40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 315 of 335  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  15835   Tue Feb 23 20:55:19 2021 KojiUpdateSUSOSEM testing for SOSsI can't obtain a consistent view between
the existing drawings/photographs and your
pin assignment. Please review the pin assignment
 SOS_OSEM.pdf 
  15836   Tue Feb 23 23:12:37 2021 KojiSummarySUSSUS invacuum wiringThis is my current understanding
of the in-vacuum wiring:
1. Facts
 SOS_OSEM_cabling.pdf 
  15837   Wed Feb 24 10:09:16 2021 yehonathanUpdateSUSOSEM testing for SOSsYes, my phone camera mirrored the image.
Sorry for the confusion.

I see you already uploaded the
  
  15838   Wed Feb 24 10:23:03 2021 YehonathanUpdateSUSOSEM testing for SOSsContinuing with the new rig, I measure
the resistance of the cable leading to the
coil to be 0.08+(0.52-0.08)+(0.48-0.08)=0.9ohm.
 OSEM_078_LED_Spot.JPGOSEM_280_LED_Spot.JPGOSEM_117_LED_Spot.JPG 
  15839   Wed Feb 24 11:53:24 2021 gautamUpdateGeneralDemod char part 2I measured the noise of the I/F outputs
of all the LSC demodulators. I made the measurement
in two conditions, one with the RF input
 noises_noPreamp.pdfnoises_withPreamp.pdf 
  15840   Wed Feb 24 12:11:08 2021 gautamUpdateGeneralDemod char part 3I did the characterization discussed at
the meeting today.


RF signal at 100 Hz offset
 noPreamp.pdfwithPreamp.pdfnoPreamp_whitened.pdfwithPreamp_whitened.pdf 
  15841   Wed Feb 24 12:29:18 2021 gautamUpdateGeneralInput pointing recoveredWhile working at the LSC rack, I lost the
input pointing into the IFO (the TT wiring
situation is apparently very fragile, and
  
  15842   Wed Feb 24 22:13:47 2021 JonUpdateCDSPlanning document for front-end testingI've started writing up a rough testing
sequence for getting the three new front-ends
operational (c1bhd, c1sus2, c1ioo). Since
  
  15843   Thu Feb 25 14:30:05 2021 gautamUpdateCDSnew c1bhd setup - diskless bootI've set up one 2U server unit received
from KT in the control room area (the fans
in it are pretty loud but other than
  
  15844   Thu Feb 25 16:50:53 2021 gautamUpdateGeneralPRMI sensing matrixAfter all the work at the LSC rack over
the last couple of days, I re-locked the
PRMI (ETMs misaligned), and measured the
 PRMI1f_noArmssensMat.pdf 
  15845   Thu Feb 25 20:37:49 2021 gautamUpdateGeneralSetting modulation frequency and checking IMC offsetThe Marconi frequency was tuned by looking
at 


The ~3.68 MHz (= 3*f1 -
 modFreq.pdfIMC_offset.pdf 
  15846   Fri Feb 26 16:31:02 2021 gautamUpdateElectronicsProduction version of the HV coil driver tested with KEPCO HV suppliesKoji asked me to test the production version
of the coil driver with the KEPCO HV supplies.
See 
 totalNoise_KEPCO.pdf 
  15847   Fri Feb 26 20:20:43 2021 KojiUpdateElectronicsProduction version of the HV coil driver tested with KEPCO HV suppliesThis is very disappointing. Even with KEPCO
linear supply with the improved HV driver
circuit, the noise level is significantly
  
  15848   Sat Feb 27 17:25:42 2021 gautamUpdateElectronicsProduction version of the HV coil driver tested with KEPCO HV suppliesI will try the test of switching out KEPCOs
one at a time for the HP. Given that the
passive RC filter doesn't filter
  
  15849   Sun Feb 28 16:59:39 2021 rana, gautamUpdateLSCmore PRMI checks here: what it is ain't exactly clearOn Friday evening we checked out
a few more things, somewhat overlapping with
previous tests. All tests done with PRMI
 RAMestimate.png 
  15850   Sun Feb 28 22:53:22 2021 gautamUpdateLSCmore PRMI checks here: what it is ain't exactly clearI looked into this a bit more and crossed
off some of the points Rana listed. In order
to use REFL 55 as a sensor, I had to fix
 PRMI_SBres_REFL55.pngPRMI1f_noArmssensMat.pdfPRMI1f_noArmssensMat.pdfPRMI_locked.pngactTFs.pdf 
  15851   Mon Mar 1 11:40:15 2021 Anchal, PacoSummaryIMCgetting familiar with IMC controls[Paco, Anchal]

tl;dr: Done no harm, no
lasting change.
  
