40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 320 of 335  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  16089   Wed Apr 28 10:56:10 2021 Anchal, PacoUpdateSUSIMC Filters diagnosedGood
morning!
 7x 
  16090   Wed Apr 28 11:31:40 2021 JonUpdateVACEmpty N2 TanksI checked out what happened on c1vac. There
are actually two independent monitoring codes
running:
  
  16091   Wed Apr 28 17:09:11 2021 AnchalUpdateSUSTuned Suspension Parameters uploaded for long term behavior monitoringI have uploaded all the new settings mentioned
in 16066
and 16072.
  
  16092   Wed Apr 28 18:56:57 2021 Yehonathan, JonUpdateCDSUpdated c1auxey wiring planWe took a Supermicro from the lab (along
with a keyboard, a mouse, and a screen taken
from a table on the Y arm) and placed it
  
  16093   Thu Apr 29 10:51:35 2021 JonUpdateCDSI/O Chassis AssemblySummary

Yesterday I unpacked
and installed the three 18-bit DAC cards
received from Hanford. I then repeated the
  
  16094   Thu Apr 29 10:52:56 2021 AnchalUpdateSUSIMC Trans QPD and WFS loops step response testIn 16087
we mentioned that we were unable to do a
step response test for WFS loop to get an
 PIT_OFFSET_ON_MC2.pngYAW_STEP_ON_MC2_complete.png 
  16095   Thu Apr 29 11:51:27 2021 AnchalSummaryLSCStart of measuring IMC WFS noise contribution in ar cavity length noiseTried locking the arms


Ran IFO > Configure
> ! (YARM) > Restore YARM. Nothing
  
  16096   Thu Apr 29 13:41:40 2021 Ian MacMillanUpdateCDSSUS simPlant modelTo add the required library: put the .mdl
file that contains the library into the userapps/lib folder.
That will allow it to compile correctly
 Non-IPC_Plant.pdf 
  16097   Thu Apr 29 15:11:33 2021 gautamUpdateCDSRFM The problem here was that the RFM errors
cropped up again - seems like it started
~4am today morning judging by TRX trends.
 RFM_errs.pngScreenshot_2021-04-29_15-12-56.png 
  16098   Thu Apr 29 16:35:51 2021 YehonathanUpdateCDSUpdated c1auxey wiring planI installed the EPICs base, asyn and modbus
modules according to Jon's
instructions.
  
  16099   Thu Apr 29 17:43:16 2021 KojiUpdateCDSRFM The other day I felt hot at the X end.
I wondered if the Xend A/C was off, but the
switch right next to the SP table was ON
  
  16100   Thu Apr 29 17:43:48 2021 AnchalUpdateCDSF2A Filters double checkI double checked today and the F2A filters
in the output matrices of MC1, MC2 and MC3
in the POS column are ON. I do not get what
 F2AFiltersON.png 
  16101   Thu Apr 29 17:51:19 2021 AnchalSummaryLSCStart of measuring IMC WFS noise contribution in arm cavity length noiset Both arms were locked simply by using
IFO > Configure > ! (YARM) > Restore
YARM. I had to use ASS to improve the TRX/TRY
 WFS1_PIT_exc_80-100Hz_Arms_ASD.pdf 
  16102   Thu Apr 29 18:53:33 2021 AnchalUpdateSUSIMC Suspension Damping Gains TestWith the input matrix, coil ouput gains
and F2A filters loaded as in 16091,
I tested the suspension loops' step response
 MC1_SUSDampGainTest.pdfMC2_SUSDampGainTest.pdfMC3_SUSDampGainTest.pdf 
  16103   Thu Apr 29 19:55:45 2021 YehonathanUpdateCDSUpdated c1auxey wiring planWe received a stock of DB9 male feed-through
connectors. That allowed me to complete the
remaining wiring on the c1auxey Acromag chassis.
  
  16104   Fri Apr 30 00:18:40 2021 gautamSummaryLSCStart of measuring IMC WFS noise contribution in arm cavity length noiseThis is the actuator calibration.
For the error point calibration, you have
to look at the filter in the calibration
  
  16105   Fri Apr 30 00:20:30 2021 gautamUpdateCDSF2A Filters double checkThe SDF system is supposed to help with
restoring the correct settings, complementary
to burt. My personal opinion is that there
  
  16106   Fri Apr 30 12:52:14 2021 Ian MacMillanUpdateCDSSUS simPlant modelNow that the model is finally compiled
I need to make an medm screen for it and
put it in the c1sim:/home/controls/docker-cymac/userapps/medm/ directory. 
  
