  15703   Thu Dec 3 14:53:58 2020 JonUpdateVACReplacing pressure gaugesUpdate to the gauge replacement plan (15692),
based on Jordan's walk-through today.
  
  15704   Thu Dec 3 20:38:46 2020 gautamUpdateASCElectrical LO signal for AS WFSI removed the Frequency Generation box
from the 1X2 rack. For the time being, the
PSL shutter is closed, since none of the
 RF_Frequency_Source.pdfdemodPath.pdfEOMpath.pdf 
  15705   Thu Dec 3 21:14:38 2020 KojiUpdateASCElectrical LO signal for AS WFSLet's use RG405 for better shielding.
It is not too stiff. The bending  (just
once) does not break the cable.
  
  15706   Thu Dec 3 21:44:49 2020 gautamUpdateASCElectrical LO signal for AS WFSI'm open to either approach. If the
full replacement requires a lot of machining,
maybe I will stick to just the 55 MHz line.
  
  15707   Fri Dec 4 03:02:40 2020 KojiUpdateASCElectrical LO signal for AS WFS1. That's true. But we are already
in that regime with the Var attn at 0dB,
aren't we? We can reduce the input to
  
  15708   Fri Dec 4 15:58:22 2020 KojiUpdateIOOWFS2 broken I checked the backplane connection for
IMC WFS2  and found that the
cables for IMC WFS2 and the IMC demod were
  
  15709   Fri Dec 4 19:23:40 2020 KojiUpdateElectronicsAA/AI board testing ongoingI have the setup built for the AA/AI board
testing around the PD testing area. Please
let me leave it like that for a week or so.
  
  15710   Fri Dec 4 22:41:56 2020 gautamUpdateASCFreq Gen Box revampThis turned out to be a much more involved
project than I expected. The layout is complete
now, but I found several potentially damaged
  
  15711   Sat Dec 5 20:44:35 2020 gautamUpdateASCFreq Gen Box re-installedThis work is now complete. The box was
characterized and re-installed in 1X2. I
am able to (briefly) lock the IMC and see
 6x 
  15712   Mon Dec 7 11:25:31 2020 gautamUpdateSUSMC1 suspension glitchy againThe MC1 suspension has begun to show
evidence of glitches again, from Friday/Saturday.
You can look at the suspension Vmon tab a
  
  15713   Mon Dec 7 12:38:51 2020 gautamUpdateIOOIMC loop charSummary:

There seems to be significant phase
loss in the TTFSS path, which is limiting
 OLTFcomparison.pdfdemodMons.pdfOLTFcomparison.pdf 
  15714   Mon Dec 7 14:32:02 2020 gautamUpdateLSCNew demod phases for POX/POY lockingIn favor of keeping the same servo gains,
I tuned the digital demod
phases for the POX and POY photodiode signals
 POX_POY_OLTF.pdfPOX_POY_spectra.pdf 
  15715   Mon Dec 7 22:54:30 2020 gautamUpdateLSCModulation depth measurementSummary:

I measured the modulation depth
at 11 MHz andf 55 MHz using an optical beat
 modDepth.pdf 
  15716   Tue Dec 8 15:07:13 2020 gautamUpdateComputer Scripts / Programsndscope updatedI updated the ndscope on rossa to a bleeding
edge version (0.7.9+dev0)
 test.pdf 
  15717   Wed Dec 9 11:54:11 2020 gautamUpdateOptical LeversITMX HeNe replacedThe ITMX Oplev (installed in March 2019)
was near end of life judging by the SUM channel
(see 
 OLtrend_old_ndscope.pngITMX_OL_P.pdfITMX_OL_Y.pdf 
  15718   Wed Dec 9 12:02:04 2020 gautamUpdateLSCPOX locking still unsatisfactoryContinuting the IFO recovery - I am unable
to recover similar levels of TRX RIN as I
had before. 
 armRIN.pdfPOX_OLTF.pdf 
  15719   Wed Dec 9 15:37:48 2020 gautamUpdateCDSRFM switch IP addr resetI suspect what happened here is that the
IP didn't get updated when we went from
the 131.215.113.xxx system to 192.168.113.xxx
 Screenshot_2020-12-09_15-39-20.pngScreenshot_2020-12-09_15-46-46.png 
  15720   Wed Dec 9 16:22:57 2020 gautamUpdateSUSYet another round of Sat. Box. switcharooAs discussed at the meeting, I decided
to effect a satellite box swap for the misbehaving
MC1 unit. I looked back at the summary pages
 WFS2.pngWFS_lineNoise.pngWFSchar.pdf 
  15721   Wed Dec 9 20:14:49 2020 gautamUpdateVACUPS failureSummary:


