ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
8003
|
Tue Feb 5 12:08:43 2013 |
Max Horton | Update | Summary Pages | Updating summary pages | Getting started: Worked on
understanding the functionality of summary_page.py.
The problem with the code is that it was |
|
8055
|
Mon Feb 11 13:07:17 2013 |
Max Horton | Update | Summary Pages | Fixed A Calendar Bug | Understanding the Code: Documented
more functions in summary_pages.py.
Since it is very difficult and slow to understand |
|
8098
|
Mon Feb 18 11:54:15 2013 |
Max Horton | Update | Summary Pages | Timing Issues and Calendars | Crontab: The bug of data only plotting
until 5PM is being investigated. The
crontab's final call to the summary page |
|
8148
|
Sat Feb 23 16:16:11 2013 |
Max Horton | Update | Summary Pages | Multiprocessing | Calendars: The calendar issue
discussed previously (http://nodus.ligo.caltech.edu:8080/40m/8098)
where the numbers are squished together |
|
8194
|
Wed Feb 27 22:46:53 2013 |
Max Horton | Update | Summary Pages | Multiprocessing Implementation | Overview: In order to make the code
more maintainable, I need to factor it into
different well-documented classes. |
|
8195
|
Wed Feb 27 23:19:54 2013 |
rana | Update | Summary Pages | Multiprocessing Implementation | At first I thought that this
was goofy, but then I logged in and saw that
Megatron only has 8GB of RAM. I guess that |
|
8201
|
Thu Feb 28 14:19:20 2013 |
Max Horton | Update | Summary Pages | Multiprocessing Implementation | Okay, more memory would definitely be good.
I don't think I have been using MEDM (which
Jamie tells me is the controls interface) |
|
8218
|
Mon Mar 4 10:41:18 2013 |
Max Horton | Update | Summary Pages | Multiprocessing Implementation | Update:
Upon investigation, the other methods
besides process_data() take almost no time |
|
8227
|
Mon Mar 4 21:05:49 2013 |
Max Horton | Update | Summary Pages | Multiprocessing and Crontab | Multiprocessing: In its current
form, the code uses multiprocessing to the
maximal extent possible. It takes roughly |
|
8273
|
Mon Mar 11 22:28:30 2013 |
Max Horton | Update | Summary Pages | Fixing Plot Limits | Quick Note on Multiprocessing:
The multiprocessing was plugged into the
codebase on March 4. Since then, the various |
|
8286
|
Wed Mar 13 15:30:37 2013 |
Max Horton | Update | Summary Pages | Fixing Plot Limits | Jamie has informed me of numpy's numpy.savetxt()
method, which is exactly what I want for |
|
8414
|
Thu Apr 4 13:39:12 2013 |
Max Horton | Update | Summary Pages | Graph Limits | Graph Limits: The limits on graphs
have been problematic. They often reflect
too large of a range of values, usually because |
|
8476
|
Tue Apr 23 15:02:19 2013 |
Max Horton | Update | Summary Pages | Importing New Code | Duncan Macleod (original author of summary
pages) has an updated version that I would
like to import and work on. The code |
|
8496
|
Fri Apr 26 15:50:48 2013 |
Max Horton | Update | Summary Pages | Importing New Code |
I am following the instructions here:
https://www.lsc-group.phys.uwm.edu/daswg/docs/howto/lal-install.html#test |
|
8504
|
Mon Apr 29 15:35:31 2013 |
Max Horton | Update | Summary Pages | Importing New Code |
I installed the new version
of LAL on allegra. I don't think it |
|
8523
|
Thu May 2 14:14:10 2013 |
Max Horton | Update | Summary Pages | Importing New Code |
LALFrame was successfully installed.
