  6580   Fri Apr 27 12:12:14 2012 DenUpdateCDSc1ioo is backRolf came to the 40m today and managed
to figure out what the problem is. Reading
just dmesg was not enough to solve the problem.
  
  6581   Fri Apr 27 13:32:06 2012 DenUpdatePEMseism channelsA few weeks ago I found that GUR2_X signal
is biased from 0 to 800 counts in average.
I decided that the corresponding channel
 pem.png 
  6593   Wed May 2 19:47:20 2012 DenUpdatePEMEM 172 nonlinearitiesI've checked new small EM172 microphones
for nonlinearities using Koji's Mac Book
speakers. EM172 + Mac nonlinearities are
 500Hz_noise.png 
  6594   Wed May 2 21:04:06 2012 DenUpdatePEMEM 172 coherenceI measured coherence between 2 EM 172 microphones
in a "quiet room" with SR785
 em_coh.png 
  6604   Sat May 5 01:24:07 2012 DenUpdatePSLPMCI was interested what whitening filter
do we have between MC servo and ADC. The
shape is in the figure below, SR provided
 whitening.jpgmcf_v.png 
  6606   Sat May 5 10:20:21 2012 DenUpdatePSLPMC

    

       
            
  
  6608   Sat May 5 20:42:59 2012 DenUpdatePSLPMC[Koji, Den]
Koji was right that I misaligned
everything during the alignment work. I assumed
  
  6609   Sun May 6 00:11:00 2012 DenUpdateCDSmx_streamc1sus and c1iscex computers could not connect
to framebuilder, I restarted it, did not
help. Then I restarted mx_stream daemon on
  
  6610   Sun May 6 01:41:55 2012 DenUpdatePEMseismic in x,y armsI locked x,y arms and measured coherence
between POS{X,Y}11_I_ERR, MC_F and seismometer
signals.
 coh_xyf.png 
  6611   Mon May 7 01:07:58 2012 DenUpdateIOOseismic in mcfI tried to figure out where additional
(to seismic) noise enters to MC_F, so the
coherence below 1 Hz is low (~0.2-0.5). I've
 pd-mcf.jpegfb.pngcoh_err_fb.pngmc2_suspos.jpg 
  6612   Mon May 7 12:57:34 2012 DenUpdateIOOWFS noise in MCI've measured coherence between seismometer
signals and OSEMS of MC 1,2,3
 gur_suspos_coh.pngmc1_gur.pngmcl_wfs.pngwfs_servo.png 
  6613   Mon May 7 17:28:29 2012 DenUpdateIOOWFS noise in MC

    

       
            
 wfs_limit.png 
  6615   Mon May 7 20:15:37 2012 DenUpdateIOOWFS noise in MC

    
      
  
  6616   Mon May 7 21:05:38 2012 DenUpdateCDSbiquad filter formI wanted to switch the implementation of
IIR_FILTER from DIRECT FORM II to BIQUAD
form in C1IOO and C1SUS models. I modified
  
  6618   Mon May 7 21:46:10 2012 DenUpdateCDSguralp signal errorGUR1_XYZ_IN1 and GUR2_XYZ_IN1 are the same
and equal to GUR2_XYZ.  
 guralps.png 
  6619   Mon May 7 22:39:37 2012 DenUpdateCDSc1sus[Jenne, Den]
We decided to reboot C1SUS machine
in hope that this will fix the problem with
  
  6623   Tue May 8 09:58:17 2012 DenUpdateCDSSUS -> FB [Alex, Den] 
It
  
  6624   Tue May 8 10:43:42 2012 DenUpdateCDSbiquad filter form

    

       
            
  
  6632   Wed May 9 10:46:54 2012 DenUpdateCDSOAF model not seeing MCL correctly

    

       
            
 oaf_rec.png 
  6633   Wed May 9 11:31:50 2012 DenUpdateCDSRFMI added PCIE memory cache flushing to c1rfm
model by changing 0 to 1 in /opt/rtcds/rtscore/release/src/fe/commData2.c
on line 159, recompiled and restarted c1rfm.
  
  6635   Wed May 9 15:02:50 2012 DenUpdateCDSRFM

    

       
            
  
  6638   Thu May 10 21:13:01 2012 DenUpdateElectronicsADC 3ADC 3 INPUT 4 (#3 in the c1pem model if
you count from 0) is bad. It adds DC = ~1
V to the signal as well as noise. I plugged
  
  6639   Thu May 10 22:05:21 2012 DenUpdateCDSFBAlready for the second time today all computers
loose connection to the framebuilder. When
I ssh to framebuilder DAQD process was not
  
  6642   Fri May 11 23:33:41 2012 DenUpdateAdaptive Filteringoffline vs onlineI've compared offline Wiener filtering
with online static + adaptive filtering for
MC_F with GUR1_XYZ and GUR2_XYZ as witness
 off_on.jpg 
  6651   Sun May 20 19:57:51 2012 DenUpdatePEMmicrophonesI've soldered EM172 microphones to BNC
connectors to get data from them.
 7x 
  6655   Tue May 22 00:23:45 2012 DenUpdateCDStransmission error monitorI've started to create channels and an
medm screen to monitor the errors that occur
during the transmission through the RFM model.
 Screenshot.png 
  6661   Tue May 22 20:01:26 2012 DenUpdateCDSerror monitorI've created transmission error monitors
in rfm, oaf, sus, lsc, scx, scy and ioo models.
I tried to get data from every channel transmitted
  