The (120V) UPS at the vacuum
rack is faulty.
The drypump backing
 rackBeforenAfter.pdfIMG_0008.jpgIMG_0009.jpgvacStatus.png 
  15722   Thu Dec 10 11:07:24 2020 ChubUpdateVACUPS faultIs that a fault code that you can decipher
in the manual, or just a light telling you
nothing but your UPS is dead?
  
  15723   Thu Dec 10 11:17:50 2020 ChubUpdateVACUPS faultI can't find anything in the manual
that describes the nature of the FAULT message. 
In fact, it's not mentioned at all. 
  
  15724   Thu Dec 10 13:05:52 2020 JonUpdateVACUPS failureI've investigated the vacuum controls
failure that occurred last night. Here's
what I believe happened.
 TP2_time_history.pngslow_controls_monitors.png 
  15725   Thu Dec 10 14:29:26 2020 gautamUpdateVACUPS failureI don't buy this story - P2 only briefly
burped around GPStime 1291608000 which is
around 8pm local time, which is when I was
 vacDiag1.png 
  15727   Thu Dec 10 14:48:00 2020 YehonathanUpdateBHDMonte Carlo SimulationsI have rebuilt the MCMC simulation in an
OOP fashion and incorporated Lance/Pytickle
functionality into it. The usage of the MCMC
 MCMCLance_NoiseBudget_Example.pdfIFO_Check.pdf 
  15728   Thu Dec 10 16:24:13 2020 gautamUpdateEquipment loanNoliac PZT --> PacoI gave one Noliac PZT from the two spare
in the metal PMC kit to Paco. There is one
spare left in the kit.
  
  15729   Thu Dec 10 17:12:43 2020 JonUpdate New SMA cables on orderAs requested, I placed an order for an
assortment of new RF cables: SMA male-male,
RG405.
  
  15730   Thu Dec 10 22:45:42 2020 gautamUpdateSUSMore spare OSEMsI acquired several spare OSEMs (in unknown
condition) from Paco. They are stored alongside
the shipment from UF.
  
  15731   Thu Dec 10 22:46:57 2020 gautamUpdateASCWFS head assembledThe assembly of the head is nearly complete,
I thought I'd do some characterization
before packaging everything up too nicely.
 aLIGO_wfs_v5_40m.pdfTF_meas.pdf 
  15732   Fri Dec 11 09:28:52 2020 ranaUpdateBHDMonte Carlo loop coupling SimulationsCool. Can you give us Bode plots of the
open loop gain for each of the 5 length control
loops?
  
  15734   Mon Dec 14 11:09:28 2020 YehonathanUpdateBHDMonte Carlo loop coupling SimulationsI spent a few hours monkeying around with
the control filters. They are totally made
up and also it's my first time trying
 MCMC_LANCE_OLTFs.pdfMCMC_LANCE_OLCoupling2DARM.pdf 
  15735   Tue Dec 15 12:38:41 2020 gautamUpdateElectronicsDC power stripI installed a DC power strip (24 V
variant, 12 outlets available) on the NW
upright of the 1X1 rack. This is for the
  
  15736   Thu Dec 17 15:23:56 2020 gautamUpdateASCWFS head characterizationSummary:

I think the WFS head performs satisfactorily.


The (input-referred) dark
 oNoise.pdfZ_Hi.pdfZ_Low.pdfIMG_9030.jpgiNoise.pdf 
  15737   Fri Dec 18 10:52:17 2020 gautamUpdateCDSRFM errors As I was working on the IFO re-alignment
just now, the rfm errors popped up again.
I don't see any useful diagnostics on
 RFMdiag.png 
  15739   Sat Dec 19 00:25:20 2020 JonUpdate New SMA cables on orderI re-ordered the below cables, this
time going with flexible, double-shielded
RG316-DS.
  
