40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 315 of 341  Not logged in ELOG logo
ID Date Author Typedown Category Subject Text Attachments
  1528   Tue Apr 28 12:55:57 2009 CarynDAQPEMUnplugged Guralp channelsFor the purpose of testing out the temperature
sensors, I stole the PEM-SEIS_MC1X,Y,Z channels.
I unplugged Guralp NS1b, Guralp Vert1b,
  
  1540   Sat May 2 16:34:31 2009 carynDAQPEMGuralp channels plugged back in I plugged the Guralp cables back into the
PEM ADCU
      
  
  1643   Tue Jun 2 23:53:12 2009 peteDAQComputersreset c1susvme1rob, alberto, rana, pete
we reset this computer, which was
out of sync (16384 in the FE_SYNC field instead
  
  1661   Mon Jun 8 18:22:27 2009 AlbertoDAQLSCAdded PD11 I amd Q slow channelsI just added two slow channels to C0EDCUEPICS
to monitor the input of PD11. The names are:
[C1:LSC-PD11_I_INMON]
  
  1733   Sun Jul 12 20:06:44 2009 JenneDAQComputersAll computers downI popped by the 40m, and was dismayed to
find that all of the front end computers are
  
  1735   Mon Jul 13 00:34:37 2009 AlbertoDAQComputersAll computers down


   
        
            
  
  1736   Mon Jul 13 00:53:50 2009 AlbertoDAQComputersAll computers down


   
        
            
  
  1752   Wed Jul 15 17:18:24 2009 JenneDAQComputersDAQAWG gone, now backYet again, the DAQAWG flipped out for an
unknowable reason.  In order of restart
activities listed on the Wiki, I keyed the
  
  1769   Tue Jul 21 17:01:18 2009 peteDAQDAQtemp channel PEM-PETER_FEI added a temporary channel, to input 9
on the PEM ADCU.    Beware
the 30, 31, and 32 inputs.  I tried
  
  1831   Wed Aug 5 07:33:04 2009 steveDAQComputersfb40m is down    
  1832   Wed Aug 5 09:25:57 2009 AlbertoDAQComputersfb40m is upFB40m up and running again after restarting
the DAQ.
  
  1836   Wed Aug 5 15:33:05 2009 rob, albertoDAQGeneralcan't get trendsWe can't read minute trends from either
Dataviewer or loadLIGOData from before 11am
this morning. 
  
  1841   Thu Aug 6 09:22:17 2009 AlbertoDAQGeneralcan't get trends


   
        
            
  
  2365   Tue Dec 8 10:20:33 2009 AlbertoDAQComputersBootfest succesfully completedAlberto, Kiwamu, Koji,
this morning we found the RFM network
and all the front-ends down.
  
  2874   Mon May 3 19:21:43 2010 AlbertoDAQEnvironmentBoot fest[Alberto, Koji, Rana]
The RFM network failed today. We
had to reboot the frame builder anf restart
  
  3038   Wed Jun 2 18:36:20 2010 valeraDAQCDSNoise generators in LSPAlex wrote a new code to implement LSP
noise generator. The code is based on 64
bit random number generator from Numerical
 noisegenerators.pdf 
  3090   Sat Jun 19 17:31:48 2010 ranaDAQCDSExcess Noise in C1:IOO-MC_DRUM1 fixed by rebootI was getting an excess noise in the C1:IOO-MC_DRUM1
channel - it was a flat spectrum of 10 cts/rHz
  
  3117   Thu Jun 24 18:47:26 2010 FrankDAQIOOVME crate rebooted we had
to reboot
the IOO VME crate right before lunch
  
  1   Wed Oct 17 18:46:33 2007 ranaConfigurationGeneraleLog ChangeThis is the first entry in the [U]new[/U]
40m eLog.
  
  20   Fri Oct 26 21:48:40 2007 waldmanConfigurationOMCFiber to 056I set up a 700 mW NPRO in Rana's lab and launched
it onto a 50m fiber.  I got a few mW onto
the fiber,  enough to see with a card before
  
  21   Sat Oct 27 19:00:44 2007 waldmanConfigurationOMCHanging, locked OMC with REFL extracted.I got the OMC locked to the fiber output today.
 It was much more difficult than I expected
and I spent about 30 minutes or so flailing
  
  22   Sun Oct 28 03:03:42 2007 ranaConfigurationIOOThree Way Excitement[SIZE=2][B]We've been trying to measure the
MC mirror internal mode frequencies so that
we can measure
  
  26   Mon Oct 29 12:20:15 2007 waldmanConfigurationOMCChanged OMS filtersI changed the OMS configuration so that some
of the OMC-SUS LED channels go to a breakout
box so that we can input the PDH error signal.
  