Allegra had unmet dependencies with some |
|
8536
|
Tue May 7 15:09:38 2013 |
Max Horton | Update | Summary Pages | Importing New Code |
I am now working on megatron,
installing in /home/controls/lal. I |
|
8572
|
Tue May 14 16:14:47 2013 |
Max Horton | Update | Summary Pages | Importing New Code | I have figured out all the issues, and
successfully installed the new versions of
the LAL software. I am now going to |
|
11411
|
Tue Jul 14 16:47:18 2015 |
Eve | Update | Summary Pages | Summary page updates continue during upgrade | I've continued to make changes to the
summary pages on my own environment, which
I plan on implementing on the main summary |
|
11414
|
Tue Jul 14 17:14:23 2015 |
Eve | Summary | Summary Pages | Future summary pages improvements | Here is a list of suggested improvements
to the summary pages. Let me know if there's
something you'd like for me to add to |
|
11437
|
Wed Jul 22 22:06:42 2015 |
Eve | Summary | Summary Pages | Future summary pages improvements | - CDS Tab
We want to monitor the status of the |
|
11448
|
Mon Jul 27 17:51:06 2015 |
Eve | Update | Summary Pages | New summary page tabs and other improvements | The summary pages can still be found at https://nodus.ligo.caltech.edu:30889/detcharsummary/ (EDIT:
in an older version of this post I listed |
|
11467
|
Thu Jul 30 14:27:18 2015 |
Eve | Update | Summary Pages | ALS, ASC, LSC Summary Pages | I've switches the ALS, ASC, and LSC
plots on the summary pages from plotting
raw frames, to plotting minute trends, instead. |
|
11474
|
Sat Aug 1 17:04:29 2015 |
Eve | Update | Summary Pages | States and Triggers in SPs | I've added states to the summary pages
to only show data for times at which one
certain channel is above a specified threshold. |
|
11480
|
Wed Aug 5 17:15:08 2015 |
Eve | Update | Summary Pages | Fixed ASC Tab | I've fixed the ASC
tab on the summary pages to populate
the graphs with data without causing an error. |
|
11585
|
Wed Sep 9 11:33:58 2015 |
rana | Update | Summary Pages | Summary Page updates |
Made most plots in IOO tab only
plot when MC_TRANS > 10000 using Eve's
MC_LOCK state definition.
added |
|
12703
|
Wed Jan 11 19:20:23 2017 |
Max Isi | Update | Summary Pages | December outage | The summary pages were not successfully
generated for a long period of time at the
end of 2016 due to syntax errors in the PEM |
|
12709
|
Thu Jan 12 23:22:34 2017 |
rana | Update | Summary Pages | December outage | Pages still not working: PEM and MEDM blank.
Committed existing MEDM
grabbing scripts to SVN. Ran the cron job |
|
12713
|
Fri Jan 13 14:33:00 2017 |
MAX (not Rana) | Update | Summary Pages | December outage | PEM config file was also lacking a section
named "summary", which is necessary
for all parent tabs; this has now been solved. |
|
12749
|
Tue Jan 24 07:36:56 2017 |
Max Isi | Update | Summary Pages | Cluster maintenance | System-wide CIT LDAS cluster maintenance may
cause disruptions to summary pages today.
|
|
12752
|
Wed Jan 25 09:00:39 2017 |
Max Isi | Update | Summary Pages | Cluster maintenance | LDAS has not recovered from maintenance causing
the pages to remain unavailable until further
notice.
|
|
12787
|
Thu Feb 2 11:25:45 2017 |
Max Isi | Update | Summary Pages | Cluster maintenance | FYI this issue has still not been solved,
but the pages are working because I got the
software running on an
|
|
12831
|
Wed Feb 15 22:16:05 2017 |
Max Isi | Update | Summary Pages | New condor_q format | There has been a change in the default
format for the output of the condor_q command
at CIT clusters. This could be problematic |
|
12870
|
Mon Mar 6 14:47:49 2017 |
gautam | Update | Summary Pages | Code status check script modified | For a few days now, the "code status"
page
has been telling us that the summary pages |
|
13049
|
Wed Jun 7 14:27:23 2017 |
Steve | Update | Summary Pages | summery pages not working | Last good page May 18, 2017
Not found, error message May 19
- June 4,2017 |
|
224
|
Thu Jan 3 12:38:49 2008 |
rob | Bureaucracy | TMI | Sore throat | [quote]
I did not feel anything wrong yesterday,
but [COLOR=red]unfortunately I have [/COLOR] |
|
229
|
Wed Jan 9 20:29:47 2008 |
Dmass | AoG | TMI | Coffee Carafe | If you have been using the coffee machine
in the 40m, you may have noticed small brown
flecks in your coffee mug. The carafe in |
  |
279
|
Mon Jan 28 12:42:48 2008 |
Dmass | Bureaucracy | TMI | Coffee | There is tea in the coffee carafe @ the 40m.
