  9287   Thu Oct 24 23:30:57 2013 jamieUpdateCDSnew dataviewer installed; no longer works on Ubuntu 10 workstations

    

       
            
  
  4261   Tue Feb 8 15:22:13 2011 kiwamuUpdateGreen Lockingnew electronics rack at X end Yesterday
I moved the whole green electronics stuff,
which had been sitting on the floor at the
 DSC_2861_ss.png 
  1109   Mon Nov 3 19:18:47 2008 AlbertoConfigurationGeneralnew elogPhil Ehrens kindly poured our elog's content
in a CD that now is here at the 40m.
I've been trying to install the 2.7.5 version
  
  1110   Mon Nov 3 21:38:32 2008 YoichiConfigurationGeneralnew elog[quote]I tried to recompile the elog from
the source code but the way gcc is called
must be wrong because I get this error message:
  
  6666   Wed May 23 11:30:39 2012 steveUpdatePEMnew emergency back up lights installedNew self checking emergency back
up lights were installed at 13 locations
in the 40m lab.
 IMG_1217.JPG 
  13323   Wed Sep 20 15:49:26 2017 ranaOmnistructureComputersnew internetLarry Wallace hooked up a new switch (Brocade
FWS 648G) today which is our 40m lab
interface to the outside world internet.
  
  14464   Mon Feb 18 19:16:55 2019 ranaSummaryComputersnew laptop setup: ASIAThe old IBM laptop (Asia) has died from
a fan error after 7 years. WE have a new
Lenovo 330 IdeaPad to replace it:
  
  14624   Mon May 20 13:16:57 2019 gautamSummaryComputersnew laptop setup: ASIA - ndscope and diagguiFollowing instructions here,
I installed ndscope on this machine. DTT
still could not be be run from this machine,
  
  14543   Mon Apr 15 18:29:07 2019 ranaSummaryComputersnew laptop setup: ASIA - yum issueshad trouble using YUM to update. This turned
out to be a config problem with our Martian
router, not the new laptop. Since I've
  
  14598   Wed May 8 22:11:46 2019 ranaSummaryComputersnew laptop setup: ASIA - yum issues
setup controls user using K Thorne
LLO CDS offsite workstation instructions
modified
/etc/fstab ala pianosa to NFS mount disks
set
  
  4412   Fri Mar 18 14:18:00 2011 kiwamuSummaryGeneralnew laser pointersJust for a record. We got 4 new laser
pointers (2 greens, 1 blue, and 1 green and
 DSC_2883_ss.jpg 
  4488   Tue Apr 5 17:31:59 2011 steveSummaryGeneralnew laser pointers

    

       
            
 P1070530.JPG 
  8717   Tue Jun 18 10:37:00 2013 SteveSummaryGeneralnew laser pointers  Red-green
laser pointers added to the depleted
stock of 2011
  
  13663   Fri Mar 2 01:45:06 2018 gautamUpdateALSnew look ALS electronicsI spent today making another daughter board
(so that we can use the new scheme for I
and Q for one arm), testing it (i.e. measuring
 IMG_6916.JPG 
  13666   Mon Mar 5 17:27:34 2018 gautamUpdateALSnew look ALS electronics - characterizationI did a quick test of the noise of the
new ALS electronics with the X arm ALS. Attachment
#1 shows the results - but something looks
 BeatMouthX_20180305_diffOut.pdf 
  13668   Thu Mar 8 00:40:25 2018 gautamUpdateALSnew look ALS electronics - characterizationI am almost ready for a digital test of
the new ALS electronics. Today, Koji and
I spent some time tapping new +/-24VDC DIN
 BeatMouthX_20180305_diffOut.pdf 
  1677   Tue Jun 16 09:02:30 2009 steveConfigurationVACnew maglev RGA scanThe maglev fore line pressure is 3e-6 torr
at CC2 after 4 days of pumping. Varian turbo
V-70 is pumping on it through V4 and VM2
 nmagd4scan.jpgnmagd4.jpg 
  1690   Tue Jun 23 10:06:03 2009 steveUpdateVACnew maglev RGA scan at day6The Maglev is running for 10 days with
V1 closed.  The pressure at the RGA-region
is  at 2e-9 torr on CC4 cold cathode
 newmagscand6.jpgnmagpresd10.jpg 
  1671   Fri Jun 12 09:56:38 2009 steveConfigurationVACnew maglev installedJoe and Steve
 
The retrofitted Osaka 390 was installed
 m390pd.jpg 
  4339   Tue Feb 22 23:11:42 2011 valeraUpdate new medm screens: C1ASS.adl and C1MCASS.adl   C1MCASS.jpegC1ASS.jpeg 
  1421   Tue Mar 24 13:10:07 2009 AlbertoConfigurationPSLnew mirror installed on the AP tableNew flipping mirror installed on the AP
table on the beam path to the REFL199 PD.
If you're missing the double demod
  
  2016   Tue Sep 29 01:50:10 2009 robConfigurationLSCnew modulation frequenciesMode cleaner length measured tonight.
 
33196198
  
  509   Sun Jun 1 19:25:10 2008 ranaConfigurationComputersnew monitor on op440mI installed the new 24" flat screen on op440m.
I increased the screen resolution from 1280x1024
to 1900x1200 using
 Andrey-440.jpgBusby08.jpg 
  9741   Thu Mar 20 11:16:16 2014 SteveUpdateGeneralnew projector 
[ Manasa, Ericq and Steve ]
 Vivitek
  
  8010   Wed Feb 6 15:10:22 2013 SteveUpdatePEMnew safety signs on exterier doors

    

