40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 323 of 336  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  16240   Tue Jul 6 17:40:32 2021 KojiSummaryGeneralLab cleaningWe held the lab cleaning for the
first time since the campus reopening (Attachment
1).
 7x 
  16241   Thu Jul 8 11:20:38 2021 Anchal, Paco, GautamSummaryLSCPRFPMI locking attemptsLast night Gautam walked us through the
algorithm used to lock PRFPMI. We tried it
several times with the PSL HEPA filter off
  
  16242   Fri Jul 9 15:39:08 2021 AnchalSummaryALSSingle Arm Actuation Calibration with IR ALS Beat [Correction]I did this analysis again by just doing
demodulation go 5s time segments of the 60s
excitation signal. The major difference is
 ITMX_calibration_With_ALS_Beat.pdf 
  16243   Fri Jul 9 18:35:32 2021 YehonathanUpdateCDSOpto-isolator for c1auxeyFollowing Koji's channel list review,
we made changes to the
wiring spreadsheet.
  
  16244   Mon Jul 12 18:06:25 2021 YehonathanUpdateCDSOpto-isolator for c1auxeyI edited /cvs/cds/caltech/target/c1auxey1/ETMYaux.db
(after creating a backup) and added the spare
coil driver channels.
  
  16245   Wed Jul 14 16:19:44 2021 gautamUpdateGeneralBrrrSince the repair work, the temperature
is significantly cooler. Surprisingly, even
at the vertex (to be more specific, inside
 rmTemp.pdf 
  16246   Wed Jul 14 19:21:44 2021 KojiUpdateGeneralBrrrJordan reported on Jun 18, 2021:

"HVAC tech came today, and replaced
  
  16247   Wed Jul 14 20:42:04 2021 gautamUpdateLSCLocking[paco, gautam]

we decided to give the PRFPMI lock
a go early-ish. Summary of findings today
  
  16248   Thu Jul 15 14:25:48 2021 PacoUpdateLSCCM board[gautam, paco]

We tested the CM board by implementing
the high bandwidth IR lock (single arm).
 high_BW_TFs.pdf 
  16249   Fri Jul 16 16:26:50 2021 gautamUpdateComputersDocker installed on nodusI wanted to try hosting some docker images
on a "private" server, so I installed
Docker on nodus following the instructions
  
  16250   Sat Jul 17 00:52:33 2021 KojiUpdateGeneralCanon camera / small silver tripod / macro zoom lens / LED ring light borrowed -> QILCanon camera / small silver tripod / macro
zoom lens / LED ring light borrowed ->
QIL
 P_20210716_213850.jpg 
  16251   Mon Jul 19 22:16:08 2021 pacoUpdateLSCPRFPMI locking[gautam, paco]

Gautam managed to lock PRFPMI a
little before ~ 22:00 local time. The ALS
  
  16252   Wed Jul 21 14:50:23 2021 KojiUpdateSUSNew electronicsReceived:

Jun 29, 2021 BIO I/F 6 units
Jul 19, 2021 PZT Drivers x2 / QPD
 P_20210629_183950.jpegP_20210719_135938.jpeg 
  16253   Wed Jul 21 18:08:35 2021 yehonathanUpdateLoss MeasurementLoss measurement{Gautam, Yehonathan, Anchal, Paco}

We prepared for the loss measurement
using DC reflection method. We did the following
  
  16254   Thu Jul 22 16:06:10 2021 PacoUpdateLoss MeasurementLoss measurement[yehonathan, anchal, paco, gautam]

We concluded estimating the XARM
and YARM losses. The hardware configuration
  
  16255   Sun Jul 25 18:21:10 2021 KojiUpdateGeneralCanon camera / small silver tripod / macro zoom lens / LED ring light returned / Electronics borrowedCamera and accesories returned

One HAM-A coildriver and one sat
amp borrowed -> QIL
  
  16256   Sun Jul 25 20:41:47 2021 ranaUpdateLoss MeasurementLoss measurementWhat are the quantitative root causes for
why the statistical uncertainty is so large?
Its larger than 1/sqrt(N)
  
  16257   Mon Jul 26 17:34:23 2021 PacoUpdateLoss MeasurementLoss measurement[gautam, yehonathan, paco]

We went back to the loss data from
last week and more carefully estimated the
 LossMeasurement_RawData.pdfYARM_loss_stats.pdfXARM_loss_stats.pdf 
  16259   Tue Jul 27 17:14:18 2021 YehonathanUpdateBHDSOS assemblyJordan has made 1/4" tap holes in
the lower EQ stop holders (attachment). The
1/4" stops (schematics)
 20210727_154506.png 
  16260   Tue Jul 27 20:12:53 2021 KojiUpdateBHDSOS assembly1 or 2. The stained ones are just fine.
If you find the vented 1/4-20 screws in the
clean room, you can use them.
  
