  91   Sun Nov 11 21:05:55 2007 ranaHowToSUSMC Touching or notI wrote a script: [I]SUS/freeswing-mc.csh[/I],
which gives the MC mirrors the appropriate
kicks
  
  92   Sun Nov 11 21:21:04 2007 ranaHowToComputersNew DVTo use the new ligoDV (previously GEO DV)
to look at 40m data, open up a matlab, set
up for mDV as usual,
 Screenshot-1.png 
  107   Thu Nov 15 18:23:55 2007 JohnHowToComputersSwap CAPS and CTRL on a Windows 2000/XP machineI've swapped ctrl and caps on the four control
room Windows machines. Right ctrl is unchanged.
  
  120   Tue Nov 20 18:35:20 2007 JohnHowToComputersMatLab in EmacsIf you can't get MatLab to run in emacs try
adding the following to the .emacs file
  
  142   Thu Nov 29 18:10:13 2007 AlbertoHowToComputer Scripts / ProgramsGPIB ScriptsI've spent a lot of time trying to configurate
the GPIB-USB interface for the HP4195. After
installing 1) the Agilent libraries, 2) the
  
  143   Thu Nov 29 19:35:14 2007 ranaHowToComputer Scripts / ProgramsGPIB Scripts[quote]I've spent a lot of time trying to
configurate the GPIB-USB interface for the
HP4195. After installing 1) the Agilent libraries,
  
  158   Mon Dec 3 16:24:47 2007 tobinHowToComputersGNU screen[url=http://jmcpherson.org/screen.html]GNU
screen[/url] is a utility that can be quite
handy for managing long-running psuedo-interactive
  
  159   Mon Dec 3 17:55:39 2007 tobinHowToComputer Scripts / ProgramslinemonMatlab's Signal Processing toolbox has a [url=http://www.mathworks.com/access/helpdesk/help/toolbox/signal/index.html?/access/helpdesk/help/toolbox/signal/spectrum.html]set
of algorithms for identifying sinusoids in
data[/url].  Some of them (e.g., [url=http://www.mathworks.com/access/helpdesk/help/toolbox/signal/index.html?/access/helpdesk/help/toolbox/signal/rootmusic.html&http://www.mathworks.com/cgi-bin/texis/webinator/search/]rootmusic[/url])
  
  164   Wed Dec 5 10:57:08 2007 albertoHowToComputersConnecting the GPIBto USB interface to the Dell laptopThe interface works only on one of the USB
ports of the laptop (the one on the right,
looking at the computer from the back).
  
  166   Wed Dec 5 16:57:36 2007 tobinHowToComputer Scripts / ProgramsSR785 data converter on linuxI was pleased to find that the SR785 Data
Viewer (including the command line conversion
utility) installs and works in linux using
  
  175   Thu Dec 6 18:11:15 2007 robHowToComputer Scripts / ProgramsMaking DMF monitors
I was able to use the matlab compiler to
compile a version of the [B]linetracker[/B]
  
  184   Mon Dec 10 13:54:26 2007 robHowToComputer Scripts / ProgramsDon't blame the Matlab compiler
For human error.  We should be careful to
only run the compiler outside the mDV directory
  
  206   Thu Dec 20 19:05:34 2007 waldmanHowToOMCHOWTO build front endsFor instance,  to build the TPT front end
code.
  
  274   Sat Jan 26 18:12:45 2008 ranaHowToComputersextra processes and crashesThere were a load of extra processes on op440m;
they were all related to rogue DV processes
(frameMemRead, framer4, xmgrace, etc.)
  
  280   Mon Jan 28 15:11:38 2008 robHowToDMFrunning compiled matlab DMF tools
I compiled Rana's seisBLRMS monitor, and
it's now running on mafalda.  To start your
  
  349   Sun Mar 2 23:43:45 2008 ranaHowToLSCPD6 responseJohn's PD plotting script is superior to all
of the ones we had before; lets make him
post the script so we can all use it.
  