       
            
 IMG_0068.JPG 
  148   Fri Nov 30 19:29:14 2007 ranaConfigurationSUSnew screenAndrey is working on a new screen to show
us the drift of the optics by alarming on
their osem values. [COLOR=darkred]You can
  
  376   Thu Mar 13 13:15:09 2008 aivanovUpdateComputer Scripts / Programsnew sfotware intall, backup filesNew:
op440m:40m>ls -alt /cvs/cds/caltech/target/c1susvme[12]/*.o
-rw-r--r--    1 controls staff       57920
  
  994   Thu Sep 25 17:14:31 2008 ranaConfigurationGeneralnew sitemap   vegemite.png 
  4551   Thu Apr 21 14:39:43 2011 steveUpdateRF Systemnew strain relieved N connectors at APNew right angle PVC, 2 x 2 x  1/4"
installed at the AP table to strain relief
the 1/4" spiral corrugated RF coaxes.
 P1070562.JPGP1070564.JPG 
  12650   Wed Nov 30 14:53:56 2016 SteveUpdateSUSnew sus wire stored in N2 filled dessicatorThe new SOS sus wire finally is stored
in a nitrogen filled dessicator. This was
recommended by Ca. Fine Wire to minimize
 dessicatorC.jpgwireN2c.jpg 
  10628   Tue Oct 21 17:44:28 2014 jamieOmnistructureComputer Scripts / Programsnew version of cdsutils (351) installedI just installed cdsutils r351 at /ligo/apps/linux-x86_64/cdsutils. 
It should be available on all workstations.
It includes a bunch of bug fixes
  
  10655   Thu Oct 30 16:25:22 2014 ericqOmnistructureComputer Scripts / Programsnew version of cdsutils (361) installed

    

       
            
  
  2763   Sun Apr 4 17:32:07 2010 AlbertoMetaphysicsGeneralnew y-arm?


   
        
            
  
  15304   Wed Apr 15 15:15:17 2020 ChubUpdateVACnitrogen cylinders deliveredFour nitrogen cylinders replaced the empties
in the rack at the west entrance.  Additionally,
Airgas will now deliver only once a week.
  
  9221   Tue Oct 8 11:29:30 2013 SteveUpdatePEMno Janitor day todayThis was the second week without wet mopping
the floor and wet wipe down of the vacuum
envelope.
 dirtyVacpump.jpg 
  4784   Fri Jun 3 18:12:03 2011 steveUpdateComputersno PEM channelsAA filter box was removed and modified
at 1Y7 today. The -5V power supply was current
limited when I plugged it back in. It was
  
  3941   Wed Nov 17 20:44:59 2010 yutaSummaryCDSno QPD channels on c1sus machine today(Joe, Suresh, Yuta)

  
  5741   Wed Oct 26 10:07:16 2011 steveUpdateGeneralno electricity ....... will be recheduled

    

       
            
  
  5728   Mon Oct 24 14:26:01 2011 steveUpdateGeneralno electricity on Nov. 19
    
       

            
  
  5827   Mon Nov 7 08:25:15 2011 steveUpdateGeneralno electricity on Nov. 20The
Nov.19 interruption was rescheduled to be
on Nov.20,2011
  
  4867   Thu Jun 23 21:34:21 2011 kiwamuUpdateCDSno foton on the CentOS machines For
some reasons foton's deafault sample rate
is NOT correct when it runs on the CentOS
  
  3750   Thu Oct 21 05:51:10 2010 kiwamuUpdateLockingno green beat note Still I didn't see any beat note signals..
 With a help from Suresh, Yuta
  
  3754   Thu Oct 21 15:59:28 2010 kiwamuUpdateLockingno green beat note : detailsLast night I tried searching for a beat
note signal with two different PD trans impedance
 bw.png 
  5526   Thu Sep 22 23:02:15 2011 SureshUpdateIOOno light on WFS2. Realigned input onto both WFSRana noticed that the sum on WFS2 was about
10 times smaller than that on WFS1. Though
the beam appeared centered on the DC QPD
  
  437   Tue Apr 22 17:08:04 2008 CarynUpdateIOOno signal for C1:IOO-MC_L C1:IOO-MC_L signal was at zero for the past
few days
  
  4287   Mon Feb 14 12:37:23 2011 kiwamuUpdateASCno signal from IP_ANG_Seg1It turns out there are no reasonable
signal from the segment 1 on the IP_ANG QPD.
  
  4296   Tue Feb 15 06:15:07 2011 SureshUpdateASCno signal from IP_ANG_Seg1[Valery, kiwamu, Jenne, Suresh]
    I first interchanged
the two QPD's on the Y end table to see if
 Y-end_beam.JPG 
  4215   Thu Jan 27 21:43:37 2011 KojiUpdateGreen Lockingno transmission of ALS signalsNo signal is transmitted from C1:GCV-SCX_ETMX_ALS
(on c1gcv) to C1:GCV-SCX_ETMX_ALS (on c1scx)
I can't find RFM definition for ALS
  
  4219   Fri Jan 28 11:08:44 2011 josephbUpdateGreen Lockingno transmission of ALS signalsAs you've
correctly noted, the source of the C1:GCV-SCX_ETMX_ALS
channels is in the c1gcv model.  The first
  
  11786   Wed Nov 18 23:18:07 2015 ericqUpdateComputer Scripts / Programsnodus /boot cleared upThe /boot partition was filling up with
old kernels. Nodus has automatic security
updates turned on, so new kernels roll in
  
ELOG V3.1.3-