  27   Mon Oct 29 23:10:05 2007 waldmanConfigurationOMCLost in DAQspace[Pinkesh, Sam]

In setting up a Digital based control of
 SS.pdfSS.gif 
  30   Tue Oct 30 13:58:07 2007 ajwConfigurationIOOMC RingdownsHere's a quick fit-by-eye to the latter part
of the data from tek00000.xls.
 CavityRingdown.pngCavityRingdown.m 
  40   Wed Oct 31 15:22:59 2007 robConfigurationIOOMode Cleaner transfer functionI measured the transfer function of the input
mode cleaner using a PDA255 and the ISS.
 First I put the PD in front of the ISS out-of-loop
 MCtf.pdf 
  45   Thu Nov 1 11:45:30 2007 tobinConfigurationIOOMode cleaner drag-wipingAndrey, Bob, David, John Miller, Rana, Rob,
Steve, Tobin
  
  67   Tue Nov 6 10:42:01 2007 robConfigurationIOOmode cleaner lockedIncreased the power exiting the PSL by turning
the half-wave plate after the MOPA, opened
the PSL shutter, and aligned the mode cleaner
  
  70   Tue Nov 6 15:37:34 2007 robConfigurationSUSrampdown script/cvs/cds/caltech/scripts/SUS/rampdown.pl is
now in the crontab for op340m, running every
half-hour at 15&45.  It checks the suspension
  
  71   Tue Nov 6 16:48:54 2007 tobinConfigurationComputersscopes on the netI configured our two 100 MHz Tektronix 3014B
scopes with IP addresses: 131.215.113.24
([url=http://scope0/]scope0[/url]) and 113.215.113.25
  
  72   Tue Nov 6 18:18:15 2007 tobinConfigurationComputersI broke (and fixed) conloggerIt turns out that not only restart_conlogger,
but also conlogger itself checks to see that
it is running on the right machine.  I had
  
  73   Tue Nov 6 23:45:38 2007 tobinConfigurationComputerstektronix scripts!I cooked up a little script to fetch the data
from the networked Tektronix scope.  Example
usage:
  
  74   Wed Nov 7 00:51:33 2007 andrey, rob, tobinConfigurationIOOMC ringdownsWe completed several ringdown measurements
this afternoon; Andrey is currently processing
the data.
  
  77   Wed Nov 7 10:55:21 2007 ajwConfigurationComputersbackup script restartedFollowing the reboot of computers on 10/31/07,
the backup script required restart (which
unfortunately "can't" be automated because
  
  78   Wed Nov 7 13:54:44 2007 robConfigurationIOOMode Cleaner transfer functionI performed the same procedure described [url=http://dziban.ligo.caltech.edu:40/40m/40]
here[/url], and re-measured the transfer
function of the mode cleaner to see the effect
 mctf.pdf 
  80   Wed Nov 7 14:05:59 2007 tobinConfigurationIOOMC ringdownModeling the mode cleaner as a simple cavity
with all losses lumped together, we expect
the cavity power to be
  
  84   Thu Nov 8 15:57:53 2007 tobinConfigurationPSLshelf removedI removed the sheet metal shelf from the PSL
enclosure, for easier access to the ISS.
  
  85   Thu Nov 8 18:44:01 2007 tobinConfigurationPSLISSTobin, Rob

With the Sense PD blocked, I adjusted the
  
  89   Fri Nov 9 17:33:33 2007 robConfigurationPSLISS
The 3.7 MHz is actually on the light.  It's
the beat between the 29.5 MHz sidebands and
  
  90   Fri Nov 9 21:36:14 2007 robConfigurationPSLFSSrob, rana

We looked at the FSS a bit today.  The most
  
  95   Mon Nov 12 15:05:49 2007 robConfigurationPSLFSS
Spent a bit of time fiddling with the FSS
again today.  In a not-particularly-systematic
  
  118   Tue Nov 20 13:06:57 2007 tobinConfigurationComputerslinux1 has new diskAlex put the new hard disk into linux1 along
with a fresh install of linux (CentOS). 
The old disk was too damaged to copy.
  
  124   Tue Nov 27 15:45:08 2007 robConfigurationPSLFSS loop
It's unclear (to me, at least) what was the
end result of the FSS path tweaking before
 FSSsmall.jpg 
  125   Tue Nov 27 15:47:17 2007 robConfigurationIOOMC loopAfter the FSS running pretty quick, I checked
the MC loop.  I used TPA 1&2.
 MCsmall.jpg 
  126   Tue Nov 27 16:18:58 2007 robConfigurationIOOMC loopReduced the common gain to 22dB in the [COLOR=blue]mcup[/COLOR]
script, so that the WFS would not blow the
lock.  The above measure of the OLG was done
  
  132   Wed Nov 28 16:46:28 2007 ranaConfigurationComputersscientific linux 5.0I tried installing Scientific Linux on Tiramisu.
The installation process was so bad (really)
that I quit after 15 minutes. Its back to
  
  133   Wed Nov 28 17:15:26 2007 ranaConfigurationSUSETMY damping / watchdogsSteve has noted that ETMY was often tripping
its watchdog. I saw this again today.
  
  137   Wed Nov 28 21:51:52 2007 tobinConfigurationPSLISSI replaced the front-end differential receivers
for the ISS's "inner-loop" sensor and monitor
diode inputs with lower-noise [url=http://focus.ti.com/docs/prod/folders/print/ths4131.html]THS4131[/url]'s
  
  138   Thu Nov 29 10:36:47 2007 albertoConfigurationComputer Scripts / ProgramsAgilent 82357B GPIB to USB Interface Installation ProcedeureTo run the Agilent Automation-Ready CD provided
with the interface is only the first step
of the installation. Apparently there should
  
  140   Thu Nov 29 14:29:22 2007 tobinConfigurationComputerslinux1 httpd/conlogger fixedI think I fixed the [url=http://linux1/cgi-bin/conlog_web.pl]conlogger
web interface on linux1[/url].
  
ELOG V3.1.3-