  395   Sun Mar 23 00:43:08 2008 mevansHowToGeneralOnline Adaptive FilteringI wrote a short document about the OAF running
on the ASS.  Since there is no BURT setup,
I put a script in /cvs/cds/caltech/scripts
 OnlineAdaptiveFilter.pdf 
  404   Wed Mar 26 13:41:53 2008 AndreyHowToSUSModification of ''C1DRIFT_MONITOR''I learned how to modify the drift-monitor
 in MEDM so that values on it change colors
from green to yellow to red depending how
  
  478   Thu May 15 10:40:21 2008 steveHowToGeneralLisa Goggin, PhDLisa Goggin successfully defended her thesis
on May, 13 2008
 lisa.JPG 
  536   Tue Jun 17 22:00:53 2008 JohnHowToPSLProblems turning MZ servo on/offWe were unable to toggle the MZ servo on/off
(Blank/Normal) from MEDM. Pushing on the
Xycom board and cables changed the fault
  
  551   Sun Jun 22 21:38:49 2008 robHowToGeneralIFO CONFIGURE
Now that we're getting back into locking,
it's nice to have a stable alignment of the
  
  615   Tue Jul 1 14:24:58 2008 robHowToComputer Scripts / Programsconlog time machine
I've written a perl script (now in the $SCRIPTS/general
directory) which implements a "conlog restore"
  
  617   Tue Jul 1 21:27:27 2008 robHowToComputer Scripts / Programsslider twiddling after reboot
Sometimes after we reboot the front-end machines,
some of the hardware gets stuck in an unknown
  
  636   Sun Jul 6 16:17:40 2008 tobinHowToComputersSVNI was able to check out the 40m SVN here in
Livingston using this command:
  
  639   Mon Jul 7 13:49:27 2008 YoichiHowToPSLMZ offset, gain tipsJohn, Yoichi

This morning John found that MZ servo is
  
  654   Thu Jul 10 13:47:12 2008 YoichiHowToComputerssvn access via httpsNow you can access to the svn repository on
nodus by https.
To perform a checkout, you can use the following
  
  788   Mon Aug 4 00:56:07 2008 KojiHowToGeneralAbs. Len. Meas. ~ Auto freq scanner with GPIB[B]Work log on August 3rd  - Part1[/B]

o Yesterday I was too much tired of changing
 freq_scan.png 
  833   Thu Aug 14 10:26:45 2008 steveHowToSUSsus cable pin cheater for out of vac dampingThe 40m D25 vacuum feed troughs give you a
mirror image pin count.
 suscabmin.png 
  867   Thu Aug 21 17:55:14 2008 ranaHowToIOOMC WFS DC OffsetsI ran the McWFS_dc_offsets script to trim
out the DC offsets on the MC WFS DC signals.
  
  875   Mon Aug 25 10:23:53 2008 steveHowToGeneralcable killerRack 1Y7 double violation:

BNC cables left to be jammed by door
 cablkill.pngcablkll2.png 
  882   Mon Aug 25 17:45:34 2008 rana, josephb, robHowToPEMAccelerometer rangeJoe shows us by jumping up ~15" in the control
rom that the accelerometers are set with
not enough gain.
 Screenshot-4.png 
  889   Tue Aug 26 19:07:37 2008 YoichiHowToComputersReading data from Agilent 4395A analyzer through GPIB from *Linux* machineI succeeded in reading data from Agilent 4395A
analyzer, who's floppy is crappy, through
GPIB from a Linux machine using
  
  890   Wed Aug 27 10:55:35 2008 YoichiHowToComputersAnnoying behavior of the touch pads of the lab. laptops is fixedI was sick of the stupid touch pad behavior
of the lab. laptops, i.e. firefox goes back
and forth in the history when the cursor
  
  904   Fri Aug 29 18:24:48 2008 ranaHowToPSLPMC: PZT CalibrationI calibrated the PMC PZT at DC by using 'trianglewave'
to drive the DC offset slider
and reading back PMC_PZT and PMC_TRANSPD_F
 pmc-pzt-cal.pdfmcf.png 
  966   Thu Sep 18 18:38:14 2008 YoichiHowToComputersHow to compile an SNL code for VxWorks Dave Barker guided me through how to compile
an SNL code into a Motorola 162 CPU object.
  
