  15542   Wed Aug 26 16:12:25 2020 gautamUpdateElectronicsTest mass coil current requirementsAttachment
#1 is a summary of
 coilCurrents.png 
  15543   Wed Aug 26 22:49:47 2020 gautamUpdateElectronicsCheckout of Trek Model 603I unboxed
the Trek amplifier today, and performed some
basic tests of the functionality. It seems
 IMG_8951.JPG 
  15545   Fri Aug 28 23:33:38 2020 gautamUpdateBHDSome more hardware changesJust a quick set of notes detailing changes
so that there are no surprises, more details
to follow.
  
  15546   Sat Aug 29 18:52:42 2020 ranaUpdateIOOIMC gain changeI lowered
the (FAST) PZT gain on the IMC/FSS servo
today.
  
  15547   Sat Aug 29 20:07:48 2020 ranaUpdateElectronicsWFS characterizationI set up to do the WFS head modifications
today, but I was shot down in flames due
to a missing AC/DC adapter.
  
  15548   Sat Aug 29 22:10:09 2020 gautamUpdateElectronicsWFS characterizationClearly this "riff raff" is referring
to me. It won't help today I guess but
there is one each on the carts holding the
  
  15549   Sat Aug 29 22:46:29 2020 gautamUpdateBHDNew homodyne-phase control electronicsSummary:

The electronics chain used to drive
the three elements of the PI PZT on which
 zetaDrive.pdftrekTFs.pdf 
  15550   Sun Aug 30 11:29:33 2020 ranaUpdateGeneralpower blink?My power at home winked out for a second
this morning, but it looks like either nothing
happened in the 40m lab or else it rode it
  
  15551   Tue Sep 1 01:49:49 2020 KojiUpdateElectronicsTeledyne AP1053 etc were transportedTeledyne AP1053 etc were transported from
Rich's office to the 40m. The box is
placed on the shelf at the entrance.
 20200831203756_IMG_9931.jpg20200831203826_IMG_9932.jpg20200831205126_IMG_9934.jpg 
  15552   Tue Sep 1 15:39:04 2020 gautamUpdateElectronicsHV coil driver oscillations fixedSummary:

Increasing the compensation capacitance
(470 pF now instead of 33 pF) seems to have
 testSetup.pdfHVampNoise_driven.pdf 
  15553   Wed Sep 2 00:49:47 2020 gautamUpdateBHDSome notes about homodyne phaseSummary:

Using a heterodyne measurement
setup to track both quadratures, I estimated
 heterodyneMICH.pdfunwrappedPhase.pdfunwrappedPhase_zoom.pdfphaseNoisePSD.pdf 
  15554   Thu Sep 3 00:00:57 2020 gautamUpdateBHDNew patch cable installed
10m PM1064 cable was installed.
I tried a double shielding approach (photos
tmrw here),
  
  15555   Thu Sep 3 15:55:04 2020 gautamUpdateBHDPhase drift between LO and IFO after fiber replacementSummary:

After replacement of the fiber
delivering the LO beam to the airBHD setup
 LOphaseDrift.pdfphaseDrift_tempCorr.png 
  15556   Fri Sep 4 15:26:55 2020 JonUpdateVACVac system UPS installationThe vac controls are going down now to
pull and test software changes. Will advise
when the work is completed.
  
  15557   Fri Sep 4 21:12:51 2020 JonUpdateVACVac system UPS installationThe vac work is completed. All of the vacuum
equipment is now running on the new 120V
UPS, except for TP1. The 230V TP1 is still
  
  15558   Sat Sep 5 12:01:10 2020 JonUpdateVACVac system UPS installationSummary

Yesterday's UPS
switchover was mostly a success. The new
Tripp
 vac_medm.pngvac_medm.png 
  15559   Sat Sep 5 14:28:03 2020 KojiUpdateGeneralLO beam: Fiber coupling work2PM: Arrived at the 40m. Started the work
for the coupling of the RF modulated LO beam
into a fiber. -> I left the lab
 20200905212254_IMG_9938.JPG 
  15560   Sun Sep 6 13:15:44 2020 JonUpdateDAQUPS for framebuilderNow that the old APC
Smart-UPS 2200 is no longer in use by
the vacuum system, I looked into whether
  
