  679   Wed Jul 16 11:00:15 2008 MashaUpdateAuxiliary lockingimproving ADC input for the mach zehnder setup and completely unrelated happeningsFor most of last week, the SURFs + Jenne were
helping Mike and Ken with "stray light control
for
  
  678   Wed Jul 16 10:50:55 2008 EricSummaryCamerasWeekly SummaryFinished unwrapping, cleaning, baking, wrapping,
wrapping again, packing, and shipping the
baffles.  
 AttemptedPeakFit3.tiff 
  677   Wed Jul 16 09:27:17 2008 steveUpdateALARMPSL-FSS_RMTEMP alarm is falseMorning alarm sound is good for people who
does not drink coffee.
Our 40m alarm is on every morning.
 frmtemp2y.jpg 
  676   Tue Jul 15 19:15:57 2008 ranaSummarySUSETMX Dewhitening characterizationSince the boys found that the ETM dewhitening
transient was kicking the IFO out of lock
we
 etmx-dw-transient.pdf 
  675   Tue Jul 15 12:44:08 2008 JohnSummaryLockingDRFPMI with DC readoutRob, John

Last night, despite suspect alignment, we
  
  674   Tue Jul 15 12:23:22 2008 JenneUpdateGeneralMC2 Watchdog trippedAlberto, Jenne

Mode Cleaner was unlocked.  We checked, and
  
  673   Tue Jul 15 11:47:56 2008 JenneDAQPEMAccelerometer channels in ASS Adapt MEDM screenJenne, Sharon

We have traced which accelerometers correspond
  
  672   Tue Jul 15 10:24:57 2008 steveUpdatePSLPMC temp & pzt voltageThe PMC pzt HV was happy with no HEPA temp
stability.
Can we thermally insulate the pmc ?
 pmctemp.jpg 
  671   Tue Jul 15 10:09:42 2008 EricDAQCamerasDid anyone kill the picture taking process on Mafalda?Did anyone kill the process on Mafalda that
was taking pictures of the end mirror of
the x-arm last Friday?  I need to know whether
  
  670   Tue Jul 15 09:47:09 2008 steveUpdatePEMlab temps and particlesAll air condtion units were serviced last
Friday.
AC filters are trying to control our particle
 temps24d.jpg 
  669   Mon Jul 14 21:34:10 2008 AlbertoUpdateGeneralabs cavity length measurement experiment[quote]Lately I've been dealing with the alignment
of the interferometer to have a good beam
spot at the AS port. Today the alignment
  
  668   Mon Jul 14 19:15:43 2008 AlbertoUpdateGeneralabs cavity length measurement experimentLately I've been dealing with the alignment
of the interferometer to have a good beam
spot at the AS port. Today the alignment
  
  667   Mon Jul 14 12:43:07 2008 JohnSummaryComputersRestarted fb40m, tpman and c1ass    
  666   Mon Jul 14 10:57:00 2008 KojiFrogsEnvironmentSomeone at 40M sent LHO water of lifeSomeone at the 40m sent Mike@LHO a pound of
peets coffee with the name of Koji Arai.
It was a good surprise! Thanks, we will enjoy
  
  665   Mon Jul 14 00:36:19 2008 JohnSummaryPSLSlow sweep of laser temp - PMC PZT responseJohn, Rana

Follow up to # 663
 SlowTsweep.png 
  664   Sun Jul 13 22:39:16 2008 JohnSummaryGeneralEdited medm screens I've edited the FSS and PMC screens so that
red boxes are shown around the appropriate
slider if a gain or offset is not within
  
  663   Sun Jul 13 17:19:29 2008 ranaSummaryPSLMOPA SLOWM CalibrationJohn, Rana

We first unlocked the FSS and ramped the
 SLOWDCcalibration.png 
  662   Sat Jul 12 23:28:31 2008 ranaUpdatePSLPMC needs helpAs everyone has noticed recently, the PMC
seems to have a PZT problem. It often zooms
 Untitled.png 
  661   Fri Jul 11 23:55:25 2008 alanUpdateLockingRF common mode at zero offset[quote][I]rob, john, yoichi[/I]

[SIZE=3][FONT=Comic Sans MS]Last night we
  
  660   Fri Jul 11 20:16:01 2008 EricDAQCamerasTaking data from the GC 750 CameraMafalda has been set up with a background
process to constantly take data from the
GC 750 camera (at the end of the x-arm) for
  
  659   Fri Jul 11 09:29:02 2008 steveUpdatePSLthe PMC still hangs upMorning alarms:

PMC high voltage is railing, it's auto locker
 pmc4d.jpg 
  658   Fri Jul 11 00:30:24 2008 robMetaphysicsComputersstrange SUS controllers
[I]rob, johnnie[B]M[/B][/I]
  
  657   Thu Jul 10 23:27:57 2008 JohnMetaphysicsCamerasSecret handshakesRob and I have joined the ranks of the illuminati
and exercised our power.
  
  656   Thu Jul 10 19:12:07 2008 AlbertoUpdateGeneralabs cavity length measurement experimentYesterday morning, when I started, I found
the IFO beam on a different position and
the beam spot at the AS port looked very
  
  655   Thu Jul 10 14:59:01 2008 robUpdateLockingRF common mode at zero offset[I]rob, john, yoichi[/I]

[SIZE=3][FONT=Comic Sans MS]Last night we
 lock_control_sequence_worked.pngtrendpowerbuild.png 
  654   Thu Jul 10 13:47:12 2008 YoichiHowToComputerssvn access via httpsNow you can access to the svn repository on
nodus by https.
To perform a checkout, you can use the following
  
  653   Wed Jul 9 17:58:19 2008 JohnSummaryGeneralIlluminator alarmsThis morning some time was wasted on alignment
due to the illuminators.
  
