2:ETMY
And the pictures taken before the removing are on the wiki, so you can check how they are changed.
http://lhocds.ligo-wa.caltech.edu:8000/40m/Optical_Tables
|
The PD Kiwamu removed from the Y table was TRY, which we still need.
My bad if he took that. By mistake I told him that was the one I installed on the table for the length measurement and we didn't need it anymore.
I'm going to ask Kiwamu if he can kindly put it back. |
5691
|
Wed Oct 19 05:15:44 2011 |
kiwamu | Update | SUS | taking care of SRM |
I made some efforts to fix the situation of SRM but it is still bad.
The POS motion wasn't well damped. Something is wrong either (maybe both) sensing part or actuation part.
I am going to check the sensing matrix with the new free swinging spectra (#5690)
(Symptom)
When I was trying to lock SRMI I found that the fringes observed at the AS camera didn't show spatial higher order modes, which is good.
So I thought the SRM suspension became quiet, but it actually wasn't. Because the RMS monitor of the SRM OSEMs already went to about 30 counts.
At the same time the opelev error signals were well suppressed. It means some DOFs which were insensitive to the oplev were ringing up, namely POS and SIDE.
According to the LSC error signal and the ASDC signal, I believe that the POS was going wild (although I didn't check the OSEM spectra).
(Some efforts)
+ Readjusted the f2a filters (see the attachment).
+ Tried to eliminate a coupling between the POS and SIDE drives by tweaking the output matrix.
=> In order to eliminate the coupling from the POS drive to SIDE sensor, I had to put a comparable factor into an element.
So it might be possible that the POS sensor was showing the SIDE signal and vice versa.
In order to check it I left SRM free swinging (#5690).
Quote from #5684 |
The main reason why I couldn't lock DRMI was that the suspensions were touchy and especially the SRM suspension wasn't good.
|
|
5699
|
Wed Oct 19 15:46:49 2011 |
kiwamu | Update | SUS | taking care of SRM |
Quote from #5691 |
I am going to check the sensing matrix with the new free swinging spectra (#5690)
|
The SRM input matrix has been readjusted.
However still there is the unwanted coupling from the POS drive to SIDE signal and from the SIDE drive to POS signal.
|
|
|
BADNESS |
SRM |
 |
pit yaw pos side butt
UL 0.871 0.975 1.115 -0.295 1.096
UR 1.015 -1.025 1.128 -0.140 -1.053
LR -0.985 -0.984 0.885 -0.088 0.831
LL -1.129 1.016 0.872 -0.243 -1.020
SD 0.084 0.061 3.534 1.000 -0.018
|
4.24965 |
|
7325
|
Fri Aug 31 07:32:49 2012 |
Steve | Update | SUS | target for BS |
Quote: |
We installed beam targets on PRM and BS suspension cages.
On both suspensions one of the screw holes for the target actually houses the set screw for the side OSEM. This means that the screw on one side of the target only goes in partial way.
The target installed on BS is wrong! It has a center hole, instead of two 45 deg holes. I forgot to remove it, but it will obvious it's wrong to the next person who tries to use it. I believe we're supposed to have a correct target for BS, Steve?
The earthquake stop screws on PRM were too short and were preventing installation of the PRM target. Therefore, in order to install the target on PRM I had to replace the earthquake stops with ones Jenne and I found in the bake lab clean room that were longer, but have little springs instead of viton inserts at the ends. This is ok for now, but
WE NEED TO REMEMBER TO REPLACE EARTHQUAKE STOPS ON PRM WHEN WE CLOSE UP.
We checked the beam through PRM and it's a little high to the right (as viewed from behind). Tomorrow we're going to open ITMX chamber so that we can get a closer look at the spot on PR2.
|
The two eye target for the BS is in the clean tool box. It actually has irises. |
7324
|
Thu Aug 30 20:35:09 2012 |
jamie | Update | SUS | target installed on PRM, temporary earthquake stops in place |
We installed beam targets on PRM and BS suspension cages.
On both suspensions one of the screw holes for the target actually houses the set screw for the side OSEM. This means that the screw on one side of the target only goes in partial way.
The target installed on BS is wrong! It has a center hole, instead of two 45 deg holes. I forgot to remove it, but it will obvious it's wrong to the next person who tries to use it. I believe we're supposed to have a correct target for BS, Steve?
The earthquake stop screws on PRM were too short and were preventing installation of the PRM target. Therefore, in order to install the target on PRM I had to replace the earthquake stops with ones Jenne and I found in the bake lab clean room that were longer, but have little springs instead of viton inserts at the ends. This is ok for now, but
WE NEED TO REMEMBER TO REPLACE EARTHQUAKE STOPS ON PRM WHEN WE CLOSE UP.
We checked the beam through PRM and it's a little high to the right (as viewed from behind). Tomorrow we're going to open ITMX chamber so that we can get a closer look at the spot on PR2. |
6803
|
Tue Jun 12 13:49:32 2012 |
Jamie | Configuration | Computer Scripts / Programs | tconvert |
A nicer, better maintained version of tconvert is now supplied by the lalapps package. It's called lalapps_tconvert . I installed lalapps on all the workstations and aliased tconvert to point to lalapps_tconvert. |
1655
|
Fri Jun 5 02:59:03 2009 |
pete, alberto | Update | Locking | tdsavg failure in cm_step script |
the command
tdsavg 5 C1:LSC-PD4_DC_IN1
was causing grievous woe in the cm_step script. It turned out to fail intermittently at the command line, as did other LSC channels. (But non-LSC channels seem to be OK.) So we power cycled c1lsc (we couldn't ssh).
Then we noticed that computers were out of sync again (several timing fields said 16383 in the C0DAQ_RFMNETWORK screen). We restarted c1iscey, c1iscex, c1lsc, c1susvme1, and c1susvme2. The timing fields went back to 0. But the tdsavg command still intermittently said "ERROR: LDAQ - SendRequest - bad NDS status: 13".
The channel C1:LSC-SRM_OUT16 seems to work with tdsavg every time.
Let us know if you know how to fix this.
|
1656
|
Fri Jun 5 13:51:49 2009 |
rob | Update | Locking | tdsavg failure in cm_step script |
Quote: |
the command
tdsavg 5 C1:LSC-PD4_DC_IN1
was causing grievous woe in the cm_step script. It turned out to fail intermittently at the command line, as did other LSC channels. (But non-LSC channels seem to be OK.) So we power cycled c1lsc (we couldn't ssh).
Then we noticed that computers were out of sync again (several timing fields said 16383 in the C0DAQ_RFMNETWORK screen). We restarted c1iscey, c1iscex, c1lsc, c1susvme1, and c1susvme2. The timing fields went back to 0. But the tdsavg command still intermittently said "ERROR: LDAQ - SendRequest - bad NDS status: 13".
The channel C1:LSC-SRM_OUT16 seems to work with tdsavg every time.
Let us know if you know how to fix this.
|
Did you try restarting the framebuilder?
What you type is in bold:
op440m> telnet fb40m 8087
daqd> shutdown
|