  2207   Mon Nov 9 08:43:16 2009 steveUpdateSUSMC2 damping restoredMC2 damping restored,  MZ locked and
the arms are flashing now.
  
  2234   Wed Nov 11 09:48:04 2009 steveUpdateIOOwhere is IOO-RFAMPD_DCMON ?RFAMPD_DCMON disappered on Nov 5, 2009  rfampddc.jpg 
  2248   Thu Nov 12 09:43:29 2009 steveUpdatePEMconstruction has started at CESThe concrete  floor cutting has begun
next door at CES
 cuttingconcr.jpgcutcon1.JPGcutcon2.JPG 
  2272   Mon Nov 16 09:37:41 2009 steveUpdatePEMconstruction is getting noisier 
ATM1: Seismometers are saturating,
suspensions are OK
 4hces.pngP1050734.JPGP1050736.JPG 
  2297   Thu Nov 19 09:25:19 2009 steveUpdateMOPAwater was added to the laser chillerI added ~500 cc of distilled water to the
laser chiller yesterday.
 htempwtr.png 
  2298   Thu Nov 19 09:48:54 2009 steveUpdatePEMconstruction effect8 days plot: Thurdsay, Friday, Sat and
Sun without construction
 varseism.png 
  2312   Mon Nov 23 10:11:03 2009 steveUpdatePEMlong term temp fluctuation of the 40m lab

    
        
 7ytemp.jpg 
  2313   Mon Nov 23 11:03:00 2009 steveUpdateSUSjackhammer special well under control


   
        
            
 dig10d.pngP1050740.JPG 
  2314   Mon Nov 23 16:28:12 2009 steveSummaryCamerasVideo swicher options


   
        
            
  
  2370   Wed Dec 9 09:07:32 2009 steveUpdatePEMhigh seismic activityThe construction activity is shaking the
tables in the control room.  The compactor-
large remote controlled jackhammer is in
 seis24d.pngseis4h.pngP1050833.JPGP1050836.JPG 
  2377   Thu Dec 10 08:43:25 2009 steveFrogsEnvironmentdiesel fumes are less


   
        
            
 P1050817.JPG 
  2388   Thu Dec 10 16:51:35 2009 steveUpdateVACpumpdown will start tomorrow morningThe vacuum system is at 760 torr 
All chambers with doors on and their annuloses
are pumped down.
  
  2394   Fri Dec 11 08:35:04 2009 steveConfigurationVACpumpdown has startedOplev positions before and after drag wiped
arm TMs as of yesterday. Slow-mode pumpdown
has started with 3/4 turn opened  RV1
 wiping.jpg 
  2400   Fri Dec 11 15:21:40 2009 steveConfigurationVACpumpdown#67 is completed

    
        
 pd7h.jpgoplevpd8h.jpg 
  2409   Mon Dec 14 11:21:23 2009 steveOmnistructureEnvironmentAnts in the coffee maker 
 We still had some ants visiting
the sink area this morning. These ants seem
  
  2439   Mon Dec 21 08:16:54 2009 steveMetaphysicsPEMjackhammering next doorAt ITMX, on the CES side, 5 Ft  from
the wall the jackhammer is on. The susses
are holding well.
  
  2443   Tue Dec 22 10:04:41 2009 steveOmnistructurePEMmiracle in the 40mWe have been waiting for this for 20 some
years. Arrowhead water with cooler. AWESOME
THANKS Alan
 h2oo.JPG 
  2466   Wed Dec 30 09:57:53 2009 steveUpdatePSLthirsty water chillerI added 600 cc of Arrowhead Distilled Water
to the chiller.
60 days plot shows that about every
 htemp60d.png 
  2482   Wed Jan 6 16:48:52 2010 steveBureaucracySAFETYcopied NPRO keyWe lost our key to the Lightwave 125/6-OPN-PS  
The key shop just made one look a like that
works.
 nprokey.JPG 
  2489   Fri Jan 8 18:20:12 2010 steveMetaphysicsTreasureRob now can concentrate on his thesisWe are celebrating Rob's promotion to thesis
poetry.  These pictures were taken on
December 9, 2009
 rob2.JPGrob3.JPGrob1.JPG 
  2507   Tue Jan 12 09:14:52 2010 steveSummaryGeneralScattering Measurements of 35W Beam Dumps 
 What was the power level, polarization
and beam size at beam trap?
  