  652   Wed Jul 9 15:04:22 2008 steveMetaphysicsPhotosSURFs helping handsSurf students are helping out with baffle
cleaning.
 surfjob.png 
  651   Wed Jul 9 12:42:14 2008 JohnUpdateLockingHand off to RF CARMRob, Yoichi, John

Last night we were able to reduce the CARM
 LongLock080709.png 
  650   Tue Jul 8 21:58:22 2008 albertoUpdateGeneralSecondaty beam aligned to the IFO beam againYesterday the alignment of the secondary beam
to the IFO was completely lost and today
I had to realign all the optics before I
  
  649   Tue Jul 8 21:46:38 2008 YoichiConfigurationPSLGC650M moved to the PMC transmissionI moved a GC650M, which was monitoring the
light coming out of the PSL, to the transmission
port of the PMC to see the transmitted mode
  
  648   Tue Jul 8 12:25:54 2008 JohnSummaryPSLISS gain set to 2dB    
  647   Tue Jul 8 10:26:30 2008 MashaUpdateAuxiliary lockingsetup updatesYesterday I changed one of the beam splitters
in the Mach Zehnder to one with a more stable
mount as to reduce the system's coupling
  
  646   Tue Jul 8 10:20:10 2008 steveUpdatePEMHEPA turned onIt is specially important to run the PSL-HEPA
filters when inside counts is peaking at
30,000 counts
 hepa.jpg 
  645   Tue Jul 8 08:16:56 2008 steveUpdatePSLPMC problemThe PMC is unhappy. PMC auto locker is not
working.
DC output slider adjust has to be moved from
 pmc.jpg 
  644   Tue Jul 8 00:14:28 2008 JohnSummaryComputersAlarm handlerRob thought it would be nice to have some
alarms on the cpu loads and FE syncs.
I added all these channels to the alarm handler
  
  643   Mon Jul 7 19:15:38 2008 AlbertoUpdateGeneralOptics alignement on the ABS length experimentToday I started setting up the PLL instruments
to lock the frequency of the NPRO beam to
the IFO beam. with no need of a new alignment
  
  642   Mon Jul 7 16:30:08 2008 steveUpdatePSLPSL-PEM 16 days trendThis morning the laser head temp was up to
20.3C  because the laser chiller was overflowing.
I removed 700 cc water. 
 pempsl16d.jpg 
  641   Mon Jul 7 14:02:05 2008 YoichiUpdateComputersSVN conversion progressSo far /cvs/cds/caltech/medm,  /cvs/cds/caltech/chans
and  /cvs/cds/caltech/scripts have been converted
to svn working copies.
  
  640   Mon Jul 7 13:58:37 2008 Eric, josephbDAQPEMUsing unused PEM channels to test camera codeJoe and I have taken control of the EPICS
channels C1:PEM-Stacis_EEEX_geo and C1:PEM-Stacis_EEEY_geo
since we heard that they are no longer in
  
  639   Mon Jul 7 13:49:27 2008 YoichiHowToPSLMZ offset, gain tipsJohn, Yoichi

This morning John found that MZ servo is
  
  638   Mon Jul 7 13:06:38 2008 KojiUpdateGeneralBeats of the two lasers in the absolute length measurement observed One may need an RF filter after the mixer.
I expect the SR560 does work for this purpose.
If it does not, a passive LPF can be used.
  
  637   Mon Jul 7 11:22:02 2008 AlbertoUpdateGeneralBeats of the two lasers in the absolute length measurement observed I didn't post a screenshot from the RF SA
because I had troubles with the interface
with the computer (unfortunately the network
  
  636   Sun Jul 6 16:17:40 2008 tobinHowToComputersSVNI was able to check out the 40m SVN here in
Livingston using this command:
  
  635   Thu Jul 3 22:54:45 2008 KojiUpdateGeneralBeats of the two lasers in the absolute length measurement observed Great! Conguraturation! I wish if I could
see it! It's nice if you can put the photo
or anything of the RF spectrum analyzer.
  
  634   Thu Jul 3 18:48:09 2008 AlbertoUpdateGeneralBeats of the two lasers in the absolute length measurement observed I adjusted the alignment of the flipper mirror
as suggested by Koji making the two beam
spots match. I also aligned all the IFO mirrors
  
  633   Thu Jul 3 16:57:23 2008 JohnSummaryGeneralFSS_RMTEMPThe FSS room temp alarm has been beeping a
lot recently. I altered the FSS_RMTEMP alarm
levels using the
 FSStime.pngFSSalarm.png 
  632   Thu Jul 3 16:18:51 2008 robSummaryLockingspecgramsI used ligoDV to make some spectrograms of
DARM_ERR (1), QPDX (2), and QPDY (3).  These
show the massive instability from 30-40Hz
 darm_specg.pngqpdx_specg.pngqpdy_specg.png 
  631   Thu Jul 3 13:54:26 2008 robConfigurationComputersmDV on rosalba
Does mDV work on rosalba?  It can't find
[B][FONT=Courier New]NDS_GetChannels[/FONT][/B].
  
  630   Thu Jul 3 13:12:32 2008 Rob, Yoichi, JohnUpdateLockingMore oscillationsBounce/ roll filters were added to the short
degrees of freedom to reduce the effect of
the 24Hz line seen on Tuesday night.
 LOL.pngNoisyX080702.pngPOXforCARM080702.png 