IDdown Date Author Type Category Subject Text Attachments
  1242   Wed Jan 21 22:53:08 2009 ranaUpdateLSCAS CCD centering and ASDD demod phaseJust my opinion, but I think all we want out
of the DD signals is something to control
the DRM
  
  1241   Wed Jan 21 16:18:17 2009 KakeruUpdateLSCAS CCD centering and ASDD demod phaseI tuned the DD demod-pahse for SRM.
It was tuned as the error singnal is to be
0 when the cavity is locked.
  
  1240   Tue Jan 20 15:28:42 2009 YoichiUpdateComputersloadLIGOData a GUI for mDV[quote]The tool is very nice; I looked at
the seismic trend for 16 days (attached).
 MC_F.png 
  1239   Mon Jan 19 18:21:41 2009 ranaUpdateComputersloadLIGOData a GUI for mDVThe tool is very nice; I looked at the seismic
trend for 16 days (attached). 
However, it gives some kind of error when
 a.png 
  1238   Mon Jan 19 15:10:37 2009 YoichiHowToComputersloadLIGOData a GUI for mDVI installed loadLIGOData, a product of my
weekend project, in  /cvs/cds/caltech/apps/loadLIGOData.
This is a Matlab GUI for getting data from
 loadLIGOData.pngplotLigoData.png 
  1237   Mon Jan 19 13:58:53 2009 YoichiUpdateASCBetter ditherServo.plNick Smith (@LHO) tested the ditherServo.pl
at Hanford.
He added options to specify exit conditions
  
  1236   Fri Jan 16 18:45:20 2009 YoichiConfigurationIOOMC_L gain increased by a factor of 2Rana, Yoichi

Since we fixed the FSS AOM double-pass, which
 MC_F-MC_L-xover.pdfMC_F.pdf 
  1235   Fri Jan 16 18:33:54 2009 YoichiSummaryComputersc1lsc rebooted to fix 16Hz glitchesKakeru, Yoichi

There were 16Hz harmonics in the PD3 and
  
  1234   Fri Jan 16 18:29:08 2009 YoichiUpdateSUSOplevs QPDs centeredKakeru centered ITMX and BS optical levers
with the help of Jenne on the walkie-talkie.
  
  1233   Fri Jan 16 18:25:32 2009 Yoichi, Kakeru, RanaUpdateLSCArms were unstableThe single arm lock had been unstable for
both arms in the past few days.
 TRXY.pdfErrorSignals.pdfcoherenceBetweenArms.pdfArmPowersAfterPDwasCentered.pdf 
  1232   Fri Jan 16 11:33:59 2009 robConfigurationDMFDMF start script[quote]I tried to restart the DMF using the
start_all script: http://dziban.ligo.caltech.edu:40/40m/280
  
  1231   Fri Jan 16 11:28:54 2009 YoichiUpdateComputersLab. laptop needs wireless lan driver updateOne of the lab. laptops (belladonna) cannot
connect to the network now.
I guess this was caused by someone clicked
  
  1230   Thu Jan 15 22:30:32 2009 ranaConfigurationDMFDMF start scriptI tried to restart the DMF using the start_all
script: http://dziban.ligo.caltech.edu:40/40m/280
  
  1229   Thu Jan 15 09:19:32 2009 steveUpdateIOOMC locking MC2 sus damping was found tripped at the morning
the second time this week.
  
  1228   Wed Jan 14 15:53:32 2009 steveDAQPSLMC temperature sensor[quote]I added a channel for the temperature
sensor on the MC1/MC3 chamber: C1:PSL-MC_TEMP_SEN.
To do that I had to reboot the frame builder.
  
  1227   Wed Jan 14 10:59:06 2009 steveBureaucracyVACrga waiting to be "connected"We have no RGA data since old Dycor passed
away in the middle of Oct, 2008
New SRS-RGA200 was installed on the vac envelope
  
  1226   Wed Jan 14 09:22:43 2009 steveHowToVACN2 supply pressure lowered for vac valves[quote]I've been replacing the N2 bottles
recently.
I noticed that the consumption is too high.
 n280d.jpg 
  1225   Tue Jan 13 18:59:09 2009 KakeruUpdateLSCAS CCD centering and ASDD demod phaseI tuned the demod-phase for PRCL and SRCL
hand-off, but it have not been optimized
enoughly.
  
  1224   Tue Jan 13 11:10:42 2009 robConfigurationComputersconlogger restartedunknown how long it's been down.     
  1223   Mon Jan 12 18:53:03 2009 YoichiUpdateLSCAS CCD centering and ASDD demod phaseAfter Rob's AS beam work, I centered the beam
on the AS CCD.
I also optimized the ASDD demod-phase for
  
  1222   Mon Jan 12 10:57:38 2009 robUpdateGeneralsome stuff
The AS beam was not hitting the AS166 diode,
so I aligned the last little steering mirror
  
  1221   Fri Jan 9 17:30:10 2009 KakeruUpdateComputersSnapshots of MEDM screensI wrote a web page which shows snapshots of
MEDM screens generated by Yoich's script
(e-log #1206).
  
  1220   Fri Jan 9 16:52:18 2009 steveUpdateVACtp3 forline pump replacedAlberto took 40m vacuum 101 class as we replaced
the drypump at the annulus pump line.
  