  977   Mon Sep 22 16:51:27 2008 YoichiHowToComputersNetwork GPIBI was able to make the wireless connected
GPIB interface work with SR785.
Now you can download data from SR785 through
  
  983   Tue Sep 23 00:47:24 2008 YoichiHowToComputersNetwork GPIB[quote]
I wrote a new script called "netgpibdata.py"
which works similarly as "getgpibdata.py".
  
  1125   Mon Nov 10 11:06:09 2008 robHowToIOOmode cleaner locked
I found the mode cleaner unlocked, with (at
least) MC1 badly mis-aligned.  After checking
  
  1132   Thu Nov 13 11:33:25 2008 AlbertoHowToTreasureMaking (good) Matlab figuresJust a little summary of some useful ways
to change plot settings in Matlab that I
wanted to share and remember for the future:
  
  1139   Mon Nov 17 11:01:15 2008 AlbertoHowToElectronicsCalibrating the Frequency Standard of the MarconiI locked the [COLOR=purple][I]SRS Rubidium
Frequency Standard FS275[/I][/COLOR] to the
the 1pps from the GPS. The specs from the
 2023ASeriesOperatingManual.pdfSRS_FS275_Rubidium_Frequency_Standard.pdf 
  1150   Fri Nov 21 16:03:50 2008 ranaHowToGeneralRecharging BatteriesI found some black & red "Ninja" alkaline
AA batteries in the battery charger. [COLOR=red]This
is dangerous.[/COLOR] Please
  
  1181   Fri Dec 5 20:40:38 2008 YoichiHowToComputersElog multi-keyword searchThe current Elog search allows you to look
for only one keyword in the text.
You cannot search for two keywords by simply
  
  1226   Wed Jan 14 09:22:43 2009 steveHowToVACN2 supply pressure lowered for vac valves[quote]I've been replacing the N2 bottles
recently.
I noticed that the consumption is too high.
 n280d.jpg 
  1238   Mon Jan 19 15:10:37 2009 YoichiHowToComputersloadLIGOData a GUI for mDVI installed loadLIGOData, a product of my
weekend project, in  /cvs/cds/caltech/apps/loadLIGOData.
This is a Matlab GUI for getting data from
 loadLIGOData.pngplotLigoData.png 
  1247   Thu Jan 22 23:36:50 2009 peteHowTooplevsarm cavity oplev calibrationcalibrated the y-arm oplevs.  the procedure
is contained in a matlab script.  the whereabouts
of this script will be revealed in a future
 ETMYpitpower.pngETMYpitcal.png 
  1342   Thu Feb 26 20:09:32 2009 YoichiHowToComputersSR785 python scripts now produce plotsI updated the python scripts to remotely perform
measurements with an SR785.
Now these scripts can plot the results immediately
  
  1464   Thu Apr 9 20:56:12 2009 YoichiHowToGeneralRestore the alignment. Write elog entries.I often find that the mirrors are left mis-aligned
(like in X-arm mode) when I come in for the
locking, including tonight.
  
  1496   Sun Apr 19 11:34:33 2009 josephbHowToCamerasUSB Frame Grabber - How toTo use the Sensoray 2250 USB frame grabber:
Ensure you have the following packages
installed: build-essential, libusb-dev
  
  1517   Fri Apr 24 16:02:31 2009 steveHowToVACcryo pump interlock ruleI tested the cryopump interlock today.
It is touchy. I do not have full confidence
in it.
 cryo.png 
  1529   Tue Apr 28 16:36:24 2009 robHowToLockingsetting the RF CARM demod phaseTo set the demod phase for RF CARM, sensed
at REFL2 (REFL 166I), it suffices to set
the demod phase for REFL2 to be the optimal
 CARM_phases_REFL.pdfSRCL_phases_REFL.pdf 