  15852   Mon Mar 1 12:36:38 2021 gautamSummaryIMCgetting familiar with IMC controlsPretty minor thing - but PMCT and PMCR
were switched on Quad 2 for whatever reason.
I switched them back because I prefer the
  
  15853   Mon Mar 1 16:27:17 2021 gautamUpdateLSCPRM violin filter excessive?The PRM violin filter seems very suboptimal
- the gain peaking shows up in the MICH OLTF,
presumably due to the MICH-->PRM LSC output
 violins.pdfPRviolin.pdf 
  15854   Tue Mar 2 13:39:31 2021 ranaUpdateLSCPRM violin filter excessive?agreed, seems excessive. I always prefer
bandstop over notch in case the eigenfrequency
wanders, but the bandstop could be made to
  
  15855   Tue Mar 2 19:52:46 2021 gautamUpdateLSCREFL55 demod board reworkThere were multiple problems with the REFL55
demod board. I fixed them and re-installed
the board. The TFs and noise measured on
  
  15856   Wed Mar 3 11:51:07 2021 YehonathanUpdateSUSOSEM testing for SOSsI finished testing the OSEMs. I put all
the OSEMs back in the box. The OSEMS were
divided into several bags. I put the OSEM
  
  15857   Wed Mar 3 12:00:58 2021 Paco, AnchalHowToIMCMC_F ASD[Paco, Anchal]

- Saved BURT backup in /users/anchal/BURTsnaps/
- Copied existing code for mode cleaner
 20210303_MC_F_Spectrum.pdf20210303_MC_F_Spectrum.tar.gz 
  15859   Wed Mar 3 22:13:05 2021 gautamUpdateLSCREFL55 demod board reworkAfter this work, I measured that the orthogonality
was poor. I confirmed on the bench that the
PQW-2-90
  
  15860   Wed Mar 3 23:23:58 2021 gautamUpdateALSArm cavity scanI see no evidence of anything radically
different from my PSL table optical
characterization in the IMC transmitted
 armScan.pdf 
  15861   Thu Mar 4 10:54:12 2021 Paco, AnchalSummaryLSCPOY11 measurement, tried to lock Green Yend laser[Paco, Anchal]

- First ran burtgooey as last time.

- Installed pyepics on base environment
 20210304_POY11_Spectrum_YARMLocked.pdf20210304_POY11_Spectrum_YARMLocked.tar.gz 
  15862   Thu Mar 4 11:59:25 2021 Paco, AnchalSummaryLSCWatchdog tripped, Optics damped backGautam came in and noted that the optics
damping watchdogs had been tripped by a >5
magnitude earthquake somewhere off the coast
  
  15863   Thu Mar 4 15:48:26 2021 KojiSummaryPEMWatchdog tripped, Optics damped backEQs seen on Summary pages
https://nodus.ligo.caltech.edu:30889/detcharsummary/day/20210304/pem/seismic_blrms/
  
  15864   Thu Mar 4 23:16:08 2021 KojiUpdateLSCREFL55 demod board reworkA new hybrid splitter (DQS-10-100) was
installed. As the amplification of the final
stage is sufficient for the input level of
 D990511-00_REFL55.pdfP_20210304_215602.jpgP_20210304_222400.jpgP_20210304_222412.jpg20210304234400_IMG_0526.jpg 
  15865   Thu Mar 4 23:57:35 2021 KojiSummaryElectronicsInspection of the new custom dsub cablesI made the inspection of the new custom
DSub cables (came from Texas).

The shelled version gives us some
 6x 
  15866   Fri Mar 5 00:53:09 2021 KojiSummaryElectronicsA bunch of electronics receivedReceived additional front/rear panels.
Updated the original entry and Wiki [Link]

 
  
  15867   Fri Mar 5 13:53:57 2021 gautamUpdateLSCREFL55 demod board rework0 dBm ~ 0.63 Vpp. I guess there is ~4dB
total loss (3dB from splitter
and 1dB from total excess loss above theoretical
  
  15868   Fri Mar 5 15:03:28 2021 gautamSummaryElectronicsA bunch of electronics receivedThe PCBs for the D1002593
BIO I/F (5pcs ea of D1001050
and D1001266)
  
  15869   Fri Mar 5 15:31:23 2021 KojiUpdateLSCREFL55 demod board reworkMissed to note: The IF test was done at
TP7 and TP6 using pomona clips i.e. brefore
the preamp.
  