  15561   Sun Sep 6 14:17:18 2020 JonUpdateEquipment loanZurich Instruments analyzerOn Friday, I grabbed the Zurich Instruments
HF2LI lock-in amplifier and brought
it home. As time permits, I will work towards
  
  15562   Mon Sep 7 23:49:14 2020 gautamUpdateBHDA first look at RF44 schemeSummary:

Over the last couple of days, I've
been working towards getting the infrastructure
  
  15563   Tue Sep 8 01:31:43 2020 KojiUpdateBHDA first look at RF44 scheme- Loose fiber coupler: Sorry about that.
I could not detect something was loose there,
although some of the locks were not tightened.
  
  15564   Tue Sep 8 11:49:04 2020 gautamUpdateCDSSome path changesI edited /diskless/root.jessie/home/controls/.bashrc
so that I don't have to keep doing this
  
  15565   Wed Sep 9 00:05:18 2020 gautamUpdateBHDMore notes on the RF44 schemeSummary:


With the Michelson locked
on a dark fringe, the f2-f1 signal at ~44
 IMG_3397.JPGphaseNoisePSD.pdfmagnitudeHist.pdfLOpowerDrift.png 
  15567   Thu Sep 10 15:43:22 2020 JonUpdateBHDInput noise spectra for A+ BHD modelingAs promised some time ago, I've
obtained input noise spectra from the sites calibrated
to physical units. They are located in a
  
  15568   Thu Sep 10 15:56:08 2020 KojiUpdateGeneralHEPA & Particle Level Status15:30
- PSL HEPA was running
at 33% and 
  
  15569   Mon Sep 14 07:50:01 2020 YehonathanUpdateBHDMonte Carlo SimulationsTurns out what was causing the instability
in the aLIGO plots were the lock
commands which I forgot to remove before
 10x 
  15570   Tue Sep 15 10:57:30 2020 gautamUpdatePSLPMC re-locked, RGA re-enabledThe PMC has been unlocked since September
11 sometime (summary pages are flaky again).
I re-locked it just now. I didn't mess
 RGAscan.pdf 
  15571   Tue Sep 15 12:20:36 2020 gautamUpdateElectronicsSR785 repairedThe unit was repaired and returned to the
40m. Now, with a DMM, I measure a DC offset
value that is ~1% of the AC signal amplitude.
 dividerTF.pdf 
  15572   Tue Sep 15 17:04:43 2020 gautamUpdateElectronicsDC adaptors deliveredThese were delivered to the 40m today and
are on Rana's desk

  
  15573   Tue Sep 15 17:19:09 2020 gautamUpdateIOOMC F spectrum There was an abrupt change in the MC_F
spectrum between August
4 and August
 MCF_MCL.pdf 
  15574   Tue Sep 15 19:17:30 2020 ranaUpdateIOOMC F spectrum that's a very curious disconnection

the "Pentek" whitening
board that carries the MC channels has jumpers
  
  15575   Tue Sep 15 22:11:52 2020 gautamUpdateBHDMore notes on the RF44 schemeSummary:

After more trials, I
 RF44.pdf 
  15576   Wed Sep 16 09:43:41 2020 gautamUpdateIOOMC F spectrum This
elog suggests that there is uniformly
1 stage engaged across all channels. I didn't
 MCF_MCL.pdf 
  15577   Wed Sep 16 12:03:07 2020 JonUpdateVACReplacing pressure gaugesAssembled is the list of dead pressure
gauges. Their locations are also circled
in Attachment 1.
 vac_gauges.png 
  15578   Wed Sep 16 17:44:27 2020 gautamUpdateCDSAll vertex FE models restartedI had to make a CDS change to the c1lsc
model in an effort to get a few more signals
into the models. Rather than risk requiring
 CDS.png 
  15579   Fri Sep 18 10:47:48 2020 gautamUpdateBHDSensing scheme for homodyne phaseeSummary:

I
 fieldQuads.pdfPMAMratio.pdf 
  15580   Sat Sep 19 01:49:52 2020 KojiUpdateGeneralM4.5 EQ in LAM4.5 EQ in LA 2020-09-19 06:38:46 (UTC)
/ -1d 23:38:46 (PDT) https://earthquake.usgs.gov/earthquakes/eventpage/ci38695658/executive

I only checked the watchdogs. All
  
  15581   Sat Sep 19 11:27:04 2020 ranaUpdateGeneralM4.5 EQ in LAthe seismometers obviously saturated during
the EQ, but the accelerometers captured some
of it. It looks like there's different
 Sep18-EQ.pdf 
  15582   Sat Sep 19 18:07:35 2020 KojiUpdateVACTP3 RP failureI came to the campus and Gautam notified
that he just had received the alert from
the vac watchdog.
 vac.pngScreen_Shot_2020-09-19_at_17.52.40.png 
  15583   Sat Sep 19 18:08:34 2020 ranaUpdateGeneralM4.5 EQ in LAthe EQ was ~14 km south of Caltech and
17 km deep

  
  15584   Sat Sep 19 18:46:48 2020 KojiUpdateGeneralHand soapI supplied a bottle of hand soap. Don't
put water in the bottle to dilute it as it
makes the soap vulnarable for cotamination.
  
  15585   Sat Sep 19 19:14:59 2020 KojiUpdateGeneralITMX released / ETMY UR magnet knocked offThere were two SUSs which didn't look
normal.

- ITMX was easily released by the
 IMG_6218.jpeg 
  15586   Sat Sep 19 19:37:16 2020 not KojiUpdateVACTP3 RP failureDisconcerting because those tip seals were
just replaced [15417].
Maybe they were just defective, but if there
  
  15588   Sun Sep 20 11:41:54 2020 gautamUpdateGeneralIMC re-lockedWhile I stopped by the lab this morning
to pick up some things, I took the opportunity
to continue the recovery.
  
  15590   Mon Sep 21 12:40:58 2020 gautamUpdateGeneralWorkable IFO recoverySee Attachment
#1.
 IFOrecovery.pngIMG_5345.JPG 
  15591   Mon Sep 21 15:57:08 2020 JordanUpdateVACTP3 Forepump Replacement and Vac resetI removed the forepump (Varian SH-110)
for TP3 today to see why it had failed over
the weekend. I tested it in the C&B lab
 Screenshot_from_2020-09-21_15-56-04.png20200921_145043.jpg20200921_145040.jpg 
  15592   Mon Sep 21 16:40:52 2020 gautamUpdatePSLHEPAs are no longer runningThe HEPA filters on the PSL enclosure are
no longer running. I tried cycling the power
switch on the NW corner of the enclosure,
  
  15595   Tue Sep 22 16:29:30 2020 KojiUpdateGeneralControl Room AC setting for continuous runningI came to the lab. The control room AC
was off -> Now it is on.

Here is the setting of the AC meant
 P_20200922_161125.jpg 
  15596   Tue Sep 22 22:38:11 2020 gautamUpdateBHDSensing scheme for homodyne phase - some analytic calcsI got some feedback from Koji who pointed
out that the phase tracker is not required
here. This situation is similar to the phase
 simpleMich.pdf.zip 
  15597   Tue Sep 22 23:16:54 2020 KojiUpdateGeneralHEPA InspectionGautam reported that the PSL HEPA stopped
running (ELOG
15592). So I came in today and started
 11x 
ELOG V3.1.3-