  1219   Fri Jan 9 09:14:17 2009 steveUpdatePEMifo is recovered after eqThere is no obvious damage from last night
earth quake.
All sus dampings were turned on, MC locked
 eq4.5sb.jpg 
  1218   Thu Jan 8 20:26:17 2009 robOmnistructureGeneralEarthquake in San BernardinoMagnitude 4.5
Date-Time
  
  1217   Thu Jan 8 16:49:37 2009 ranaConfigurationloreHP 5550dtn (Grazia) set up on allegra[quote]I set up printing to grazia from allegra.
The CUPS interface was not as straightforward
as Tobin had made it seem in the Wiki. I
  
  1216   Mon Jan 5 11:21:05 2009 AlanOmnistructureComputer Scripts / ProgramsNew 40mWebStatus[quote]
I guess we need some kind of "official" crontab
file for controls@nodus so that we know how/where
  
  1215   Sun Jan 4 13:17:23 2009 AlanOmnistructureComputer Scripts / ProgramsNew 40mWebStatusI have set up some code in /cvs/cds/caltech/scripts/webStatus
along with a cronjob on controls@nodus to
generate a webStatus every half hour, at
  
  1214   Fri Jan 2 18:49:54 2009 YoichiUpdateLSCLSC modulation frequencies adjustedI noticed that the IFO did not lock in the
MICH configuration.
This was because AS166Q signal was too small.
  
  1213   Fri Jan 2 17:20:44 2009 ranaSummaryComputer Scripts / Programs40m GWINCI have made a '40m' directory in the iscmodeling
CVS tree which allows one to run a 40m version
of GWINC.
 bench40.pdf 
  1212   Thu Jan 1 01:15:45 2009 YoichiSummaryVACN2 line leak ?I've been replacing the N2 bottles recently.
I noticed that the consumption is too high.
I had to replace them every two days.
  
  1211   Thu Jan 1 01:07:03 2009 YoichiSummaryEnvironmentParticle counts going crazyI increased the fan speed of the PSL HEPA
filter to the maximum.
  
  1210   Thu Jan 1 00:55:39 2009 YoichiUpdateASCAlignment scripts for LinuxA Happy New Year.

The dither alignment scripts did not run
  
  1209   Wed Dec 31 22:59:40 2008 YoichiSummaryEnvironmentParticle counts going crazyYes it is a new year's eve, and a lot of crazy
people are on Colorado to secure seats for
the parade tomorrow.
  
  1208   Tue Dec 30 18:51:18 2008 rana,yoichiConfigurationElectronicsIlluminator Power Supply reset[COLOR=blue][B]We noticed that none of the
illuminators were working.[/B][/COLOR]
  
  1207   Mon Dec 29 21:51:02 2008 YoichiConfigurationComputersWeb server on nodusThe apache on nodus has been solely serving
for the svn web access.
I changed the configuration and all files
  
  1206   Mon Dec 29 21:38:57 2008 YoichiUpdateComputersSnapshots of MEDM screensI wrote scripts to take snapshots of MEDM
screens in the background.
These scripts work even on a computer without
  
  1205   Mon Dec 29 18:01:07 2008 AidanUpdateAuxiliary lockingUpdated 40m Upgrade Document T080074-00-R
Added a paragraph to the 40m Upgrade document
describing the fiber stabilization and frequency
  
  1204   Wed Dec 24 12:46:54 2008 YoichiUpdateComputersTest points are backRob told me how to restart the test point
manager.
It runs on fb40m and actually there is an
  
  1203   Wed Dec 24 10:33:24 2008 YoichiUpdateComputersSeveral fixes. Test point problem remains.Yesterday, I fixed several remaining problems
from the power failure.
  
  1202   Tue Dec 23 10:35:40 2008 YoichiUpdateComputersRFM network breakdown mostly fixedRana, Rolf, Alberto, Yoichi

The source of the problem was the RFM bypass
  
  1201   Mon Dec 22 13:48:22 2008 YoichiUpdateComputersRFM network bypass box's power supply is dead As a temporary fix, I cut the cable of the
power supply and connected it to the Sorensen
power supply +5V on the rack.
  
  1200   Sun Dec 21 14:18:04 2008 YoichiUpdateComputersRFM network bypass box's power supply is dead I restarted the front-end computers by power
cycling them one-by-one.
After issuing startup commands, most of them
  
  1199   Sun Dec 21 13:00:06 2008 steveUpdateall down cond.vac and laser back onThere was a power outage sometimes early Saturday.

All things are down.
  
  1198   Sat Dec 20 23:37:43 2008 robOmnistructureGeneralSaturday Night Fever after presumed power failure
Just came by to pick something up...
  
  1197   Fri Dec 19 16:38:09 2008 steveUpdateLSCall optlevs centeredAll optlevs were centered after full alignment.

Qpd sums are:
  
  1196   Fri Dec 19 14:35:58 2008 Yoichi AlbertoUpdateIOOMC WFS and IOO-POS QPD re-centeringFor the past two days, the MC alignment has
kept drifting.
This morning, the MC alignment was so bad
  
  1195   Fri Dec 19 11:29:16 2008 Alberto, YoichiConfigurationMZMZ Trans PDLately, it seems that the matching of the
input beam to the Mode Cleaner has changed.
Also, it is drifting such that it has become
  
  1194   Fri Dec 19 11:18:52 2008 AlbertoConfigurationGeneralMode Cleaner Temperature MonitorI reduced from 10 to 5 the gain of the SR560
that Caryn has set up after the lock-in amplifier
nest to the PSL rack because the overload
  
  1193   Thu Dec 18 19:15:54 2008 Alberto, YoichiConfigurationSUSMode Cleaner Cavity Alignment[quote]This morning I found the MC locked
to the 10 mode. When I locked it on the 00
mode, it was unstable and eventually it always
  