  15740   Sat Dec 19 02:42:56 2020 KojiUpdate New SMA cables on orderOur favorite (flexible) RF cable is Belden's
1671J (Jacketed solder-soaked coax cable).
It is compatible RG405. I'm not sure
  
  15741   Sat Dec 19 20:24:25 2020 gautamUpdateElectronicsWFS hardware installI installed 4 chassis in the rack 1X2 (characterization
on the E-bench was deemed satisfactory, I
will upload the analysis later). I ran out
  
  15743   Mon Dec 21 18:18:03 2020 gautamUpdateCDSMany model changesThe CDS model change required to get the
AS WFS signals into the RTCDS system are
rather invasive.
 CDSoverview.png 
  15744   Tue Dec 22 22:11:37 2020 gautamUpdateCDSAA filt repaired and reinstalledKoji fixed the problematic channel - the
issue was a bad solder joint on the input
resistors to the THS4131. The board was re-installed.
  
  15745   Wed Dec 23 10:13:08 2020 gautamUpdateCDSNear term upgradesSummary:


There appears to be insufficient
 IMG_0020.pdf 
  15747   Sun Jan 3 16:26:06 2021 KojiUpdateSUSIMC WFS check (Yet another round of Sat. Box. switcharoo)I wanted to check the functionality of
the IMC WFS. I just turned on the WFS servo
loops as they were. For the past two hours,
 Screen_Shot_2021-01-03_at_17.14.57.png 
  15748   Wed Jan 6 15:28:04 2021 gautamUpdateVACVac rack UPS batteries replaced[chub, gautam]

the replacement was done this afternoon.
The red "Replace Battery" indicator
  
  15749   Wed Jan 6 16:18:38 2021 gautamUpdateOptical LeversBS Oplev glitchyAs part of the hunt why the X
arm IR transmission RIN is anomalously high,
I noticed that the BS Oplev Servo periodically
 missingData.pngOLRIN.pdfBS_OL_P.pdfBS_OL_suppression.pdf 
  15750   Wed Jan 6 19:00:04 2021 gautamUpdateLSCPhase loss in POX/POY loopsI've noticed that there is some phase
loss in the POX/POY locking loops - see 
 POXloop.pdfloopFit.pdf 
  15751   Wed Jan 6 22:47:41 2021 gautamUpdateALSNoisy ALSSummary:

I want to get back to locking the
interferometer so I can test out the newly
 ALSX_excess.pngbudget.pdf 
  15752   Thu Jan 7 19:16:11 2021 gautamUpdateALSNoisy ALSI'm also wondering why the error monitors
for the X and Y loops report such wildly
different spectra for the suppressed frequency
 ALS_ERR_MON.pdfAUXnoise.pdf 
  15753   Thu Jan 7 20:07:27 2021 KojiUpdateALSNoisy ALSHow about resurrecting the PSL table green
beat for the X arm to see if the non-fiber
setup shows the same level of the freq noise
  
  15754   Thu Jan 7 21:16:22 2021 gautamUpdateALSNoisy ALSI thought about it, but wouldn't that
show up at the AUX PDH error point? Or because
the loop gain is so high there we wouldn't
  
  15755   Thu Jan 7 23:25:19 2021 KojiUpdateALSNoisy ALSIf the sensing noise level of the end PDH
degraded for some reason, it'd make the
out of loop stability worse without making
  
  15756   Fri Jan 8 20:01:11 2021 gautamUpdateALSNoisy ALSI did this test today. The excess
noise around 100 Hz doesn't show up in
the green beat.
 ALSX_IR_green.pdf 
  15758   Mon Jan 11 16:11:51 2021 YehonathanUpdateBHDMonte Carlo loop coupling SimulationsI dived into the alog to make the OLTFs
in the MC_controls example more realistic.
I was mainly inspired by these entries:
 MC_LANCE_OLTFs.pdf 
ELOG V3.1.3-