  15870   Fri Mar 5 15:32:53 2021 KojiSummaryElectronicsA bunch of electronics receivedThe parts will be ordered by Koji
The components for the additional BIO I/F
have been ordered.
  
  15871   Fri Mar 5 16:24:24 2021 gautamUpdateLSCREFL55 demod board re-installed in 1Y2I don't have a good explanation why,
but I too measured similar numbers to what
Koji measured. The overall conversion gain
 REFL55.pdfdemodNoise.pdf 
  15872   Fri Mar 5 17:48:25 2021 JonUpdateCDSFront-end testingToday I moved the c1bhd machine from the
control room to a new test area set up behind
(west of) the 1X6 rack. The test stand is
 image_67203585.JPGimage_67216641.JPGimage_17185537.JPG 
  15873   Fri Mar 5 22:25:13 2021 gautamUpdateLSCPRMI 1f SB locking recoveredNow that the REFL55 signal chain is capable
of providing balanced, orthogonal readout
of the two quadratures, I was able to recover
 PRMI1f_noArmssensMat.pdf 
  15874   Sat Mar 6 12:34:18 2021 gautamUpdateLSCSensing matrix settings messed withTo my dismay, I found today that somebody
had changed the oscillator frequencies for
the sensing matrix infrastructure we have.
 sensMat.png 
  15875   Sun Mar 7 15:26:10 2021 gautamUpdateLSCHousekeeping + more PRMI
Beam pointing into PMC was tweaked
to improve transmission.
AS110
photodiode was re-installed on the AS table
 PRMI_SBres.pngMICH_act_calib.pdf 
  15876   Sun Mar 7 19:56:27 2021 AnchalUpdateLSCSensing matrix settings messed withI understand this mst be frustrating for
you. But we did not change these settings,
knowingly atleast. We have documented all
  
  15877   Mon Mar 8 12:01:02 2021 Paco, AnchalSummarytrainingInvestigate how-to XARM locking[Paco, Anchal]

- Started zoom stream; thanks to
whoever installed it!
  
  15878   Mon Mar 8 12:40:35 2021 gautamSummarytrainingInvestigate how-to XARM lockingFor the arm locking, the "Restore
Xarm (XARM POX)" script from the "IFO_CONFIGURE"
MEDM screen should get you there (I just checked
  
  15879   Mon Mar 8 12:54:54 2021 gautamUpdateEquipment loan40m-->Cryo
Busby box
SR554 transformer
preamplifier
  
  15880   Mon Mar 8 17:09:29 2021 gautamUpdateSUSPRM coil actuators heavily imbalancedI realized I hadn't checked the PRM
actuator as thoroughly as I had the others.
I used the Oplev as a sensor to check the
 PRMact.pdf 
  15881   Mon Mar 8 19:22:56 2021 ranaSummarySUSIMC suspension characterizationHerewith,
I describe an adventure
  
  15882   Mon Mar 8 20:11:51 2021 ranaFrogsComputer Scripts / Programsactivate_matlab out of control on Megatronthere were a zillion processes trying to
activate (this is the initial activation
after the initial installation) matlab 2015b
  
  15883   Mon Mar 8 22:01:26 2021 gautamUpdateLSCMore PRMIThere are still many mysteries remaining
- e.g. the MICH-->PRCL contribution still
can't be nulled. But for now, I have
 PRMI1f_noArmssensMat.pdfPRMI3f_noArmssensMat.pdf 
  15884   Tue Mar 9 10:57:06 2021 Paco, AnchalSummaryIMCXARM lock and POX spectra[Paco, Anchal]

- Upon arrival, MC is locked, and
we can see light in MON5 (PRM) (usually dark).
 20210309_POX11_Spec_XARMLocked.pdf20210309_XARM_Locked.tar.gz 
  15885   Tue Mar 9 12:41:29 2021 KojiSummaryElectronicsInvestigation on the invacuum Dsub cablesI believe the aLIGO style invac dsub cables
and the conventional 40m ones are incompatible.
While the aLIGO spec is that Pin1
 SOS_OSEM_cabling.pdf 
ELOG V3.1.3-