  6664   Tue May 22 23:36:02 2012 DenUpdatePEMmircophonesI've put 5 EM172 microphones close together
and measured there signal and coherence.
They are plugged in to accelerometer channels.
 6x 
  6670   Thu May 24 01:17:13 2012 DenUpdateCDSPMC autolocker

    

       
            
  
  6671   Thu May 24 02:55:36 2012 DenUpdatePEMacoustic noise in MCLMic in the PSL showed that fluctuations
in the MCL in the frequency range 10 - 100
Hz are due to acoustic noise. I've measured
 audio_noise.png 
  6673   Thu May 24 12:23:00 2012 DenUpdateGeneralconnection error monitor for the websiteThe main page of connection error monitor
can be a scheme of computers and models with
connections. If there is an error in connection,
 errors_overview.pngerrors.png 
  6674   Thu May 24 13:28:38 2012 DenUpdatePEMHEPAHEPA filter was running at 90% of max.
I reduced it to 20%. Acoustic noise moved
down
 psl_acoustic.pngmcl_90.pngmcl_20.png 
  6680   Fri May 25 02:56:44 2012 DenUpdateSUSMC3 local dampingI've terminated input to AA filters and
measured signal to coils C1:SUS-MC3_??COIL_OUT.
 DSC_4305.JPGosem_noise.pngosem_coil.png 
  6681   Fri May 25 13:24:48 2012 DenUpdateSUSMC3AA IN -> COIL DRIVER IN transfer function
for MC3
 freq_resp.pngtest_dig.png 
  6689   Sat May 26 00:08:41 2012 DenUpdateIOOMC_F low frequency noise MC_F low frequency noise might be
due to local damping electronics. I did not
measure OSEM noise, but even without it electronics
 osem_noise.pnggur_suspos_coh.pngmc_noises.pngdgur.pngratio.png 
  6691   Sat May 26 15:59:19 2012 DenUpdateIOOGuralp noise is highAs I've mentioned in yesterday's
elog MC mirrors start to move in a synchronistic
manner. I've plotted DELTA_GUR = GUR1_X -
 gur_noise.pngMCF_GUR.pngDSC_4306.JPG 
  6692   Sat May 26 20:40:48 2012 DenUpdatePEMexperiments with seismic noiseI measured relative motion of 2 seismometers
separated by 4, 18 and 38 feet.
 DSC_4307.JPGDSC_4308.JPGsim_delta.pngratio.pngpsd_distance.png 
  6693   Sat May 26 23:57:11 2012 DenUpdatePEMGuralp noiseI've looked through the Guralp manual to
figure out what noise do they declare. They
present it in acceleration units in dB relative
 noises.png 
  6695   Sun May 27 23:15:22 2012 DenUpdatePEMexperiments with seismometersI wondered if linoleum is a reason of high
Guralp noise. I measured Guralp noise in
3 cases: they stand on a very soft piece
 DSC_4309.JPGDSC_4310.JPGDSC_4311.JPGloc_noise.png 
  6696   Tue May 29 00:35:57 2012 DenUpdatePEMguralp readout boxI measured the frequency response of the
Guralp readout box and noise by providing
sin signal of amplitude 50 mV at 15 Hz for
 1_3.png 
  6697   Tue May 29 00:39:52 2012 DenUpdatePEMGuralp noiseI've connected Guralp output to the ADC
without readout box. I've got the same noise
at low frequencies and even worse noise at
 in_out.png 
  6698   Tue May 29 00:48:51 2012 DenUpdatePEMsts readout boxSTS readout box seems to be partly broken.
I've terminated inputs from the seismometer
and measured the output. I could not do this
 sts_box.png 
  6699   Tue May 29 00:53:57 2012 DenUpdateCDSproblemsI've noticed several CDS problems:

    Communication sign on
C1SUS model turns to red once in a while.
  
  6712   Tue May 29 22:48:37 2012 DenUpdatePEMGuralp noiseI've checked whether the Guralp noise that
we see comes not from seismometer but from
ADC or readout box. I did 2 separate measurements
 split_noises.png 
  6721   Wed May 30 22:51:32 2012 DenUpdatePEMguralp isolation boxWhen I've put Guralps inside the isolation
box, the signal from seismometers increased
and was out of AA board range. I've reduced
 lin_box_noise.png 
  6730   Thu May 31 11:38:19 2012 DenUpdatePEMisolation systemI've put Guralps into the Steve's 2 box
isolation system. Noise got better, coherence
between 2 seismometers improved. We still
 lin_box_noise2.pnglin_box_coh.png 
  6747   Sun Jun 3 01:30:07 2012 DenUpdatePEMsts-2 and guralp in isolation boxWe have 2 sts-2 readout box - pink and
blue. Pink outputs 12 DVC - this a problem
of amplifier. This box has a rectifier (the
 DSC_4315.JPGDSC_4319.JPGlin_box_noise.pngmcl_gur.png 
  6748   Sun Jun 3 23:50:00 2012 DenUpdateCDSbiquad=1From now all models calculate iir filters
using biquad form. I've added biquad=1 to
cdsParameters to all models except c1cal,
  
  6806   Tue Jun 12 17:29:28 2012 DenUpdateCDSdq channelsAll PEM and IOO DQ channels disappeared.
These channels were commented in C1???.ini
files though I've uncommented them a few
  
  6872   Mon Jun 25 21:54:52 2012 DenUpdateComputer Scripts / ProgramsPMC locker

    

       
            
  