  16261   Tue Jul 27 23:04:37 2021 AnchalUpdateLSC40 meter party[ian, anchal, paco]

After our second attempt of locking
PRFPMI tonight, we tried to resotre XARM
 Screenshot_2021-07-27_22-19-58.png 
  16262   Wed Jul 28 12:00:35 2021 YehonathanUpdateBHDSOS assemblyAfter receiving two new tubes of EP-30
I resumed the gluing activities. I made a
spreadsheet
  
  16263   Wed Jul 28 12:47:52 2021 YehonathanUpdateCDSOpto-isolator for c1auxeyTo simulate a differential output I used
two power supplies connected in series. The
outer connectors were used as the outputs
 SUS-ETMY_SparePDMon0_NoRef.pngSUS-ETMY_SparePDMon0_Ref_WithGND.pngDifferentialOutputTest.png 
  16264   Wed Jul 28 17:10:24 2021 AnchalUpdateLSCSchnupp asymmetry[Anchal, Paco]

I redid the measurement of Schnupp
asymmetry today and found it to be 3.8 cm
 Lsch.pdf 
  16265   Wed Jul 28 20:20:09 2021 YehonathanUpdateGeneralThe temperature sensors and function generator have arrived in the labI put the temperature sensors box on Anchal's
table (attachment 1) and the function generator
on the table in front of the c1auxey Acromag
 20210728_201313.jpg20210728_201607.jpg 
  16266   Thu Jul 29 14:51:39 2021 PacoUpdateOptical LeversRecenter OpLevs[yehonathan, anchal, paco]

Yesterday around 9:30 pm, we centered
the BS, ITMY, ETMY, ITMX and ETMX oplevs
  
  16267   Mon Aug 2 16:18:23 2021 PacoUpdateASCAS WFS MICH commissioning[anchal, paco]

We picked up AS WFS comissioning
for daytime work as suggested by gautam.
  
  16268   Tue Aug 3 20:20:08 2021 AnchalUpdateOptical LeversRecentered ETMX, ITMX and ETMY oplevs at good stateLate elog. Original time 08/02/2021 21:00.

I locked both arms and ran ASS
to reach to optimum alignment. ETMY PIT >
  
  16269   Wed Aug 4 18:19:26 2021 pacoUpdateGeneralAdded infrasensing temperature unit to martian network[ian, anchal, paco]

We hooked up the infrasensing unit
to power and changed its default IP address
  
  16270   Thu Aug 5 14:59:31 2021 AnchalUpdateGeneralAdded temperature sensors at Yend and Vertex tooI've added the other two temperature
sensor modules on Y end (on 1Y4, IP: 192.168.113.241)
and in the vertex on (1X2, IP: 192.168.113.242).
  
  16271   Fri Aug 6 13:13:28 2021 AnchalUpdateBHDc1teststand subnetwork now accessible remotelyc1teststand subnetwork is now accessible
remotely. To log into this network, one needs
to do following:
  
  16272   Fri Aug 6 17:10:19 2021 PacoUpdateIMCMC rollercoaster[anchal, yehonatan, paco]

For whatever reason (i.e. we don't
really know) the MC unlocked into a weird
 MC2_trans_sum_2021-08-06_17-18-54.png 
  16273   Mon Aug 9 10:38:48 2021 AnchalUpdateBHDc1teststand subnetwork now accessible remotelyI had to add following two lines in the
/etc/network/interface file to make the special
ip routes persistent even after reboot:
  
  16274   Tue Aug 10 17:24:26 2021 pacoUpdateGeneralFive day trendAttachment 1 shows a five and a half day
minute-trend of the three temperature sensors.
Logging started last Thursday ~ 2 pm when
 six_day_minute_trend.png 
  16275   Wed Aug 11 11:35:36 2021 PacoUpdateLSCPRMI MICH orthogonality plan[yehonathan, paco]

Yesterday we discussed a bit about
working on the PRMI sensing matrix.
  