It is sitting as though it were fresh coffee.
There is also nothing on the post it. |
|
341
|
Tue Feb 26 20:24:04 2008 |
Andrey | Summary | TMI | Sorrow | As for that plot of three-dimensional surface,
I indeed was wrong with the axis "Q_ETMX-Q_ITMX"
(I put there wrong string "Q_ITMX-Q_ETMX"). |
|
2887
|
Thu May 6 17:47:01 2010 |
Alberto, kiwamu, Jc The 3rd (aka The Drigg) | Omnistructure | TMI | Minutes from the Lab Organization Commitee meeting | Today we met and we finally come up with
a lot of cool, clever, brilliant, outstanding
ideas to organize the lab. |
|
2888
|
Thu May 6 17:54:44 2010 |
Zach Korth -- Committee Oversight (Fun Division) | Omnistructure | TMI | Minutes from the Lab Organization Commitee meeting | Where are we going to put the tiki bar?
The ice cream machine? I am disappointed
in the details that appear to have been glossed |
|
14041
|
Fri Jul 6 12:12:09 2018 |
Annalisa | Configuration | Thermal Compensation | Thermal compensation setup | I tried to put together a rudimentary heater
setup.
As a heating element, I used the |
   |
14043
|
Sat Jul 7 19:50:38 2018 |
Annalisa | Configuration | Thermal Compensation | Study about the Thermal projection setup and its effect on the cavity | I made some simulation to study the change
that the heater setup can induce on the Radius
of Curvature of the ETM. |
6x |
14050
|
Tue Jul 10 23:44:23 2018 |
Annalisa | Configuration | Thermal Compensation | Heater setup assembly | [Annalisa, Koji]
Today both the heater and the reflector
were delivered, and we set down the setup |
8x |
14071
|
Fri Jul 13 23:39:46 2018 |
Annalisa | Configuration | Thermal Compensation | Thermal compensation setup - power supply | [Annalisa, Rana]
In order to power the heater setup
to be installed in the ETMY chamber, |
  |
14078
|
Tue Jul 17 17:37:46 2018 |
Annalisa, Terra | Configuration | Thermal Compensation | Heaters installation | Summary
We
installed two heaters setup on the ETMY bench
in order to try inducing some radius of curvature |
6x |
14086
|
Thu Jul 19 04:44:09 2018 |
Annalisa, Terra | Summary | Thermal Compensation | frequency shift observed with heating! | Annalisa, Gautum, Koji, Terra
Summary: with
the reflector setup, we measured a frequency |
  |
14094
|
Sat Jul 21 01:06:49 2018 |
gautam | Summary | Thermal Compensation | Y arm locking | I implemented this today. For now, the
LSC output matrix is set to actuate on MC2
for Y arm locking. As expected, the transmission |
|
14096
|
Sat Jul 21 14:03:19 2018 |
Koji | Summary | Thermal Compensation | Y arm locking | Ah. With MC2 feedback, we have about 3
times smaller "optical gain" for
the ASS A2L. We have same dither, same actuator, |
|
14103
|
Wed Jul 25 14:45:59 2018 |
Sandrine | Summary | Thermal Compensation | ETM Y Table AUX read out | Attached is a photo of the set up of the
ETM Y table showing the AUX read out set
up. |
|