ID Date Authordown Type Category Subject Text Attachments
  4470   Wed Mar 30 21:21:15 2011 BryanConfigurationGreen LockingThe wonderful world of mode-matchingStep 4: Matching into  Oven_Lens_Solution_66mm.pngMatching_Into_Green_Oven_zoomed_out.pngMatching_Into_Green_Oven_zoomed_in.png 
  4476   Thu Mar 31 14:10:00 2011 BryanConfigurationGreen LockingThe wonderful world of mode-matching

    

       
            
 P3310028.JPGP3310029.JPG 
  4477   Thu Mar 31 15:23:14 2011 BryanConfigurationGreen LockingThe wonderful world of mode-matching

    

       
            
 Zoomed_out_fitting01.pngZoomed_in_fitting01.png 
  4481   Fri Apr 1 18:54:41 2011 BryanConfigurationGreen LockingY end doubling ovenThe doubling oven is now ready to go for
the Y arm. The PPKTP crystal is mounted in
the oven:
 P4010036.JPGP4010041.JPG 
  4485   Mon Apr 4 14:20:32 2011 BryanConfigurationGreen LockingThe wonderful world of mode-matching   Waist_Fits_from_laser.pngWaist_Fits_Bench_Position.png 
  4486   Mon Apr 4 18:58:44 2011 BryanConfigurationGreen LockingA beam of purest greenWe now have green light at the Y end. 
The set-up (with careful instructions
 P4040042.JPG 
  4495   Wed Apr 6 22:13:24 2011 BryanConfigurationGreen LockingResonating green light!Every so often things just work out. You
do the calculations, you put the lenses on
the bench, you manually adjust the pointing
  
  4520   Wed Apr 13 16:56:08 2011 BryanConfigurationGreen LockingY-ARM Green-Locked! Locked!
The Y-arm can
  
  4525   Thu Apr 14 17:45:59 2011 BryanConfigurationGreen LockingI leave you with these messages...OK…
the Y-arm may be locked with green light,
which was the goal, and this is all good
  
  4532   Fri Apr 15 13:43:23 2011 BryanConfigurationGreen LockingI leave you with these messages...Y-end PDH electronics.  Y_End_Electronics_TF.png 
  13792   Thu Apr 26 18:58:21 2018 BruceConfigurationALSNew look EX Fiber coupling - pol stability    
  8160   Mon Feb 25 20:25:33 2013 BrettUpdateSUSNew Global Damping MEDM ScreensGlobal damping screens are in progress
for the new global damping infrastructure
Jamie discussed in log #8159. The main overview
  
  8161   Mon Feb 25 20:49:07 2013 BrettUpdateSUSMinor Mod made to SUS_GLOBAL block I made a minor modification to install
some output filters in the new global damping
GLOBAL box in c1sus.mdl. These will be needed
  
  8172   Tue Feb 26 16:13:18 2013 BrettUpdateSUSITMY and ETMY mysterious loop gain difference of 2.5While doing initial measurements for the
new global damping infrastructure I discovered
that the ETMY loop between the OSEM actuation
 Screenshot.png 
  8174   Tue Feb 26 17:56:15 2013 BrettUpdateSUSGlobal Damping UpdateThe global damping input and output matrices
were installed to run for the Y-arm. Since
we are using just one arm for now, only the
  