  16276   Wed Aug 11 12:06:40 2021 YehonathanUpdateCDSOpto-isolator for c1auxeyI redid the differential input experiment
using the DS360 function generator we recently
got. I generated a low frequency (0.1Hz)
 SUS-ETMY_SparePDMon0_2.png 
  16277   Thu Aug 12 11:04:27 2021 PacoUpdateGeneralPSL shutter was closed this morningThu Aug 12 11:04:42 2021 Arrived to find
the PSL shutter closed. Why? Who? When? How?
No elog, no fun. I opened it, IMC is now
  
  16278   Thu Aug 12 14:59:25 2021 KojiUpdateGeneralPSL shutter was closed this morningWhat I was afraid of was the vacuum interlock.
And indeed there was a pressure surge this
morning. Is this real? Why didn't we
 Screen_Shot_2021-08-12_at_14.58.59.png 
  16279   Thu Aug 12 20:52:04 2021 KojiUpdateGeneralPSL shutter was closed this morningI did a bit more investigation on this.

- I checked P1~P4, PTP2/3, N2,
TP2, TP3. But found only P1a and P2 were
 Screen_Shot_2021-08-12_at_20.51.19.pngScreen_Shot_2021-08-12_at_20.51.34.png 
  16280   Mon Aug 16 23:30:34 2021 PacoUpdateCDSAS WFS commissioning; restarting models[koji, ian, tega, paco]

With the remote/local assistance
of Tega/Ian last friday I made changes on
  
  16281   Tue Aug 17 04:30:35 2021 KojiUpdateSUSNew electronicsReceived:

Aug 17, 2021 2x ISC Whitening

Delivered 2x Sat Amp board to Todd
 P_20210816_234136.jpgP_20210816_235106.jpgP_20210816_234220.jpg 
  16282   Wed Aug 18 20:30:12 2021 AnchalUpdateASSFixed runASS scriptsLate elog:
Original time of work Tue Aug 17 20:30 2021


I locked the arms yesterday
  
  16283   Thu Aug 19 03:23:00 2021 AnchalUpdateCDSTime synchornization not runningI tried to read a bit and understand the
NTP synchronization implementation in FE
computers. I'm quite sure that NTP synchronization
  
  16284   Thu Aug 19 14:14:49 2021 KojiUpdateCDSTime synchornization not running131.215.239.14 looks like Caltech's
NTP server (ntp-02.caltech.edu)
https://webmagellan.com/explore/caltech.edu/28415b58-837f-4b46-a134-54f4b81bee53
  
  16285   Fri Aug 20 00:28:55 2021 AnchalUpdateCDSTime synchornization not runningI added ntpserver as a known host name
for address 192.168.113.201 (fb1's address
where ntp server is running) in the martian
  
  16286   Fri Aug 20 06:24:18 2021 AnchalUpdateCDSTime synchornization not runningI read on some stack exchange that 'NTP
synchornized' indicator turns 'yes'
in the output of command timedatectl only
  
  16287   Mon Aug 23 10:17:21 2021 PacoSummaryComputerssystem reboot glitch[paco]

At 09:34 PST I noted a glitch in
the controls room as the machines went down
  
  16288   Mon Aug 23 11:51:26 2021 KojiUpdateGeneralCampus Wide Power Glitch Reported: Monday, 8/23/21 at 9:30am Campus
Wide Power Glitch Reported:
Monday, 8/23/21 at 9:30am (more like 9:34am
  
  16289   Mon Aug 23 15:25:59 2021 Ian MacMillanUpdateCDSSUS simPlant modelI am adding a State-space block to the
SimPlant cds model using the example Chris
gave. I made a new folder in controls
 SimPlantStateSpace.zip 
  16290   Mon Aug 23 19:00:05 2021 KojiUpdateGeneralCampus Wide Power Glitch Reported: Monday, 8/23/21 at 9:30am Restarting the RTS was unsuccessful because
of the timing discrepancy error between the
RT machines and the FB. This time no matter
  
ELOG V3.1.3-