  16107   Fri Apr 30 19:18:51 2021 Yehonathan, JonUpdateCDSUpdated c1auxey wiring planWe finished the installation procedure
on the c1auxey1 host machine. There were
some adjustments that had to be made for
  
  16108   Mon May 3 09:14:01 2021 Anchal, PacoUpdateLSCIMC WFS noise contribution in arm cavity length noiseLock
ARMs
 WFS1_PIT_Noise_Inj_Test_IMC_unlocked.pdfWFS1_PIT_Noise_Inj_Test_ARM_locked.pdf 
  16109   Mon May 3 13:35:12 2021 Ian MacMillanUpdateCDSSUS simPlant modelWhen the cymac is started it gives me a
list of channels shown below. 

  
  16110   Mon May 3 16:24:14 2021 AnchalUpdateSUSIMC Suspension Damping Gains Test Repeated with IMC unlockedWe repeated the same test with IMC unlocked.
We had found these gains when IMC was unlocked
and their characterization needs to be done
 MC1_SusDampGainTest.pdfMC2_SusDampGainTest.pdfMC3_SusDampGainTest.pdf 
  16111   Mon May 3 16:49:04 2021 YehonathanUpdateBHDSOS assemblyI found a "vice" in the cleanroom
(attachment 1). I used it to push dowel pins
into the last suspension block using some
 20210503_161422.png20210503_161456.jpg 
  16112   Mon May 3 17:28:58 2021 Anchal, Paco, RanaUpdateLSCIMC WFS noise contribution in arm cavity length noiseRana came and helped us figure us where
to inject the noise. Following are the characteristics
of the test we did:
 excitationoftheMCanglessothatwecanseesomethingdotpng.pngexcitationoftheMCanglessothatwecanseesomethingdotpngbutthistimeitsMC2.png 
  16113   Mon May 3 18:59:58 2021 AnchalSummaryGeneralWeird gas leakagr kind of noise in 40m control roomFor past few days, a weird sound of decaying
gas leakage comes in the 40m control room
from the south west corner of ceiling. Attached
 40mNoiseFinal.mp3 
  16114   Mon May 3 20:36:46 2021 Yehonathan, JonUpdateCDSUpdated c1auxey wiring planIt seemed like the BIO channels were not
working, both the inputs and the outputs.
The inputs were working on the windows machine
  
  16115   Mon May 3 23:28:56 2021 KojiSummaryGeneralWeird gas leakagr kind of noise in 40m control roomI also noticed some sound in the control
room. (didn't open the MP3 yet)

I'm afraid that the hard disk
  
  16116   Tue May 4 07:38:36 2021 JonUpdateCDSI/O Chassis AssemblyIOP models created

With all
the PCIe issues now resolved, yesterday I
proceeded to build an IOP model for
 Screen_Shot_2021-05-03_at_4.16.06_PM.png 
  16117   Tue May 4 11:43:09 2021 Anchal, PacoUpdateLSCIMC WFS noise contribution in arm cavity length noiseWe redid the WFS noise injection test and
have compiled some results on noise contribution
in arm cavity noise and IMC frequency noise
 ArmCavNoiseContributions.pdfIOO-MC1_PIT_NoiseInjTest2.pdfIOO-MC1_PIT_NoiseInjTest_AWGGUI_Config.png 
  16118   Tue May 4 14:55:38 2021 Ian MacMillanUpdateCDSSUS simPlant modelAfter a helpful meeting with Jon, we realized
that I have somehow corrupted the sitemap
file. So I am going to use the code
  
  16119   Tue May 4 19:14:43 2021 YehonathanUpdateGeneralOSEMs from KAGRAI put the box containing the untested OSEMs
from KAGRA near the south flow bench on the
floor.
  
  16120   Wed May 5 09:04:47 2021 AnchalUpdateSUSNew IMC Suspension Damping Gains uploaded for long term testingWe have uploaded the new damping gains
on all the suspensions of IMC. This completes
changing all the configuration to as mentioned
  
  16121   Wed May 5 13:05:07 2021 ChubUpdateGeneralchassis delivery from De LeoneAssembled chassis from De Leone placed
in the 40 Meter Lab, along the west wall
and under the display pedestal table. 
 de_leone_del_5-5-21.jpg 
  16122   Wed May 5 15:11:54 2021 Ian MacMillanUpdateCDSSUS simPlant modelI added the IPC parts back to the plant
model so that should be done now. It looks
like this again here.
  