  8193   Wed Feb 27 22:28:53 2013 BrettUpdateSUSGlobal Damping Update New excitation points were added
after the global damping loops for more testing
options. The updated c1sus.mdl model was
 DampNoise_to_YARM_fig_27Feb2013.png 
  8207   Fri Mar 1 16:37:45 2013 BrettUpdateSUSGlobal Damping UpdateBrett and Kamal
The global damping testing for the
week is now complete. The c1sus.mdl simulink
 GlobalDamp_Simulink.pngGlobalDampScreens.png 
  8220   Mon Mar 4 16:26:45 2013 BrettUpdateSUSGlobal Damping Noise MeasurementHere is an amplitude spectrum plot of y-arm
cavity noise with a 50 Hz cutoff damping
filter of the form zpk(0,[50;50],1). The
 YARM_Noise.png 
  4257   Mon Feb 7 19:21:32 2011 Beard PapaMetaphysicsPhotosThe Adventures of Dr Stochino and Beard Papa    
  7730   Tue Nov 20 02:57:24 2012 Ayaka, Den, KojiUpdateLockingred in armsWe aligned and locked x and y arms.
MCL loop makes arms lock unstable,
adds a lot of noise at frequencies 60-100
 8x 
  7718   Fri Nov 16 03:12:39 2012 Ayaka, DenUpdateGreen Lockingxarm lockedWe aligned and locked xarm for green.
 etmxf.png 
  7589   Mon Oct 22 20:44:49 2012 AyakaUpdateAdaptive Filteringmicrophone noiseI will do some experiments on acoustic
noise canceling during my stay.
Now I am planning to cancel acoustic
 mic_noise2.png 
  7596   Tue Oct 23 10:24:42 2012 AyakaUpdateAdaptive Filteringmicrophone noise

    

       
            
  
  7607   Wed Oct 24 14:15:34 2012 AyakaUpdateAdaptive Filteringmicrophone noisePrevious results
I am measuring the noise level of
the microphones. The circuit does not seems
 mic_open.pngmic_noise.png 
  7621   Thu Oct 25 09:53:23 2012 AyakaUpdateAdaptive Filteringmicrophone noise

    

       
            
  
  7633   Fri Oct 26 18:25:02 2012 AyakaUpdateAdaptive FilteringMicrophone noise again[Raji, Ayaka]
Thanks to Den, power supplies for
microphone circuit are changed.
 mic_noise.png 
  7636   Mon Oct 29 08:41:22 2012 AyakaUpdateAdaptive FilteringMicrophone noise again

    

       
            
  
  7672   Mon Nov 5 20:37:01 2012 AyakaUpdateWienerFilteringPlay with wiener filtering I am trying to find what limits the
reduction rate with wiener filtering.
I did some calculations below:
 estimate.pngWfilter_notch.png 
  7688   Thu Nov 8 10:11:58 2012 AyakaUpdateWienerFilteringPlay with wiener filteringI will attach a document which describes
how the noise affect the wiener filter and
the noise cancellation ratio.
 document.pdfestimate.pngR_model.png 
  7702   Tue Nov 13 00:28:10 2012 AyakaUpdateIOOMC locked, spots centered[Rana, Ayaka, Jenne]
We aligned the REFL beam to the center
of PD.
 spot1112.pngDSC_4902.JPGDSC_4904.JPG 
  7707   Tue Nov 13 21:05:22 2012 AyakaUpdateWienerFilteringAcoustic noise cancellation with MC In order to perform acoustic noise
cancellation with MCL signal, I am trying
to find sweet spots for microphones.
 9x 
  7733   Tue Nov 20 15:24:52 2012 AyakaUpdatePEMSeismometers and a microphone I got two seismometers and one microphone
back from Tara.
They are now near the Gurlap under
  
  7738   Wed Nov 21 21:06:13 2012 AyakaUpdateLSCcalibration of armsMotivation
In order to estimate whether we can
see acoustic coupling in arms or not, we
 7x 
  7743   Mon Nov 26 10:42:06 2012 AyakaUpdateLSCcalibration of armsI uploaded a zip file that contains data
files used for the calibration.
OLTF_x/y.txt: the open loop transfer
 armcalib.zip 
  7748   Mon Nov 26 23:45:52 2012 AyakaUpdateIOOTuning MC_L[Rana, Jamie, Ayaka]
We could not lock the arms with MC_L
loop on. Therefore we measured the change
 POYerr_MCL.jpgMCL-MCFxover.jpgMCL-MCFxover2.jpg121126.tar.gz 
  7751   Tue Nov 27 01:03:42 2012 AyakaUpdateWienerFilteringSound on PSL Last Thursday, I put the speaker
and my laptop in the PSL table, and make
triangular wave sound with the basic frequency
 gauss_psdcoh_mcf.pngtri40_psdcoh_mcf.pnggauss_filters_mcf.pngGauss_estimatefilters_mcf.png 
  7760   Wed Nov 28 23:55:13 2012 AyakaUpdateWienerFilteringSound on PSL I have been searching for the way
we can subtract signal better since I could
see the acoustic coupling signal remains
 tri40_psdcoh_mcf_varioust.pnggauss_psdcoh_mcf_varioust.png 
  7762   Thu Nov 29 02:43:48 2012 AyakaUpdatePEMDecreased RMS in Seismometers