  2511   Tue Jan 12 14:28:01 2010 steveSummaryEnvironmentlab temp of 7 years

    
        
 labtemp7y.png 
  2556   Mon Feb 1 18:33:10 2010 steveUpdateMOPAVe half the lazer!The 2W
NPRO from Valera arrived today and I haf
 inno2w.JPGinno2Wb.JPG 
  2561   Tue Feb 2 16:10:09 2010 steveUpdatePEMconstruction progress next doorCES construction is progressing. The 40m
suspensions are bearing well.
atm1, PEM  vs sus plots of 120
 pem120d.jpg02022010.JPG02022010b.JPG02022010c.JPGicewall.JPG 
  2565   Wed Feb 3 07:57:01 2010 steveUpdatePSLPMC transmission is lowThe low PMC transmission alarm was on this
morning. The PMC alignment needs a touch
up.
 pmct40d.jpg 
  2568   Wed Feb 3 11:13:15 2010 steveConfigurationGeneralplaned power outage for Sat. Feb 20The electrical shop has to connect the
new power transformer at CES. This means
we will have no AC power for ~8 hrs on Saturday,
  
  2573   Fri Feb 5 11:01:49 2010 steveConfigurationVACslow pumpdown valve I have installed a slow start throttle
valve in front of V3  This spring loaded
valve will cut down on the flow at high pressures.
 slow.JPG 
  2585   Wed Feb 10 16:27:47 2010 steveConfigurationGeneral IFO beam heightsIN
VACUUM beam heights are ALL 5.5" 
This is measured from the top of the
  
  2589   Thu Feb 11 15:53:59 2010 steveConfigurationVACPSL output shutter is closedJoe and Alex are working on the computers.
Our vacuum system is temporary "All
off" condition: meaning all valves are
  
  2592   Thu Feb 11 18:53:57 2010 steveConfigurationVACVAC NORMAL is back

    
        
  
  2612   Thu Feb 18 10:10:43 2010 steveConfigurationGeneral480 V AC power turned offOnly the 40m cranes are running on 480VAC
The electricians are rewiring this transformer
on the mezzanine so it was shut down.
  
  2632   Tue Feb 23 14:56:24 2010 steveUpdateGeneralETMX optical table massOur janitor dropped one 48" long 
fluorescent tube on the top cover of ETMX-isct.
This accident made glasses fly all over the
 etmxmass.jpg 
  2633   Tue Feb 23 16:20:44 2010 steveConfigurationVACoutgassing + leak

    
        
 outgleak.jpg 
  2644   Fri Feb 26 15:32:13 2010 steveConfigurationVACpreparation for power outage: vacuum all offThere is a planned power outage tomorrow,
Saturday from 7am till midnight.
I vented all annulies and switched
 ventd3.jpg 
  2647   Mon Mar 1 08:49:37 2010 steveBureaucracySAFETYsafety auditThe 40m safety audit will be at Wednesday
afternoon, March 3
Please participate getting our lab
  
  2648   Mon Mar 1 11:21:50 2010 steveConfigurationVACvacuum contoller is back to normal


   
        
            
  
  2658   Fri Mar 5 11:21:18 2010 steveUpdateSUSused OSEMs are magnetic


   
        
            
  
  2663   Tue Mar 9 09:04:20 2010 steveUpdatePEMkeep vacuum chamber closedThey are sandblasting at CES: our particle
counts are very high. DO NOT OPEN CHAMBER!
 sandblasting.jpg 
  2667   Thu Mar 11 15:24:51 2010 steveMetaphysicsEnvironmentIFO was well protected

    
        
  
  2670   Fri Mar 12 17:08:22 2010 steveConfigurationVACbg-RGAscan at d18RGA scan of rga-region only at day 18  
This is the back ground of the rga with some
calibration gas.
 bg-d18_20100312scan.png 
  2673   Mon Mar 15 09:43:47 2010 steveUpdatePEMmore sandblasting todayDo not open IFO vacuum envelope today!
They are sandblasting again at CES
  
  2674   Mon Mar 15 16:39:36 2010 steveUpdatePEMGuralp2 centered

    
        
 grlp2ffst.jpg 
  2677   Tue Mar 16 09:37:30 2010 steveUpdateSUSeq 4.4 seen by oplevs and osemsThe oplev plots clearly show the alignment
effect of this eq.
 opleveq4.4.jpgeq4.4.jpgopleveq4.4d3.jpg 
  2678   Thu Mar 18 08:49:51 2010 steveUpdatePEMGuralp2 centered again ? 
Someone adjusted the Guralp2 mass
position last night??
 grlp2xadj.jpg 
  2694   Mon Mar 22 11:37:09 2010 steveUpdatePEMjackhammeringThere was more jackhammering this morning
just about 20 ft north-west of the beamsplitter
chamber, outside.
 jackhammering2.jpg 
  2699   Tue Mar 23 09:37:36 2010 steveUpdateIOOvac envelope has to be sealed as antproof for overnight


   
        
            
 pc3.JPGpc4.JPG 
  2701   Tue Mar 23 10:11:13 2010 steveUpdatePEM small air cond unit failed yesterdayOld control room air condition failed yesterday
around noon. It was blowing 80-85F hot air
for about 2-3 hours at racks 1Y4-7 and the
 20datm.jpg 
  2713   Thu Mar 25 09:07:08 2010 steveUpdatePEMGuralp2 x problem is back

    
        
 grlp2xproblm.jpg 
  2716   Fri Mar 26 10:48:35 2010 steveUpdateSAFETYsafety glasses measuredSafety
glasses 1064 nm transmission measured at
~200 mW level. They are all good.
 P1060188.JPGP1060199.JPG 
  2742   Wed Mar 31 15:31:53 2010 steveUpdatePSLReference Cavity RF PD base upgraded


   
        
            
 brspdbs.JPG 
ELOG V3.1.3-