  16124   Thu May 6 16:13:24 2021 Ian MacMillanUpdateCDSSUS simPlant modelWhen using mdl2adl I
was getting the error:

  
  16125   Thu May 6 16:13:39 2021 AnchalSummaryIMCAngular actuation calibration for IMC mirrorsHere's my first attempt at doing angular
actuation calibration for IMC mirrors using
the method descibed in /users/OLD/kakeru/oplev_calibration/oplev.pdf
 IMC_Ang_Act_Cal_Kakeru_Tests.pdf 
  16126   Fri May 7 11:19:29 2021 Ian MacMillanUpdateCDSSUS simPlant modelI copied c1scx.mdl
to the docker to attach to the plant using
the commands:
  
  16127   Fri May 7 11:54:02 2021 Anchal, PacoUpdateLSCIMC WFS noise contribution in arm cavity length noiseWe today measured the calibration factors
for XARM_OUT and YARM_OUT in nm/cts and replotted
our results from 16117
 ITMX-XARM_TF.pdfITMY-YARM_TF.pdfArmCavNoiseContributions.pdf 
  16128   Mon May 10 10:57:54 2021 Anchal, PacoSummaryCalibrationUsing ALS beatnote for calibration, testTest details:


We
locked both arms and opened the shutter for
Yend green laser.
After toggling
 BeatY_ITMY_CalibrationAt57Hz.pdfBeatY_ITMY_CalibrationAt43Hz.pdfBeatY_ITMY_CalibrationAt77Hz.pdf 
  16129   Mon May 10 18:19:12 2021 Anchal, PacoUpdateLSCIMC WFS noise contribution in arm cavity length noise, CorrectionsA few corrections to last analysis:


The first plot was not
IMC frequency noise but actually MC_F noise
 ArmCavNoiseContributions.pdf 
  16130   Tue May 11 16:29:55 2021 JonUpdateCDSI/O Chassis Assembly


Quote:


 Screen_Shot_2021-05-11_at_3.03.42_PM.png 
  16131   Tue May 11 17:43:09 2021 KojiUpdateCDSI/O Chassis AssemblyDid you match the local PC time with the
GPS time?
  
  16132   Wed May 12 10:53:20 2021 Anchal, PacoUpdateLSCPSL-IMC PDH Loop and XARM PDH Loop diagramAttached is the control loop diagram when
main laser is locked to IMC and a single
arm (XARM) is locked to the transmitted light
 IMC_SingleArm.pdf 
  16133   Wed May 12 11:45:13 2021 Anchal, PacoSummarySUSNew IMC Settings are miserableWe picked a few parameters from 40m summary
page and plotted them to see the effect of
new settings. On April 4th, old settings
 MC_F_Comparison.pdfMC_TRANS_QPD_Comparison.pdfIMC_REFL_DC_Comparison.pdf 
  16134   Wed May 12 13:06:15 2021 Ian MacMillanUpdateCDSSUS simPlant modelWorking with Chris, we decided that it
is probably better to use a simple filter
module as a controller before we make the
 SimplePlant_SingleContr.pdfx1sup_isolated.pdfX1SUP_ISOLATED_GDS_TP.pngX1SUP_ISOLATED_C1_SUS_SINGLE_PLANT_Plant_POS_Mod.png 
  16135   Wed May 12 14:23:20 2021 JordanUpdateSUSMass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI units   Moments_of_Inertia_SI.PNG 
  16136   Wed May 12 16:53:59 2021 KojiUpdateSUSMass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI unitsNo, this is the property of the suspension
assembly. The mass says 10kg

Could you do the same for the testmass
  
  16137   Wed May 12 17:06:52 2021 JordanUpdateSUSMass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI unitsHere are the mass properties for the only
the test mass assembly (optic, 3" ring,
and wire block). (Updated with g*mm^2)
 Moments_of_Inertia_SI.PNG 
  16138   Thu May 13 11:55:04 2021 Anchal, PacoUpdateSUSMC1 suspension misbehavingWe came in the morning with the following
scene on the zita monitor:

 Screenshot_from_2021-05-13_09-50-24.pngMC1_Glitches_Invest2.pdf 
  16139   Thu May 13 19:38:54 2021 AnchalUpdateSUSMC1 Satellite Amplifier Debugged[Anchal Koji]

Koji and I did a few tests with
an OSEM emulator on the satellite amplifier
 MC1_UL_Channel_Fixed.png 
ELOG V3.1.3-