    

       
            
 GUR1Xfilterbank.pngseismometers1129.jpgseismometers1129.pdf 
  7778   Mon Dec 3 17:04:12 2012 AyakaUpdatePSLPMC calibration for MC_F calibrationIn order to calibrate MC_F signal, I need
to know the calibration value from thorlab's
PZT driver to laser frequency.
 DSC_4955.JPGsweep_PZTdriver.pngPMC_PZT_FSR.pdftrans_fit.pngPMC-PZTcal_121203.zip 
  7784   Tue Dec 4 18:53:50 2012 AyakaUpdateAlignmentBS chamberBS chamber seemed to be kicked again around
10:00 am today.
I moved PZT mainly in YAW and locked
 BSchamb1204.pdf 
  7789   Wed Dec 5 01:06:22 2012 AyakaUpdateWienerFilteringThe microphones and the speaker on the AP table In order to see the acoustic coupling
on arm signals, I set 6 microphones and the
speaker on the AP table. The microphones
 DSC_4956.JPGDSC_4961.JPGAPsig.pdf 
  7799   Fri Dec 7 20:34:31 2012 AyakaUpdateSUSoplevs as acoustic and seismic noise couplers at high frequenciesI will
just leave the picture of spectrum that shows
the injected acoustic sound effects due to
 YARM_acous_oplev.pdf 
  7808   Tue Dec 11 09:31:47 2012 AyakaUpdateLSCOplev update for improving sensitivity Motivation
We observed that oplev servos affect
 7x 
  7809   Tue Dec 11 10:09:04 2012 AyakaHowToPEMcables needs care

    

       
            
  
  7812   Tue Dec 11 21:53:37 2012 AyakaUpdateLSCOplev update for improving sensitivity[Rana, Ayaka]
The BS oplev pitch feedback came
back.
 OL_BSpit.pdfBSoplevservo.png 
  7814   Wed Dec 12 11:49:05 2012 AyakaUpdateLSCAcoustic noise in POX and AS error signal[Koji, Ayaka]
Last night, I injected acoustic noise
at POX table and AS table with oplev controls
 POX_noise4.pdfAScontXARM_acoustic.pdf 
  7823   Thu Dec 13 17:24:53 2012 AyakaUpdatePSLPMC calibration for MC_F calibration I calibrated MC_F signal into Hz/rtHz
unit using the transfer function from
MC_F to PMC feedback signal.
 6x 
  7824   Thu Dec 13 18:06:59 2012 AyakaUpdateWienerFilteringNew microphone mounts Yesterday, I made new mounts for
microphones.
 IMG_0129.JPGIMG_0130.JPG 
  7829   Fri Dec 14 03:32:51 2012 AyakaUpdateLSCHigh frequency noise in AS signalI calibrated the AS error signal into the
displacement of the YARM cavity in the same
way as I did before (elog).
 XARM_OL.pdfAS_ITMXexc.pdfASspe_noise.pdfASgain.pngASspe.tar.gz 
  7830   Fri Dec 14 03:49:02 2012 AyakaUpdateGeneralEarthquakeThere was an earthquake around 2:30 am.
Now all the mirrors except SRM are damped.
 earthquake.pngseis.pdf 
ELOG V3.1.3-